• Title/Summary/Keyword: Large structures

Search Result 4,671, Processing Time 0.026 seconds

A Study on the Shape Analysis of Cable-Dome Structures (케이블-돔 복합구조의 형상해석에 관한 연구)

  • 권택진;한상을;최옥훈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.93-100
    • /
    • 1998
  • The basic systems of spatial structures such as shells, membrane, cable-nets and tensegrity structure have been developed to create the large spaces without column. These structures may have large freedom in scale and form, and especially tensegrity structures are received much attention from the view points of their light weight and aesthetics. But There re some difficulties concerning structural stability, surface formation and construction method. One of the way to solve these problems reasonably is a combination of tensile members and rigid members. A structural system based on this concept is referred to as the "HTS ( Hybrid Tension Structure )". This is a type of flexible structural system which is unstable initially, because the cable material has little initial rigidity. As cable - dome hybrid structures is a type of HTS, the initial stress for the self- equilibrated system having stable state have to be introduced. To determine initial stress having stable state, the shape finding analysis is required before the stress - deformation analysis. In this paper, the primary objective is to derive the nonlinear finite element formula of cable and truss members considering geometric nonlinearity for shape finding of cable-dome, and to propose the method to decide the initial stress by the shape analysis of cable-dome hybrid structure with the self-equilibrated state.

  • PDF

Optimal placement and tuning of multiple tuned mass dampers for suppressing multi-mode structural response

  • Warnitchai, Pennung;Hoang, Nam
    • Smart Structures and Systems
    • /
    • v.2 no.1
    • /
    • pp.1-24
    • /
    • 2006
  • The optimal design of multiple tuned mass dampers (multiple TMD's) to suppress multi-mode structural response of beams and floor structures was investigated. A new method using a numerical optimizer, which can effectively handle a large number of design variables, was employed to search for both optimal placement and tuning of TMD's for these structures under wide-band loading. The first design problem considered was vibration control of a simple beam using 10 TMD's. The results confirmed that for structures with widelyspaced natural frequencies, multiple TMD's can be adequately designed by treating each structural vibration mode as an equivalent SDOF system. Next, the control of a beam structure with two closely-spaced natural frequencies was investigated. The results showed that the most effective multiple TMD's have their natural frequencies distributed over a range covering the two controlled structural frequencies and have low damping ratios. Moreover, a single TMD can also be made effective in controlling two modes with closely spaced frequencies by a newly identified control mechanism, but the effectiveness can be greatly impaired when the loading position changes. Finally, a realistic problem of a large floor structure with 5 closely spaced frequencies was presented. The acceleration responses at 5 positions on the floor excited by 3 wide-band forces were simultaneously suppressed using 10 TMD's. The obtained multiple TMD's were shown to be very effective and robust.

Wind loads and wind-resistant behaviour of large cylindrical tanks in square-arrangement group. Part 1: Wind tunnel test

  • Liu, Qing;Zhao, Yang;Cai, Shuqi;Dong, Shilin
    • Wind and Structures
    • /
    • v.31 no.6
    • /
    • pp.483-493
    • /
    • 2020
  • Large cylindrical floating-roof tanks, constructed as oil containers, are usually distributed regularly in open area and easily exposed to severe wind loads. However, wind pressures around these grouped squat tanks appear to have not been clearly given in design codes or thoroughly studied in existing researches. This paper conducts a detailed investigation on wind loads on the external wall of a four-tank group in square arrangement. To achieve that, wind tunnel tests are carried out on both empty and full tank groups, considering various wind angles and spacing. Results show that 3 regions in elevation can be identified on the tank shell according to the circumferential wind pressure distribution. The upper 2 regions cover a relatively small portion of the shell where excessive negative pressures are spotted, setting an alarm to the design of the top angle and stiffening rings. By comparing results on grouped tanks to those on an isolated tank, grouping effects concerning wind angle, tank position in group and spacing are discussed. Deviations on pressure distributions that will compromise structural safety are outlined, including the increase of negative pressures, the shift of maximum pressure locations as well as the change of positive pressure range. And, several potentially unfavourable wind pressure distributions are selected for further analyses.

Compound damping cable system for vibration control of high-rise structures

  • Yu, Jianda;Feng, Zhouquan;Zhang, Xiangqi;Sun, Hongxin;Peng, Jian
    • Smart Structures and Systems
    • /
    • v.29 no.4
    • /
    • pp.641-652
    • /
    • 2022
  • High-rise structures prone to large vibrations under the action of strong winds, resulting in fatigue damage of the structural components and the foundation. A novel compound damping cable system (CDCS) is proposed to suppress the excessive vibrations. CDCS uses tailored double cable system with increased tensile stiffness as the connecting device, and makes use of the relative motion between the high-rise structure and the ground to drive the damper to move back-and-forth, dissipating the vibration mechanical energy of the high-rise structure so as to decaying the excessive vibration. Firstly, a third-order differential equation for the free vibration of high-rise structure with CDCS is established, and its closed form solution is obtained by the root formulas of cubic equation (Shengjin's formulas). Secondly, the analytical solution is validated by a laboratory model experiment. Thirdly, parametric analysis is conducted to investigate how the parameters affect the vibration control performance. Finally, the dynamic responses of the high-rise structure with CDCS under harmonic and stochastic excitations are calculated and its vibration mitigation performance is further evaluated. The results show that the CDCS can provide a large equivalent additional damping ratio for the vibrating structures, thus suppressing the excessive vibration effectively. It is anticipated that the CDCS can be used as a good alternative energy dissipation system for vibration control of high-rise structures.

Acoustic emission localization in concrete using a wireless air-coupled monitoring system

  • Yunshan Bai;Yuanxue Liu;Guangjian Gao;Shuang Su
    • Smart Structures and Systems
    • /
    • v.32 no.4
    • /
    • pp.195-205
    • /
    • 2023
  • The contact acoustic emission (AE) monitoring system is time-consuming and costly for monitoring concrete structures in large scope, in addition, the great difference in acoustic impedance between air and concrete makes the detection process inconvenient. In this work, we broaden the conventional AE source localization method for concrete to the non-contact (air-coupled) micro-electromechanical system (MEMS) microphones array, which collects the energy-rich leaky Rayleigh waves, instead of the relatively weak P-wave. Finite element method was used for the numerical simulations, it is shown that the propagation velocity of leaky Rayleigh waves traveling along the air-concrete interface agrees with the corresponding theoretical properties of Lamb wave modes in an infinite concrete slab. This structures the basis for implementing a non-contact AE source location approach. Based on the experience gained from numerical studies, experimental studies on the proposed air-coupled AE source location in concrete slabs are carried out. Finally, it is shown that the locating map of AE source can be determined using the proposed system, and the accuracy is sufficient for most field monitoring applications on large plate-like concrete structures, such as tunnel lining and bridge deck.

Investigation and Numerical Analysis of Node Connectors in Free-Form Spatial Structures

  • Hwang, Kyung-Ju;Park, Don-U;Park, Sun-Woo;Knippers, Jan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.3 s.25
    • /
    • pp.87-95
    • /
    • 2007
  • The recent completions of free-form spatial structures provide us a very attractive form. To realize such an extraordinary shape, it is absolutely necessary that the connector systems have to be investigated the characteristics of the systems and analyzed with a practicable method. In this context, this research consists of not only literature research but also numerical analysis with selected connector systems, which was adopted in real free-form spatial structures. For numerical analysis, especially, finite element analysis (FEA) is performed with a various test parameter using a commercial program ANSYS. Consequently, the general characteristics of node connectors the moment-rotation-curves are presented by considering a large deformation effect as well as a multi-linear material properties.

  • PDF

Seismic vulnerability and preservation of historical masonry monumental structures

  • Dogangun, Adem;Sezen, Halil
    • Earthquakes and Structures
    • /
    • v.3 no.1
    • /
    • pp.83-95
    • /
    • 2012
  • Seismic damage and vulnerability of five historical masonry structures surveyed after the 1999 Kocaeli and Duzce, Turkey earthquakes are discussed in this paper. The structures are located in two neighboring cities that have been struck by five very large ($M_s{\geq}7.0$) earthquakes during the $20^{th}$ century alone. Older masonry mosques with arches and domes and their masonry minarets (slender towers) were among the most affected structures in this highly seismic region. While some of the religious and historical structures had virtually no damage, most structures suffered significant damage or collapsed. In the city of Bolu, for example, approximately 600-year-old Imaret, 500-year-old Kadi, 250-year-old Sarachane, and 100-year-old Yildirim Bayezid mosques suffered substantial structural damage after the 1999 earthquakes. Another historical mosque surveyed in Duzce partially collapsed. Most common factors contributing to deterioration of historical structures are also presented. Furthermore, a brief overview of issues associated with analysis and modeling of historical masonry structures is provided.

Optimization of Grating Structures in Complex-Coupled MQW DFB Lasers with Absorptive Gratings (흡수 회절격자를 가지는 복소결합 다중양자우물 DFB 레이저의 회절격자 구조의 최적화)

  • Cho, Sung-Chan;Lee, Dong-Chan;Kim, Boo-Gyoun
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.7
    • /
    • pp.80-91
    • /
    • 1999
  • We present various optimal grating structures which give the low threshold gain, good modulation characteristics, small effective linewidth enhancement factor, and large fabrication tolerance in complex-coupled MQW DFB lasers with absorptive gratings. To obtain these, we calculate the complex coupling coefficients using the extended additional layer method and the threshold gain including the modal loss in the absorptive grating region for rectangular and trapezoidal gratings. Based on the comparison of the results for various possible absorptive grating structures, the design guidelines are presented to obtain the low threshold gain or large fabrication tolerance. Among the grating structures studied, the double grating structure consisting of the absorptive grating on the index grating has the largest fabrication tolerance for the threshold gain and the coupling strength. The fabrication tolerance for the coupling ratio is very large for all the grating structures studied.

  • PDF

A semi-active acceleration-based control for seismically excited civil structures including control input impulses

  • Chase, J. Geoffrey;Barroso, Luciana R.;Hunt, Stephen
    • Structural Engineering and Mechanics
    • /
    • v.18 no.3
    • /
    • pp.287-301
    • /
    • 2004
  • Structural acceleration regulation is a means of managing structural response energy and enhancing the performance of civil structures undergoing large seismic events. A quadratic output regulator that minimizes a measure including the total structural acceleration energy is developed and tested on a realistic non-linear, semi-active structural control case study. Suites of large scaled earthquakes are used to statistically quantify the impact of this type of control in terms of changes in the statistical distribution of controlled structural response. This approach includes the impulses due to control inputs and is shown to be more effective than a typical displacement focused control approach, by providing equivalent or better performance in terms of displacement and hysteretic energy reductions, while also significantly reducing peak story accelerations and the associated damage and occupant injury. For earthquake engineers faced with the dilemma of balancing displacement and acceleration demands this control approach can significantly reduce that concern, reducing structural damage and improving occupant safety.

Nonlinear Analysis of Precast Large Panel Structures Considering the Inelastic Properties of Horizontal Joints (수평접합부의 비탄성 특성을 고려한 프리캐스트 대형판넬 구조물의 비선형 해석에 관한 연구)

  • 정일영;최완철;송진규;강해관
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.45-52
    • /
    • 1995
  • The stability and integrity of precast large panel structures are analyzed with nonlinear mathematical model considering the inelastic properties of horizontal joints. In this research, an analysis for cyclic loading test was carried out by the macro model that idealized the horizontal joints as inelastic-nonlinear spring systems. As a results, the strain hardening ratio of shear slip element was estimated as about 0.05%- 0.2% of initial shear stiffness. And under lateral load, the rocking motion due ti overturning moment was dominant rather than shear slip motion in the behavior of precast structures.

  • PDF