• Title/Summary/Keyword: Large generator

Search Result 632, Processing Time 0.026 seconds

Root cause analysis of the abnormal wear on diesel engine crankpin and lubricant contamination (윤활유 오염과 디젤엔진의 크랭크핀 이상마모에 대한 원인 규명)

  • Seo, Jeongwoo;Park, Donghee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.854-867
    • /
    • 2014
  • In the circumstance that high oil price state is continued over the world, the investment in crude oil development by oil major is a trend of increasing. Recently the number of delivered drill-ship for 5 years has been sharply increased all over the world and about twice than that of past 30 years. As addition to the increase of the drill-ship demand, the operation of drill-ships which is delivered recently is about 3,000 meters, ultra deep sea, on average and the work area is expending. Accordingly the drilling system including the size and length of pipe for drilling has been bigger and bigger and the power supply equipment for operation system also has large capacity. Unlike merchant vessel, high power and high voltage of diesel generators are required for drill-ship for which the demand for V-type 320 bore of diesel generator has increased. It is on the raised that the importance of lubrication oil cleaning for diesel generator on drill-ship which has longer time for construction, and also long term low load operation is unavoidable during commissioning of equipments. Recently it was reported that engine crankpin was damaged due to the hard contact caused by the abnormal wear down(Cam wear) on crankpin and bearing. The same pattern of wear down was found through the inspection on series vessels and the other vessel under commissioning. The purpose of this paper is to analyze of the wear mechanism based on the observation and theories and objective research from actual cases and to prepare the counter measures to avoid foreseeable damage when the lubricating oil is not properly cleaned.

Study on Manufacturing Process of Hollow Main Shaft by Open Die Forging (자유단조공법을 통한 중공형 메인샤프트 제조공정에 관한 연구)

  • Kwon, Yong Chul;Kang, Jong Hun;Kim, Sang Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.2
    • /
    • pp.221-227
    • /
    • 2016
  • The main shaft is one of the key components connecting the rotor hub and gear box of a wind power generator. Typically, main shafts are manufactured by open die forging method. However, the main shaft for large MW class wind generators is designed to be hollow in order to reduce the weight. Additionally, the main shafts are manufactured by a casting process. This study aims to develop a manufacturing process for hollow main shafts by the open die forging method. The design of a forging process for a solid main shaft and hollow shaft was prepared by an open die forging process design scheme. Finite element analyses were performed to obtain the flow stress by a hot compression test at different temperature and strain rates. The control parameters of each forging process, such as temperature and effective strain, were obtained and compared to predict the suitability of the hollow main shaft forging process. Finally, high productivity reflecting material utilization ratio, internal quality, shape, and dimension was verified by the prototypes manufactured by the proposed forging process for hollow main shafts.

Delay Fault Test Pattern Generator Using Indirect Implication Algorithms in Scan Environment (스캔 환경에서 간접 유추 알고리즘을 이용한 경로 지연 고장 검사 입력 생성기)

  • Kim, Won-Gi;Kim, Myeong-Gyun;Gang, Seong-Ho
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.6
    • /
    • pp.1656-1666
    • /
    • 1999
  • The more complex and large digital circuits become, the more important delay test becomes which guarantees that circuits operate in time. In this paper, the proposed algorithm is developed, which enable the fast indirect implication for efficient test pattern generation in sequential circuits of standard scan environment. Static learning algorithm enables application of a new implication value using contrapositive proposition. The static learning procedure found structurally, analyzes the gate structure in the preprocessing phase and store the information of learning occurrence so that it can be used in the test pattern generation procedure if it satisfies the implication condition. If there exists a signal line which include all paths from some particular primary inputs, it is a partitioning point. If paths passing that point have the same partial path from primary input to the signal or from the signal to primary output, they will need the same primary input values which separated by the partitioning point. In this paper test pattern generation can be more effective by using this partitioning technique. Finally, an efficient delay fault test pattern generator using indirect implication is developed and the effectiveness of these algorithms is demonstrated by experiments.

  • PDF

Mass Flow Rate Measurement of Pulsating Flow in a Twin-Scroll Turbocharger (트윈스크롤 터보과급기에서 맥동유동의 질량유량 측정)

  • Chung, Jin-Eun;Jeon, Se-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.723-729
    • /
    • 2019
  • Turbochargers are an effective device to reduce the fuel consumption. In this study, the mass flow rate of pulsating flow in the twin-scroll turbocharger for the gasoline engine of passenger vehicles was measured. Pulsating flow was achieved using a pulse generator and the mass flow rate of the unsteady pulsating flow was analyzed by comparing it with those of the steady flow. The pulse generator consisted of a rotating upper plate and a fixed lower plate. To measure the mass flow rate of unsteady flow, the orifice flow meter equipped with the difference pressure transducer was used. To analyze the low speed performance of the turbocharger, the measurement was carried out in the speed of turbocharger from 60,000rpm to 100,000rpm. The mass flow parameters of the unsteady pulsating flow showed a large difference compared to those of the steady flow. Those of the unsteady flow showed the hysteresis loop surrounding the mass flow parameters of the steady flow and the maximum variation of the mass flow parameters were 5.0 times those of the steady flow. This phenomenon is the result of the filling and emptying the turbine volute space due to pulsating flow.

A Practical standard Air Flow Generator System to Calibrate and Compare Performance of Two Different Respiratory Air Flow Measurement Modules (호흡기류 계측모듈의 교정과 성능 비교를 위한 실용적인 표준기류 생성 시스템)

  • Lee, In-Kwang;Park, Mi-Jung;Lee, Sang-Bong;Kim, Kyoung-Ok;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.115-122
    • /
    • 2015
  • A standard air flow generator system was developed to generate air flows of various levels simultaneously applied to two different air flow transducer modules. Axes of two identical standard syringes for spirometer calibration were connected with each other and driven by a servo-motor. Linear displacement transducer was also connected to the syringe axis to accurately acquire the volume change signal. The user can select either sinusoidal or square waveform of volume change and manually input any volume as well as maximal flow rate levels ranging 0~3 l and 0~15 l/s, respectively. Various volume and flow levels were input to operate the system, then the volume signal was acquired followed by numerical differentiation to obtain the air flow signal. The measured volumes and maximal air flow rates were compared with the user input data. The relative errors between the user-input and the measured stroke volumes were all within 0.5%, demonstrating very accurate driving of the system. In case of the maximal flow rate, relatively large error was observed when the syringe was driven very fast within a very short time duration. However, except for these few data, most measured flow rates revealed relative errors of approximately 2%. When the measure and user-input stroke volume and maximal flow rate data were analyzed by linear regression analysis, respectively, the correlation coefficients were satisfactorily higher than 0.99 (p < 0.0001). These results demonstrate that the servo-motor controls the syringes with enough accuracy to generate standard air flows. Therefore, the present system would be very much practical for calibration process as well as performance evaluation and comparison of two different air flow transducer modules.

Development of Operation Control and AC/DC Conversion Integrated Device for DC Power Application of Small Wind Power Generation System (소형 풍력발전시스템의 직류전원 적용을 위한 운전제어 및 AC/DC변환 통합장치 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.179-184
    • /
    • 2019
  • In many countries, such as developing countries where electricity is scarce, small wind turbines in the form of Off Grid are an effective solution to solve power supply problems. In some countries, the expansion of power systems and the decline of electricity-intensive areas have led to the use of small wind power in urban road lighting, mobile communications base stations, aquaculture and seawater desalination. With this change, the size of the small wind power industry is expected to have greater potential than large-scale wind power. In the case of small wind power generators, the generator is controlled at a variable speed, and the voltage and current generated by the generator have many harmonic components. To solve this problem, the AC to DC converter to be studied in this paper is a three-phase step-up type converter with a single switch. The inductor current is controlled in discontinuous mode, and has a characteristic of having a unit power factor by eliminating the harmonic of the input current. The proposed converter is composed of LCL filter and three phase rectification boost converter at the input stage and a single phase full bridge for grid connection. It is a control system with energy storage system(ESS) that the system stabilization can be pursued against the electric power.

The Study of Operating Conditions by Establishing Density Currents Generator for Improving of Water Quality on Lake Water - With Focus on DO and Water Temperature - (호소수의 수질개선을 위한 DCG 설치시 운전조건에 관한 연구 - DO와 수온을 중심으로 -)

  • Lee, Young-Shin;Han, Kyung-Hee;Kim, Young-Kyu;An, Hyung-Chul;Shin, Sung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.286-294
    • /
    • 2014
  • The purpose of this study is to investigate the effects of applying density current generator (hereafter referred to as DCG to large lakes on the operating conditions of DCG, de-stratification, water quality improvement and inhibition of algae occurrence. As a result of a survey conducted to derive the optimum operating parameters of DCG in a condition to minimize eco-toxicity, the following conclusions were obtained. During the survey period, a marked stratification appeared in September to October 2011 and May 2012. At this time, the average depth of water to form thermocline was found to be $5{\pm}2$ m, so the location of discharge port for the operation of DCG was determined to be about 5 m below from the surface. To minimize the adverse effects of benthos and obtain the effect of water mixture at the time of water circulation, the mixing ratio of surface water and deep water was designed to be 3:1 by means of ecotoxicological assessment on the DCG operating characteristics. To select the appropriate operating hours for DCG, DCG was operated by 12 hr, 24 hr, 36 hr and 48 hr. As its result, the formation of thermocline did not occur during the operation of 36 hr. Also, It was effected that start reoperating from 3rd day after stop 2days under the condition of operated during 36 hr with calculated power consumption. Under the above conditions, the results of DO and water temperature analysis during the operation of DCG showed that the stratification, which was distinct previously, appeared to be weak, and relatively lower levels than those before operation were found as a result of water quality analysis on COD and chlorophyll-a, which leads to the conclusion that the water body is maintained at a stable condition due to the circulation of water by the occurrence of density current resulting from the operation of DCG.

Design and Implementation of Transmission Scheduler for Terrestrial UHD Contents (지상파 UHD 콘텐츠 전송 스케줄러 설계 및 구현)

  • Paik, Jong-Ho;Seo, Minjae;Yu, Kyung-A
    • Journal of Broadcast Engineering
    • /
    • v.24 no.1
    • /
    • pp.118-131
    • /
    • 2019
  • In order to provide 8K UHD contents of terrestrial broadcasting with a large capacity, the terrestrial broadcasting system has various problems such as limited bandwidth and so on. To solve these problems, UHD contents transmission technology has been actively studied, and an 8K UHD broadcasting system using terrestrial broadcasting network and communication network has been proposed. The proposed technique is to solve the limited bandwidth problem of terrestrial broadcasting network by segmenting 8K UHD contents and transmitting them to heterogeneous networks through hierarchical separation. Through the terrestrial broadcasting network, the base layer corresponding to FHD and the additional enhancement layer data for 4K UHD are transmitted, and the additional enhancement layer data corresponding to 8K UHD is transmitted through the communication network. When 8K UHD contents are provided in such a way, user can receive up to 4K UHD broadcasting by terrestrial channels, and also can receive up to 8K UHD additional communication networks. However, in order to transmit the 4K UHD contents within the allocated bit rate of the domestic terrestrial UHD broadcasting, the compression rate is increased, so a certain level of image deterioration occurs inevitably. Due to the nature of UHD contents, video quality should be considered as a top priority over other factors, so that video quality should be guaranteed even within a limited bit rate. This requires packet scheduling of content generators in the broadcasting system. Since the multiplexer sends out the packets received from the content generator in order, it is very important to make the transmission time and the transmission rate of the process from the content generator to the multiplexer constant and accurate. Therefore, we propose a variable transmission scheduler between the content generator and the multiplexer to guarantee the image quality of a certain level of UHD contents in this paper.

Limit Loads for Circular Wall-Thinned Feeder Pipes Considering Bend Angle (굽힘각도를 고려한 원형 감육이 발생한 중수로 피더관의 한계하중)

  • Bae, Kyung-Dong;Je, Jin-Ho;Kim, Jong-Sung;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.3
    • /
    • pp.313-318
    • /
    • 2012
  • In CANDU, feeder pipes supply heavy water to pressure tube and steam generator. Under service conditions, Flow-Accelerated Corrosion (FAC) produces local wall-thinning in the feeder pipes. The wall-thinning in these pipes affects the integrity of the piping system, as verified in previous research. This paper provides limit loads for wallthinned feeder pipes with $45^{\circ}$ and $60^{\circ}$ bend angles, and proposes an equation that predicts the limit loads for wallthinned feeder pipes with arbitrary bend angles. On the basis of finite element limit analyses, limit loads are obtained for wall-thinned feeder pipes under in-plane bending and internal pressure. There are two cases of in-plane bending: the in-plane closing direction and the in-plane opening direction. The material is considered the effect of the large deformation, so an elastic-perfectly-plastic material is assumed in the calculations.

Noisy Weighted Data Aggregation for Smart Meter Privacy System (스마트 미터 프라이버시 시스템을 위한 잡음 가중치 데이터 집계)

  • Kim, Yong-Gil;Moon, Kyung-Il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.3
    • /
    • pp.49-59
    • /
    • 2018
  • Smart grid system has been deployed fast despite of legal, business and technology problems in many countries. One important problem in deploying the smart grid system is to protect private smart meter readings from the unbelievable parties while the major smart meter functions are untouched. Privacy-preserving involves some challenges such as hardware limitations, secure cryptographic schemes and secure signal processing. In this paper, we focused particularly on the smart meter reading aggregation,which is the major research field in the smart meter privacy-preserving. We suggest a noisy weighted aggregation scheme to guarantee differential privacy. The noisy weighted values are generated in such a way that their product is one and are used for making the veiled measurements. In case that a Diffie-Hellman generator is applied to obtain the noisy weighted values, the noisy values are transformed in such a way that their sum is zero. The advantage of Diffie and Hellman group is usually to use 512 bits. Thus, compared to Paillier cryptosystem series which relies on very large key sizes, a significant performance can be obtained.