• 제목/요약/키워드: Large generator

Search Result 632, Processing Time 0.029 seconds

Development of an Automatic Two-Dimensional Mesh Generator using an Inward Offset Boundary Technique

  • Choi, Jin-Woo;Kim, Yohng-Jo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.2 no.4
    • /
    • pp.61-66
    • /
    • 2003
  • An excellent mesh construction is of Importance in yielding good results of finite element analysis. The new mesh generation algorithm, which offsets boundaries inward, was developed on the basis of a looping method. An user interface technique and automatic splitting lines which both divide a given domain into subdomains manually or automatically, were used. In addition, the separation method has advantages to prevent the large scale of element size and to control numbers of nodes and elements. This new mesh generation algorithm was proved in practice.

  • PDF

Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 분석)

  • Lee, Sang-Kil;Kim, Hee-Dong;Kim, Kwang-Hun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.152-155
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF

Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 분석)

  • Lee, Sang-Kil;Kim, Hee-Dong;Kim, Kwang-Hun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.199-202
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected. PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF

Development of Insulation Diagnosis System by On-Line Partial Discharge Measurement of Generator Stator Windings (발전기 고정자 권선의 운전중 부분방전 측정에 의한 절연진단 시스템 개발)

  • Shin, Byoung-Chol;Hwang, Don-Ha;Kim, Yong-Joo;Kim, Jeong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1025-1027
    • /
    • 1999
  • Recently, many researches on a diagnosis of stator winding insulation of large generators are reported. They mostly utilize a trend analysis of Partial Discharge (PD). In this paper, a novel on-line monitoring system for an insulation diagnosis is proposed. This system obtains the parameters such as Maximum Partial Discharge Magnitude (QM), Normalized Quantity Number (NQN) and Dynamic Stagnation Voltage (DSV) by continuous on-line monitoring of winding insulation. It is capable of diagnosing the insulation condition by analyzing the trend of PD and utilizing the database built by the system.

  • PDF

Steam Leak Detection by Using Image Signal (영상신호를 이용한 증기누설 검출 방법)

  • Choi, Young-Chul;Son, Ki-Sung;Jeon, Hyeong-Seop;Park, Jin-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.828-833
    • /
    • 2010
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. In this paper, we proposed the method for the detecting steam leakage by using image signal processing. Our basic idea come from heat shimmer which shine with a soft light that looks as if it shakes slightly. To test the performance of this technique, experiments have been performed for simple heat source and steam generator. Results show that the proposed technique is quite powerful in the steam leak detection.

Numerical Analysis of Hydrodynamic mass for various Tube Arrays in a circular cylindrical shell (원통 내부의 전열관 배열에 따른 유체부가질량특성 수치해석)

  • Yang, Keum-Hee;Ryu, Ki-Wahn;Park, Chi-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.693-699
    • /
    • 2011
  • The outermost SG tubes have more structural problems than inside tubes. Many studies have used a uniform added mass coefficient for all of the SG tubes during the FIV analysis. The purpose of this study is to find out the added mass coefficients for each tube in a cylindrical shell. When a number of tubes are increased, added mass coefficients are also increased. And added mass coefficients at outermost tubes are less than those of inside tubes. According to gap changes between outermost tube and cylindrical shell, added mass coefficients are decreased with increasing the gap. When the gap has very large value, it shows that the added mass coefficient is asymptotically converged to the value of the tube array in a free fluid field.

  • PDF

A New Approach to the Coherency-Based Dynamic Equivalence of Power Plants (Coherent 발전소들의 새로운 동태등가화 기법)

  • Park, Young-Moon;Jung, Jung-Won;Choi, Myeon-Song
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.162-166
    • /
    • 1990
  • This paper proposes a new method of the state reduction in dynamic equations of generators in large electric power system stability analysis. This method assumes study groups whose state trajectories we are interested in, coherency groups whose state trajectories are similar to the other state trajectories of generators in the same coherency group by a certain disturbance. By the weighted sum or the other method, the states of generators in one coherency group can be reduced to the equivalent states of an equivalent generator. This method is shown to be highly efficient in reducing the number of states with small error by the result of case study presented latter part of this paper.

  • PDF

Numerical Analysis with CFD Model for Site Designation in Urban Mountain Area (도심지 산악지형의 풍력발전 입지선정을 위한 전산유동해석 수치모의)

  • Lee, Hwa-Woon;Park, Soon-Young;Lee, Soon-Hwan;Kim, Dong-Hyuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.498-500
    • /
    • 2009
  • When we urgently need to develop and supply an alternative energy, wind power is growing with much interest because it has relative low cost for generating power and small area for wind turbine. To estimate the wind power resource, it is necessary to make an observation first. Although the large wind farm and resources are near coast and mountain area, the wind energy in urban area has the strong thing of direct access to power generator. In this study, we estimate the probability of wind energy in urban mountain area using A2C (Atmospheric to CFD) model, which is used for horizontally urban scale phenomena. In the steady state results, the site C is most suitable for wind power in the point of the only wind speed. But, estimating the TKE and vertical wind shear, the site B is showing the better results than the site C.

  • PDF

Study on the optimum system operation by considering the spinning reserve power (순동예비력을 고려한 계통의 최적운용방식에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.24 no.5
    • /
    • pp.97-102
    • /
    • 1975
  • This paper describes the result of a Study for the Optimum Operating method with Spinning reserve in case of outage of large generator unit to improve the system stability and prevent the system frequency drop. This is usually done by governor free operation, so we focused our attention to the operating Char acteristics of spinning reserve. Nexy, a study was made to mesure the upper limit of Spinning reserve and when this upper limit cannot match the required power, a relationship between the amount of spinning reserve and that of the load shedding requirement was searched with regard to several system operating conditions to use it in our future system operation. By this study, the optimum system operating method was recommended for reliable operation of power system.

  • PDF

Partial Scan Design based on Levelized Combinational Structure

  • Park, Sung-Ju
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.3
    • /
    • pp.7-13
    • /
    • 1997
  • To overcome the large hardware overhead attendant in the full scan design, the concept of partial scan design has emerged with the virtue of less area and testability close to full scan. Combinational Structure has been developed to avoid the use of sequential test generator. But the patterns sifted on scan register have to be held for sequential depth period upon the aid of the dedicated HOLD circuit. In this paper, a new levelized structure is introduced aiming to exclude the need of extra HOLD circuit. The time to stimulate each scan latch is uniquely determined on this structure, hence each test pattern can e applied by scan shifting and then pulsing a system clock like the full scan but with much les scan flip-flops. Experimental results show that some sequential circuits are levelized by just scanning self-loop flip-flops.

  • PDF