• 제목/요약/키워드: Large direct shear test

검색결과 94건 처리시간 0.029초

대형삼축압축시험 및 대형직접전단시험에 의한 사석재료의 전단강도 평가 (Comparison of Shear Strengths of Crushed Rock Determined by Large Triaxial Test and Direct Shear Test)

  • 신동훈;안태봉;이경필;이한출
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.259-264
    • /
    • 2002
  • In this study the shear strengths of a poorly grad ed rock material(d/sub max/≤50.8mm, C/sub u/=1.86) were determined by large direct shear test and large triaxial test. The obtained stress-strain curves by the above large shear tests for the rock materials are similar to the loose sand's or normally consolidated clay's curve, in which the peak strength does not appear obviously. And for the uniformly graded rock material the shear strength by large direct shear test may be overestimated around 1.54∼1.70 times that of large triaxial test.

  • PDF

굵은 입자가 포함된 풍화토의 전단강도 평가에 대한 실험연구 (An Experimental Study on the Evaluation of Shear Strength of Weathered Soil Containing Coarse Particles)

  • 김준석
    • 한국재난정보학회 논문집
    • /
    • 제20권1호
    • /
    • pp.169-176
    • /
    • 2024
  • 연구목적: 본 논문에서는 직접전단시험에서 시험시편의 규모 때문에 부득이 굵은 입자가 제외되는 문제 때문에 발생되는 전단강도의 차이를 분석하고자 직접전단시험을 실시하는 실험연구를 수행하였다. 연구방법: 최대직경 50mm의 굵은 골재가 포함된 3개의 풍화토를 대상으로 대형직접전단시험을 실시하였다. 또한 굵은 골재가 제외된 최대직경 5mm 시료를 이용하여 소형직접전단시험을 실시하였다. 연구결과: 소형직접전단시험의 경우 큰입자가 포함된 대형직접전단시험의 결과에 비하여 내부마찰각은 약2.3% 작은 값을 도출하여 비교적 큰 차이가 없었다. 점착력에서는 대형직접전단시험에 비하여 소형 직접전단시험이 약 80.3% 작은 값을 도출하여 비교적 큰 차이를 나타내었다. 결론: 대형직접전단시험에서 굵은 입자가 내부마찰각보다는 점착력에 큰 영향을 준 것으로 분석되었다. 따라서, 굵은 입자를 포함한 화강풍화토는 수직응력에 영향을 받지 않는 점착력과 같은 전단강도를 갖고 있는 것으로 판단된다. 본 연구에서는 일반적으로 사용되고 있는 굵은 입자를 제외한 소형직접전단시험은 굵은 입자의 효과를 제외함으로서 안전측의 결과를 제공하는 것으로 분석되었다.

대형 직접전단시험과 대형 삼축압축시험에 의한 조립재료의 전단강도 비교 (Comparison of Shear Strength of Coarse Materials Measured in Large Direct Shear and Large Triaxial Shear Tests)

  • 서민우;김범주;하익수
    • 한국지반환경공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.25-34
    • /
    • 2009
  • 댐이나 항만 건설시 재료로 사용되는 조립재는 입자크기가 일반 토사에 비해 매우 크기 때문에 이러한 재료에 대해서 전단시험을 수행할 때에는 가급적 대형 전단시험장치를 사용하는 것이 보다 정확한 결과를 얻기 위해 바람직하다. 대형 전단시험장치로는 일반적으로 대형 직접전단시험장치와 대형 삼축압축시험장치가 있으나 일반 토질시험장치와 비교해 제작과 보급, 운영 등의 어려움 때문에 현재까지 국내에서 두 시험장치를 사용하여 시험을 수행한 실적은 많지 않은 편이다. 본 연구에서는 댐 축조재로 사용되는 입경이 큰 조립재료를 대상으로 시료의 평균 입자크기와 공시체 크기, 연직응력(구속압) 조건 등에 차이가 있는 총 6개 case에 대해서 대형 직접전단시험과 대형 삼축압축시험을 수행하고 두 시험간 전단강도 특성의 차이를 비교하였다. Mohr-Coulomb 강도규준에 의한 전단강도를 기준으로, 대형 직접전단시험을 통해 산정된 전단강도가 대형 삼축압축시험을 통해 산정된 전단강도보다 전체적으로 크게 나타났으며 또한, 1,000kPa 수직응력에 대해 두 시험간 산정된 전단강도를 비교한 결과 대형 직접전단시험에 의한 전단강도가 대형 삼축압축시험에 의한 전단강도보다 약 10~70% 크게 나타나 입경이 작은 일반 토사와 비교해 그 차이가 크고, 대형 직접전단시험결과의 분산도가 상대적으로 높은 것으로 나타났다.

  • PDF

직접전단시험에 의한 모래의 전단강도에서 시편의 크기효과 (Scale Effects of the Specimen on Shear Strength of sand by Direct Shear Test)

  • 김준석;김지현
    • 한국재난정보학회 논문집
    • /
    • 제15권4호
    • /
    • pp.590-596
    • /
    • 2019
  • 연구목적: 직접전단시험의 문제점 중에 하나인 시험시편의 크기효과에 대하여 모래시료를 대상으로 실험적 연구를 수행하였다. 연구방법: 우리나라를 대표하는 모래인 주문진 표준사를 연구 대상으로 사용하였다. 상대밀도 50%, 60%, 70%, 80%에 대한 전단강도를 분석하기 위하여 대형직접전단시험을 수행한 후 소형직접전단기의 시험결과와 비교분석을 수행하였다. 연구결과: 상대밀도가 촘촘한(dense) 영역에서는 소형전단시험기의 내부마찰각이 비교적 큰 경향이 있는 것으로 분석되었다. 상대밀도가 중간(medium)정도의 영역에서는 대형전단시험기의 결과가 비교적 큰 경향이 있는 것으로 분석되었다. 결론: 모래흙에서 직접전단시험의 시료에 대한 크기 효과는 비교적 크지 않은 것으로 분석되었다.

대형직접전단시험과 대형삼축시험을 통한 석산골재의 전단거동 특성 비교 (Comparison of Shear Behavior for Quarry Blasted Rocks Based on Large Scale Direct Shear Test and Large Scale Triaxial Test)

  • 이대수;김경열;오기대
    • 한국지반공학회논문집
    • /
    • 제24권2호
    • /
    • pp.5-14
    • /
    • 2008
  • 국내 석산에서 생산되는 골재를 사용하여 대형삼축시험과 대형직접전단시험을 동시에 수행한 후 전단특성을 비교하였다. 비교를 위하여 시험조건을 가능한 일치시켰으며, 상대밀도를 50%, 70%, 90%의 세 가지로 변화시켜 시험을 수행하였다. 시험결과 응력-변형률 거동은 두 가지 시험에서 동일하게 나타나며, 전단강도는 상대밀도의 크기에 따라 시험방법별로 추세가 달라진다. 즉, 낮은 상대밀도에서는 대형직접전단시험의 내부마찰각이 대형삼축압축시험 결과 값에 비하여 작게 나타나고, 높은 상대밀도에서는 이 현상이 역전됨을 확인하였다.

링 전단시험기를 이용한 암석절리의 잔류강도 특성에 관한 연구 (A Study on Residual Stress Characteristics for Joint of Rock in Ring Shear Tests)

  • 권준욱;김선명;윤지선
    • 한국지반공학회논문집
    • /
    • 제16권6호
    • /
    • pp.35-41
    • /
    • 2000
  • Residual stress is defined as a minimum stress with a large displacement of specimens and the residual stress after peak shear stress appears with displacement volume but there is no provision to select the residual stress. In the previous study, residual stress was recorded when the change of shear load is small in the condition of the strain more than 15%. But, in this study, hyperbolic function((No Abstract.see full/text), b=experimental constant) of soil test is adapted to joint of rock and the propriety is investigated. In a landslide and landsliding of artificial slope, wedge failure of tunnel with a large displacement, tests are simulated from peak stress to residual stress for safety analysis. But now. direct shear stress and triaxial compressive tests are usually performed to find out characteristics of shear stress about joint. Although these tests get a small displacement, that data of peak stress and residual stress are used for safety analysis. In this study, we tried to determine failure criteria for joints of rock using ring shear test machine. The residual stress following shear behavior was determined by the result of ring shear test and direct shear test. In conclusion, after comparing the results of the two test, we found that cohesion(c) and internal friction angle(ø) of ring shear test are 30% and 22% respectively of those of the direct shear test.

  • PDF

전단마찰시험에 의한 섬유혼합토와 지오그리드 사이의 마찰 특성 평가 (Friction Properties between Fiber-Mixed Soil and Geogrid by Shear Friction Tests)

  • 조삼덕;김진만;이광우;안주환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.813-820
    • /
    • 2003
  • The shear friction tests using large direct shear test units were performed to evaluate the friction properties of fiber-mixed soil. The used materials and test conditions were flowing. Soils : SM and ML; mixing fibers : three types of polypropylene fibers(net type 38mm and 60mm, and line type 60mm), reinforcement : geogrid; mixing ratio:0.2% and 0.3%; degree of compaction : 85% and 95%. In the test results, the reinforcing effect of fiber mixed soil was confirmed.

  • PDF

대형전단시험에 의한 국내 도시폐기물의 전단특성 분석 (Analysis of Shear Strength of Domestic Municipal Wastes by Large Shear Test)

  • 정하익;이용수;정길수;홍승서
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.529-532
    • /
    • 1999
  • This paper presented the characteristics of shear strength of domestic municipal wastes including S landfill wastes. A series of large direct shear tests were peformed with waste specimens sampled from S landfill located in middle area of domestic land. Investigated items were cohesion and internal friction angle of shear strength parameter. The test result was compared with existing test data. The research results showed that cohesion 0.1296∼0.1340kg/$\textrm{cm}^2$ and angle of friction 22.1$^{\circ}$∼25.3$^{\circ}$for S landfill wastes, cohesion 0∼0.381kg/$\textrm{cm}^2$ and friction angle 22.1$^{\circ}$∼41.3$^{\circ}$ for domestic landfill wastes.

  • PDF

링 전단시험기를 이용한 연암의 절리에 대한 잔류강도 특성에 관한 연구 (A Study on Residual Stress Characteristics for Joint of Soft Rock in Ring Shear Tests)

  • 권준욱;김선명;윤지선
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.281-288
    • /
    • 2000
  • In this study, we tried to determine failure criteria for joints of soft rock using ring shear test machine. The residual stress fellowing shear behavior was determined by the result of ring shear test and direct shear test. Ring shear test with the specimens which cover a large deformation range was adapted to measure a residual stress, and was possible to present the peak stress to present the peak stress to the residual stress at the same time. Residual stress is defined a minimal stress of specimens with a large displacement and the result of the peak residual stress is shown by a size of displacement volume. Therefore, the residual stress in soil was decided by shear stress of maximum shear stress - shear displacement(angle) based on the test result of a hyperbolic function ((equation omitted), a, b = experimental constant). In this study, it was proved that the residual stress of rock joint can be determined by using of this method.

  • PDF

Direct Shear Test of Retrofit Anchors Using Deformed Reinforcement and Adhesive

  • Choi, Dong-Uk;Kim, Yong-Gon
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.91-99
    • /
    • 2000
  • A new type of retrof=t anchor bolt that uses deformed reinforcing bars and a commercial adhesive was developed and then an experimental study was carried out to determine the behavior of the anchors in direct shear. The steel-to-concl몫ete interface was tested. Plain concrete slabs with about 20-MPa compressive strength were used for 23 direct shear tests performed Test variables were anchor diameters (D16, D22. and D29) and edge effect. Three different shear tests were completed: simple shear, edge shear where anchors were pulled against the concrete core, and edge shear where anchors were pushed against the concrete cover In the simple and the edge shear tests where the anchors were pulled against the core, the theoretical dowel strength determined by (equation omitted) was achieved but with relatively large displacements. The shear resistances increased with the increasing displacements. In the edge shear test where the anchors were pushrd against the cover, the peak shear strengths signif=cantly lower than the theoretical dowel strength were determined due to cracks developed in concrete when the edge distance was 80 mm. The peak strengths were about 50% of the dowel strength for Dl6 bar. and about 25% or less of the dowel strength for D22 and D29 bars. Test results revealed that the edge shear where the anchor was pushed against the cover controled.

  • PDF