• Title/Summary/Keyword: Large Fire

Search Result 942, Processing Time 0.026 seconds

Effect of External Thermal Insulation Composite System with a Non-combustible Calcium Silicate Based Mineral on The Mitigation for Reducing Fast Spread of Flame (불연성 무기 단열재를 화재확산 방지구조로 적용한 외단열 마감시스템의 화재성능)

  • Lee, Jong-Chan;Park, Jong-Chul;Song, Hun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.397-403
    • /
    • 2016
  • As a building energy saving standard strengthened, The number of building installed external thermal insulation composite system(ETICS) using EPS insulation increased. But frequent fire accident in the buildings installed EIFS using EPS led to strengthening of building fire safety regulation. This study is for fire property of EPS ETICS reinforced with noncombustible calcium silicate-based mineral insulation as a fire spread prevention structure(FSPS). Fire test for large scale wall by ISO 13785-2 was applied and results showed EPS EIFS with FSPS got 3~8 times superior fire safety than normal EIFS by visual investigation. Temperature and heat flux measurement results, which data of upside of specimen were lower than downside, also supported fire safety of EIFS with FSPS.

A Study on the Escape Measures and Fire Protection System Improvement in Discount Stores (대형할인점의 피난대책 및 소방시설 개선방안에 관한 연구)

  • 홍성우;이영재
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.20-27
    • /
    • 2002
  • This study in focused on proposing the improvement plans for refuge and fire-fighting facilities in large shopping malls that are radically spreading. The main subjects are as follows. - The refuge measure for large shopping malls - Problems of installing the refuge facilities in stores and the solutions - Problems of installing the incendiary facilities in stores and the solutions - Problems of installing the indoor fire plug in stores and the solutions As result of the study, it has turned out that escape stairs which are set up according to the standard of size in the process of design plan, have to be decided for their amount, position, specification, etc, in consideration of the number of residents. It is also required to tighten a standard of installing a sprinkler instead of lightening the fire-fighting section in stores, considering obstacles due to facilities installed and procurement of the escape path. In addition, it needs to lighten a standard of installing the indoor fire plug, which is voluntarily set up at the store section incase of installing a sprinkler to make a practical fire-fighting facility available.

Fire resistance of high strength fiber reinforced concrete filled box columns

  • Tang, Chao-Wei
    • Steel and Composite Structures
    • /
    • v.23 no.5
    • /
    • pp.611-621
    • /
    • 2017
  • This paper presents an investigation on the fire resistance of high strength fiber reinforced concrete filled box columns (CFBCs) under combined temperature and loading. Two groups of full-size specimens were fabricated. The control group was a steel box filled with high-strength concrete (HSC), while the experimental group consisted of a steel box filled with high strength fiber concrete (HFC) and two steel boxes filled with fiber reinforced concrete. Prior to fire test, a constant compressive load (i.e., load level for fire design) was applied to the column specimens. Thermal load was then applied on the column specimens in form of ISO 834 standard fire curve in a large-scale laboratory furnace until the set experiment termination condition was reached. The test results show that filling fiber concrete can improve the fire resistance of CFBC. Moreover, the configuration of longitudinal reinforcements and transverse stirrups can significantly improve the fire resistance of CFBCs.

A Study on Fire Risk Analysis & Indexing of Buildings (건축물의 화재위험의 분석과 지수화에 관한 연구)

  • Chung, Eui-Soo;Yang, Kwang-Mo;Ha, Jeong-Ho;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.93-104
    • /
    • 2008
  • A successful fire risk assessment is depends on identification of risk, the analytical process of potential risk, on estimation of likelihood and the width and depth of consequence. Take the influence on enterprise into consideration, Fire risk assessment could carry out along the evaluation of the risk importance, the risk level and the risk acceptance. A large part of the limitation of choosing the risk assessment techniques impose restrictions on expense and time. If it is unnecessary high level risk assessment or Probabilistic Risk Assessment of buildings, in compliance with the Relative Ranking Method, Fire risk indexing and assessing is possible. As working-level technique, AHP method is useful with practical technique.

A State-of-art of Experimental Research and Calculated Models of Dowel-type Timber Connections in Fire

  • Luo, Jing;He, Minjuan;Li, Zheng
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.285-297
    • /
    • 2021
  • Fire safety is one of the most significant issues for the design of mid-rise and high-rise timber structures. A large number of experimental tests were conducted during the last three decades to investigate the fire performance of the dowel-type timber connections. Many influenced parameters (e.g. the thickness of the side timber, the load ratio, the fasteners type etc.) were considered in those experiments. Relevant calculated models were proposed by previous researchers to estimate the fire resistance of the connections. In this study, a series of experimental programs of dowel-type connections in fire are collected. Then, empirical formulas proposed by EN 1995-1-2, Fire safety in timber buildings, and previous researchers are presented and analyzed. The accuracy of those formulas is checked by comparisons between the experimental data and estimated results. The collected experimental research and empirical formulas can be used as the reference for the fire design of dowel-type timber connections in the future.

Analysis of Air Quality and the Management Plan for Exposure to Hazardous Substances in the Garage of a Fire Station (소방청사 차고지 공기질 분석 및 유해물질 노출 관리 방안)

  • Park, Je-Seop;Han, Dong-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.394-404
    • /
    • 2020
  • Objectives: The aims of this study are to derive the characteristics of diesel exhaust gas emissions generated during vehicle checking in the garage of fire stations and of the related improvement plans for proper air quality management. Methods: The researcher measured changes in the air quality inside garages according to the operating conditions of the exhaust facility and before and after vehicle checking at three fire stations. Results: During the checking of fire engines, a large volume of hazardous substances exceeding management standards were generated, and improvement of the discharge facilities was required for proper air quality management. Conclusions: It is necessary to study the hazard evaluation of firefighters' exposure to exhaust gas, to operate exhaust gas ventilation facilities, and to prepare technical standards for proper indoor air quality management.

Study on the Development of Qualification for Fire Identification and Estimation (화재감식평가 자격개발에 관한 연구)

  • Lee, Su-Kyung;Kim, Young-Chul;Oh, Hyung-Sool;Jung, Ki-Sin;Song, Dong-Woo;Kim, Tae-Hoon
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.78-85
    • /
    • 2010
  • Currently, there are various institutions performing fire investigation and identification, such as fire stations and police stations as well as institutes related to fire safety, etc. And the manpower working at the institutions reaches a large number of persons. But there is no objective index on the expertise of the persons. In this paper, we suggested the examination criteria through job analysis and the enforcement method of the exam system. And we developed suitable exam subjects and exam content specifications for qualification of fire identification and estimation that investigate a fire cause, combustion, escape circumstances and fire facilities at the scene of a fire, survey the fire damage and analysis fire cause, etc. It will increase the public trust to develop national technical qualification items of the fire identification and estimation engineer.

Analysis of Smoke Spread Effect Due to The Fire Location in Underground Subway-Station (대심도 역사의 화재위치에 따른 연기확산 영향 분석)

  • Jang, Yong-Jun;Koo, In-Hyuk;Kim, Jin-Ho;Nam, Seong-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2885-2890
    • /
    • 2011
  • Simulation study were performed for fire location effect on the smoke spread in the deeply-underground subway station(DUSS). In this research, Shingumho station (The line # 5, Depth: 46m) has been selected as case-study for the analysis of smoke-spread effect with the different fire location. Field test data measured for actual fan in DUSS was applied as a condition of a simulation. The whole station was covered in this analysis and 4 million grids were generated for this simulation. The fire driven flow was analyzed case by case to compare the smoke-spread effect according to the fire location. In order to enhance the efficiency of calculation, parallel processing by MPI was employed and LES(large eddy simulation) method in FDS code was adopted.

  • PDF

A Study on Performance-Based Design Enforcement (성능위주설계 시행의 개선방안)

  • Lee, Yang-Ju;Ko, Kyoung-Chan;Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.68-73
    • /
    • 2012
  • Performance-based design (PBD) for large scale high rise buildings has been enforced to secure fire and evacuation safety since July 1, 2011. As various types of trial and error were expected in the early stage, to suggest solutions to the problems that might be followed by the enforcement, the regulations on PBD were reviewed and a questionnaire survey to fire protection specialists was carried out. It was confirmed that PBD is required for large scale apartment buildings, and specific and detail criteria for PBD methodology and evaluations, education for PBD to personnel who design and evaluate are also in need.

A Design of Fire Detection System based on Infrared Thermal Imaging & CCD Camera (적외선 열영상 및 CCD 카메라 기반 화재감지 시스템 설계)

  • Kim, Tae Wan;Choi, Chang Yong;Lee, Dong Myung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.597-598
    • /
    • 2013
  • A lot of fire and crime accidents are caused to a significant national loss. For example, the network and power facilities in national industry facilities, the fire risk region in large scale factories such as nuclear and thermal power plants, large-sized buildings, cultural properties, metal and steel mills, chemical plants, oil refineries. The development of a fire detection system that can detects the temperature and movement of objects as high-level quality is essential to prevent these incidents and accidents fundamentally. In this paper, the fire detection system based on infrared thermal imaging & CCD camera id designed to solve these problems.

  • PDF