• Title/Summary/Keyword: Large Field Density Test

Search Result 42, Processing Time 0.027 seconds

The Estimation of Volume Conversion Factor of Rock Fill using Field Density Test (현장밀도시험을 이용한 암성토 체적환산계수 산정에 관한 연구)

  • Park, Jong-Beom;Ma, Myong-Soo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • In this study, the field density test was conducted as a volume conversion factor for the design of the excavation soil of the blasting rock. As a result of the field density test, the average volume conversion factor of rock was 1.001, which was smaller than the volume conversion factor of weathered rock 1.1. In the case of rock filled soil, the causes of the increase and decrease of the volume of the soil are provided by various phenomena. However, the specific techniques such as investigation and test methods are insufficient. Therefore, it was confirmed that the method of field density test is very useful method.

The Study of Compaction Characteristics of Cataclasite Fill Material using Large and Standard Compaction Tests (대형다짐시험 및 표준다짐시험을 이용한 파쇄암 성토재의 다짐특성 연구)

  • Jeoung, Jae-Hyeung;Ryu, Sang-Hun;Choi, Dong-Yub;Park, Kwang-Sik;Hwang, Sung-Pil
    • The Journal of Engineering Geology
    • /
    • v.26 no.4
    • /
    • pp.439-445
    • /
    • 2016
  • The new airports apply the systematic runway foundation construction to build the high quality runways in order to take the leading position to win future aerial demands and stay ahead of competitors. This study is intended to supplement the weakness of existing standard compaction test to minimize residual settlement of lower weak foundation during operation of passenger berthage. The fill material was sampled from 4 construction sites using the fill material with diameter of 100mm or less, and the standard compacting test (KS F 2312), large circular mold compacting test, and water-replacement field density test (ASTM D 5030) were conducted. The regression analysis of correlation of the field density test and the standard indoor compaction test showed the unreliable value at P-value of 0.05, and the regression analysis of the field density test and the large indoor compaction test showed the high correlation with R value of 0.8878. It is judged that the construction of overall uniform quality can be assured as the site condition is truly reflected only if the compacting test method is selected in consideration of maximum size of fill material when evaluating the maximum dry density used in design and construction.

Evaluation of Empirical Design Factors of Coarse Grained Material through Large Scale Shear Test (대형전단시험을 통한 댐제체용 조립재료의 경험적 설계정수에 대한 평가)

  • Oh, Gi-Dae;Kim, Kyoung-Yul;Lee, Dae-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.777-783
    • /
    • 2006
  • The coarse grained materials are used in various construction field such as express way back fill, Dam etc. Especially, for dam construction, a huge mount of rock fill materials are needed, so around domestic stony mountains are generally developed to produce materials. Not an accurate theory, but design criteria is based on empirical factors that were constructed in advance for design of dam especially Concrete Face Rockfill Dam(CFRD). Considering the post facts, the modified design criteria are essential in the future with more theoretical and experimental ways. In this study, large scale direct shear tests are performed with various relative density conditions on coarse grained material of Yecheon area to compare test results and general CFRD design factors.

  • PDF

Conceptual design and fabrication test of the HTS magnets for a 500 W-class superconducting DC rotating machine under 77 K

  • Choi, J.;Kim, S.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.35-38
    • /
    • 2021
  • Conventional direct current (DC) rotating machines are usually used for crane and press machine using high torque in metal and steel industries, because of a constant output power along variable rotating speed. A general DC motor with permanent field magnets could not increase a magnetic flux density at a gap between armature coils and field magnets. However, a superconducting DC motor has field magnets composed with high temperature superconducting (HTS) coils and it could increase the magnetic flux density at the gap to over 10 times than those of a general DC motor by control the excitation current into HTS coils. The superconducting DC motor could be operated with extremely high torque and constant output power at a low rotational speed. In this paper, a 500 W superconducting DC rotating machine was conceptually designed with a LN2 (Liquid Nitrogen) cooling method and the operation characteristics results of HTS field magnets were presented. The two no-insulation HTS magnets for a 500 W superconducting DC rotating machine were fabricated. The excitation current for the HTS magnets could be controlled from 0 to 40 A. This test results will be available to design large-sized HTS magnets for a number of hundred kW class superconducting DC rotating machine under LN2 cooling system.

Applying Alcock-Paczynski Test to the Large Scale Structure

  • Li, Xiao-Dong;Park, Changborm;Romero, Jaime Forero
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.58.1-58.1
    • /
    • 2013
  • The main idea of the Alcock-Paczynski (AP) test is that, if we use a wrong distance-redshift relation to infer the shape of a spherical object in the Universe, this object may look non-spherical. To probe the cosmic expansion history through the AP test, the key point is to find something which is known as spherical in the Universe. We propose two possible ways applying the AP test to the large scale structure (LSS): 1) Based on the observed galaxies or quasars, one built up the beta-skeleton tracing the LSS, and investigating the inhomogeneity of the connections; 2) One reconstructs the smoothed density-contrast gradient field based on LSS observations, and investigating the inhomogeneity of the gradient vectors. Compared with some existed methods probing AP effect through 2-point correlation function, galaxy pairs, or voids, our methods have various advantages: 1) The information of both the high and low dense regions of the LSS are taken into account. 2) The redshift space distortion as the main contamination to the AP effect can be easily removed.

  • PDF

Estimation of Magnetization loss of HTS wires with Different Current Density (전류 밀도가 다른 선재들의 자화손실 특성 평가)

  • Lim, H.;Yoon, K.;Lee, H.;Cha, G.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.72-75
    • /
    • 2007
  • Magnetization loss of HTS wire is strongly dependent on the critical current density and the aspect ration of the HTS wire. This paper presents the magnetization loss of stacked BSCCO wire and stacked YBCO wires which had different critical current densities. Width of the BSCCO wire was 4mm and widths of two YBCO wires were 4mm and 8mm. Single wire, two stacked three stacked and four stacked wires were fabricated and tested. Ratio of magnetization loss of BSCCO wire to YBCO wire was presented at single wire. For stacked wire, ratio of magnetization loss of single wire to stacked wire was presented. Test results shows that magnetization losses of stacked wires were greater than that of single wire at large high magnetic field above critical magnetic field.

Uniform large scale cohesionless soil sample preparation using mobile pluviator

  • Jamil, Irfan;Ahmad, Irshad;Ullah, Wali;Junaid, Muhammad;Khan, Shahid Ali
    • Geomechanics and Engineering
    • /
    • v.28 no.5
    • /
    • pp.521-529
    • /
    • 2022
  • This research work deals with the development of air pluviation method for preparing uniform sand specimens for conducting large scale laboratory testing. Simulating real field conditions and to get reliable results, air pluviation method is highly desirable. This paper presents a special technique called air pluviation or sand raining technique for achieving uniform relative density. The apparatus is accompanied by a hopper, shutters with different orifice sizes and numbers and set of sieves. Before using this apparatus, calibration curves are drawn for relative density against different height of fall (H) and shutter sizes. From these calibration curves, corresponding to the desired relative density of 60%, the shutter size of 13mm and height of fall of 457.2 mm, are selected and maintained throughout the pluviation process. The density obtained from the mobile pluviator is then verified using the Dynamic Cone Penetrometer (DCP) test where the soil is poured in the box using defined shutter size and fall height. The results obtained from the DCP test are averaged as 60±0.5 which was desirable. The mobile pluviator used in this research is also capable of obtaining relative densities up to 90%. The instrument is validated using experimental and numerical approach. In numerical study, Plaxis 3D software is used in which the soil mass is defined by 10-Node tetrahedral elements and 6-Node plate is used to simulate plate behavior in the validation phase. The results obtained from numerical approach were compared with that of experimental one which showed very close correlation.

Critical Characteristics Estimation of a Large-Scale HTS Wind Turbine Generator Using a Performance Evaluation System

  • Kim, Taewon;Woo, Sang-Kyun;Kim, Changhyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.229-233
    • /
    • 2019
  • Large-scale High Temperature Superconducting (HTS) wind power generators suffer from high electromagnetic force and high torque due to their high current density and low rotational speed. Therefore, the torque and Lorentz force of HTS wind power generators should be carefully investigated. In this paper, we proposed a Performance Evaluation System (PES) to physically test the structural stability of HTS coils with high torque before fabricating the generator. The PES is composed of the part of a pole-pair of the HTS generator for estimating the characteristic of the HTS coil. The 10 MW HTS generator and PES were analyzed using a 3D finite element method software. The performance of the HTS coil was evaluated by comparing the magnetic field distributions, the output power, and torque values of the 10 MW HTS generator and the PES. The magnetic flux densities, output power, and torque values of the HTS coils in the PES were the same as a pole-pair of the 10 MW HTS generator. Therefore, the PES-based evaluation method proposed in this paper can be used to estimate the critical characteristics of the HTS generator under high magnetic field and high torque before manufacturing the HTS wind turbines. These results will be used effectively to research and manufacture large-scale HTS wind turbine generators.

Behavior of Geotextile Tube for Erosion Control (침식방지를 위한 토목섬유튜브의 거동 분석)

  • Chang, Yong-Chai;Son, Ka-Young;Lee, Seung-Eun;Kim, Sang-Jin;Kim, Suk-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.5
    • /
    • pp.5-12
    • /
    • 2012
  • Geotextile tube method is the latest application process to construct a variety of civil structures such as river and coastal structures by using geotextile which is a high polymer synthetic fiber. In this paper, laboratory tests and field tests were conducted in order to identify the behavior, stability and application possibility of geotextile tube which prevents the erosion of coastal sand. As a result of large-scale direct shear test, which is one of laboratory tests, the increase in friction angle was shown as the relative density increased, and friction angle of sand/geotextile was larger than that of sand/sand. As a result of field test, the behavior and stability during construction and after construction were identified through measurement, and the effect of preventing erosion was confirmed.

Testing Web Feeding Model for Star Formation in Galaxy Clusters in the COSMOS Field

  • Ko, Eunhee;Im, Myungshin;Lee, Seong-Kook;Hyun, Minhee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.52.3-53
    • /
    • 2021
  • It is yet to be understood what controls the star formation activity in high-redshift galaxy clusters. One recently proposed mechanism is that the star formation activity in galaxy clusters are fed by gas and galaxies in large-scale structures surrounding them, which we call as "web feeding model". Using galaxies in the COSMOS2015 catalog, with mass completeness at log(M/M⦿)≥9.54 and reliable photometric redshift data (σΔz/(1+z) ≲ 0.01), we study the star formation activities of galaxy clusters and their surrounding environment to test the web feeding model. We first identify the overdense regions with number density exceeding the 4σ-level from photometric redshift data as galaxy clusters, and we find that they are well matched with clusters identified in the X-ray extended source catalog. Furthermore, we identify galaxy large scale structures, and will present the correlation or anti-correlation between quiescent galaxy fraction, an indicator of star-forming activity, and the prevalence of galaxy large scale structures.

  • PDF