• 제목/요약/키워드: Large Deviations

검색결과 202건 처리시간 0.028초

PFT법에 의한 수직적 3 ZONE 분할 조건에서의 환기량 측정 (Ventilation Measurement with PFT in Three-storied Detached House)

  • 김훈
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.506-515
    • /
    • 2013
  • The PFT (PerFluorocarbon Tracergas Technique) is of advantage to field surveys for evaluating the ventilation condition, due to its simplicity and convenience. On the other hand, it requires researchers to make some additional considerations that include uncertainties, such as the substance concentration distribution in indoor air, representativeness of a sampler, deviation of emission sources, and analysis error. In this study, the PFT and $CO_2$ tracer gas methods were applied simultaneously, to evaluate the accuracy of PFT on six ventilation conditions in the three-storied detached house. The air exchange and the outdoor air introduction a between and into zones were measured. As the results, deviations of PFT concentration distributions were observed at a sufficiently low level for an accurate determination for a house where the interior height was large, and there were relatively many partition walls. However, when a uniform airflow appeared in the indoor air, it was also validated that the indoor air would be exhausted without sufficient mixing, and consequently the measurement error of the PFT would be large.

Wind loads and wind-resistant behaviour of large cylindrical tanks in square-arrangement group. Part 1: Wind tunnel test

  • Liu, Qing;Zhao, Yang;Cai, Shuqi;Dong, Shilin
    • Wind and Structures
    • /
    • 제31권6호
    • /
    • pp.483-493
    • /
    • 2020
  • Large cylindrical floating-roof tanks, constructed as oil containers, are usually distributed regularly in open area and easily exposed to severe wind loads. However, wind pressures around these grouped squat tanks appear to have not been clearly given in design codes or thoroughly studied in existing researches. This paper conducts a detailed investigation on wind loads on the external wall of a four-tank group in square arrangement. To achieve that, wind tunnel tests are carried out on both empty and full tank groups, considering various wind angles and spacing. Results show that 3 regions in elevation can be identified on the tank shell according to the circumferential wind pressure distribution. The upper 2 regions cover a relatively small portion of the shell where excessive negative pressures are spotted, setting an alarm to the design of the top angle and stiffening rings. By comparing results on grouped tanks to those on an isolated tank, grouping effects concerning wind angle, tank position in group and spacing are discussed. Deviations on pressure distributions that will compromise structural safety are outlined, including the increase of negative pressures, the shift of maximum pressure locations as well as the change of positive pressure range. And, several potentially unfavourable wind pressure distributions are selected for further analyses.

최적 변조제어기를 이용한 전력시스템의 부하주파수 제어에 관한 연구 (A Study on the Load Frequency Control of Power System Using an Optimal Modulation Controller)

  • 정형환;허동렬;정문규;주석민;이준탁
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.299-306
    • /
    • 2002
  • The load frequency control(LFC) of power system is one of important subjects in view of system operation and control. That is, even though the rapid load disturbances are applied to the given power system, the stable and reliable power should be supplied to the users, converging unconditionally and rapidly the frequency deviations and the tie-line power flow ones of each area into allowable boundary limits. Nonetheless of such needs, if the internal parameter perturbation and the sudden load variation are given, the unstable phenomena of power systems can be often brought out because of the large frequency deviation and the unsuppressible power line one. So, an optimal modulation controller for UC of multi-area power system is designed by a recursive algorithm that determines the state weighting matrix Q of a linear quadratic performance criterion. The optimal modulation controller is based on optimal control and can obtain the exact dynamic response of the UC of multi-area power system in the time domain. The performances of the resultant optimal modulation control, that is, the steady-state deviations of frequency and tie-line power flow and the related dynamics, were investigated and analyzed in detail by being applied to the UC of multi-area power system in the perturbations of predetermined internal parameters. Through the simulation results tried variously in this paper for disturbance of stepwise load changes, the superiorities of the proposed optimal modulation controller in robustness and stability were proved.

버스도착시간 정보에 대한 연구 (A Study on Bus Arrival Information for BIS)

  • 고승영
    • 대한교통학회지
    • /
    • 제20권5호
    • /
    • pp.175-181
    • /
    • 2002
  • 본 연구는 BIS 시스템에서 제공되는 버스도착안내정보의 형태에 대한 특성을 검토하고, 이를 기초로 도착예정시간을 안내하는 경우 안내도착예정시간의 함수로 총대기시간을 구하고 최적 안내도착예정시간을 도출하는 모형을 개발하였다. 안내도착예정시간의 함수로 버스도착을 안내된 도착예정시간 보다 일찍 도착하는 조기도착과 늦게 도착하는 지연도착으로 구분하여 각각의 경우에 대한 대기시간의 합인 총대기시간을 함수화하였다. 모형 및 사례연구를 통하여 BIS 시스템에서 평균도착시간이 안내해야할 최적의 도착예정시간이 아닐 수도 있으며, 이와는 다른 최적 안내도착예정시간이 존재함을 알 수 있었다. 최적 안내도착예정시간은 작은 범위의 표준편차와 아주 큰 표준편차의 버스통행시간에 대해서 평균도착시간에 가까워져야 하고, 중간의 표준편차 범위에서는 표준편차가 클수록 늦게 안내되어야 한다는 결론을 도출하였다.

HFC-32/143a와 HFC-143a/134a계의 기-액상평형 실험에 관한 연구 (Investigation of vapor-liquid equilibrium of HFC-32/143a and HFC-143a/134a systems)

  • 김창년;박영무
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.91-99
    • /
    • 1999
  • Vapor-liquid equilibrium apparatus is designed and set up. The equilibrium data of two binary systems, HFC-32/143a and HFC-143a/134a, are measured. Fifteen equilibrium data for HFC-32/143a and HFC-143a/134a systems are measured over the temperature range 263.15~283.15K at 10K interval and the composition range 0.10~0.80, respectively. And vapor-liquid equilibrium data are calculated using equation of state and correlation of activity coefficient and compared with the present data. Equation of state is used CSD and RKS equations and correlation of activity coefficient is used Margules' and Van Ness and Abbott's correlations. Real behavior of HFC-32/143a system has very large deviation with Raoult's rule which is ideal behavior. But real behavior of HFC-143a/134a system is similar to ideal behavior. The calculated data from CSD equation are compared with the data in the open literatures and the calculated data from REFPROP. In the results for REFPROP, the relative deviations of bubble point pressure for HFC-32/143a system are within -2.16~0.84% for CSD equation and within -0.20~1.10% for RKS equation. And the relative deviations of bubble point pressure for HFC-143a/134a system are within -0.45~0.12% and -0.20~2.8% for CSD and RKS equations, respectively.

  • PDF

자기조정 뉴로-퍼지제어기를 이용한 다지역 전력시스템의 부하주파수 제어 (Load Frequency Control of Multi-area Power System using Auto-tuning Neuro-Fuzzy Controller)

  • 정형환;김상효;주석민;허동렬;이권순
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권3호
    • /
    • pp.95-106
    • /
    • 2000
  • The load frequency control of power system is one of important subjects in view of system operation and control. That is even though the rapid load disturbances were applied to the given power system, the stable and reliable power should be supplied to the users, converging unconditionally and rapidly the frequency deviations and the tie-line power flow one on each area into allowable boundary limits. Nonetheless of such needs, if the internal parameter perturbation and the sudden load variation were given, the unstable phenomenal of power system can be often brought out because of the large frequency deviation and the unsuppressible power line one. Therefore, it is desirable to design the robust neuro-fuzzy controller which can stabilize effectively the given power system as soon as possible. In this paper the robust neuro-fuzzy controller was proposed and applied to control of load frequency over multi-area power system. The architecture and algorithm of a designed NFC(Neuro-Fuzzy Controller) were consist of fuzzy controller and neural network for auto tuning of fuzzy controller. The adaptively learned antecedent and consequent parameters of membership functions in fuzzy controller were acquired from the steepest gradient method for error-back propagation algorithm. The performances of the resultant NFC, that is, the steady-state deviations of frequency and tie-line power flow and the related dynamics, were investigated and analyzed in detail by being applied to the load frequency control of multi-area power system, when the perturbations of predetermined internal parameters. Through the simulation results tried variously in this paper for disturbances of internal parameters and external stepwise load stepwise load changes, the superiorities of the proposed NFC in robustness and adaptive rapidity to the conventional controllers were proved.

  • PDF

Validation and selection of GCPs obtained from ERS SAR and the SRTM DEM: Application to SPOT DEM Construction

  • Jung, Hyung-Sup;Hong, Sang-Hoon;Won, Joong-Sun
    • 대한원격탐사학회지
    • /
    • 제24권5호
    • /
    • pp.483-496
    • /
    • 2008
  • Qualified ground control points (GCPs) are required to construct a digital elevation model (DEM) from a pushbroom stereo pair. An inverse geolocation algorithm for extracting GCPs from ERS SAR data and the SRTM DEM was recently developed. However, not all GCPs established by this method are accurate enough for direct application to the geometric correction of pushbroom images such as SPOT, IRS, etc, and thus a method for selecting and removing inaccurate points from the sets of GCPs is needed. In this study, we propose a method for evaluating GCP accuracy and winnowing sets of GCPs through orientation modeling of pushbroom image and validate performance of this method using SPOT stereo pair of Daejon City. It has been found that the statistical distribution of GCP positional errors is approximately Gaussian without bias, and that the residual errors estimated by orientation modeling have a linear relationship with the positional errors. Inaccurate GCPs have large positional errors and can be iteratively eliminated by thresholding the residual errors. Forty-one GCPs were initially extracted for the test, with mean the positional error values of 25.6m, 2.5m and -6.1m in the X-, Y- and Z-directions, respectively, and standard deviations of 62.4m, 37.6m and 15.0m. Twenty-one GCPs were eliminated by the proposed method, resulting in the standard deviations of the positional errors of the 20 final GCPs being reduced to 13.9m, 8.5m and 7.5m in the X-, Y- and Z-directions, respectively. Orientation modeling of the SPOT stereo pair was performed using the 20 GCPs, and the model was checked against 15 map-based points. The root mean square errors (RMSEs) of the model were 10.4m, 7.1m and 12.1m in X-, Y- and Z-directions, respectively. A SPOT DEM with a 20m ground resolution was successfully constructed using a automatic matching procedure.

모바일 스마트 장치 배터리의 잔여 시간 예측 향상을 위한 데이터 전처리 프레임워크 (A Data Preprocessing Framework for Improving Estimation Accuracy of Battery Remaining Time in Mobile Smart Devices)

  • 탁성우
    • 한국정보통신학회논문지
    • /
    • 제24권4호
    • /
    • pp.536-545
    • /
    • 2020
  • 모바일 스마트 장치 배터리의 잔여 시간을 예측하기 위해 범용 통계적 회귀 기법을 적용한 경우, 배터리 잔량별 배터리 사용 시간의 편차가 커질수록 범용 통계적 회귀 기법의 예측 정확도가 낮아진다. 따라서 범용 통계적 회귀 기법의 예측 정확도를 향상시키기 위해서는 배터리 잔량별 배터리 사용 시간의 편차가 큰 원 측정 데이터를 가공 처리하여 정제된 데이터로 변환시키는 작업이 필요하다. 이에 본 논문에서는 원 측정 데이터를 정제된 데이터로 가공 처리하는 데이터 전처리 프레임워크를 제안하였다. 제안한 프레임워크를 통해 가공 처리하여 정제된 데이터를 범용 통계적 회귀 기법에 적용한 결과, 범용 통계적 회귀 기법의 예측 정확도가 향상됨을 확인하였다.

풍력발전기의 설비이용률 계산을 위한 확률밀도함수의 비교 (Comparison of Probability Density Functions for Caculation of Capacity Factors of Wind Turbine Generator)

  • 강택근;허종철;좌종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1338-1341
    • /
    • 2002
  • The Weibull probability density function and the Rayleigh function are compared by analyzing the relations of the capacity factors which are compared the actual wind speed frequency curve with which are modelled using the probability density functions with different mean wind speeds. For this analysis, the wind speed means of arithmetic, root mean square, cubic mean cuberoot, and standard deviations are computed from the measured wind speed data of a specific site and the coefficients of probability density functions are calculated. The capacity factors for Vestas 850[kW] wind turbine are calculated and analyzed. The results shows that the wind speed frequency curve by Rayleigh function is more close to the actual curve than by Weibull function. The more the wind speed frequency curve is close to the actual one, the more the capacity factors become large values.

  • PDF

세관내 R-22와 R-410A의 응축 압력강하 (The Condensation Pressure Drop of R-22 and R-410A in Small Diameter Tube)

  • 손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제19권2호
    • /
    • pp.156-162
    • /
    • 2008
  • The condensation pressure drop for R-22 and R-410A flowing in a small diameter tube was investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and coolant flowing in the annulus. The test section consists of 1220 mm length with horizontal copper tube of 3.38 mm outer diameter and 1.77 mm inner diameter. The refrigerant mass fluxes ranged from 450 to $1050\;kg/m^2{\cdot}s$ and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main experimental results were summarized as follows : In the case of two-phase flow, the pressure drop increases with increasing mass flux and decreasing quality. The pressure drop of R-22 is slightly higher than that of R-410A for the same mass flux. Most of correlations proposed in the large diameter tube showed enormous deviations with experimental data.