• Title/Summary/Keyword: Large Corporation

Search Result 936, Processing Time 0.026 seconds

Development and Installation of Large-scale Geotechnical Testing Facilities (대형 지반시험장비의 개발 및 구축)

  • Seo, Min-Woo;Ha, Ik-Soo;Kim, Yong-Seong;Park, Dong-Soon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1233-1240
    • /
    • 2005
  • As the geotechnical technologies have grown, the size of civil structures has become bigger than before, thereby requiring large-scale geotechnical testing equipments which can evaluate the mechanical behavior of large size testing materials such as gravel, crushed rock and so on. These kind of large testing equipments are usually used to evaluate the mechanical characteristics of large size material which are applied in the large infra structures like dam, seashore structure, coastal landfill, soil-structure interaction and seismic response of large-scale structure. In this research, state-of-the-art information in the field of geotechnical engineering was collected and summarized for such large-scale experimental equipments as large-scale geo-centrifuge, large-scale triaxial testing machine, large-scale direct shear testing apparatus and large-scale oedometer.

  • PDF

Query Normalization Using P-tuning of Large Pre-trained Language Model (Large Pre-trained Language Model의 P-tuning을 이용한 질의 정규화)

  • Suh, Soo-Bin;In, Soo-Kyo;Park, Jin-Seong;Nam, Kyeong-Min;Kim, Hyeon-Wook;Moon, Ki-Yoon;Hwang, Won-Yo;Kim, Kyung-Duk;Kang, In-Ho
    • Annual Conference on Human and Language Technology
    • /
    • 2021.10a
    • /
    • pp.396-401
    • /
    • 2021
  • 초거대 언어모델를 활용한 퓨샷(few shot) 학습법은 여러 자연어 처리 문제에서 좋은 성능을 보였다. 하지만 데이터를 활용한 추가 학습으로 문제를 추론하는 것이 아니라, 이산적인 공간에서 퓨샷 구성을 통해 문제를 정의하는 방식은 성능 향상에 한계가 존재한다. 이를 해결하기 위해 초거대 언어모델의 모수 전체가 아닌 일부를 추가 학습하거나 다른 신경망을 덧붙여 연속적인 공간에서 추론하는 P-tuning과 같은 데이터 기반 추가 학습 방법들이 등장하였다. 본 논문에서는 문맥에 따른 질의 정규화 문제를 대화형 음성 검색 서비스에 맞게 직접 정의하였고, 초거대 언어모델을 P-tuning으로 추가 학습한 경우 퓨샷 학습법 대비 정확도가 상승함을 보였다.

  • PDF

Insulation Performance and BOR of Pressurized Large-capacity Liquid Hydrogen Storage Tank (가압식 대용량 액체수소 저장탱크의 단열 성능과 BOR)

  • HEUNG SEOK SEO;YEONGBUM LEE;DONGHYUK KIM;CHANGWON PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.6
    • /
    • pp.650-656
    • /
    • 2023
  • In order to efficiently control boil-off rate of a liquefied hydrogen tank, the important thing is to maintain an appropriate vacuum level. however, compared to small and medium-sized storage tank, it is very difficult to create and maintain vacuum in large-capacity storage tanks. In this study, we aim to determine the target level of future large-capacity storage tank technology development and secure basic data on performance test methods by analyzing the corelation between evaporation gas and thermal conductivity of liquefied hydrogen storage tanks.

High Performance of Crystallization for LPTS TFTs Using Solid Green Laser

  • Nishida, K.;Kawakami, R.;Izawa, J.;Kawaguchi, N.;Matsuzaka, F.;Masaki, M.;Morita, M.;Yoshinouchi, A.;Kawasaki, Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.911-914
    • /
    • 2007
  • We developed the laser annealing system using green laser of 261W(5kHz) and 75.5mJ/pulse(2kHz). We confirmed that this system makes it possible to form two kinds(large or uniformed grain) of poly-Si by changing its polarized directions. By using ${\mu}-crystal-Si$ as irradiated films, grain size uniformity is better than that using a-Si.

  • PDF

Measurement and Analysis for Grounding Resistance of A Large Scale Hydroelectric Power Plant (대규모 수력발전설비 접지저항 측정 및 분석)

  • Lee, Eun-Chun;Hong, Sung-Taek;Shin, Gang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.79-81
    • /
    • 2000
  • Measurement used electrical sounding(MacOHM 2115, Japan) for large scale grounding resistance of So-Yang Dam hydroelectric power plant. To applied measurement method is fall of potential method. This result propose to method of efficient administration for grounding system.

  • PDF

A case study of slope failure for large cut-slope (대절토사면내 붕괴발생에 따른 안정성검토 사례연구)

  • Lee, Yeon-Hee;Shin, Chang-Gun;Kim, Yong-Soo;Han, Jae-Hee;Choi, Jun-Il
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.697-702
    • /
    • 2006
  • A counterplan of slope failure has to investigate about various and engineering safety factors. Especially, it is important that large cut-slope must examine rational and economic solution. In this case study, cut-slope failure caused by inflow of rainwater into alternate layers. Hereafter it is suggested that large cut-slope should consider analysis the cause for a decline of safety factor and the engineering character of corestone ground mass.

  • PDF

Performance Analysis of Gas Turbine for Large-Scale IGCC Power Plant

  • Joo, Yong-Jin;Kim, Mi-Yeong;Park, Se-Ik;Seo, Dong-Kyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.415-419
    • /
    • 2016
  • As the need for clean coal technology has grown, so has the global research and development efforts into integrated gasification combined cycle (IGCC) plants. An IGCC plant couples a gas turbine to a gasification block. Various technical and economic problems exist in designing such a system. One such problem is the difficulty in realizing economies of scale because the single-train flow capacity of commercial IGCC synthetic gas turbine plants is limited; the capacity does not exceed a net power rating of 300 MW. To address this problem, this study modeled and simulated a synthetic gas turbine with the goal of evaluating the feasibility of a 500 MW or larger IGCC plant. First, a gas turbine with the best output and efficiency was chosen for use with natural gas. The turbine was modeled using GateCycle (a simulation tool), and the integrity of the model validated by comparing the result to the design value. Next, off-design modeling was carried out for a gas turbine with synthetic gas based on its on-design model, and the result was compared with the study result of the gas turbine manufacturer. The simulation confirmed that it is possible to create a large capacity IGCC plant by undertaking the remodeling of a gas turbine designed to use natural gas into one suitable for synthetic gas.

Large-scale AC/DC EMT Level System Simulations by a Real Time Digital Simulator (RTDS) in KEPRI-KEPCO

  • Park, In Kwon;Lee, Jaegul;Song, Jiyoung;Kim, Yonghak;Kim, Taekyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2017
  • Recently, the Korea Enhanced Power system Simulator (KEPS) was upgraded with new processor cards and various peripheral devices. The purpose of the upgrade is for the large-scale AC/DC simulation studies for different purposes such as FACTS, PMU applications, and SPS. The need for such study is now growing in KEPCO network. Frequently, traditional ways of performing the necessary study had been found to be less adequate for guiding the key decisions in the company. Therefore, the growing needs, as well as the revealed inadequacy of the traditional system studies, had been attributing to the momentum for the upgrade project. This paper explains the details of the upgrade project. As an example of presenting the effectiveness of the upgraded RTDS system in KEPRI-KEPCO, a large-scale AC/DC real time simulation case which includes the entire Korean network and a planned MMC-HVDC system is introduced.

Development of the Control System for Fast-Responding Frequency Regulation in Power Systems using Large-Scale Energy Storage Systems

  • Lim, Geon-Pyo;Park, Chan-Wook;Labios, Remund;Yoon, Yong-Beom
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.9-13
    • /
    • 2015
  • Energy storage systems (ESS) can be used to provide frequency regulation services in a power system to replace traditional frequency regulation power plants. Battery ESS, in particular, can provide "fast-responding frequency regulation," wherein the facility can respond immediately and accurately to the frequency regulation signal sent by the system operator. This paper presents the development and the trial run results of a frequency regulation control system that uses large-scale ESS for use in a large power system. The control system was developed initially for the 4 MW ESS demonstration facility in Jocheon Jeju Island, and was further developed for use in the 28 MW ESS facility at the Seo-Anseong substation and the 24 MW ESS facility at the Shin-Yongin substation to provide frequency regulation services within mainland Korea. The ESS facility in Seo-Anseong substation responds to a sudden drop in frequency via governor-free control, while the ESS facility in Shin-Yongin responds via automatic generator control (AGC).

Impact assessment for water pressure and turbidity occurrence by changes in water flow rate of large consumer at water distribution networks (상수도관망에서 대수용가의 유량변화에 따른 수압 및 탁도발생 영향평가)

  • Choi, Doo Yong;Kim, Ju-Hwan;Choi, Min-Ah;Kim, Do-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.277-286
    • /
    • 2014
  • Water discolouration and increased turbidity in the local water service distribution network occurred from hydraulic incidents such as drastic changes of flow and pressure at large consumer. Hydraulic incidents impose extra shear stresses on sediment layers in the network, leading to particle resuspension. Therefore, real time measuring instruments were installed for monitoring the variation of water flow, pressure, turbidity and particulates on a hydrant in front of the inlet point of large apartment complex. In this study, it is attempted to establish a more stable water supply plan and to reduce complaints from customers about water quality in a district metering area. To reduce red or black water, the water flow monitoring and control systems are desperately needed in the point of the larger consumers.