RC기둥의 내진성능에 미치는 겹침 이음상세의 영향 (Effects of Lap Splice Details on Seismic Performance of RC Columns)

  • 김철구;박홍근;김태완;엄태성
    • 한국지진공학회논문집
    • /
    • 제20권6호
    • /
    • pp.351-360
    • /
    • 2016
  • In regions of low-to-moderate seismicity, various types of lap splices are used for longitudinal reinforcement of columns at the plastic hinge zones. The seismic performance of such lap spliced columns, such as strength, deformation capacity, and energy dissipation, is affected by material strengths, longitudinal re-bar size, confinement of hoops, lap splice location, and lap splice length. In the present study, cyclic loading tests were performed for columns using three types of lap splices (bottom offset bar splice, top offset bar splice, and splice without offset bend). Lap splice length($40d_b$ and $50d_b$) was also considered as test parameters. Ties with 90-degree end hooks were provided in the lap splice length. The test results showed that strength, deformation capacity, and energy dissipation of columns significantly differed depending on the details and the length of lap splices. The bottom offset bar splice showed high ductility and energy dissipation but low strength; on the other hand, the top offset bar splice and the splice without offset bend showed high strength but moderate ductility and energy dissipation.

인장강성효과를 고려한 중공단면 교각의 모멘트-곡률 관계에 대한 연구 (A Study on the Moment-Curvature Relation of Hollow RC piers considering Tension Stiffening Effect)

  • 박영호;김세훈;최승원;오병환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.17-20
    • /
    • 2005
  • Moment-curvature relation of RC pier is influenced greatly in occurrence form of crack and difference is happened according to consideration existence and nonexistence of tension stiffening effect. However, studies considering these is very insufficient misgovernment. Also, it is sometimes unavoidable lap splice of axial reinforcement in plastic hinge region of RC piers. However, specific design standard about lap splice of axial reinforcement is unprepared real condition and study about effect that lap splice of axial reinforcement get in occurrence form of crack is insufficient misgovernment. Therefore, in this paper, experiments are performed with hollow RC piers that do lap splice of axial reinforcement by main variable. And this study present analytical method about moment-curvature relation of hollow RC pier that consider tension stiffening effect and analyze effect that lap splice of axial reinforcement gets in occurrence form of crack. Analytic method of moment-curvature relation of RC pier that present in this study shows very similar motion with experiment result and crack interval of RC pier is suffering dominate impact in the augmented reinforcement amount by lap splice and average crack interval decreases as lap splice ratio increases.

  • PDF

Response of lap splice of reinforcing bars confined by FRP wrapping: modeling approach

  • Thai, Dam Xuan;Pimanmas, Amorn
    • Structural Engineering and Mechanics
    • /
    • 제37권1호
    • /
    • pp.95-110
    • /
    • 2011
  • This paper presents a tri-uniform bond stress model for predicting the lap splice strength of reinforcing bar at the critical bond splitting failure. The proposed bond distribution model consists of three zones, namely, splitting zone, post-splitting zone and yielding zone. In each zone, the bond stress is assumed to be constant. The models for bond strength in each zone are adopted from previous studies. Combining the equilibrium, strain-slip relation and the bond strength model in each zone, the steel stress-slip model can be derived, which can be used in the nonlinear frame analysis of the column. The proposed model is applied to derive explicit equations for predicting the strength of the lap splice strengthened by fiber reinforced polymer (FRP) in both elastic and post-yield ranges. For design purpose, a procedure to calculate the required FRP thickness and the number of FRP sheets is also presented. A parametric investigation was conducted to study the relation between lap splice strength and lap splice length, number and thickness of FRP sheets and the ratio of concrete cover to bar diameter. The study shows that the lap splice strength can be enhanced by increasing one of these parameters: lap splice length, number or thickness of FRP sheets and concrete cover to bar diameter ratio. Verification of the model has been conducted using experimental data available in literature.

원전구조물의 고강도철근(550MPa) 사용에 따른 기계적이음 경제성 분석 (Cost Analysis on Mechanical Splice of High-Strength Reinforcement (550MPa) used in Nuclear Power Plant Structures)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.155-156
    • /
    • 2019
  • Because of the congestion problems, the high-strength reinforcements are expected to be used in nuclear power plant structures in the near future. According to ACI 349-13, lap splices of high-strength(550MPa) bars can be used but it is expected that lap splice length of reinforcement will be increased significantly. The increased lap splice length will be lead to increase in construction cost & period and to problems of other bar congestions. Therefore, this study will analyze the economic feasibility on mechanical splice of high-strength reinforcement used nuclear power plant structures instead of lap splice.

  • PDF

축방향철근의 겹침이음길이에 따른 원형 RC교각의 내진성능평가 (Seismic Performance Assessment of Existing Circular Sectional RC Bridge Columns according to Lap-splice Length of Longitudinal Bars)

  • 박광순;서형열;김태훈;김익현;선창호
    • 한국지진공학회논문집
    • /
    • 제18권4호
    • /
    • pp.201-212
    • /
    • 2014
  • The plastic hinge region of RC pier ensures its nonlinear behavior during strong earthquake events. It is assumed that the piers secure sufficient strength and ductility in order to prevent the collapse of the bridge during strong earthquake. However, the presence of a lap-splice of longitudinal bars in the plastic hinge region may lead to the occurrence of early bond failure in the lap-splice zone and result in significant loss of the seismic performance. The current regulations for seismic performance evaluation limit the ultimate strain and displacement ductility considering the eventual presence of lap-splice, but do not consider the lap-splice length. In this study, seismic performance test and analysis are performed according to the cross-sectional size and the lap-splice length in the case of longitudinal bars with lap-splice located in the plastic hinge region of existing RC bridge columns with circular cross-section. The seismic behavioral characteristics of the piers are also analyzed. Based upon the results, this paper presents a more reasonable seismic performance evaluation method considering the lap-splice length and the cross-sectional size of the column.

겹침이음길이 및 구속 철근에 따른 헤드철근의 구조적 성능에 관한 실험적 연구 (An Experimental Study on the Structural Performance of Headed Bars by Lap Length and Confinement Details)

  • 유호일;이용택;김승훈;채서호;반병열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.286-289
    • /
    • 2006
  • Headed bars have used to the anchoring of the tension or compression longitudinal bars and of the shear reinforcing bars. Recently, lap splices of headed bars are attempted to the joints of precast concrete members and to the connections between old and new concrete members. Previous Michael's experimental research showed that confinement details had an effect on the lap splice performances of headed bars. In this study, the lap splice performances of headed bars(D25) with lap length and confinement details are evaluated through the experimental works. Four specimens, of which variables were the lap length of headed bar and the type of confine details, were tested for the performance evaluation on lap splice. Test results show that the lap length confinement reinforcement improve the performance of lap splice.

  • PDF

축방향철근 겹침이음길이에 따른 RC원형 교각의 거동특성 - 실험적 연구 - (Seismic Behavior of Circular Sectional RC Bridge Columns with Various Lap-splice Lengths - An Experimental Study -)

  • 김익현;선창호;이승화;박광순;서형열
    • 한국지진공학회논문집
    • /
    • 제16권6호
    • /
    • pp.47-56
    • /
    • 2012
  • It is known that seismic performance of existing bridges having insufficient lateral confinements and lap-splices of longitudinal reinforcements at the base of column decreases dramatically. In this study, small-scaled model tests have been performed to confirm the seismic behaviors of RC bridge piers with various lap-splice lengths. The 8 test models have circular section with diameters of 0.65 m, 0.8 m, 1.0 m, and lap-splice lengths of B-class or C-class. The test results show that the failure modes of models are not depending on the lap-splice length itself but depend on the ratio of lap-splice length to diameter, and that the displacement ductility is also affected by this ratio.

횡보강근이 있는 40, 60 MPa 콘크리트에서 철근 압축이음의 거동과 강도 (Behavior and Capacity of Compression Lap Splice in Confined Concrete with Compressive Strength of 40 and 60 MPa)

  • 천성철;이성호;오보환
    • 콘크리트학회논문집
    • /
    • 제21권4호
    • /
    • pp.389-400
    • /
    • 2009
  • 현행 기준식에 따르면 초고강도 콘크리트에서는 철근 인장이음길이보다 압축이음길이가 더 길어지는 현상 이 발생된다. 횡보강근의 영향을 반영하면 이러한 경향은 더욱 심화된다. 실제 구조물에서 반드시 존재하는 횡보강근과 철근 지름의 영향을 40, 60 MPa 콘크리트에 대한 압축이음 실험을 통해 강도와 거동 특성을 분석하였다. 지름 22, 29 mm 에 대한 실험 결과 철근 지름의 영향은 없는 것으로 나타났다. 가는 지름의 철근에서는 이음강도의 증진이 기대될 수 있으나, 압축철근에는 주로 큰 지름의 철근이 사용되므로 압축이음에서는 철근 지름의 효과를 고려할 필요가 없을 것 으로 판단된다. 횡보강근이 있는 압축이음강도는 현행 설계기준과 비교할 때 100% 이상 크므로 횡보강근을 고려한 새 로운 설계기준식의 정립이 필요하다. 지압은 이음 단부에 배근된 횡보강근에 의해서만 강도가 향상되며, 이음구간에 배 근된 횡보강근에는 무관하다. 횡보강근량이 많을수록 부착에 의해 발현되는 강도는 거의 선형적으로 증가하며, 이음단 부에만 횡보강근을 배근해도 부착강도가 6% 향상되었다. 횡보강근이 배근된 경우 부착에 의해 발현되는 강도는 인장이 음에 비해 동등하거나 더 낮아지므로, 인장이음에 비해 압축이음의 강도 증진은 단부 지압 효과로만 설명될 수 있다.

스트럿-타이 모델을 이용한 비접촉 겹침 이음의 이음 강도 산정 (Splice Strengths of Noncontact Lap Splices Using Strut-and-Tie Model)

  • 홍성걸;천성철
    • 콘크리트학회논문집
    • /
    • 제19권2호
    • /
    • pp.199-207
    • /
    • 2007
  • 본 연구에서는 비접촉 겹침 이음에 대한 스트럿-타이 모델을 제시하여 유효 겹침 이음 길이(effective lap length, $l_p$)와 이음 강도에 영향을 주는 요인들을 분석하였다. 부착응력이 작용하여 이음 강도에 기여하는 유효 겹침 이음 길이는 전체 겹침 이음 길이보다 짧으며, 이음된 철근에 직각방향으로 배근된 횡보강량비$({\Phi})$와 (이음된 철근간 거리)/(겹침 이음 길이) 비$({\alpha})$의 영향을 받는다. 이음된 철근간 거리가 멀어질수록 동일 겹침 이음 길이에서 유효 겹침 이음 길이는 짧아지게 되어 이음 내력은 작아진다. (이음된 철근간 거리)/(겹침 이음 길이) 비$({\alpha})$가 유효 겹침 이음 길이 결정에 미치는 영향은 횡보강량비$({\Phi})$가 낮을수록 커지게 된다. 이것은 횡보강량비가 낮을수록 이음된 철근 사이에 존재하는 스트럿의 기울기가 커지므로, 이음된 철근 사이 거리가 유효 겹침 이음 길이 결정에 큰 영향을 주기 때문이다. 비접촉 겹침 이음에 대한 제안된 스트럿-타이 모델은 실제 힘의 흐름을 분석할 수 있어, 다양한 재료 및 기하학적 조건에 적합한 철근 상세 설계를 가능하게 한다. 기존 문헌의 실험에서 나타난 거동 특성과 횡보강량이 이음 강도에 미치는 영향을 제안된 스트럿-타이 모델을 이용하여 효과적으로 설명할 수 있으며, 25개 실험체에 대한 이음 강도를 변동계수 11.1% 범위 내에서 적절히 예측할 수 있었다.

GFRP 보강근의 이음성능 (Lap Splice Length of Glass Fiber Reinforced Polymer (GFRP) Reinforcing Bar)

  • 이창호;최동욱;송기모;박영환;유영찬
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.120-123
    • /
    • 2004
  • The lap splice lengths of deformed steel reinforcing bars and GFRP bars were experimentally compared using beam specimens. The purpose was to evaluate the length required of the GFRP bar to develop strength at least equivalent to the conventional steel reinforcing bar. The main test variable was the lap splice length: 10, 20, 30 $d_b$ for the deformed steel bars and 20, 30, 40 $d_b$ for the GFRP bars. Two different types of GFRP bars were tested: (1) one with spiral-type deformation and (2) plain round bars. Elastic modulus was about 1/5 of the steel bars while the tensile strength was about 690 MPa for the GFRP bars. Nominal diameter of the GFRP bars and steel bars was 12.7 and 13 mm, respectively. Normal strength concrete (28-day $f_{cu}$ = 30 MPa) was used. For the conventional steel bars (SD400 grade), strength over 400 MPa in tension was developed using the lap splice length of 20 and 30 $f_{cu}$. Only $87\%$ of the nominal yield strength was reached with the lap splice length of 10 $d_b$. For the spiral-type deformed GFRP bars with $40-d_b$ lap splice length, 440 MPa in tension was determined. The maximum tensile strength developed of the GFRP bars with smaller lap splice lengths decreased. The plain GFRP bar was not effective in developing the tensile strength even with $40-d_b$ lap splice length. Development of the cracks on beam surface was clearly visible for the beams reinforced with the GFRP bars. Mid-span deflections, however, were significantly smaller than the comparable beams with conventional steel bars indicating potential ductility problem.

  • PDF