• Title/Summary/Keyword: Lamp

Search Result 2,693, Processing Time 0.025 seconds

Effects of Optical Characteristics on the Growth of Benthic Microalga, Nitzschia sp. and Its Growth Kinetics of Phosphate for Bioremediation (생물적 환경정화를 위한 부착미세조류 Nitzschia sp.의 생장에 미치는 광학적 특성과 그에 따른 인산염 성장 동력학)

  • Oh, Seok-Jin;Kang, In-Seok;Yoon, Yang-Ho;Yang, Han-Soeb;Park, Jong-Sick
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.14 no.4
    • /
    • pp.205-212
    • /
    • 2009
  • To suggest possible to bioremediation by benthic microalgae Nitzschia sp. isolated from the Jinhae Bay, the studies investigated the effects o flight quality and quantity on the growth of Nitzschia sp. and its growth kinetics for phosphate investigated. The Nitzschia sp. was cultured under blue (450 nm), yellow (590 nm) and red wavelength (650 nm) using light emitting diode (LED) and mixed wavelengths using a fluorescent lamp. The maximum specific growth rate showed the Nitzschia sp. under blue wavelength, although photoinhibition was observed above $100\;{\mu}mol\;m^{-2}\;s^{-1}$. Mixed wavelengths were also observed by decreasing the maximum cell density from high irradiances (>$100\;{\mu}mol$ photons $m^{-2}\;s^{-1}$). The compensation photon flux density ($I_0$) calculated from the mixed wavelengths equated to a depth of 4-10 m in Jinhae Bay, and was lower in the summer season than the depth due to suspended matter (ca. 4 m). Thus, the suitable depth for maximum growth of Nitzschia sp. might be extremely limited. In the growth kinetics for phosphate, half-saturation constant ($K_s$) was similar among different wavelengths, although the maximum growth rate was varied among different wavelengths. Because the $K_s$ was high than that of the phytoplankton, Nitzschia sp. might have adapted to the high nutrient concentrations, and have effective nutrient storage in the cell quota. Thus, Nitzschia sp. may be a useful species for bioremediation of the benthic layer in polluted inner bays by means of irradiated specific wavelength as blue.

Evaluation of Cryptosporidiurn Disinfection by Ozone and Ultraviolet Irradiation Using Viability and Infectivity Assays (크립토스포리디움의 활성/감염성 판별법을 이용한 오존 및 자외선 소독능 평가)

  • Park Sang-Jung;Cho Min;Yoon Je-Yong;Jun Yong-Sung;Rim Yeon-Taek;Jin Ing-Nyol;Chung Hyen-Mi
    • Journal of Life Science
    • /
    • v.16 no.3 s.76
    • /
    • pp.534-539
    • /
    • 2006
  • In the ozone disinfection unit process of a piston type batch reactor with continuous ozone analysis using a flow injection analysis (FIA) system, the CT values for 1 log inactivation of Cryptosporidium parvum by viability assays of DAPI/PI and excystation were $1.8{\sim}2.2\;mg/L{\cdot}min$ at $25^{\circ}C$ and $9.1mg/L{\cdot}min$ at $5^{\circ}C$, respectively. At the low temperature, ozone requirement rises $4{\sim}5$ times higher in order to achieve the same level of disinfection at room temperature. In a 40 L scale pilot plant with continuous flow and constant 5 minutes retention time, disinfection effects were evaluated using excystation, DAPI/PI, and cell infection method at the same time. About 0.2 log inactivation of Cryptosporidium by DAPI/PI and excystation assay, and 1.2 log inactivation by cell infectivity assay were estimated, respectively, at the CT value of about $8mg/L{\cdot}min$. The difference between DAPI/PI and excystation assay was not significant in evaluating CT values of Cryptosporidium by ozone in both experiment of the piston and the pilot reactors. However, there was significant difference between viability assay based on the intact cell wall structure and function and infectivity assay based on the developing oocysts to sporozoites and merozoites in the pilot study. The stage of development should be more sensitive to ozone oxidation than cell wall intactness of oocysts. The difference of CT values estimated by viability assay between two studies may partly come from underestimation of the residual ozone concentration due to the manual monitoring in the pilot study, or the difference of the reactor scale (50 mL vs 40 L) and types (batch vs continuous). Adequate If value to disinfect 1 and 2 log scale of Cryptosporidium in UV irradiation process was 25 $mWs/cm^2$ and 50 $mWs/cm^2$, respectively, at $25^{\circ}C$ by DAPI/PI. At $5^{\circ}C$, 40 $mWs/cm^2$ was required for disinfecting 1 log Cryptosporidium, and 80 $mWs/cm^2$ for disinfecting 2 log Cryptosporidium. It was thought that about 60% increase of If value requirement to compensate for the $20^{\circ}C$ decrease in temperature was due to the low voltage low output lamp letting weaker UV rays occur at lower temperatures.

The Effect of VDT Work on Vision and Eye Symptoms among Workers in a TV Manufacturing Plant (텔레비젼(TV)생산업체 근로자들의 영상단말기(VDT)작업이 시력과 안증상에 미치는 영향)

  • Woo, Kuck-Hyeun;Choi, Gwang-Seo;Jung, Young-Yeon;Han, Gu-Wung;Park, Jung-Han;Lee, Jong-Hyeob
    • Journal of Preventive Medicine and Public Health
    • /
    • v.25 no.3 s.39
    • /
    • pp.247-268
    • /
    • 1992
  • This study was conducted to evaluate the effect of VDT work on eyes and vision among workers in a TV manufacturing plant. The study subjects consisted of 264 screen workers and 74 non-screen workers who were less than 40 years old male and had no history of opthalmic diseases such as corneal opacities, trauma, keratitis, etc and whose visual acuity on pre-employment health examination by Han's test chart was 1.0 or above. The screen workers were divided into two groups by actual time for screen work in a day : Group I, 60 workers, lesser than 4 hours a day and group II, 204 workers, more than 4 hours a day. From July to October 1992 a questionnaire was administered to all the study subjects for the general charateristics and subjective eye symptoms after which the opthalmologic tests such as visual acuity, spherical equivalent, lacrimal function, ocular pressure, slit lamp test, fundoscopy were conducted by one opthalmologist. The proportion of workers whose present visual acuity was decreased more than 0.15 in comparison with that on the pre-employment health examination by Han's test chart was 20.6% in Group II. 15.0% in Group I and 14.9% in non-screen workers. However, the differences in proportion were not statistically significant. The proportion of workers with decreased visual acuity was not associated with the age, working duration, use of magnifying glass and type of shift work (independent variables) in all of the three groups. However, screen workers working under poor illumination had a higher proportion of persons with decreased visual acuity than those working under adequate illumination (P<0.05) . The proportion of workers whose near vision was decreased was 27.5% in Group II, 18.3% in Group I, and 28.4% in non-screen workers and these differences in proportion were not statistically significant. Changes of near vision were not associated with 4 independent variables in all of the three groups. Six out of seven subjective eye symptoms except tearing were more common in Group I than in non-screen workers and more common in Group II than in Group I (P<0.01). Mean of the total scores for seven subjective symptoms of each worker(2 points for always, 1 point for sometimes, 0 point for never) was not significantly different between workers with decreased visual acuity and workers with no vision change. However, mean of the total scores for Group II was higher than those for the Group I and non-screen workers (P<0.01). Total eye symptom scores were significantly correlated with the grade of screen work, use of magnifying glass, and type of shift work. There was no independent variable which was correlated with the difference in visual acuity between the pre-employment health examination and the present state, the difference between far and near visions, lacrimal function, ocular pressure, and spherical equivalent. Multiple linear regression analysis for the subjective eye symptom scores revealed a positive linear relationship with actual time for screen work and shift work(P<0.01). In this study it was not observed that the VDT work decreased visual acuity but it induces subjective eye symptoms such as eye fatigue, blurred vision, ocular discomfort, etc. Maintenance of adequate illumination in the work place and control of excessive VDT work are recommended to prevent such eye symptoms.

  • PDF