• 제목/요약/키워드: Lamp

Search Result 2,703, Processing Time 0.038 seconds

The Design and Implementation of the Lamp Facility Management System based on Sensors (센서 기반의 조명 시설물 관리시스템의 설계 및 구현)

  • Kim, Dong-Hyun;Cho, Dae-Soo;Cha, Kyung-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.7
    • /
    • pp.1325-1331
    • /
    • 2007
  • To effectively manage lamp facilities on a remote place, it is required to identify a status of the places where the lamp facilities are placed. however, since there is no methods to notify the status of sensors to the central management system based on the non-networked sensor environments, it is difficult to manage the lamp facilities remotely. In this paper, we propose the lamp facility management system to acquire the various status informations of lamp facilities using more than two sensors. To get the status remotely, the system exploits a wireless network based on the ZigBee. The benefit of this system is to help the efficient dicision makings of administrators.

Development of reverse-transcription loop-mediated isothermal amplification assays for point-of-care testing of human influenza virus subtypes H1N1 and H3N2

  • Ji-Soo Kang;Mi-Ran Seo;Yeun-Jun Chung
    • Genomics & Informatics
    • /
    • v.20 no.4
    • /
    • pp.46.1-46.7
    • /
    • 2022
  • Influenza A virus (IAV) is the most widespread pathogen causing human respiratory infections. Although polymerase chain reaction (PCR)-based methods are currently the most commonly used tools for IAV detection, PCR is not ideal for point-of-care testing. In this study, we aimed to develop a more rapid and sensitive method than PCR-based tools to detect IAV using loop-mediated isothermal amplification (LAMP) technology. We designed reverse-transcriptional (RT)-LAMP primers targeting the hemagglutinin gene. RNAs from reference H1N1 and H3N2 showed specific RT-LAMP signals with the designed primers. We optimized the reaction conditions and developed universal reaction conditions for both LAMP assays. Under these conditions, the detection limit was 50 copies for both RT-LAMP assays. There was no non-specific signal to 19 non-IAV respiratory viruses, such as influenza B virus, coronaviruses, and respiratory syncytial viruses. Regarding the reaction time, a positive signal was detected within 25 min after starting the reaction. In conclusion, our RT-LAMP assay has high sensitivity and specificity for the detection of the H1 and H3 subtypes, making it suitable for point-of-care IAV testing.

Transmittance Characteristics of Fishing Lamp in the Anchovy Scoop Fishery (멸치초망어업용 집어등 광력의 수중 투과특성)

  • 박성욱;배봉성;안희춘;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.117-123
    • /
    • 2001
  • Anchovy scoop nets, a kind of lift net have been used in the coastal area of Cheju and South sea of Korea. An incandescent lamp(AC 100V, 1kW) is being used as a fishing lamp for gathering anchovy. Fishing lamp was installed at 1m ahead of the prow and 1.5m higher than the water surface. The fishing lamp let fish school rise to the water surface and attract to bag net. Accordingly, a successful anchovy catching depends on controling of fishing lamp. On the study, the distribution of spectral irradiance illumination of incandescent lamp(1kw) and the irradiance efficiency of reflection plate were analyzed and discussed to investigate the ability of fishing lamp which can attract anchovy school effectively. The results obtained are summarized as follows : 1. Around 180% of irradiance efficiency of incandescent lamp was increased by using the reflection plate. The light of lamp was radiated into water with circular shape. 2. The irradiance illumination of incandescent lamp in air was a maximum in wave length of 994nm but it was 690nm at 0.5m and 1.0m of water depth. 3. The relationship between water depth(x) and water illumination(y) of vertical light is represented as follows : y=146.03e supper(-0.37x) 4. The light of incandescent lamp(1kW) pass through much better into vertical direction than horizontal but it was estimated that the light was not able to reach depth of 20m.

  • PDF

A Review of Power Supply Technology of Electrodeless lamps (무전극 램프의 전원장치에 대한 기술 동향)

  • 한수빈;박석인;정봉만;장우진;함중걸
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.197-200
    • /
    • 2002
  • This paper reviews electrodeless lamp technology. The lamp has very long life time but very high cost compared to conventional lamps such as fluorescent lamp. For optimizing the overall system in performance and cost power supply as well as lamp is very important. First, the paper describes various electrodeless lamps and its market condition. Then, a lot of circuit technology for constructing the power supply is reviewed and circuit characteristics are discussed

  • PDF

Performance evaluation and analysis of Electrodeless Fluorescent Lamp System (무전극 형광등 시스템의 성능평가 및 분석)

  • 김현숙;이세현;신상욱;황명근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.3-8
    • /
    • 2002
  • In this paper, We measured an electric and optical characteristics for electrodeless fluorescent lamp system. We used the CCD(charged couple device) and Integrating Sphere Photometer to detect the accurate variation of data and got a characteristic of output voltage and current, luminance, luminous flux etc. And then we come to understand that the efficiency of electrodeless fluorescent lamps are similar to CFLs(compact fluorescent lamp) or HID(high intensity discharge lamp).

  • PDF

Effects of the Xe content on the electro-optical properties in the mercury-free Flat Fluorescent Lamp

  • Chung, Kyu-Yong;Lee, Sang-Mok;Jeong, Yoon-Chul;Sohn, Sang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1577-1579
    • /
    • 2007
  • Xe content is one of important factors related to characteristics of the mercury-free flat fluorescent lamp. The electro-optical properties of lamp were investigated for wide range of Xe content in Xe-Ne mixing gas. The maximum luminance of $9,289\;cd/m^2$ and efficacy of 3 lm/W was obtained with Xe 90 %.

  • PDF

Investigation of Turn-off Condition for Reliable Operation of Mercury Vapor Lamp

  • Park, Jun-Sung;Jeong, Sang-Sik;Lee, Seung-Gyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1152-1154
    • /
    • 2007
  • The distributions of mercury (Hg) in the bulb of a mercury vapor lamp are significantly affected by its turn-off conditions. Most of mercury should be attached to the electrodes before ignition by a proper turn-off condition. In the present study, the effect of the transient profiles of lamp cooling after turn-off on the distribution of Hg was investigated.

  • PDF

A Study on Series Inverter for a Fluorescent Lamp Load (형광등용직렬 인버터에 관한 연구)

  • Park, Min-Ho;Hong, Soon-Chan;Oh, Young-Chul
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.1
    • /
    • pp.7-12
    • /
    • 1983
  • When emergency lighting using a D.C. source is needed, we select the fluorescent lamp that has higher efficiency than that of an incandescene lamp. This paper deals with a series inverter for a fluorescent lamp load, which has high frequency output characteristics. First, the appropriate operating frequency is determined and second, the optimum value of circuit elements is determined in consideration of several important conditions. The results obtained by experimentations are represented.

  • PDF

A Study on Electrical and Optical Charateristics of Flat Fluorescent Lamp (평판형광램프 전기적광학적 특성 연구)

  • Kim, Soo-Yong;Lee, Oh-Keol
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1792-1794
    • /
    • 2001
  • In this paper, the basic characteristics of flat fluorescent lamp using ultraviolet generated from gas discharge and powder type electro luminescent display using a phenomenon of the light emission caused by the electrical field applied to phosphor are studied. The lamp is a simple structure with insulator layer, phosphor layer, and gas gap. Current(displacement current + discharge current) in flat fluorescent lamp using.

  • PDF

The Development of Electronic Ballast for HPS Lamp (고압 나트륨등 구동용 전자식 안정기 개발)

  • Seo, Nam-Gil;Lee, Bo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2789-2791
    • /
    • 1999
  • This paper deals with the design of the HPS electronic ballast, which consists of the ignitor for turning-up and the resonant converter for driving the lamp. Also it contains Power Factor Controller to improve the electronic efficiencies such as power factor, crest factor, low distortion, etc. To make this circuit, it is necessary to simulate it on the computer before we implement it actually. In this paper, we try to modelize the HPS lamp and ballast, and have experiments with 150 watt-HPS lamp from Kwangjunsa.

  • PDF