• Title/Summary/Keyword: Lamp

Search Result 2,703, Processing Time 0.032 seconds

Equipment Manufacturing of Lamp Heating to Fabricate Selective Emitter Silicon Solar Cell (선택적 에미터 결정질 실리콘 태양전지 제작을 위한 할로겐 램프 장치 개발)

  • Han, Kyu-Min;Choi, Sung Jin;Lee, Hi-Deok;Song, Hee-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.102-107
    • /
    • 2012
  • Halogen lamp was applied to fabricate the selective emitter crystalline silicon solar cell. In selective emitter structure, the recombination of minority carriers is reduced with heavily doped emitter under metal grid, consequently improving the conversion efficiency. Laser selective emitter process which is recently used the most generally induces the damage on the silicon surface. However the lamp has enough heat to form heavily doped emitter layer by diffusing phosphorus from PSG without surface damage. In this work, we have studied to find the design and the suitable condition for halogen lamp such as power, time, temperature and figured out the possibility to fabricate the selective emitter silicon solar cell by lamp heating. The sheet resistance with $100{\Omega}/{\Box}$ was lower to $50{\Omega}/{\Box}$ after halogen lamp treatment. Heat transfer to lightly doped emitter region was blocked by using the shadow mask.

A Study on Comparions of Ice Bag and Heat Lamp for the Relief of Perineal Discomfort. (회음부 불편감 완화를 위한 냉요법과 온요법의 비교연구)

  • 남혜경;박영숙
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.1
    • /
    • pp.27-40
    • /
    • 1991
  • Perineal discomfort from episiotomy continues to be a problem for many postpartum women. The purposes of this study were to compare the effect of ice bag and heat lamp for the relief of perineal discomfort and to identify the sustaining time of each effect. Forty women took ice bag and heat lamp with random assignment of initial therapy. Women rated the degree of perineal discomfort before and after each therapy and at half-hour, tow-hour and four-hour intervals after each therapy. A discomfort scale, 18cm graphic rating scale, was used. The results of the study were as follows ; 1. The ice bag group showed significantly lower discomfort score than the heat lamp group at the half- hour and two - hour intervals after therapy. 2. The ice bag group showed significantly lower discomfort score for 4hrs after than before therapy, but the heat lamp group did not show significantly lower discomfort score. 3. Neither the type of episiotomy nor the previous experience of heat therapy influenced on the effect of ice bag relieving the perineal discomfort. Therefore ice bag was significantly mere effective in relieving perineal discomfort than heat lamp. Subjective responeses of patients who took both therapy were very favorable toward ice bag. I suggested that nurses should provide women with adequate information about the use of ice bag and encourage to apply ice bag instead of heat lamp after episiotomy in order to promote the relief of perineal discomfort and the healing of perineal wound.

  • PDF

Novel Ignition Method for Automotive HID lamp Ballast System (자동차 헤드라이트용 고압방전등 안정기 시스템의 새로운 점등방식)

  • Kim, Yoon-Ho;Um, Tae-Wook;Lee, Jae-Hak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.4
    • /
    • pp.238-243
    • /
    • 2006
  • This paper presents novel ignition method for automotive 35W metal halide discharge lamp electronic ballast. At this study, the novel method of ignition is developed to reduce costs and size of the ballast. By use of the novel method, the voltage needed in ignition is decreased, which result in use of the lower voltage rating power devices compared with conventional method and product compactness was achieved by deleting a circuit generating negative voltage needed in ignition at an conventional circuit. In terms of luminosity, color rendering, light efficiency(lm/W) and lifespan, the metal halide lamp is superior to, but unlike halogen lamp, it have more complicated transient characteristics to reach its steady state than the conventional halogen lamp. Therefore, in this paper, the electronic ballast was designed such that the metal halide lamp could be optimized for the automotive, by applying a method of microcontroller-based digital control. The results of the proposed system is verified through various experiment results.

Simple and Rapid Detection of Vancomycin-Resistance Gene from Enterococci by Loop-Mediated Isothermal Amplification

  • Baek, Yun Hee;Hong, Seung Bok;Shin, Kyeong Seob
    • Biomedical Science Letters
    • /
    • v.26 no.3
    • /
    • pp.149-156
    • /
    • 2020
  • We developed a simple and rapid method for detecting vancomycin resistance genes, such as vanA and vanB, using loop-mediated isothermal amplification (LAMP). To identify not only vancomycin resistance genes, but also the genus Enterococcus, primers were designed for vanA, vanB, and 16S rRNA. Screening for vancomycin susceptibility in Enterococcus was performed using Etest (bioMérieux Inc). The results of the LAMP assay were compared to those of real-time RT-PCR. The optimal conditions for the LAMP assay were 65℃ for 60 min. The detection limits of the LAMP assay for vanA, and vanB were 2 × 102 copies/reaction. Compared to RT-PCR, the sensitivities and specificities of LAMP for 16S rRNA, vanA, and vanB were 100/100%, 100/100%, and 100/100%, respectively. The vanA genotype-vanB phenotype accounted for 57.5% (46/80) of the vancomycin-resistant Enterococci samples collected from 2016 to 2019. In conclusion, the LAMP assay developed in this study showed high sensitivity and specificity for vancomycin-resistant genes. Moreover, due to the simplicity and rapidity of the LAMP assay, its use can be very useful in clinical microbiology laboratories.

Detection of Acute Toxoplasmosis in Pigs Using Loop-Mediated Isothermal Amplification and Quantitative PCR

  • Wang, Yanhua;Wang, Guangxiang;Zhang, Delin;Yin, Hong;Wang, Meng
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.5
    • /
    • pp.573-577
    • /
    • 2013
  • A loop-mediated isothermal amplification (LAMP) assay allows rapid diagnosis of Toxoplasma gondii infection. In the present study, the LAMP assay was evaluated using blood from both naturally and experimentally infected pigs. The sensitivity of the LAMP assay was compared with that of Q-PCR. Both assays detected T. gondii in the blood of experimentally infected pigs, with 100% agreement. In infected blood samples, the parasite was detected as early as 2 days post-infection and reached a peak in 3-5 days. In 216 field serum samples, the detection rates of LAMP and Q-PCR assays were 6.9% and 7.8%, respectively. This result indicates that the sensitivity of the LAMP assay was slightly lower than that of the Q-PCR assay. However, the LAMP may be an attractive diagnostic method in conditions where sophisticated and expensive equipment is unavailable. This assay could be a powerful supplement to current diagnostic methods.

Database Construction of High-resolution Daily Meteorological and Climatological Data Using NCAM-LAMP: Sunshine Hour Data (NCAM-LAMP를 이용한 고해상도 일단위 기상기후 DB 구축: 일조시간 자료를 중심으로)

  • Lee, Su-Jung;Lee, Seung-Jae;Koo, Ja-seob
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.3
    • /
    • pp.135-143
    • /
    • 2020
  • Shortwave radiation and sunshine hours (SHOUR) are important variables having many applications, including crop growth. However, observational data for these variables have low horizontal resolution, rendering its application to related research and decision making on f arming practices challenging. In the present study, hourly solar radiation data were physically generated using the Land-Atmosphere Modeling Package (LAMP) at the National Center f or Agro-Meteorology, and then daily SHOUR fields were calculated through statistical downscaling. After data quality evaluation, including case studies, the SHOUR data were added to the existing publically accessible LAMP daily database. The LAMP daily dataset, newly updated with SHOUR, has been provided operationally as input data to the "Gyeonggi-do Agricultural Drought Prediction System," which predicts agricultural weather disasters and field crop growth status.

Improve the Efficiency of Hybrid Solar LED Street Lamp Controller (하이브리드 태양광 LED 가로등 컨트롤러의 효율 개선)

  • Yun, Jung-Hyun;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.131-136
    • /
    • 2015
  • We develop the 60 W class hybrid solar LED street lamp controller. The controller is providing power via an inverter in the day with the least solar cell and battery and charging the battery for the ESS, acts as a power failure, the built-in battery. Rated output of the fabricated LED street lamp is 300 W or greater battery capacity 300 Wh, discharge time 10 hr, LED street lamp efficiency showed a very high level of light efficiency by about 127 lm/W. In addition, as a result of light distribution pattern according to the distance and the light intensity measurement will be able to ensure a very high quality, show the constant brightness in the distance from the road lights 6 m is about 35~40 lux in uniformity ratio. The proposed hybrid solar LED street lamp system showed a high energy capacity of approximately 1.5 to 152.7% power generation efficiency than typical conventional solar street lamp.

Electronic Temperature and Density of Mixed Gases in Inductively Coupled Plasma Lighting System (Ne:Xe) (Inductively Coupled Plasma 광원 시스템의 Ne:Xe 혼합가스의 전자온도 및 전자밀도 특성)

  • Choi, Yong-Sung;Gu, Hal-Bon;Lee, Jin;Lim, Jong-Yeol;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.91-95
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe.

  • PDF

A Study on the CCFL Back-Light Inverter For Large size LCD TV (대화면 LCD TV를 위한 CCFL 백라이트 인버터에 관한 연구)

  • Yun, Chang-Sun;Cho, Hyun-Chang;Huh, Dong-Young;Kim, Kwang-Heon;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.502-507
    • /
    • 2006
  • According to large-sized LCD, the CCFL used in backlight is getting longer and a backlight using one lamp makes a needed brightness by arranging lamp in parallel because of the limit of brightness. In this paper, the inverter to nu the large back-light in 42inch LCD TV using 20 CCFLs was designed to produce the same output on each lamp in any input condition. Supplementing the conventional high-low method driving CCFL, by adopting high-high one, the brightness variation among each lamp sides is improved. Additionally, to improve the brightness variation, the method connecting the lamp and the capacitor in series is used. The proposed system was verified by the experiment.

A Study on Driving System and Constant Output System for a Low Pressure UV Lamp (저압 UV램프 구동시스템 및 출력안정화 시스템에 관한 연구)

  • Yi, Chin-Woo;No, Jae-Yup
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.19-23
    • /
    • 2005
  • The target of this research is a design of constant and high efficiency driving system for a low pressure UV lamp. An UV lamp system is one of wide range electrical equipments for semiconductor manufacturing and sterilization, etc... It is essential the technique of constant output for high added value device. A design target of driving system for low pressure UV lamp of conversion efficiency is 90[%], UV lamp of output stability within ${\pm}7.5[%]$, and lamp power is over 200[W]. The results meet the target of this study well, and have a benefit of domestic market occupation and enable to export. And if protection circuits were developed, it increases the stability of a electronic ballast for UV lamps.