• Title/Summary/Keyword: Laminar Pipe Flow

Search Result 61, Processing Time 0.02 seconds

Performance of a Heat pipe with Axial Grooves Formed from Corrugated Plate (접힌 板材 로 만든 그루우브 를 갖는 熱파이프 에 관한 硏究)

  • 김태현;김기현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.1
    • /
    • pp.47-55
    • /
    • 1985
  • Heat pipe with axial grooves formed from corrugated plate in the adiabatic section is studied. The axial grooves made of thin corrugated plate decrease considerably the flow resistance in the adiabatic section without increasing the thermal resistance of the heat pipe, resulting in the increase of the capillary limit, especially in the cases of heat pipes that have long adiabatic section. In the theoretical analysis, it is assumed that the liquid flow in each section laminar and fully developed and Darcy's equation can be applied to each section neglecting the end-effects associated with each transitionary region. A heat pipe which consists of axially corrugated rectangular grooves in the adiabatic section and bronze mesh in the evaporator and codenser sections was made and tested. Comparison of the experimental results, using acetone as the working fluid, with the theoretical result shows satisfactory agreement.

Heat Transfer by an Oscillating Flow in a Circular Pipe with Sinusoidal Wall Temperature Distributions (벽온도분포가 정현파인 원관에서 왕복유동에 의한 열전달 해석)

  • 이대영;박상진;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.12
    • /
    • pp.3208-3216
    • /
    • 1993
  • Heat transfer characteristics of the laminar oscillating flow in a circular pipe have been studied under the condition that the wall temperature of the pipe is distributed sinusoidally with the axial direction. The axial velocity was assumed to be uniform in radial direction and the temperature field was analyzed by means of the perturbation method. The results show that the difference between wall and section-time-averaged fluid temperature increases as the oscillating frequency increases and eventually converges to a constant value which is determined by the ratio of swept distance to the characteristic length of wall temperature distribution. Also it is shown that the dominant variable in the heat transfer process when swept distance ratio is greater than 1 is not thermal Womersley number(F) but thermal Womersley number multiplied by the square root of swept distance ratio. The variation of the time-averaged Nusselt number is obtained as a function of F. The results indicate that Nusselt number is proportional to $F_{\epsilon}^{1/2}$ when both of F and .epsilon. are much greater than 1.

Prediction of Curvature Effects on the Electromagnetic Flowmeter Characteristics with Numerical Simulation (Laminar flow) (곡관의 곡률에 따른 전자기유량계 설치효과의 수치모사에 의한 특성 예측(충류))

  • Lim, Ki Won;Choi, Sang Kyu;Chung, Myung Kyoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1453-1463
    • /
    • 1999
  • An electromagnetic flowmeter, based on a magnetic induction principle; provides an obstructionless flowmeter that essentially averages the velocity distribution over the pipe cross-sectional area. To predict the installation effects, the flowmeter installed near $90^{\circ}$ elbow is simulated by using a commercial code FLUENT(ver. 4.48) for the laminar flow field and a code developed through this study for magnetic field. The installation effects of the flowmeter are estimated by varying a number of the dependent parameters such as the radius of the elbow(Rc=1D, 1.5D, 2D, 3D), the location, Reynolds number and the direction of electrodes plane(${\varphi}$). It was found that all these factors affect the performance of the electromagnetic flowmeter significantly. The longer installation distance from the elbow is not always optimal to minimize the error, and also there exists an optimal location to install the EMF for a minimum error. Especially the flow signal with the electrodes plane direction of ${\varphi}=45^{\circ}$ is shown to yield smallest measurement error regardless of the Reynolds number and the curvature of elbow.

Study on the Effects of Flows on the Acceleration of the Grooving Corrosion in the ERW Pipe (ERW강관에서 홈부식의 가속화에 미치는 유동의 영향에 관한 연구)

  • Kim, Jae-Seong;Kim, Yong;Lee, Bo-Young
    • Journal of Welding and Joining
    • /
    • v.26 no.4
    • /
    • pp.85-91
    • /
    • 2008
  • The grooving corrosion is caused mainly by the different microstructures between the matrix and weld which is formed during the rapid heating and cooling cycle in welding. By this localized corrosion reaction of pipes, it evolves economic problems such as the early damage of industrial facilities and pipe lines of apartment, and water pollution. So lots of researches were carried out already about grooving corrosion mechanism of ERW carbon steel pipe but there is seldom study for water hammer happened by fluid phenomenon and corrosion rate by flow velocity. In this study, the analysis based on hydrodynamic and fracture mechanics was carried out. ANSYS, FLUENT and STAR-CD were used for confirmation of flow phenomenon and stress on the pipe. As the results, fatigue failure is able to be happened by water hammer and grooving corrosion rate is increased cause by turbulent. Grooving corrosion is happened on the pipe, then friction loss of fluid is occurred from corroded part. Erosion can be happened enough in corroded region of microscopic size that wear "V" form. Also pipe is able to be damaged by water hammer effects because of corroded region is general acting as a notch effects. Corrosion depth was more than half of total thickness, it can be damaged from water hammer pressure.

Operating characteristics of a heat pipe with two heat sources (두개의 열원이 부착된 히트파이프의 동작 특성)

  • Park, Jong-Heung;No, Hong-Gu;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.303-315
    • /
    • 1998
  • Numerical and experimental studies on a heat pipe with two heat sources have been performed to investigate the operating characteristics. Numerical analysis was performed based on the cylindrical two-dimensional incompressible laminar flow for the vapor space and the conjugate heat transfer for the entire heat pipe. Experimental study with a 0.45 m length copper-water heat pipe was also performed to validate the numerical modeling for the heat input range from 29 W to 47 W on each heater. As results, the temperature profiles at the outer wall for the single active heat source as well as the temperature profiles for the switching operation between two heat sources are suggested. Due to the axial conduction, it is found that the temperature drop between the evaporator and the condenser appears small when the heat source closer to the condenser is turned on. For the switching operation in the present study, the transient time is about 700s and the temperatures at the locations of both heat source are same in 130s after switching.

Echo-PIV: in vivo Flow Measurement Technique (에코 PIV: in vivo 유동 측정기법)

  • kim Hyoung-Bum;Hertzberg Jean;Shandas Robin
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.26-35
    • /
    • 2005
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) method has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window of offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow and pulsatile flow showed good agreement with both optical PIV measurements and the known analytic solution. These studies indicate that echo PIV is a promising technique for the non-invasive measurement of velocity profiles and shear stress.

  • PDF

A Numerical Analysis of Convective Heat Transfer in Air Flow Channels of a Plate Fin-tube Matrix for Heat Pipe Heat Sinks (히트파이프 히트싱크에서 평판 휜-관으로 구성된 공기유동 냉각채널의 대류 열전달 특성에 관한 수치해석)

  • Kim Sung-Hoon;Shin Hyun-Myung;Kim Chul-Ju
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.8
    • /
    • pp.862-869
    • /
    • 2005
  • A study on convective cooling characteristics has been done in the channels with heat pipes and associated Plane fins Analysis with FLUENT V5.0 lies its Purpose on the possible enhancement of heat transfer capability between an existing three in-line arrayed heatpipes and an extending four in-line arrayed heatpipes with increasing channel width. Numerical analysis is limited to the laminar flow in an isolated flow channel by employing cyclic boundary conditions for calculation purposes. Friction factors for three and four in-line arrayed heatpipes are compared with experimental results. In addition, temperature behavior at the plate fin for the three in-line arrayed heatpipes is compared with experiment. Friction factors and overall channel heat transfer coefficients (and/or Nusselt numbers) are presented as a function of Reynolds number. An increase of number of heatpipes and channel width reults in a decrease of the friction factor and doesn't not result in an increase of heat transfer performance. However. considering the 25$\%$ increase of heat load accompanies with maximum 8$^{\circ}C$ rise of average temperature of heat pipes, the four in-line array with the increase of channel width of heat pipe heat sink can be considered appropriate.

Heat Transfer by Liminar Oscillating Pipe Flow in Thermally Developing Region (원관내 층류 왕복유동에 의한 열적발달영역에서의 열전달)

  • 이대영;박상진;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.997-1008
    • /
    • 1994
  • Heat transfer by laminar oscillating flow in a circular pipe has been studied analytically. The general solution with respect to the arbitrary wall boundary condition is obtained by superposing the fluid temperatures with the sinusoidal wall temperature distributions. The fulid temperature distributions are two dimensional, but uniform flow assumption is used to simplify the velocity distribution. The heat transfer characteristics in the thermally developing regions are analyzed by applying the general solution to the two cases of thermal boundary conditions in which the wall temperature and wall heat flux distributions have a square-wave form, respectively. The results show that the length of the thermally developing region becomes larger in proportion to the oscillation frequency at slow oscillation and eventually approaches to the value comparable to the swept distance as the frequency increases. The time and cross-section averaged Nusselt number in the developing region is inversely proportional to the square root of the distance from the position where the wall boundary condition is changed suddenly. In the developed region, Nusselt number is only determined by the oscillation frequency.

Development of Echo PIV Using Ultrasound Contrast Agent (초음파 조영제를 애용한 Echo PIV 기법의 개발)

  • Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1528-1534
    • /
    • 2004
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow result of echo PIV showed good agreement with both optical PIV measurements and the known analytic solution based on a volume flow measurement.

Development of Simple Example of CFD Course in Mechanical Engineering Curriculum (I) (Laminar Pipe Flow) (기계공학교육과정에서의 전산유체동역학의 기초예제개발 (I) (수평 원관의 층류 유동))

  • Lee, Sung-Riong;Cho, Seok-Swoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.72-80
    • /
    • 2018
  • With the ever increasing advances in computers and their computing power, computational fluid dynamics(CFD) has become an essential engineering tool in the design and analysis of engineering applications. Accordingly, many universities have developed and implemented a course on CFD for undergraduate students. On the other hand, many professors have used industrial examples supplied by computational analysis software companies as CFD examples. This makes many students think of CFD as difficult and confusing. This paper presents a simple CFD example used in the department of mechanical design engineering of Kangwon National University and shows its effectiveness. Most students answered that a simple CFD example is more comprehensive than an industrial example. Therefore, it is necessary to develop simple computational analysis problems in the engineering education field.