• Title/Summary/Keyword: Laboratory set-up

Search Result 240, Processing Time 0.026 seconds

Full-scale study of conical vortices and roof corner pressures

  • Wu, F.;Sarkar, P.P.;Mehta, K.C.
    • Wind and Structures
    • /
    • v.4 no.2
    • /
    • pp.131-146
    • /
    • 2001
  • A full-scale synchronized data acquisition system was set up on the roof of the experimental building at the Texas Tech University Wind Engineering Research Field Laboratory to simultaneously collect approaching wind data, conical vortex images, and roof corner suction pressure data. One-second conditional sampling technique has been applied in the data analysis, which makes it possible to separately evaluate the influencing effects of the horizontal wind angle of attack, ${\theta}$, and the vertical wind angle of attack, ${\varphi}$. Results show a clear cause-and-effect relationship between the incident wind, conical vortices, and the induced roof-corner high-suction pressures. The horizontal wind angle of attack, ${\theta}$, is shown to be the most significant factor in influencing the overall vortex structure and the suction pressures beneath. It is further revealed that the vertical wind angle of attack, ${\varphi}$, plays a critical role in generating the instantaneous peak suction pressures near the roof corner.

A Study on the PD Measurement System for Estimating Reliabilities of Low-voltage Electrical and Electronic Components (저압용 전기전자부품의 신뢰성 평가를 위한 부분방전 측정시스템에 관한 연구)

  • Seo, Hwang-Dong;Snog, Jae-Yong;Moon, Seung-Bo;Kil, Gyung-Suk;Kang, Dong-Sik;Hwang, Don-Ha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.321-322
    • /
    • 2005
  • In this paper, we dealt with a partial discharge(PD) measurement system that has been accepted as an effective and non-destructive technique for estimating reliabilities of low-voltage electrical and electronic components. Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 37.6 mv/pC. In an application test on photo coupler, we could detect 0.1 pC level of partial discharge at the applied voltage of AC 520 $V_{peak}$.

  • PDF

Efficient Approach to Measure Crystallization Temperature in Amorphous Thin Film by Infrared Reflectivity

  • Wang, Wenxiu;Saito, Shin;Yakabe, Hidetaka;Takahashi, Migaku
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.86-89
    • /
    • 2013
  • This paper shows a new effective approach to measure crystallization temperature of soft magnetic underlayer (SUL) for next generation of heat assisted perpendicular recording media. This approach uses temperature dependent reflectivity, which shows a clear jump when samples are crystallized. To achieve this measurement, an optical system is set up using hot plate and infrared laser. Reflectivity of SUL $(Co_{70}Fe_{30})_{92}Ta_3Zr_5$ shows a clear jump at its amorphous-crystalline transition temperature. Experiment results show this effect is clear in infrared region, and is weak for visible light.

Control Strategy of Smoothing Arc for DC Arc Furnace

  • Jung, Kyungsub;Suh, Yongsug;Lee, Yongjoong;Kim, Taewon;Park, Taejun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.354-355
    • /
    • 2013
  • Fundamental features of the arc stability in DC arc furnace of 720V/100kA/72MW have been investigated. Cassie-Mayr arc model has been employed and applied for the target dc arc furnace. In order to characterize the parameters of Cassie-Mayr arc model and the behavior of unstable arc dynamics, the advanced arc simulations of magneto-hydrodynamics (MHD) has been performed. The MHD based arc simulation has been validated in the subcomponent level, for the free burning arc set up in the laboratory. From the results of MHD simulation, dc arc dynamic resistance is proposed to be an effective arc stability function reflecting the instability of dynamic arc behavior. The experimental result confirms the usefulness of proposed dynamic arc resistance as arc stability function. The proposed arc stability function can be regarded as an effective criterion for the overall power conversion system to maintain highly stable arcing operation leading to better productivity and reliability.

  • PDF

Pressure Dependence of Acoustic Properties of Liquid Ethanol by using High-pressure Brillouin Spectroscopy

  • Ko, Jae-Hyeon;Jeong, Min-Seok;Lee, Byoung Wan;Kim, Jae Hyun;Ko, Young Ho;Kim, Kwang Joo;Kim, Tae Hyun;Kojima, Seiji;Ahart, Muhtar
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.279-286
    • /
    • 2013
  • Brillouin spectroscopy has been widely used for the investigation of acoustic properties of condensed matters in the hypersonic region. A high-pressure Brillouin spectrometer was set up by combining a diamond anvil cell and a tandem multi-pass Fabry-Perot interferometer. It was successfully applied to liquid ethanol, and the pressure dependence of the sound velocity, the refractive index and other acoustic properties were derived based on the measurements. The detailed optical setup and experimental procedure are described.

Characterization of Elastic, Dielectric and Piezoelectric Properties of piezoelectric Materials

  • Cao, Wenwu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.13-22
    • /
    • 1999
  • Both the resonance and ultrasonic techniques are standard methods far characterizing the physical properties of piezoelectric materials. However, we found that each technique can only offer a few reliable measurements while the rest often have errors or impossible to implement because of the sample requirements. This paper show that one can use the combination of both techniques to achieve much better accuracy and be able to get the complete set of elastic, dielectric and piezoelectric coefficients using fewer samples. Using an ultrasonic spectroscopy we have also measure the dispersion of the ultrasonic velocity and the attenuation up to 65 MHz. Pb(Zr,Ti)O$_3$[PZT] ceramics were used as examples fur both studies.

  • PDF

Tesion Control of Unwinder/Winder using a Tension Observer (장력 관측기를 이용한 풀림롤/감김롤의 장력제어)

  • Song, Seung-Ho;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.1
    • /
    • pp.62-69
    • /
    • 2000
  • The strip tension as well as the line speed should be controlled tightly for the quality of products and productivity of the continuous strip processing line. In this paper, a new tension control algorithm with tension observer is proposed using observed tension as regulator feedback. The tension observer is based on the torque balance of a roller stand including the acceleration torque. Using this estimated tension, new tension controller can be constructed with faster dynamic response in case of line speed acceleration or deceleration. The proposed scheme needs no additional hardware because the inputs of observer, current and speed, are already being monitored by the motor drive system. Through the simulations and experiments with laboratory set up, performances fo conventional schemes and proposed one are compared. The results show the effectiveness of the proposed tension controller.

  • PDF

Characteristic Impedances in Low-Voltage Distribution Systems for Power Line Communication

  • Kim, Young-Sung;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.29-34
    • /
    • 2007
  • The input and output impedances in a low voltage distribution system is one of the most important matters for power line communication because from the viewpoint of communication, the attenuation characteristic of the high frequency signals is greatly caused by impedance mismatch during sending and receiving. The frequency range is from 1MHz to 30MHz. Therefore, this paper investigates the input and output impedances in order to understand the characteristic of high frequency signals in the low voltage distribution system between a pole transformer and an end user. For power line communication, the model of Korea's low voltage distribution system is proposed in a residential area and then the low voltage distribution system is set up in a laboratory. In the low voltage distribution system, S parameters are measured by using a network analyzer. Finally, input and output impedances are calculated using S parameters.

Improvement of the Degreasing Performance of Surface Treating Steel Sheet by the Automatic Control of Alkaline Degreasing Process (알칼리탈지공정 자동화관리에 의한 표면처리용 강판의 탈지능 향상)

  • 박노범;박대수;박정렬;유민수
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.2
    • /
    • pp.132-139
    • /
    • 1996
  • Experiments on the automatic control of NaOH concentration and on the spraying condition of NaOH solution in the alkaline degreasing process of a continuous hot-dip galvanizing line have been carried out in order to improve degreasing performance of a galvanizing sheet steel using laboratory degreasing and galvanizing simulators. The concentration of NaOH for the good degreasing has been determined to be 6.0% and more and this concentration has been able to be automatically well controlled within $\pm$0.1% by employing a solution electrical conductivity meter under a flow injection analysis condition rather than by employing a sodium ion selective electrode in the degreasing simulator. Frequent blocking of the spraying nozzles of the solution has been reduced considerably by the set-up and periodical operation of an automatic valve system in the nozzle system. By applying this automatic valve system and by automatic controlling the NaOH concentration and other ordinary variables in the degreasing process, the degreasing performance has been increased from the conventional 76% to the new 85%.

  • PDF

Charaeteristics and Applications of the Established Testosterone Immunoassays (Testosterone 면역측정법의 정립 특성과 응용)

  • Lee, Chang-Joo;Lee, Joon-Yeoung;Yoon, Yong-Dal
    • Development and Reproduction
    • /
    • v.5 no.1
    • /
    • pp.59-71
    • /
    • 2001
  • Since the first radioimmunoassay (RIA) was developed in 1970s, many conventional RIAs and non-isotopic immunoassays (NIA) had been developed in which the degree of precision, accuracy, specificity and practicability have progressively increased. Recently ultrasensitive assay method at femtogram to determine testosterone in serum, saliva and feces is required for the study of sexual dysfunctions in male and female, monitoring the psychological stress and conditions, aging process such as menopause and partial androgen deficiency in aging male, the hormonal changes of small experimental animals etc. This review discussed the recentd evelopments of steroid assay methods, based upon the testosterone assay results of authors far 20 years, and the problems associated the assay set-up, the characterizations and applications of the established procedures, and desifls of assay, reliablity criteria, and the practical aspects of assay set-up and application, based upon the data of the authors. The present study demonstrates the general problems methods to be consider in order to set up the highly sensitive assay methods and to increase the assay quality and the necessity of assay quality control program. To improve the assay quality of each laboratory and to compare the assay results in homeland, the national QC programs should be organized.

  • PDF