• Title/Summary/Keyword: Laboratory proficiency testing

Search Result 25, Processing Time 0.018 seconds

A Study of Six Sigma and Total Error Allowable in Chematology Laboratory (6 시그마와 총 오차 허용범위의 개발에 대한 연구)

  • Chang, Sang-Wu;Kim, Nam-Yong;Choi, Ho-Sung;Kim, Yong-Whan;Chu, Kyung-Bok;Jung, Hae-Jin;Park, Byong-Ok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.2
    • /
    • pp.65-70
    • /
    • 2005
  • Those specifications of the CLIA analytical tolerance limits are consistent with the performance goals in Six Sigma Quality Management. Six sigma analysis determines performance quality from bias and precision statistics. It also shows if the method meets the criteria for the six sigma performance. Performance standards calculates allowable total error from several different criteria. Six sigma means six standard deviations from the target value or mean value and about 3.4 failures per million opportunities for failure. Sigma Quality Level is an indicator of process centering and process variation total error allowable. Tolerance specification is replaced by a Total Error specification, which is a common form of a quality specification for a laboratory test. The CLIA criteria for acceptable performance in proficiency testing events are given in the form of an allowable total error, TEa. Thus there is a published list of TEa specifications for regulated analytes. In terms of TEa, Six Sigma Quality Management sets a precision goal of TEa/6 and an accuracy goal of 1.5 (TEa/6). This concept is based on the proficiency testing specification of target value +/-3s, TEa from reference intervals, biological variation, and peer group median mean surveys. We have found rules to calculate as a fraction of a reference interval and peer group median mean surveys. We studied to develop total error allowable from peer group survey results and CLIA 88 rules in US on 19 items TP, ALB, T.B, ALP, AST, ALT, CL, LD, K, Na, CRE, BUN, T.C, GLU, GGT, CA, phosphorus, UA, TG tests in chematology were follows. Sigma level versus TEa from peer group median mean CV of each item by group mean were assessed by process performance, fitting within six sigma tolerance limits were TP ($6.1{\delta}$/9.3%), ALB ($6.9{\delta}$/11.3%), T.B ($3.4{\delta}$/25.6%), ALP ($6.8{\delta}$/31.5%), AST ($4.5{\delta}$/16.8%), ALT ($1.6{\delta}$/19.3%), CL ($4.6{\delta}$/8.4%), LD ($11.5{\delta}$/20.07%), K ($2.5{\delta}$/0.39mmol/L), Na ($3.6{\delta}$/6.87mmol/L), CRE ($9.9{\delta}$/21.8%), BUN ($4.3{\delta}$/13.3%), UA ($5.9{\delta}$/11.5%), T.C ($2.2{\delta}$/10.7%), GLU ($4.8{\delta}$/10.2%), GGT ($7.5{\delta}$/27.3%), CA ($5.5{\delta}$/0.87mmol/L), IP ($8.5{\delta}$/13.17%), TG ($9.6{\delta}$/17.7%). Peer group survey median CV in Korean External Assessment greater than CLIA criteria were CL (8.45%/5%), BUN (13.3%/9%), CRE (21.8%/15%), T.B (25.6%/20%), and Na (6.87mmol/L/4mmol/L). Peer group survey median CV less than it were as TP (9.3%/10%), AST (16.8%/20%), ALT (19.3%/20%), K (0.39mmol/L/0.5mmol/L), UA (11.5%/17%), Ca (0.87mg/dL1mg/L), TG (17.7%/25%). TEa in 17 items were same one in 14 items with 82.35%. We found out the truth on increasing sigma level due to increased total error allowable, and were sure that the goal of setting total error allowable would affect the evaluation of sigma metrics in the process, if sustaining the same process.

  • PDF

Determination of halogen elements in plastics by using combustion ion chromatography (연소IC를 이용한 플라스틱 중 할로겐 물질 정량)

  • Jung, Jae Hak;Kim, Hyo Kyoung;Lee, Yang Hyoung;Lee, Lim Soo;Shin, Jong Keun;Lee, Sang Hak
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.284-295
    • /
    • 2008
  • For plastics samples, a method using combustion ion chromatography was selected as a method for rapid low-cost analysis to test whether hazardous substances are contained or not. Using combustion ion chromatography, a verification test for F, Cl and Br compounds generated a linear calibration curve with a correlation coefficient of $r^2$ = 0.999~1.000 in the calibration range from 0.5 to 4.0 mg/kg. The detection limits were found to be 0.005~0.024 mg/kg and quantitative limits were found to be 0.014~0.073 mg/kg. The recoveries of combustion ion chromatography using certified reference material (CRM) were found to be 95.5~104.9%. Based on these results, a proficiency test was conducted together with several laboratories in and out of the country, to make comparative analysis of the results from each laboratory. As a result, the data supported the use of combustion ion chromatography as an effective analysis method to deal with regulations for halogen-free electronic products and for other hazardous substances in the electronic products.

Evaluation of Quality Management of Domestic Asbestos Survey and Monitoring Service Providers (국내 석면조사기관의 품질관리 수준에 대한 평가)

  • Kwon, Jiwoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • Objectives: The aim of this study is to evaluate the quality management systems of domestic asbestos survey and monitoring service providers and the relationships with the number of licenses or designations and sales performances. Methods: Data on quality management systems were collected by assessors who were assigned by the Korea Occupational Safety and Health Agency(KOSHA) during a pilot evaluation program for designated asbestos survey and monitoring service providers in 2016 using evaluation criteria developed by KOSHA. Basic characteristics, evaluated scores, and sales performance were gathered and statistically analyzed. Results: The median and arithmetic mean of the total scores were 0.64 and 0.66. Evaluation fields that scored highly with the highest percentages were sales performance, installation and availability of equipment, compliance with the mandatory minimum number of airborne samples, laboratory independence, and results of proficiency analytical testing, in that order. Evaluation fields that received low marks with the highest percentages were the training of personnel, blank field samples, calibration of flow rates, preliminary check and visual inspection of the work area prior to the clearance test, and review and approval of final reports, in that order. Comparison of normalized scores between service providers registered for asbestos and other tasks and those designated for only asbestos showed significant differences in their evaluated scores. Sales performance did not show a positive correlation with evaluated scores. Conclusions: The quality management systems of domestic asbestos survey and monitoring service providers were poor. High scores were recorded mostly in evaluation fields related to regulatory requirements. Low scores were recorded mostly in evaluation fields related to documentation and recordkeeping. Considering the low influence of quality on sales performance, the government needs to evaluate the quality management of asbestos survey and monitoring service providers and provide the results to public in order to address their low levels of quality management.

Development and Validation of Reference Material for Proficiency Testing of Blood Heavy Metals in Environmental Biomonitoring (환경 바이오모니터링에서의 혈중 중금속 분석 숙련도 시험을 위한 표준물질 제조 및 적용성 평가)

  • Im, Hosub;Yang, Minho;Oh, Selim;Kim, Soyoung;Jung, Hojun;Cho, Yong Min;Lee, Jung Sub;Kim, Hyun Jeong;Lee, Chae Kwan;Moon, Chan-Seok;Lee, Jong-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.6
    • /
    • pp.450-464
    • /
    • 2016
  • Objectives: This study developed and validated reference materials (RMs) to analyze metal compounds in blood. Methods: We referred to KoNEHS (Korea National Environmental Health Survey) to estimate concentrations of blood metals (cadmium, Cd; lead, Pb; mercury, Hg) and applied analytical methods (inductively coupled plasma - mass spectroscopy, ICP-MS, for Cd and Pb; graphite furnace - atomic absorption spectrometry, GF-AAS, for Cd and Pb; and direct mercury analyzer, DMA, for Hg). Homogeneity and stability tests were carried out. In addition, certified values and uncertainties of RMs were calculated through internal and external experiments. All RMs were developed and assessed in various forms according to element, analytical method, and two types of concentration levels high concentration for occupational exposure and low concentration for environmental exposure. Results: All samples showed acceptable homogeneity, except for low concentration of Cd in the GF-AAS method. Short- and long-term stabilities were satisfied by ANOVA testing. In the inter-laboratory comparison, robust medians were lower than the certified values of all RMs (robust median/reference value; $1.301/1.327{\mu}g/L$ for Cd, ICP-MS, low concentration; $3.152/3.388{\mu}g/L$ for Cd, ICP-MS, high concentration; $1.219/1.301{\mu}g/L$ for Cd, GF-AAS, low concentration; $3.074/3.321{\mu}g/L$ for Cd, GF-AAS, high concentration; $14.473/14.516{\mu}g/L$ for Pb, ICP-MS, low concentration; $50.069/50.114{\mu}g/L$ for Pb, ICP-MS, high concentration; $12.881/14.147{\mu}g/L$ for Pb, GF-AAS, low concentration; $47.015/47.591{\mu}g/L$ for Pb, GF-AAS, high concentration; $4.059/4.218{\mu}g/L$ for Hg, DMA, low concentration; $11.474/11.181{\mu}g/L$ for Hg, DMA, high concentration). Conclusion: This study demonstrates procedures for developing and validating RMs for biomonitoring in the field of the environmental health.

The gene expression programming method to generate an equation to estimate fracture toughness of reinforced concrete

  • Ahmadreza Khodayari;Danial Fakhri;Adil Hussein, Mohammed;Ibrahim Albaijan;Arsalan Mahmoodzadeh;Hawkar Hashim Ibrahim;Ahmed Babeker Elhag;Shima Rashidi
    • Steel and Composite Structures
    • /
    • v.48 no.2
    • /
    • pp.163-177
    • /
    • 2023
  • Complex and intricate preparation techniques, the imperative for utmost precision and sensitivity in instrumentation, premature sample failure, and fragile specimens collectively contribute to the arduous task of measuring the fracture toughness of concrete in the laboratory. The objective of this research is to introduce and refine an equation based on the gene expression programming (GEP) method to calculate the fracture toughness of reinforced concrete, thereby minimizing the need for costly and time-consuming laboratory experiments. To accomplish this, various types of reinforced concrete, each incorporating distinct ratios of fibers and additives, were subjected to diverse loading angles relative to the initial crack (α) in order to ascertain the effective fracture toughness (Keff) of 660 samples utilizing the central straight notched Brazilian disc (CSNBD) test. Within the datasets, six pivotal input factors influencing the Keff of concrete, namely sample type (ST), diameter (D), thickness (t), length (L), force (F), and α, were taken into account. The ST and α parameters represent crucial inputs in the model presented in this study, marking the first instance that their influence has been examined via the CSNBD test. Of the 660 datasets, 460 were utilized for training purposes, while 100 each were allotted for testing and validation of the model. The GEP model was fine-tuned based on the training datasets, and its efficacy was evaluated using the separate test and validation datasets. In subsequent stages, the GEP model was optimized, yielding the most robust models. Ultimately, an equation was derived by averaging the most exemplary models, providing a means to predict the Keff parameter. This averaged equation exhibited exceptional proficiency in predicting the Keff of concrete. The significance of this work lies in the possibility of obtaining the Keff parameter without investing copious amounts of time and resources into the CSNBD test, simply by inputting the relevant parameters into the equation derived for diverse samples of reinforced concrete subject to varied loading angles.