• Title/Summary/Keyword: Laboratory pilot tests

Search Result 62, Processing Time 0.027 seconds

Evaluation of Permeability Characteristics of Yangsan Clay using Piezocone Penetration Tests and Laboratory Tests (피에조 콘 시험과 실내시험을 이용한 양산점토의 투수특성 평가)

  • Gu, Namsil;Kim, Youngmin;Park, Jaehwhan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.12
    • /
    • pp.47-54
    • /
    • 2011
  • Consolidation behavior of soft clay is generally to be affected by its compressibility and deformation characteristics. Especially, soil permeability depends on soil characteristics including its type of anisotropy. Coefficient of permeability of soft clay is mostly estimated by using laboratory(Oedometer test) and in-stiu piezocone test. The permeability characteristics of soft clay is estimated by excess pore pressure dissipation test results. In this study, the tests were performed to find out the validity of the existing theoretical formula in clay by pore pressure dissipation test and laboratory test results. After grasping of variation the coefficient of permeability ratio(${k_{h}/k_{v}}$) in different clay soils, it was found out adequate solution of in-stiu permeability ratio(${k_{h}/k_{v}}$). Piezocone tests and laboratory tests were performed at the site of pilot project of ground improvement at Yangsan-Mulgeum, Gyeongsangnam-do. Comparisons of the estimated values of ${k_{h}/k_{v}}$ using piezocone tests results and those from laboratory consolidation tests were carried out. Test results show that values of ${k_{h}/k_{v}}$ by piezocone test result(5.85) is similar of it's laboratory test(5.28).

Prediction of Hydrofracture of Rock Salt under Ground at the Waste Isolation Pilot Plant (지하 핵 폐기물 저장 암염의 파괴현상 검증 및 분석)

  • Heo, Gwang-Hee;Lee, Cheo-Keun;Heo, Yol
    • Geotechnical Engineering
    • /
    • v.11 no.3
    • /
    • pp.139-162
    • /
    • 1995
  • The possibility of the development of gas driven hydrofractures at the Waste Isolation Pilot Plant(WIPP) is investigated through analytical and numerical calculations and through laboratory experiments. First, an investigation of the chemical reactions involved shows that a large volume of gas could potentially be generated through the oxidation of iron in the waste. Simple ground water'flow calculations then show that unless regions of high permeability has been created, this gas volume will build up the pressure high enough to cause tensile damage in the horizontal planes of weakness or in the halite itself. The analytical calculations were performed using the concepts of linear elastic fracture mechanics and the numerical calculations were done using the finite element method. Also, laboratory tests were conducted to illustrate possible failure mechanisms. It is possible that after growing horizontal crack in the weaker anhydride layer, the crack could break out of this layer and propagate upward into the halite and toward the ground surface at an inclined argle of around 53$^{\circ}$ above horizontal. To prevent this latter phenomenon the anhydrite must have a fracture toughness less than 0.5590 times than that of the halite. Through the tests, three types of crack(radial vertical cracks, horizontal circular cracks and cone -shaped cracks) were observed.

  • PDF

Mix Design of Exposed Concrete Wall using Self Compacting Concrete (노출 구조물 벽체에 적용하기 위한 무다짐 콘크리트의 최적배합설계)

  • 손유신;이승훈;김규동;김한준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.555-560
    • /
    • 2002
  • The structure of Chosun-ilbo Boopyung factory was desined as exposed concrete. The self compacting concrete(non-vibrating concrete) must be applied to this case because the exposed concrete wall is very thin(200mm) and high(6m), Laboratory tests and semi mock-up test were performed for optimum mix design of the self compacting concrete. As a result, the optimum mixes were observed at the 3-component types(ope, fly-ash, slag powder) that Vp$\geq$0.175, Vw/Vp$\geq$0.95, W=170~175$kgf/m^3$ and B=500~540$kgf/m^3$ Based on this result. we make plan that the pilot productions of batcher plant, the full-scale mock up tests and site application.

  • PDF

An Application of High Strength Concrete with 800kg/c $m^2$ to High-Rise Building (초고층 빌딩 적용을 위한 설계강도 800kg/c $m^2$ 고강도 콘크리트의 개발)

  • 김규동;이승훈;김명식;손유신;김한준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.55-60
    • /
    • 2002
  • The columns and The belt wall of Tower Palace III were desined as 800kg/c $m^2$ ultra-high strength concrete. The concrete should meet or exceed the requirements of slump of 23cm, $\sigma$$_{18H}$ of 100kg/c $m^2$, $\sigma$$_{91th}$ of, 800kg/c $m^2$. The concrete mixings with 4 different domestic Silica fumes were investigated. Laboratory tests, the pilot productions of batcher plant and the full-scale mock up tests were performed. As results of site application, all test results are satisfied with the requirements of columns and belt wall.l.

  • PDF

Construction Technology of High Strength Concrete Designed 800kg/$cm^2$ for High-Rise Building (초고층 건물용 800kg/$cm^2$의 초고강도콘크리트 시공기술)

  • 김규동;이승훈;김규용;손유신;김한준
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.49.2-53
    • /
    • 2003
  • This paper reports the application of high strength concrete designed as 800kg/$cm^2$ on the columns and belt wall of Tower Palace III. The concrete should meet or exceed the requirements of slump of 23cm, ${\sigma}$18H of 100kg/$cm^2$, ${\sigma}$91th of 800kg/$cm^2$. The concrete mixings with 4 different domestic Silica fumes were investigated. Laboratory tests, the pilot productions of batcher plant and the full-scale mock up tests were performed As results of site application, all test results are satisfied with the requirements of columns and belt wall.

  • PDF

Estimating the Coefficient of Consolidation of Marine Clay Using Piezocone Penetration Tests (피에조 콘 시험을 이용한 점성토의 압밀계수 추정)

  • 박용원;구남실;이상익
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.311-320
    • /
    • 2003
  • The coefficient of consolidation of clay deposit is one of the most important properties in the design of ground improvement. The in-situ value of $c_h$ is generally estimated by pore pressure dissipation using piezocone. Many researchers have suggested theoretical formula for its estimation. This study attempts to find out the validity of the existing theoretical formula in Korea and to find out the characteristics of $c_h$ related to the mechanical properties of clay. Piezocone tests and laboratory tests were performed at the site of pilot project of ground improvement at Yangsan-Mulgeum, Gyeongnam. Comparison of the estimated values of $c_h$using piezocone tests results and those from laboratory consolidation tests are carried out. Results show that Torstensson(cylindrical cavity theory) and Teh & Houlsby solutions derive similar values of $c_h$. And $c_h$ from oedometer test shows values similar to the above two methods. The value from either of the above two methods[Torstensson(cylindrical) or Teh & Houlsby] is recommended to be used as $c_h$.

Taming of large diameter triaxial setup

  • Nair, Asha M.;Madhavi Latha, G.
    • Geomechanics and Engineering
    • /
    • v.4 no.4
    • /
    • pp.251-262
    • /
    • 2012
  • Triaxial tests are essential to estimate the shear strength properties of the soil or rock. Normally triaxial tests are carried out on samples of 38 mm diameter and 76 mm height. Granular materials, predominantly used in base/sub-base construction of pavements or in railways have size range of 60-75 mm. Determination of shear strength parameters of those materials can be made possible only through triaxial tests on large diameter samples. This paper describes a large diameter cyclic triaxial testing facility set up in the Geotechnical Engineering lab of Indian Institute of Science. This setup consists of 100 kN capacity dynamic loading frame, which facilitates testing of samples of up to 300 mm diameter and 600 mm height. The loading ram can be actuated up to a maximum frequency of 10 Hz, with maximum amplitude of 100 mm. The setup is capable of carrying out static as well as dynamic triaxial tests under isotropic, anisotropic conditions with a maximum confining pressure of 1 MPa. Working with this setup is a difficult task because of the size of the sample. In this paper, a detailed discussion on the various problems encountered during the initial testing using the equipment, the ideas and solutions adopted to solve them are presented. Pilot experiments on granular sub-base material of 53 mm down size are also presented.

Analysis of the Reinforcement Effect of Aging Reservoir Reinforced by Environmental Soil Stabilizer as Chemical Grouting Material (친환경 지반안정재를 약액주입재로 사용하여 보강한 노후 저수지의 보강효과 분석)

  • Kim, Se-Min;Seo, Se-Gwan;Cho, Dae-sung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.2
    • /
    • pp.1-11
    • /
    • 2021
  • In this study, a study related to laboratory and pilot test were performed to use an environmental soil stabilizer developed to induce a hardening reaction similar to that of Ordinary Portland Cement (OPC) by using industrial by-products of blast furnace slag and the combustion ash of a circulating fluidized bed boiler as the main material. For this, specimens were prepared using liquid A of sodium silicate and silica sol, and liquid B of an environmental soil stabilizer (or OPC), and laboratory tests were performed to analyze the strength and environmental characteristics. And pilot test was performed on the aging reservoir, field permeability test and electrical resistivity survey were performed in the field to analyze the applicability. As a result of the laboratory test, the homo-gel compressive strength of the chemical injection material using the environmental soil stabilizer as liquid B was about 2.88 to 3.23 times greater than that of OPC. In addition, the elution amount of most heavy metals was lower than that of OPC, and the survival rate in the fish, acute toxicity test was 100%. Therefore, when judged based on the results of the laboratory test, it was analyzed to be superior to OPC in terms of strength and environment. In the results of the pilot test in the aging reservoir, when the environmental soil stabilizer was reinforced with liquid B of the chemical injection material, the coefficient of permeability in the aging reservoir decreased to 1/50 level. In addition, as a result of the electrical resistivity survey, it was analyzed that the electrical resistivity inside the aging reservoir increased as time passed, the saturation zone disappeared, and the overall reinforcement.

Development of Case Management using Critical Pathway of Posterolateral Fusion for Lumbar Spinal Stenosis (사례관리를 위한 Critical Pathway 개발 : 요추협착증 환자의 융합술)

  • Park, Hae-Ok;Ro, Yoo-Ja
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.4
    • /
    • pp.727-740
    • /
    • 2000
  • It is well recognized that case management is required to survive in the rapidly changing medical environment. One of the case management is the critical pathway(CP) which is assumed to increase the quality of care and at the same time to decrease the length of stay in hospital. The purpose of the study was to develop a CP for the management of patients with postero-lateral fusion for lumbar spinal stenosis. Through review of literature and medical records of patients with spinal stenosis, a pilot CP was designed, including 8 different care components such as medication, laboratory tests, assessment etc., from one day before surgery to 6 days of postoperative care. Every item of the pilot CP was evaluated by a panel of experts to test the content validity. The items not agreed on by more than 4 out of 6 experts were deleted or modified to be integrated in the CP. To apply the modified CP to a clinical environment, the items reflecting treatment, medication and lab work were entered into an order communication system(OCS), and doctors and nurses were taught to use the CP. Finally, the development of CP for the patients with posterolateral lumbar fusion was completed after the application and variance analysis of the CP.

  • PDF

Location of pressure sensing holes in MPA flowmeter and discharge coefficients (MPA 유량계 압력감지공의 위치와 유출계수)

  • Kim, Raymond K.;Choi, Sung Kil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.160-165
    • /
    • 2004
  • MPA (Multi-Point Averaging) flow element is a new type of differential pressure (DP) flow-sensing device that was developed by Seojin Instech to improve the operating characteristics of the conventional Averaging Pilot Tube (APT) flow elements. Operating characteristics of a flowmeter in general can be defined in terms of measurement accuracy and range. Improvement of accuracy and expanding the range of flow measurement were the two main objectives of the development. To achieve these dual objectives several upstream and downstream pressure-sensing holes were placed in MPA flow element. During the course of the development it was found that certain arrangements of the pressure-sensing holes improved measurement accuracy but did not expand operating flow range of Averaging Pilot Tubes. Development tests were performed with water between Reynolds number of 50,000 and 1,000,000 in the four-inch test line at the Alden Research Laboratory, U.S.A. Purpose of this paper is to present the relationship between the various locations of the pressure-sensing holes and the performance characteristics of MPA flow element. Furthermore, the operating characteristics of the best performing MPA are compared with those of typical orifice and APT.

  • PDF