• 제목/요약/키워드: Laboratory Safety & Environment

검색결과 334건 처리시간 0.026초

A Lung Granuloma Case Possibly Associated with a Working Environment: A Case Report

  • Seehapanya, Sankom;Chaiear, Naesinee;Ratanawatkul, Pailin;Samerpitak, Kittipan;Intarawichian, Piyapharom;Wonglakorn, Lumyai
    • Safety and Health at Work
    • /
    • 제12권2호
    • /
    • pp.268-271
    • /
    • 2021
  • Lung granulomas are uncommon in Thailand. The disease typically develops from an occupational environment and is mostly caused by infection. Herein is a case report of a female patient, aged 48, working as a nurse in an Accident and Emergency Department at a hospital. Eighteen years prior to admission the patient was diagnosed with myasthenia gravis and pulmonary tuberculosis. The chest X-ray and CT scans showed a solitary pulmonary nodule in the lower left lung. The patient received an open thoracotomy with a left lobectomy. Granulomatous and nonseptate hyphae were found in the pathology diagnosis. The patient was thus diagnosed as having a lung granuloma. The galactomannan antigen test was positive. The solitary pulmonary nodule-found from the use of a Polymerase Chain Reaction (PCR) test-was an Aspergillus spp. The fungus culture was collected from air samples. The air samples were collected by the impaction technique using a microbial air sampler. Three types of Aspergillus spp. were found as well as Penicillium spp. and Monilia sitophila. The Aspergillus spp. was a match for the patient's disease. The patient was diagnosed as having a lung granuloma possibly Aspergillus nodule which was caused by airborne Aspergillus spp. from the occupational environment.

전자빔이 조사된 고분자에서 공간전하 (Space Charge in Polymers Irradiated by an E-Beam)

  • 이주홍;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.231-232
    • /
    • 2008
  • The surface made of dielectric materials can therefore become probable sites for damaging electrostatic discharges. Thanks to a specially equipped chandler, the spatial environment can be reproduced experimentally in the laboratory. In this paper, the behavior of high energy electrons injected in polymers such as PolyMethylMetaAcrylate (PMMA) and Kpton is studied. Results obtained by surface potential technique, pulse-electro acoustic device and a cell based on the split Faraday cup system are analyzed and discussed.

  • PDF

종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로 (A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals)

  • 김영애;송상훈
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제26권1호
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.

교육시설 안전 등급 인증과 학교 안전도 심사에 대한 연구 (A Study on Indoor Environment Safety Level Certification of Educational Facilities and School Safety Level Evaluation)

  • 김명관;권영국
    • 대한안전경영과학회지
    • /
    • 제25권2호
    • /
    • pp.17-28
    • /
    • 2023
  • This study aimed to verify the validity of the evaluation items and weight determination of the indoor environmental safety area, which has the most frequent accidents, among the safety certification evaluations of educational facilities by the Ministry of Education of the Republic of Korea, which has been conducted since May 2021. As a preceding study, the evaluation items of the school safety evaluation checklist being implemented in the US state of Vermont were compared, and the causes of accidents judged by teachers in the accident experiences written by 200 Korean teachers were compared with the safety certification evaluation items belonged to the Ministry of Education. In addition, research literature using the AHP analysis technique on safety risks of elementary and secondary schools in China and safety evaluation index study cases of 539 elementary school children in Indonesia were analyzed. Through these preceding studies, measures to add and adjust evaluation items were derived and the validity and importance rankings of evaluation items were calculated through AHP questionnaires to teachers and safety experts. In addition, a survey was conducted on 104 ordinary people to verify the results of expert analysis. As a result of expert AHP analysis, 'safety education and disaster response training (.396)' was the highest priority for the relative importance of the first layer, followed by 'safety measures (.387)' and 'building materials'. Safety (.216)' was found to be the highest priority. In the overall importance ranking of the 13 second-tier screening items, safety accident prevention education had the highest priority and disaster preparedness training ranked second, proving that the Ministry of Education's review weight was underestimated. In addition, slip and collision accident countermeasures, which were not in the existing Ministry of Education review items, ranked 4th, laboratory practice room safety measures ranked 6th, and sanitation, cleanliness, hazardous substance management, and cafeteria/cooking room safety measures ranked 9th, indicating a significant level of importance. Referring to the importance ranking, which is the result of this study, it is suggested that it is necessary to review the weight of each review item again.

분산 다중 센서 기반 실험실 안전 관리 시스템 (Distributed Multi-Sensor based Laboratory Safety Management System)

  • 황도연;김황룡;김은성;정대진;정회경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.585-586
    • /
    • 2019
  • 본 논문에서는 중앙 집중형이 아닌 분산 환경에서 시약장 내부 환경을 분석하여 위험상황의 식별 및 기기 제어를 수행할 수 있는 분산 제어가 가능한 분산 IoT 센서 기반 안전 실험실 관리 시스템에 대해 연구한다. 이를 위해 시약장 내부 환경을 감지하기 위해 다중센서를 적용한다. 또한 이와 같은 시약장이 다수 설치되어 있는 실험실에 대하여 관리자의 히스토리 분석 기반의 자동제어 알고리즘을 적용한 안전관리 시스템을 연구한다.

  • PDF

Research on the construction concept and general framework of Smart Water Resource

  • Tian, Yu;Li, JianGuo;Jiang, Yun-zhong
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.216-216
    • /
    • 2015
  • Frequent hydro-meteorological events caused by global climate change and human exacerbate activities, make the water resource problem more complicated. The increasing speed urbanization brings a significant impact on the city flood control and security, water supply safety, water ecological security, water environment safety and the water engineering security in China, and puts forward higher requirements to urban water integrated management, undoubtedly which become the biggest obstacle for water ecological civilization construction, thus urgent requiring an advanced methods to enhance the effectiveness of the water integrated management. The other fields of smart ideas point out a development path for water resource development. The construction demand of smart water resource is expounded in the paper, combining the philosophy of modern Internet of things with the application of cloud computing technology. The concept of smart water resource is analyzed, the connotation characteristics of smart water resource is extracted, and the general model of smart water resource is refined. Then, the frame structure of smart water resource is put forward. The connotation and the overall framework of the smart water resource represent a higher level of water resource informationization development and provide a comprehensive scientific and technological support to transform water resource management from an extensive, passive, static, branch and traditional management to a fine, active, dynamic, collaborative and modern management.

  • PDF

A Real-Time Surveillance System for Vaccine Cold Chain Based o n Internet of Things Technology

  • Shao-jun Jiang;Zhi-lai Zhang;Wen-yan Song
    • Journal of Information Processing Systems
    • /
    • 제19권3호
    • /
    • pp.394-406
    • /
    • 2023
  • In this study, a real-time surveillance system using Internet of Things technology is proposed for vaccine cold chains. This system fully visualizes vaccine transport and storage. It comprises a 4G gateway module, lowpower and low-cost wireless temperature and humidity collection module (WTHCM), cloud service software platform, and phone app. The WTHCM is installed in freezers or truck-mounted cold chain cabinets to collect the temperature and humidity information of the vaccine storage environment. It then transmits the collected data to a gateway module in the radiofrequency_physical layer (RF_PHY). The RF_PHY is an interface for calling the bottom 2.4-GHz transceiver, which can realize a more flexible communication mode. The gateway module can simultaneously receive data from multiple acquisition terminals, process the received data depending on the protocol, and transmit the collated data to the cloud server platform via 4G or Wi-Fi. The cloud server platform primarily provides data storage, chart views, short-message warnings, and other functions. The phone app is designed to help users view and print temperature and humidity data concerning the transportation and storage of vaccines anytime and anywhere. Thus, this system provides a new vaccine management model for ensuring the safety and reliability of vaccines to a greater extent.

The French Underground Research Laboratory in Bure: An Essential Tool for the Development and Preparation of the French Deep Geological Disposal Facility Cigéo

  • Pascal Claude LEVERD
    • 방사성폐기물학회지
    • /
    • 제21권4호
    • /
    • pp.489-502
    • /
    • 2023
  • This article presents the crucial role played by the French underground research laboratory (URL) in initiating the deep geological repository project Cigéo. In January 2023, Andra finalized the license application for the initial construction of Cigéo. Depending on Government's decision, the construction of Cigéo may be authorized around 2027. Cigéo is the result of a National program, launched in 1991, aiming to safely manage high-level and intermediate level long-lived radioactive wastes. This National program is based on four principles: 1) excellent science and technical knowledge, 2) safety and security as primary goals for waste management, 3) high requirements for environment protection, 4) transparent and open-public exchanges preceding the democratic decisions and orientations by the Parliament. The research and development (R&D) activities carried out in the URL supported the design and the safety demonstration of the Cigéo project. Moreover, running the URL has provided an opportunity to gain practical experience with regard to the security of underground operations, assessment of environmental impacts, and involvement of the public in the preparation of decisions. The practices implemented have helped gradually build confidence in the Cigéo project.

Application of fractals to study the corroded reinforced concrete beam

  • Fan, Y.F.;Zhou, J.;Hu, Z.Q.
    • Structural Engineering and Mechanics
    • /
    • 제20권3호
    • /
    • pp.265-277
    • /
    • 2005
  • This paper is focused on fractal analysis of the surface cracking, a new tool for safety evaluation of corroded reinforced concrete (RC) beams. Comprehensive experimental investigations, including flexural tests, coupon tests on strength evaluation of corroded concrete and rusty rebar, and pullout tests to determine bond strength between concrete and rebar were carried out on nine Corroded Reinforced Concrete Beams (CRCB) exposed to an aggressive environment for more than 10 years. In combination with test results from a previous study on CRCBs fabricated in the laboratory from accelerated methods, it is found that, for both types of beams, the surface cracking distributions are fractal in character at loading and failure stages. Fractal dimension is calculated for all specimens at different corrosion states based on fractal analysis method. Relationships between the fractal dimension and mechanical properties of corroded concrete, rebar corrosion ratio, and ductility of CRCBs are discussed in detail. It is concluded that the fractal dimension can act as a damage index and can be efficiently used to describe the corrosion state of CRCBs.

전기콘센트의 사용환경과 전류값에 따른 열적특성 및 절연저항 분석 (Analysis of Thermal Characteristics and Insulation Resistance based on Usage Environment and Current Value of Electrical Socket Outlet)

  • 김경천;김두현;김성철
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.22-30
    • /
    • 2019
  • In 2018, overload, overcurrent, insulation aging, and a contact failure caused 659 electric fires. There is almost no failure of electrical socket outlets during their manufacturing or installation period. After several months or several years, overload or overcurrent of electrical socket outlets leads to a contact failure or short circuit which causes an electric fire. Therefore, this paper analyzed for thermal characteristics based on a current value and the change in insulation resistance along with a temperature rise caused by electrical socket outlets and the state of laboratory use in workplaces. As a results, regarding the thermal characteristics based on the current value of each installation year, a temperature increase was related to a current value, an installation year, and whether the contact unit is corroded. Insulation resistance began to decrease when a temperature increased to a certain level. With a lapse of installation year, the temperature at which insulation resistance began to decrease was lowered. This paper can be applicable for the survey data about electrical socket outlet induced fire accidents and management guidelines.