• Title/Summary/Keyword: Laboratory Facility

Search Result 343, Processing Time 0.027 seconds

A Study on the Circulation System of Biosafety Level 4 Laboratory Facilities (생물안전 4등급(BL4) 실험시설의 동선계획에 관한 연구)

  • Kwon, Soonjung;Choi, Hongbin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.1
    • /
    • pp.23-32
    • /
    • 2011
  • Recently, with the advent of high risk infectious agent such as the Ebola virus, SARS, special research facilities dealing with such dangerous pathogenic are drawing attention gradually. Especially, this kind of facilities can be called BL4(Biosafety Level 4) facility. At the moment, Korean government is going to construct BL4 institute in order to handle efficiently such kind of pathogen. However, there are no proper design guidelines for BL4 facility. This paper proposes circulation system of BL4 facility on the basis of analysis of existing BL4 guidelines of Canada, and Korean BL3 facilities. The outcomes of this study are as follows. At first, functional areas of BL4 facilities have been divided into three categories according to the hazard level ; dangerous area, transitional area, and ordinary area. Secondly, circulation system of BL4 facility has been explored as a form of diagram according to the circulating subjects. These include human, laboratory animals, hazardous pathogen, equipments and cloth. This study has some limitations in that it lacks empirical evidences and concrete SOPs(Standard Operating Procedure). Despite of some weaknesses, it is expected to give some preliminary guidelines for the design of circulation system in BL4 facilities.

Biosafety and Biosecurity Programme: Its Implementation, Requirements and Continuous Development at the Nanyang Technological University in Singapore

  • Tun, Tin;Preiser, Peter Rainer
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.2
    • /
    • pp.77-84
    • /
    • 2018
  • In Singapore, biosafety and biosecurity measures are controlled by the Biological Agents and Toxins Act (BATA) and other requirements by regulatory agencies. The law prohibits and otherwise regulates the possession, use, import, transhipment, transfer, and transportation of biological agents, inactivated biological agents, and toxins that are of public health concern. The law also defines the facility requirements for high risk biological agents and toxins. The containment facility (BSL 3) is a minimum requirement to handle biological agents that falls under Schedule 1 (Risk Group 3). The Nanyang Technological University School of Biological Sciences Biosafety Level 3 Facility (NTU-SBS BSL 3) was designed specifically for research involving potential hazardous biological materials. The facility requires yearly re-certification by an approved facility certifier to meet the local requirements and international biosafety standards for a containment facility in many instances. On the other hand, most NTU researchers conduct biological projects involving biological agents with low or moderate risk groups (Risk Groups 1 and 2 or biological agents described in schedule 3 and 4 of BATA) and GMOs, which need only a BSL 2 laboratory. BSL 2 laboratories are yet to be legally certified or registered in Singapore. Institutional Biosafety Committee (IBC) identifies the requirements; defines a minimum standard in the safe control of biological risks and registers all BSL 2 laboratories in the NTU. Therefore, under the guidance of the IBC, the University Biosafety and Biosecurity Programme includes the audit and certification program as a unique and an internal exercise to bring NTU biosafety to a higher level.

Characteristics of a Corona between a Wiring Clamp(Dead End Clamp) and a Porcelain Insulator Used in a 154[kV] Power Receptacle

  • Han, Un-Ki;Kim, Jong-Min;Bang, Sun-Bae;Kim, Han-Sang;Choi, Hyeong-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.57-63
    • /
    • 2007
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154[kV] dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in 154[kV] power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method(FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.

A Heuristic Algorithm for Optimal Facility Placement in Mobile Edge Networks

  • Jiao, Jiping;Chen, Lingyu;Hong, Xuemin;Shi, Jianghong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.7
    • /
    • pp.3329-3350
    • /
    • 2017
  • Installing caching and computing facilities in mobile edge networks is a promising solution to cope with the challenging capacity and delay requirements imposed on future mobile communication systems. The problem of optimal facility placement in mobile edge networks has not been fully studied in the literature. This is a non-trivial problem because the mobile edge network has a unidirectional topology, making existing solutions inapplicable. This paper considers the problem of optimal placement of a fixed number of facilities in a mobile edge network with an arbitrary tree topology and an arbitrary demand distribution. A low-complexity sequential algorithm is proposed and proved to be convergent and optimal in some cases. The complexity of the algorithm is shown to be $O(H^2{\gamma})$, where H is the height of the tree and ${\gamma}$ is the number of facilities. Simulation results confirm that the proposed algorithm is effective in producing near-optimal solutions.

Path planning in nuclear facility decommissioning: Research status, challenges, and opportunities

  • Adibeli, Justina Onyinyechukwu;Liu, Yong-kuo;Ayodeji, Abiodun;Awodi, Ngbede Junior
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3505-3516
    • /
    • 2021
  • During nuclear facility decommissioning, workers are continuously exposed to high-level radiation. Hence, adequate path planning is critical to protect workers from unnecessary radiation exposure. This work discusses recent development in radioactive path planning and the algorithms recommended for the task. Specifically, we review the conventional methods for nuclear decommissioning path planning, analyze the techniques utilized in developing algorithms, and enumerate the decision factors that should be considered to optimize path planning algorithms. As a major contribution, we present the quantitative performance comparison of different algorithms utilized in solving path planning problems in nuclear decommissioning and highlight their merits and drawbacks. Also, we discuss techniques and critical consideration necessary for efficient application of robots and robotic path planning algorithms in nuclear facility decommissioning. Moreover, we analyze the influence of obstacles and the environmental/radioactive source dynamics on algorithms' efficiency. Finally, we recommend future research focus and highlight critical improvements required for the existing approaches towards a safer and cost-effective nuclear-decommissioning project.

Biotechnological Potential of Marine Cyanobacteria in Wastewater Treatment: Disinfection of Raw Sewage by Oscillatoria willei BDU130511

  • Uma, L.;Selvaraj, K.;Manjula, R.;Subramanian, G.;Nagarkar, Sanjay
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.4
    • /
    • pp.699-701
    • /
    • 2002
  • The current study demonstrates the ability of the marine cyanobacterium Oscillatoria willei BDU130511 to disinfect raw sewage. Within a holding time of 3 h under laboratory conditions, the organism drastically reduced in the total bacterial and coliform counts at various pH levels, in both unbuffered and buffered sewage, thereby suggesting a potential role for cyanobacteria in wastewater treatment.

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on less than three hundred bed hospitals (종합병원 진단검사의학과 검사실의 시설 현황 조사 - 300 병상 미만 병원을 중심으로)

  • Kim, Youngaee
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.15-23
    • /
    • 2019
  • Purpose: As the medical laboratories in general hospitals have made an efforts on quality management and employee health, they recognized the need of design guideline for clinical laboratory. As laboratories are prohibited to patients, their environments are becoming more congested and deteriorated as time goes by. So, this study investigates the current status of facility and equipment of laboratory medicine focusing on less than three hundred patient bed hospitals, and searches the improving matters. Methods: Questionnaires to technologist captains and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 18 answers have been analysed statistically by MS Excel program. Results: The result of this study can be summarized into followings. Clinical laboratory functions are all hematology, clinical chemistry, immunology, transfusion and urine microscopy, and except for three including microbiology for infection and bio safety level. Average man power of lab are 12.3 man including lab director and captain. Patient bed number, space area and total specimen numbers are not correlated with each other, but specimen numbers and employee number are correlated with. Work space distances are usually good, but exit distances are not adequate for escape owing to obstacles. Specimen delivery system by courier, test method by automatic analyzer, access floor for exposed plumbing and electricities are more practical. Open lab layed out in the center and lab support layed peripheral in space diagram. Lab space configuration by SD method showed that lab support area and employee support area are dissatisfied. Implications: Specialized hospital and yearly total specimen numbers are related to the space area and organization for laboratory planning and design.

PULSED NEUTRON FACILITY BASED ON AN ELECTRON LINAC

  • Kim, Guin-Yun;Son, Dong-Chul;Lee, Young-Seok;Ko, In-Soo;Cho, Moo-Hyun;Namkung, Won;Chang, Jong-Hwa
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.327-331
    • /
    • 2001
  • The Pohang Neutron Facility based on an electron linac was constructed in order to construct the infrastructure for nuclear data production in Korea. It consists of a 100-MeV electron linac, a water-cooled Ta target, and an 11-m time-of-flight path. We measured the time-of-flight path length, the neutron energy spectra for different water levels inside the moderator, and the neutron total cross sections of polyethylene and copper by the transmission method.

  • PDF

A Case Study on the Design for Jeong-eup Second Safety Evaluation Tentative Research Institute (안전성평가연구소 정읍제2안전성평가시험연구동 설계사례)

  • Jung, Jong-Lim;Oh, Kun-Hyoan;Jung, Jae-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.552-557
    • /
    • 2008
  • This paper introduces to schematic design for Korea Institute of Toxicology Second Campus at Jeong-eup and provides fundamental information and data in order to design this laboratory facility to meet the criteria of G.L.P(Good Laboratory Practice), AAALAC(Association for Assessment and Accreditation of Laboratory Animal Care) and so on. This paper especially focus on design criteria, HVAC(Heating Ventilating and Air Conditioning) equipment and systems, plumbing equipment and systems, maintenance of equipment and systems and energy saving system of this laboratory facility.

  • PDF