• Title/Summary/Keyword: Labeling efficiency

Search Result 128, Processing Time 0.021 seconds

$^{99m}Tc$ Labeling Kit Preparation and Characteristics of Anti-NCA-95 Monoclonal Antibody (항 NCA-95 단일클론항체의 $^{99m}Tc$표지 키트 제조 및 특성 연구)

  • Hong, Mee-Kyoung;Jeong, Jae-Min;Chung, June-Key;Choi, Seok-Rye;Kim, Chae-Kyun;Lee, Yong-Jin;Lee, Dong-Soo;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.541-547
    • /
    • 1996
  • The previous monoclonal antibody labeling method for bone marrow immunoscintigrapy was complicated and laborious for clinical application. Also it showed a relatively low labeling efficiency. To improve this procedure, we compared several direct labeling methods of $^{99m}Tc$. 1) The labeling efficiency in the method using gluconate as a transchelator was low (40-70%), but immunoscintigraphy using this radiotracer produced a clear image. 2) To improve labeling efficiency, ${\beta}$-mercaptoethanol was removed after reduction. The labeling efficiency was improved up to 70-80%, but the radioactivity of the blood pool was high. 3) The higest labeling efficiency (>90%) and best quality images could be obtained by using MDP as a transchelating agent. It did not require additional procedures for separation of labeled antibodies. The immunoreactivity of this antibody was 60%. Residual MDP which can be taken up by the bone could be removed by PD-10 column. The reduced antibodies were stable with a high labeling efficiency (>90%) for up to 47 days by deep freezing. We concluded that the improved procedure for $^{99m}Tc$ labeling of anti-NCA-95 monoclonal antibody using MDP as a transchelating agent will be a simple and useful method for clinical application.

  • PDF

A Study on the Effect of Perception Improvement through GMO Education: A Case of Kyungnam University Students (GMO 교육을 통한 인식개선 효과 연구: 경남대학교 학생을 대상으로)

  • Eun-Hee Seo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.2_2
    • /
    • pp.307-318
    • /
    • 2024
  • This study conducted to examine the effects of a GMO education(n=108 university students). Although the experience of encountering GMO was 84.3%, awareness was moderate or lower for 76.9%, 62% were unaware of GMO labeling, and 44.4% had no previous education on GMO. After the education, GMO positive perceptions, specifically in terms of improving work efficiency(p<0.05), negative perception(p<0.001), and GMO knowledge increased significantly(p<0.05). The need for expanding GMO labeling (p<0.05) and adjust to 0.9%(exclusion criteria) for labeling(p<0.001) increased significantly. Moreover, there was a significant increase in the need and willingness to accept a price increase for the full labeling system(p<0.01), with a significant increase in the willingness to pay up to 20%(p<0.05). The pre-contemplation stage showed a significant decrease(p<0.001). The preparation and behavior and maintenance stage showed a significant increase(p<0.001). Based on these findings, it is suggested that GMO education be implemented to provide accurate information and emphasize the necessity of consumers' right to know and choose through the implementation of the full labeling system of GM foods.

Development of bombesin peptide kit for prostate cancer diagnosis and treatment using 64Cu/177Lu.

  • Kim, Mi Hyun;Kim, Min Hwan;Kim, Kwang Il;Kim, Jung Young;Lee, Tae Sup;Kang, Joo Hyun;Lee, Kyo Chul;Lee, Yong Jin
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.59-64
    • /
    • 2017
  • It has been reported that $^{64}Cu$ was radiolabeled with bombesin (BBN) peptide binding to the gastrin releasing peptide receptor expressed in human prostate cancer cells (PC3), confirming tumor target efficacy in mouse model. In this study, we developed the kit for the diagnosis and treatment of prostate cancer that can be used clinically using bombesin peptide available of $^{64}Cu$ and $^{177}Lu$ radioisotope labeling. The NODAGA-galacto-BBN peptide containing the NODAGA chelator and galactose was dispensed into a sterilized glass vial and lyophilized to prepare a kit. The stability of the kit after long-term storage in the $4^{\circ}C$ cold chamber and the radiolabeling efficiency after $^{64}Cu$ or $^{177}Lu$ labeling were confirmed by thin layer chromatography. When labeling with $^{64}Cu$ at the initial stage of storage, labeling efficiency of NODAGA-galacto-BBN peptide kit was over 96%, labeling efficiency was over 90% when $^{177}Lu$ was labeled. At 11 months after storage, the radiolabeling efficiency of kit against $^{64}Cu$ and $^{177}Lu$ was each over 95% and 90%. The cell viability was significantly reduced in the $^{177}Lu$-NODAGA-galacto-BBN treated group compared with the control and $^{177}Lu$ alone treated group in clonogenic assay. In conclusion, the NODAGA-galacto-BBN kit prepared by the lyophilization showed high stability over time and high yield of radioisotope labeling. Also $^{177}Lu$-NODAGA-galacto-BBN confirmed high cytotoxicity to prostate cancer cells. Therefore, the NODAGA-galacto-bombesin kit is expected to be useful for the diagnosis and treatment of prostate cancer patients.

Effect of $Al^{3+}$ on Labeling Efficiency and Biodistribution of $^{99m}Tc$-MDP ($Al^{3+}$ 존재가 $^{99m}Tc$-MDP의 표지효율과 생체내 분포에 미치는 영향)

  • Chang, Young-Soo;Jeong, Jae-Min;Kim, Young-Ju;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.361-366
    • /
    • 1996
  • This study was to determine the effect of $Al^{3+}$ in $^{99m}Tc$ eluate from $^{99}Mo-^{99m}Tc$ generator on labeling efficiency and biodistribution of $^{99m}Tc$-MDP. The chromatographic analysis of $^{99m}Tc$-MDP preparations containing $Al^{3+}(0-62.5{\mu}g/ml)$ showed decreased labeling efficiency $^{99m}Tc$ pertechnetate and hydrolyzed reduced $^{99m}Tc$ fraction increased with increasing concentrations of aluminum. However, the chromatography system could not discern between hydrolyzed reduced $^{99m}Tc$ and $^{99m}Tc$ labeled colloid. $^{99m}Tc$-MDP preparations containing aluminum were relatively stable. Chromatographic analysis also confirmed that no significant differences were observed in the radiochemical purity of the filtered and the unfiltered $^{99m}Tc$-MDP preparations containing aluminum by $0.22{\mu}m$ syringe filter. In biodistribution data of ICR-mice, blood and heart uptake were increasing with increasing concentrations of aluminum, because of decreasing labeling efficiency of $^{99m}Tc$-MDP and increasing of $^{99m}Tc$ pertechnetate. However, liver and bone uptake were not significantly increased. In rat images no difference were observed at $5{\mu}g/ml\;Al^{3+}$ compare with at $0{\mu}g/ml\;Al^{3+}$, but at $10{\mu}g/ml\;Al^{3+}$ lumbar uptake was increased. As a practical conclusion, a concentration below $10{\mu}g/ml\;Al^{3+}$($10{\mu}g/ml\;Al^{3+}$ is the maximum allowed in pertechnetate eluate from $^{99}Mo-^{99m}Tc$ generator by USP.) in $^{99m}Tc$-MDP radiopharmaceutical result in low labeling efficiency. Radiochemical purity 90% of $^{99m}Tc$-MDP is the minimum allowed by USP. Therefore, when soft tissue uptake is observed in $^{99m}Tc$-MDP bone scan and labeling efficiency is above 90%, we can expect that $Al^{3+}$ in pertechnetated eluate is not the cause of soft tissue uptake.

  • PDF

Polymer Formation and Altered Biodistribution of IgG Labeled with $^{99m}Tc$ and Cyclic DTPA (항체의 Cyclic DTPA를 이용한 $^{99m}Tc$ 표지시 Polymer 형성과 체내 동태 변화)

  • Lim, Sang-Moo;Woo, Kwang-Sun;Chung, Wee-Sup;Awh, Ok-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.270-276
    • /
    • 1993
  • $Technetium-^{99m}$ labeling method using bifunctional chelating agent cyclic DTPA has been evaluated with human polyclonal nonspecific IgG. IgG was conjugated with cyclic DTPA with various molar ratio. Reduction of $^{99m}Tc$ was done with $Na_2S_2O_4$ with various molar excess. Labeling efficiency and identification of polymer was confirmed with HPLC using TSK4000 SW column. Polymer was purified with 100 cm Sepharose 6LB column. Cultured $1{\times}10^9$ Staphylococcus aureus were injected into rat thigh 24 hours later labeled IgG was injected, and in vivo distribution was observed 4 and 24 hours thereafter. Reduction of $^{99m}Tc$ was optimal with the 10000-50000 times molar excess of $Na_2S_2O_4$. Polymer formation increased with increasing mloar excess of cyclic DTPA to IgG. Three step labeling-labeling DTPA conjugated IgG after reduction of $^{99m}Tc$-made more polymer than two two step labeling-simultaneous mixing DTPA conjugated IgG, $^{99m}Tc$ and $Na_2S_2O_4$. $^{99m}Tc$ blood clearance and lower uptake in the abscess and other organs. IgG conjugated with 200 times molar excess of cyclic DTPA showed slower blood clearance with 200 times molar excess of cyclic DTPA showed slower blood clearance than that of 200 times molar excess of cyclic DTPA showed slower blood clearance than that of 20 times molar excess. In the $^{99m}Tc$ labeling of IgG with cyclic DTPA for the immunoscintigraphy, obtimal labeling condition should be chosen, and effect of the $^{99m}Tc$ labeled IgG polymer should be considered.

  • PDF

Tc-99m Labeling of Dione Bisoxime Compounds (Dione Bisoxime 계통의 화합물에 대한 테크네슘표지 원리에 관한 연구)

  • Jeong, Jae-Min;Cho, Jung-Hyuk;Oh, Seung-Joon;Lee, Myung-Chul;Chung, Soo-Wook;Chung, June-Key;Lee, Dong-Soo;Kwark, Cheol-Eun;Lee, Kyung-Han;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.110-117
    • /
    • 1995
  • Tc-99m Labeled hexamethylenepropyleneamineoxime ([$^{99m}Tc$]-HMPAO) is a famous amino-oxime compound and is widely used to construct SPECT images of cerebral blood flow. To investigate the relationship between chemical structure and radiolabeling in these kind of diamine-oxime compounds, we synthesized seven compounds by Schiff's base formation and successive reduction with sodium borohydride. They were (RR/SS )-4,8-diaza-3,6,6,9-tetramethylundecane-2,10-dione bisoxime (2), (RR/SS/meso)-4,8-diaza-3,9-dimethy-lundecane-2,10-dione bisoxime (4), (RR/SS/meso)-4,8-diaza-3,10-dimethyldodecane-2,11-dione bisoxime (5), (RR/SS/meso)-4,7-diaza-3,6,6,8-tetramethyldecane-2,9-dione bisoxime (8), (RR/SS/meso)-4,7-diaza-5,6-cyclohexyl-3,8-dimethyldecane-2,9-dione bisoxime (10), (RR/SS/meso)-3,4-bis(1-aza-2-methyl-3-oxime-1-butyl)-benzoic acid (12), and (RR/SS/ meso)-2,3-bis(1-aza-2-methyl-3-oxime-1-butyl) benzophenone (14). Chemical structures of all the synthesized compounds were identified by taking $^1H$ spectrum. Among them, 2 and 4 are propyleneamine oxime (PnAO), 6 is butyleneamine oxime (BnAO) and 8, 10, 12 and 14 are ethyleneamine oxime (EnAO). Each compound (0.5 mg) was incubated with stannous chloride (0.5 g - 8 g), carbonate-bicarbonate buffer (final concentration = 0.1 M, pH 7 - pH 10) and Tc-99m-pertechenate (1 ml). Tc-99m labeling of these compounds were checked by ITLC (acetone), ITLC (normal saline), reverse phase TLC (50 % acetonitrile) and ITLC (ethyl acetate). According to the results, EnAO's were not labeled by Tc-99m in any of above condition. About 11 % of maximum labeling efficiency was obtained with BnAO. However, 4 (PnAO) was labeled with Tc-99m to 85 % which is similar to the labeling efficiency of 2 (HMPAO). Hydrophilic impurity (9 % ) was the most significant problem with the labeling of 4, however, pertechnetate (3 % ) and colloid (3 %) were minor problem. In conclusion, we synthesized seven diamine blsoxlme compounds. Among them, four EnAO compounds were not labeled by Tc-99m. A BnAO was labeled poorly and two PnAO's were labeled well. These labeling can be explained by tertiary structure of their Tc-99m chelate.

  • PDF

A Study on Analyzing Eco-efficiency of Carbon Labeled Building Materials - Focused on Floor Finishes - (탄소성적표시 건축 재료의 환경 효율성 분석 연구 - 바닥 마감재를 중심으로 -)

  • Choi, Ji-Hye;Lee, Yoon-Sun;Kim, Jae-Jun
    • Journal of the Korean housing association
    • /
    • v.25 no.2
    • /
    • pp.71-78
    • /
    • 2014
  • In recent years, Korean government has focused on improving the environmental impact of products in order to reduce greenhouse gas emissions and to achieve their energy goals. The government has been conducting the following polices such as green procurement inducement and certification system. After carbon labeling was conducted in 2009, among a total of 1,065 items, 97 building materials have been given a certification: finishing materials items have the highest weight (56%). The increase in the certification numbers shows that there has been considerable technical efforts in the building material industry. At the awareness of carbon label and purchase of low carbon product, however, customers are aware of carbon labeling but the purchasing rate of carbon product is low. In this paper, we suggest that low carbon activities must also be considered in order to create client value by adding the concept of ecological efficiency. The objective of this study to measurer the eco-efficiency of carbon labeled building materials on the basis of environmental aspects of the product with the perspective of economy for purchasing the excellent products.

Preparation and characterization of Ga-68-deferoxamine to test the feasibility as a bifunctional chelating agent or a renal imaging radiopharmaceutical

  • Kim, Young Ju;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • Chelating agents 1,4,7-triazacyclononanetriacetic acid (NOTA), 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) and 30-amino-3,14,25-trihydroxy-3,9,14,20,25-penta-azatriacontane-2,10,13,21,24-pentaone (desferrioxamine, DFO) were labeled with $^{68}Ga$ and tested in vitro properties to check the feasibility of using DFO as a bifunctional chelating agent or renal imaging agent. The chelating agents of concentration $2{\mu}M$ were labeled with $^{68}Ga$ in 0.1 M HCl at pH 1.7-10.3 at room temperature and $80^{\circ}C$ and the optimal pH for labeling each chelating agent was found. And then, the chelating agents were labeled with $^{68}Ga$ in various concentration of chelating agents at optimal pH. The labeled chelating agents were subject to stability test in human serum and to binding studies to human red blood cell (RBC) and plasma protein. The optimal pH's of NOTA, DOTA and DFO for $^{68}Ga$-labeling were 4.4, 3.6 and 5.6, respectively. DFO ($10{\mu}M$) showed high labeling efficiency (>97%) at pH 5.6. All the labeled chelating agents showed high stability in human serum. $^{68}Ga$-DFO showed low RBC binding but significant amount was bound to plasma protein. The results demonstrated that $^{68}Ga$-DFO can be used as a bifunctional chelating agent but not as a renal imaging agent.

Effect Analysis of a Deep Learning-Based Attention Redirection Compensation Strategy System on the Data Labeling Work Productivity of Individuals with Developmental Disabilities (딥러닝 기반의 주의환기 보상전략 시스템이 발달장애인의 데이터 라벨링 작업 생산성에 미치는 효과분석)

  • Yong-Man Ha;Jong-Wook Jang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.1
    • /
    • pp.175-180
    • /
    • 2024
  • This paper investigates the effect of a deep learning-based system on data labeling task productivity by individuals with developmental disabilities. It was found that interventions, particularly those using AI, significantly improved productivity compared to self-serving task. AI interventions were notably more effective than job coach-led approaches. This research underscores the positive role of AI in enhancing task efficiency for those with developmental disabilities. This study is the first to apply AI technology to the data labeling tasks of individuals with developmental disabilities and highlighting deep learning's potential in vocational training and productivity enhancement for this group.

Effect of Carrier on Labeling and Biodistribution of Re-188-Hydroxyethylidene diphosphonate (담체가 Re-188-Hydroxyethylidene Diphosphonate의 표지와 생체내분포에 미치는 영향)

  • Chang, Young-Soo;Jeong, Jae-Min;Kim, Bo-Kwang;Cho, Jung-Hyuk;Lee, Dong-Soo;Chung, June-Key;Lee, Seung-Jin;Jin, Ren-Jie;Lee, Sang-Eun;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.344-352
    • /
    • 2000
  • Purpose: Re-188-Hydroxyethylidene diphosphonate (HEDP) is a new cost-effective agent for systemic radioisotope therapy of metastatic bone pain. We investigated the influence of carrier for labeling and biodistribution of Re-188-HEDP using HEDP kit with or without carrier ($KReO_4$). Materials and Methods: The kits (HEDP 15 mg, gentisic acid 4 mg and $SnCl_2.2H_2O_2$ 4.5 mg) with or without carrier ($KReO_4$ 0.1 mg) were labeled with Re-188 solution, made available from an in-house generator by boiling for 15 min. We compared the labeling efficiency and stability of carrier-added and carrier-free preparations of Re-188-HEDP Biodistribution and imaging studies of each preparation were performed in ICR mice ($1.85{\sim}3.7MBq/0.1ml$) and SD rats ($74.1{\sim}85.2MBq/0.5ml$). Results: The carrier-added preparation showed high labeling efficiency (95% at pH 5) and high stability in serum (88%, 3 hr). However, the carrier-free preparation showed low labeling efficiency (59% at pH 5) and low stability (43%, 3 hr). The carrier-added preparation showed high uptake in bone and low uptake in stomach and kidneys. However, the carrier-free preparation showed lower uptake in bone and higher uptake in both stomach and kidneys, which is supposed to be due to released perrhenate. The carrier-added preparation also showed better images with higher skeletal accumulation, lower uptake in other organs and lower soft tissue uptake than the carrier-free preparation. Conclusion: The results of these studies clearly demonstrate that addition of carrier perrhenate is required for high labeling efficiency, stability, bone uptake and good image quality of Re-188-HEDP.

  • PDF