• Title/Summary/Keyword: LabView.

Search Result 869, Processing Time 0.037 seconds

Implementation of Acoustic Properties Measurement System Based on LabVIEW Using PXI for Marine Sediment (PXI를 이용한 LabVIEW기반 해양퇴적물의 음향특성 측정시스템 개발)

  • Park, Ki-Ju;Kim, Dae-Choul;Lee, Gwang-Soo;Bae, Sung Ho;Kim, Gil Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.3
    • /
    • pp.216-222
    • /
    • 2015
  • A previous velocity measurement system for marine sediment had several problems such as the errors occurred when picking first arrival time and the inconvenient measurement procedure. In order to resolve these problems, we developed a new acoustic properties measurement system by using PXI (PCI eXtentions for Instrumentation) module based on LabVIEW. To verify the new system, we measured the velocity and attenuation of sediment using the new system in a parallel with the previous system under the same experimental environment. The result of measurement showed 1~2% margin of error for the velocity as well as similar attenuation values. We concluded that the new system can efficiently measure the acoustic properties of marine sediment. It also has an advantage to construct the database of acoustic data and raw signal.

Development of Gas Turbine Data Acquisition and Monitoring System based on LabVIEW (LabVIEW 기반의 가스터빈 데이터취득 및 모니터링 시스템 개발)

  • Kang Feel-Soon;Cha Dong-Jin;Chung Jae-Hwa;Seo Seok-Bin;Ahn Dal-Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.270-273
    • /
    • 2006
  • This paper presents a gas turbine data acquisition and monitoring system using a LabVIEW programming. The developed real-time monitoring system entitled a C-Tune DAS plays an important role to make an analysis of the real-time operation of the gas turbine under maintenance. The LabVIEW based software is divided into three parts according to their original functions; Data acquisition, Data analysis and display, and Data storage. The data acquisition part receives data from a PMS (Plant Management System) server and two cFPs (Compact-Field Point). To verify the validity of the developed system, it is applied to gas turbines in the combined cycle power plant in Korea.

  • PDF

Gain Scheduling in a 6-Axis Articulated Robot Based on LabVIEW (LabVIEW 기반 6축 수직다관절 로봇의 게인스케쥴링 구현 연구)

  • Kim, M.S.;Chung, W.J.;Kim, S.B.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.3
    • /
    • pp.318-324
    • /
    • 2014
  • Recent years have witnessed a growing demand for a wide variety of high-performance industrial robots. In this paper, for accurate gain tuning of a 6-axis articulated industrial robot with reduced noise, a program routine for a dynamic signal analyzer (DSA) using the frequency response method will be programmed using $LabVIEW^{(R)}$. Then, robot transfer functions can be obtained experimentally using the frequency response method with the DSA program. Data from the robot transfer functions are transformed into Bode plots, based on which an optimal gain tuning will be executed. Gain tuning can enhance the response quality of the output signal for a given input signal during real-time control of the robot. The effectiveness of our proposed technique will be verified by implementation with a (lab-manufactured) 6-axis articulated industrial robot (hereinafter called "RS2") and comparison with the zero position gain tuning, as well as other positions.

A Development of An Automatic System for Filter Quality Test using LabVIEW (LabVIEW를 이용한 필터 품질 테스트 자동화 시스템 개발)

  • Choi Wan-Sun;Kim Hyun-Keu;Jun Heung-Goo;Choi Kwan-sun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.206-208
    • /
    • 2004
  • 본 논문에서는 LabIEW를 이용하여 필터(RF 수동회로)의 주파수 특성을 테스트하고 테스트한 필터의 특성정보를 관리하는 필터 품질 자동화 시스템을 개발하였다. 개발된 시스템은 LabVIEW에 의해 GPIB 통신으로 계측장비 네트워크 어날라이저를 제어하며 제작된 필터의 S파라미터를 측정하여 명세 기준에 적합하게 제작되었는지를 판별하며 그 결과를 Mysq데이터베이스에 저장하고 관리하게 된다.

  • PDF

Motion Vector Predictor selection method for multi-view video coding (다시점 비디오 부호화를 위한 움직임벡터 예측값 선택 방법)

  • Choi, Won-Jun;Suh, Doug-Young;Kim, Kyu-Heon;Park, Gwang-Hoon
    • Journal of Broadcast Engineering
    • /
    • v.12 no.6
    • /
    • pp.565-573
    • /
    • 2007
  • In this paper, we propose a method to select motion vector predictor by considering prediction structure of a multi view content for coding efficiency of multi view coding which is being standardized in JVT. Motion vector of a different tendency is happened while carrying out temporal and view reference prediction of multi-view video coding. Also, due to the phenomena of motion vectors being searched in both temporal and view order, the motion vectors do not agree with each other resulting a decline in coding efficiency. This paper is about how the motion vector predictor are selected with information of prediction structure. By using the proposed method, a compression ratio of the proposed method in multi-view video coding is increased, and finally $0.03{\sim}0.1$ dB PSNR(Peak Signal-to-Noise Ratio) improvement was obtained compared with the case of JMVM 3.6 method.

A study on the development and performance evaluation of reflective type Heart rate measurement system for PAPS (PAPS를 위한 반사형 맥파 측정 장치의 개발 및 성능 평가)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.1
    • /
    • pp.160-166
    • /
    • 2012
  • We performed the development and performance evaluation of reflective type heart rate measurement system for PAPS. We used chip LED and chip photo TR. for low power driving. The measured PPG signal is preprocessed using high pass filter and low pass filter, and the preprocessed signal is displayed by LabVIEW. Also LabVIEW include the algorithm that extract effective signal and calculate the heart rate. We made sure that it will be able to apply to measurement equipment with high accuracy and repetition from exercising subject using this system and algorithm.

Developing the Excitation Testing Module with LabVIEW (LabVIEW를 이용한 Exciter 가진시험 모듈 개발)

  • Choi, Ki-Soo;Jung, Wei-Bong;Won, Sung-Gyu;Ahn, Se-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.37-41
    • /
    • 2007
  • Fast Fourier Transformation(FFT) is one of the most useful way to analyze response signal for the purpose of grasping the dynamic characteristics of system. Excitation is a factor or process making noise or vibration. It's typical and simple experimental method widely used for catching hold of dynamic peculiar characters and modal behaviors of system by frequency analysis. There are harmonic excitation, impact excitation, random excitation, sweep excitation, chirp excitation and so on as the ideal method in an experiment using exciter. In this thesis, excitation testing module for NI-PXI equipment is developed. The analyzing module is developed with LabVIEW tool. A user can generate each waveform for shaking a structure and see quickly and easily modal shape of system with this module. This developed module will be expected to build up more convenient and serviceable measurement system.

  • PDF

Identification of Open-Switch and Short-Switch Failure of Multilevel Inverters through DWT and ANN Approach using LabVIEW

  • Parimalasundar, E.;Vanitha, N. Suthanthira
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2277-2287
    • /
    • 2015
  • In recent times, multilevel inverters are given high priority in many large industrial drive applications. However, the reliability of multilevel inverters are mainly affected by the failure of power electronic switches. In this paper, open-switch and short-switch failure of multilevel inverters and its identification using a high performance diagnostic system is discussed. Experimental and simulation studies were carried out on five level cascaded H-Bridge multilevel inverter and its output voltage waveforms were analyzed at different switch fault cases and at different modulation index values. Salient frequency domain features of the output voltage signal were extracted using the discrete wavelet transform multi resolution signal decomposition technique. Real time application of the proposed fault diagnostic system was implemented through the LabVIEW software. Artificial neural network was trained offline using the Matlab software and the resultant network parameters were transferred to LabVIEW real time system. In the proposed system, it is possible to precisely identify the individual faulty switch (may be due to open-switch (or) short-switch failure) of multilevel inverters.