• Title/Summary/Keyword: Lab. Test

Search Result 1,797, Processing Time 0.024 seconds

Evaluating the results of the Momguard noninvasive prenatal test

  • Hu, Hae-Jin;Kwon, Young-Jun;Oh, Mijin;Kim, Jihun;Cho, Dae-Yeon;Seo, Dong-Hee
    • Journal of Genetic Medicine
    • /
    • v.12 no.2
    • /
    • pp.96-99
    • /
    • 2015
  • Purpose: To evaluate the performance of the Momguard noninvasive prenatal test by tracing the 'screen positive' results based on preliminary samples from Korean cohorts. Materials and Methods: This preliminary study is based on data collected by the LabGenomics Clinical Laboratory (Seongnam, Korea) with informed consent. Only pregnant women who underwent both the Momguard test and karyotyping were included in this study. Momguard test results were compared with those of the karyotyping analysis. Results: Among the 38 cases with 'screen positive' results by Momguard, 30 cases also had karyotyping results available. In three trisomy (T) 18 and three T13 cases, the Momguard results were concordant with the karyotyping results. For the T21 cases, except for one case belonging to the mid-risk zone, Momguard results from 23 out of 24 cases matched the karyotyping results. Conclusion: Momguard is a highly reliable screening tool for detecting T13, T18, and T21 cases in independent Korean cohort samples.

A Study of Economical Sample Size for Reliability Test of One-Shot Device with Bayesian Techniques (베이지안 기법을 적용한 일회성 장비의 경제적 시험 수량 연구)

  • Lee, Youn Ho;Lee, Kye Shin;Lee, Hak Jae;Kim, Sang Moon;Moon, Ki Sung
    • Journal of Applied Reliability
    • /
    • v.14 no.3
    • /
    • pp.162-168
    • /
    • 2014
  • This paper discusses the application of Bayesian techniques with test data on similar products for performing the Economical Reliability Test of new one-shot device. Using the test data on similar products, reliability test required lower sample size currently being spent in order to demonstrate a target reliability with a specified confidence level. Furthermore, lower sample size reduces cost, time and various resources on reliability test. In this paper, we use similarity as calculating weight of similar products and analyze similarity between new and similar product for comparison of the essential function.

Test Plan for Anti-Jamming System Performance Evaluation

  • Park, Ji-Hee;Kwon, Seung Bok;Shin, Dong-Ho
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.4 no.1
    • /
    • pp.17-23
    • /
    • 2015
  • With the increase in the risk of GPS jamming, the development and application of anti-jamming GPS techniques have been actively performed. As the objective performance verification of developed techniques is important, equipment development for verification and discussion on anti-jamming performance test method and procedure have also been conducted. However, most tests are related to the specification of equipment and therefore detailed procedure of the performance verification of an anti-jamming system needs to be developed. In this study, requirements for anti-jamming performance verification were described, and test configurations and performance evaluation items depending on three kinds of test methods (lab test, basic outdoor test, and chamber test) were suggested for anti-jamming performance verification.

A Study on Field-to-lab Test Method for the Safe Transport and Optimum Packaging Design of the Parcel Delivery in Korea (국내 택배화물의 안전운송 및 적정포장을 위한 Field-to-Lab 시험방법 연구)

  • Oh, Jae Young;Suh, Sang Uk;Lim, Mijin
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.2
    • /
    • pp.127-132
    • /
    • 2022
  • The growth of e-commerce market requires more delivery packagings, which protect goods from the damage factors on the delivery. In this study, we have analyzed the distribution environment data (vibration and impact) measured in previous study and compared with global standards (ISTA, ASTM), so that we developed the testing method for Field-to-Lab simulation suitable to the domestic delivery. In order to verify the efficacy of this method, we took the Field-to-Lab tests for 3 packaged products (detergents set, glass tableware set, small furniture), which has been frequent breakages or damages on the actual delivery by e-commerce order, so that we could find out the test results were similar to those of the actual delivery occasions. In addition, we could perform redesign and improvement of the parcel delivery packagings for safe transportation by taking this Field-to-Lab test repeatedly. This test methods was finally proposed to be Korean industrial standard (KS), and is expected to be useful as a designing tool for the packaging optimization between protecting goods and reducing packaging waste.

Studies on the development of removal technique of residual pesticides in ginseng concentration (인삼농축액의 잔류농약 제거기술 개발에 관한 연구)

  • Sin, Yeong-Min;Son, Yeong-Uk;Lee, Seon-Hwa;Jeong, Ji-Yoon;Won, Young-Jun;Lee, Chang-Hee;Kim, Woo-Seong;Chae, Kab-Ryong;Hong, Moo-Ki
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.1
    • /
    • pp.41-50
    • /
    • 2005
  • For the removal of residual pesticides in ginseng extracts, we estabilished the removal process using pilot plant system, the characteristic components of ginseng maintains only. According to the agricultural chemical removal process, we monitored residual pesticides of 155 species, compraing the characteristic components of ginseng. The process of 4 types of agricultural chemical removal process compared to the control test was appeared that the residual pesticides were eliminated. As results above, the most efficient method of the possibility of raising the removal ratio of the agricultural chemical construction process was dried process of hexane after dipping and also remaining quality of the hexane appeared lowly. Besides, the removal process had an effected on the ginsenocide os ginseng, only the residual pesticides will be able to remove.

Calculation of Sample Size for Guided Missile Considering Test Method and Reliability Growth (유도무기 시험평가 방법과 신뢰성 성장을 고려한 시험 수량 산출)

  • Lee, Youn-ho;Kim, Jae-hwang;Lee, Kye-shin;Lee, Jong-sin;Lee, Myoung-jin;Kim, Doo-hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.844-852
    • /
    • 2017
  • Since guided weapon is high-cost and one-shot device which is non-reusable, it requires a lot of resources to prove required accuracy as a part of reliability demonstration. Once a test for proving accuracy rate of guided missile fails, it causes an additional cost and delay of schedule. This study introduces an equation for proper sample size and plan for guided-missile accuracy rate test in order to minimize the risk of test failure. Proper sample size for the test is derived by considering the reliability growth. Furthermore, each task for accuracy rate test is defined according to the development step. Therefore, this study can contribute to reduce sample size for accuracy rate test in order to meet the reliability requirement and assure transparency in the test process.

KR-25018: A Novel, Orally Active Analgesic with Non-Narcotic Properties

  • Lee, Buyean;Kim, Jae-Hong;Park, No-Sang;Kong, Jae-Yang
    • Archives of Pharmacal Research
    • /
    • v.17 no.5
    • /
    • pp.304-308
    • /
    • 1994
  • Among the new series of phenylacetamides, one of capsaicin derivatives, KR-25018 was found to have a very potent analgesic activity. Thus, the phamacological properties of KR-25018 were compared with those of morphine, capsaicin, and nonsteroidal antiinflammatory drugs (NSAIDs). The analgesic activities were evaluated in several animal models, using different stimuli, such as phenylbenzoquinone(PBQ)-induced weithing test, tail-filck test in mice and adjuvant arthritic flexion test in rat. The relationship of phamacological properties of KR-25018 to that of centrally acting opioids was assessed by the blocking test using naloxone. The analgesic potency of the KR-25018 $(MPED_{50}=0.89{\;}p.o.{\;}in{\;}PBQ-induced{\;}weithing{\;}test, {\;}MPED_{50}$=0.61$ s.c. in tail-flick test in mice0, with different action mechanism from morphine and NSAIDs, was comparable to that of morphine.

  • PDF

A Method of Reliability Growth Management Test Design for Continuous System (연속형 시스템의 신뢰성 성장 관리 시험 설계 방안)

  • Seo, Yang Woo;Yoon, Jung Hwan;Lee, Seung Sang;Um, Chun Sup
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.2
    • /
    • pp.87-96
    • /
    • 2020
  • In this paper we proposed the test design method of reliability growth management. First, we presented the process for establishing the reliability growth management test design considering the number of failures and the termination test time. Reliability growth analysis of continuous system was performed in accordance with the test design process presented. In case the reliability test result is not met with the reliability target value after more than three failures occurred, the required test times were analyzed that 1,725 hrs for one corrective action, 1,950 hrs for two corrective actions. If the number of failures is less than three, design a reliability demonstration test according to confidence level 80% and 90% was performed using RGA 11 Software. As a result, it is possible to establish the reliability growth management test design with sufficient use of available resources. The results of this study can be used when establishing a test design for assessment of reliability growth management of all continuous systems.