• Title/Summary/Keyword: Lab Scale 실험

Search Result 301, Processing Time 0.027 seconds

Study on combustion instabilities in gas turbine combustors (가스터빈 연소기에서의 연소 불안정 측정에 관한 연구)

  • Kim, Dae-Sik;Lee, Jong-Guen;Santavicca, Domenic
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.430-432
    • /
    • 2011
  • An experimental study of the flame response in a turbulent premixed combustor has been conducted in order to investigate mechanisms for combustion instabilities in lean premixed gas turbine combustor. A lab-scale combustor and mixing section system were fabricated to measure the flame transfer function. Measurements are made of the velocity fluctuation in the nozzle using hot wire anemometry and of the heat release fluctuation in the combustor using chemiluminescence emission. The results are analyzed to determine the phase and gain of the flame transfer function as a function of the modulation frequency and operating conditions.

  • PDF

Reclamation of High Purity Organic Solvents from Waste Photoresist Stripper (포토레지스트 스트리퍼 폐액으로부터 고순도 유기용제 회수)

  • Kim, Dae-Jin;Oh, Han-Sang;Kim, Jae-Kyeong;Park, Myeong-Jun;Lee, Moon-Yong;Koo, Kee-Kahb
    • Clean Technology
    • /
    • v.13 no.4
    • /
    • pp.257-265
    • /
    • 2007
  • As a basic study for the development of pilot-scale distillation process of waste photoresist strippers from semiconductor industry, lab-scale experiments for the recovery of NMP (N-methy1-pyrrolidione) and BDG (Butyldiglycol) from waste photoresist strippers have been made using a spinning band vacuum distillation column. Purities of NMP and BDG obtained from the present experiments were higher than 99.5%. Furthermore, water content was less than 1000 ppm, color grade(APHA) less than 50, most metal contents except sodium less than 1 ppb. Those results indicate that NMP and BDG reclamed by distillation satisfy the their specifications required for the formulation of new photoresist strippers. Recovery rate of NMP and BDG was 96 and 53%, respectively, for type A, and 93 and 57%, respectively, for type B waste PR stripper solution.

  • PDF

Analysis of Fluid Flows in a High Rate Spiral Clarifier and the Evaluation of Field Applicability for Improvement of Water Quality (고속 선회류 침전 장치의 유동 해석 및 수질 개선을 위한 현장 적용 가능성 평가)

  • Kim, Jin Han;Jun, Se Jin
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2014
  • The purpose of this study is to evaluate the High Rate Spiral Clarifier(HRSC) availability for the improvement of polluted retention pond water quality. A lab scale and a pilot scale test was performed for this. The fluid flow patterns in a HRSC were studied using Fluent which is one of the computational fluid dynamic(CFD) programs, with inlet velocity and inlet diameter, length of body($L_B$) and length of lower cone(Lc), angle and gap between the inverted sloping cone, the lower exit hole installed or not installed. A pilot scale experimental apparatus was made on the basis of the results from the fluid flow analysis and lab scale test, then a field test was executed for the retention pond. In the study of inside fluid flow for the experimental apparatus, we found out that the inlet velocity had a greater effect on forming spiral flow than inlet flow rate and inlet diameter. There was no observable effect on forming spiral flow LB in the range of 1.2 to $1.6D_B$(body diameter) and Lc in the range of 0.35 to $0.5L_B$, but decreased the spiral flow with a high ratio of $L_B/D_B$ 2.0, $Lc/L_B$ 0.75. As increased the angle of the inverted sloping cone, velocity gradually dropped and evenly distributed in the inverted sloping cone. The better condition was a 10cm distance of the inverted sloping cone compared to 20cm to prevent turbulent flow. The condition that excludes the lower exit hole was better to prevent channeling and to distribute effluent flow rate evenly. From the pilot scale field test it was confirmed that particulate matters were effectively removed, therefore, this apparatus could be used for one of the plans to improve water quality for a large water body such as retention ponds.

Characteristics of Coal Methanation in a Hydrogasifier (수소가스화기에서 석탄의 메탄화 반응 특성)

  • Lee, S.H.;Yoon, S.J.;Choi, Y.C.;Kim, J.H.;Lee, J.G .
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.631-635
    • /
    • 2006
  • To investigate the characteristics of substitute natural gas (SNG) production from direct coal methanation, the continuous lab-scale entrained flow hydrogasifier (I.D. : 0.025 m, Height : 1.0 m) was used in this experiment. The hydrogasification system consisted of high pressure gas handling system, high pressure coal feeder, entrained flow hydrogasifier, and unreacted char separator. The experiment was performed at the various conditions of reaction temperature ($600{\sim}800^{\circ}C$), $H_2$/coal ratio (0.2~0.4), and coal feed rate (0.8~2.5 g/min). Although it was shown that carbon conversion was different trends with coals from the methanation results for 6 sample coals, the carbon conversion increased with increasing reaction temperature. And it increased with increasing H2/coal ratio, whereas the concentration of CH4 decreased. Also. the carbon conversion increased with the carbon content of coal sample and had a maximum value at volatile matter content of 35 wt%.

Experimental Study on Application of an Anomaly Detection Algorithm in Electric Current Datasets Generated from Marine Air Compressor with Time-series Features (시계열 특징을 갖는 선박용 공기 압축기 전류 데이터의 이상 탐지 알고리즘 적용 실험)

  • Lee, Jung-Hyung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.127-134
    • /
    • 2021
  • In this study, an anomaly detection (AD) algorithm was implemented to detect the failure of a marine air compressor. A lab-scale experiment was designed to produce fault datasets (time-series electric current measurements) for 10 failure modes of the air compressor. The results demonstrated that the temporal pattern of the datasets showed periodicity with a different period, depending on the failure mode. An AD model with a convolutional autoencoder was developed and trained based on a normal operation dataset. The reconstruction error was used as the threshold for AD. The reconstruction error was noted to be dependent on the AD model and hyperparameter tuning. The AD model was applied to the synthetic dataset, which comprised both normal and abnormal conditions of the air compressor for validation. The AD model exhibited good detection performance on anomalies showing periodicity but poor performance on anomalies resulting from subtle load changes in the motor.

Ultrasonic Reflection Imaging for Discontinuity Detection of Rock Mass - Laboratory Study (암반 불연속면 탐측을 위한 초음파 반사 이미지 - 실내실험)

  • Lee, Jong-Sub;Kim, Seung-Sun;Kim, Dong-Hyun;Kim, Uk-Young;Lee, In-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.1
    • /
    • pp.51-65
    • /
    • 2007
  • The purpose of this study is the development and application of a high resolution ultrasonic wave imaging system to detect discontinuity plane in lab-scale rock models. This technique is based on received time series which capture the multiple reflections at interface. This study includes the fundamental aspects of ultrasonic wave propagation in rock mass, the selection of the optimal ultrasonic wave transducer, data gathering, a signal processing, imaging methods, and experiments. Experiments are carried out by the horizontal movement and rotation devices. Experimental studies show the discontinuity is well detected by the horizontal movement and rotation devices under water. Furthermore, the discontinuity and the cavity on the plaster block are identified by the rotation device. This study suggests that the new method may be an economical and effective tool for the detection of the discontinuity on rock mass.

Water Digital Twin for High-tech Electronics Industrial Wastewater Treatment System (II): e-ASM Calibration, Effluent Prediction, Process selection, and Design (첨단 전자산업 폐수처리시설의 Water Digital Twin(II): e-ASM 모델 보정, 수질 예측, 공정 선택과 설계)

  • Heo, SungKu;Jeong, Chanhyeok;Lee, Nahui;Shim, Yerim;Woo, TaeYong;Kim, JeongIn;Yoo, ChangKyoo
    • Clean Technology
    • /
    • v.28 no.1
    • /
    • pp.79-93
    • /
    • 2022
  • In this study, an electronics industrial wastewater activated sludge model (e-ASM) to be used as a Water Digital Twin was calibrated based on real high-tech electronics industrial wastewater treatment measurements from lab-scale and pilot-scale reactors, and examined for its treatment performance, effluent quality prediction, and optimal process selection. For specialized modeling of a high-tech electronics industrial wastewater treatment system, the kinetic parameters of the e-ASM were identified by a sensitivity analysis and calibrated by the multiple response surface method (MRS). The calibrated e-ASM showed a high compatibility of more than 90% with the experimental data from the lab-scale and pilot-scale processes. Four electronics industrial wastewater treatment processes-MLE, A2/O, 4-stage MLE-MBR, and Bardenpo-MBR-were implemented with the proposed Water Digital Twin to compare their removal efficiencies according to various electronics industrial wastewater characteristics. Bardenpo-MBR stably removed more than 90% of the chemical oxygen demand (COD) and showed the highest nitrogen removal efficiency. Furthermore, a high concentration of 1,800 mg L-1 T MAH influent could be 98% removed when the HRT of the Bardenpho-MBR process was more than 3 days. Hence, it is expected that the e-ASM in this study can be used as a Water Digital Twin platform with high compatibility in a variety of situations, including plant optimization, Water AI, and the selection of best available technology (BAT) for a sustainable high-tech electronics industry.

Enhancement of Dewaterability of Sewage Sludge by Ultrasonification and Electric Field Treatment (초음파와 전기장 처리에 의한 하수슬러지 탈수성 향상)

  • Mo, Woojong;Han, Jisun;Ahn, Changmin;Yoon, Soonuk;Seok, Heejung;Kim, Changgyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.23-30
    • /
    • 2013
  • The sludge disposal is a major economic factor in the sewage treatment facility operation. Moreover, since the ocean dumping will be prohibited by Korean environmental law from 2013, sludge should be eliminated or sludge volumetric reduction should be performed urgently. In this study, improvement of the sewage sludge dewaterability was investigated by ultrasound and electric field treatment. Sludge was treated by a single or in combination of either the electric field or ultrasound on a pilot pretreatment facility, then it was dewatered by lab-scale filter press. The operating input energy of ultrasound device was varied from 225~1,200 kJ/L and electric field device was varied from 4.5~24 kJ/L. The water contents of dewatered sludge cake treated with ultrasound (1,200 kJ/L) and combination of ultrasound/electric field (1,224 kJ/L) were decreased 10~12% by comparing non-treated sludge. At that time, water contents were 65~66%. The combination treatment of ultrasound/electric field was effective to reduce water content of dewatered sludge cake, however, water content was not changed by a single treatment of electric field because of low energy density.

Treatment of Spent ion-Exchange Resins from NPP by Supercritical Water Oxidation(SCWO) Process (초임계수 산화공정에 의한 원전 폐수지 처리기술)

  • Kim, Kyeong-Sook;Son, Soon-Hwan;Song, Kyu-Min;Han, Joo-Hee;Han, Kee-Do;Do, Seung-Hoe
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.3
    • /
    • pp.175-182
    • /
    • 2009
  • The spent cationic exchange resins and anionic exchange resins were separated from mixed spent exchange resins by a fluidized bed gravimetric separator. The separated resins were identified by an elemental analysis and thermogravimetric analysis. The each test sample was prepared by diluting the slurry made by wet ball milling the cationic exchange resins and the anionic exchange resins separated as a spherical granular form for 24 hours. The resulting test samples showed a slurry form of less than $75{\mu}m$ of particle size and 25,000ppm of $COD_{cr}$. The decomposition conditions of each test samples from a thermal power plant were obtained with a lab-scale(reactor volume : 220mL) supercritical water oxidation(SCWO) facility. Then pilot plant(reactor volume : 24 L) tests were performed with the test samples from a thermal power plant and a nuclear power plant successively. Based on the optimal decomposition conditions and the operation experiences by lab-scale facility and the pilot plant, a commercial plant(capacity : 150kg/h) can be installed in a nuclear power plant was designed.

  • PDF

Assessment of temperature-dependent water quality reaction coefficients and monthly variability of residual chlorine in water distribution networks (수온 변화에 따른 상수관망 내 수질반응계수 추정 및 월별 잔류염소농도 분포 변화 분석)

  • Jeong, Gimoon;Choi, Taeho;Kang, Doosun;Lee, Juwon;Hwang, Taemun
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.705-720
    • /
    • 2023
  • In South Korea, ongoing incidents related to drinking water quality have eroded consumer trust. Specifically, beyond quality incidents, there have been complaints about taste, odor, and other issues stemming from the presence of chlorine. To address this, water service operators are employing various management strategies from both temporal (scheduling) and spatial (rechlorination) perspectives to ensure uniform and safe distribution of chlorine residuals. In this study, we focus on the optimal monthly management of chlorine residuals, based on water distribution network analysis. Water quality reaction coefficients, including bulk fluid and wall reaction coefficients, were estimated through lab-scale tests and EPANET water quality simulations, respectively, accounting for temperature variations in a large-scale water distribution network. Utilizing these estimated coefficients, we examined the monthly variations in chlorine residual distribution under different chlorine injection conditions. The results indicate that the efficient concentration for chlorine injection, which satisfies the residual chlorine limit range, varies with temperature changes. Consequently, it is imperative to establish a specific and quantitative chlorine injection plan that considers the accurate spatial distribution of monthly chlorine residuals.