• 제목/요약/키워드: LTT

검색결과 18건 처리시간 0.025초

고강도 강판 저항 점용접부 강도 및 파단에 미치는 Paint Baking의 영향 (The Effect of Paint Baking on the Strength and Failure of Spot Welds for Advanced High Strength Steels)

  • 최철영;이동윤;김인배;김양도;박영도
    • 대한금속재료학회지
    • /
    • 제49권12호
    • /
    • pp.967-976
    • /
    • 2011
  • Conventional fracture tests of resistance spot welds have been performed without consideration of the paint baking process in the automobile manufacturing line. The aim of this paper is to investigate the effect of the paint baking process on load carrying capacity and fracture mode for resistance spot welded 590 dual phase (DP), 780DP, 980DP, 590 transformation in duced plasticity (TRIP), 780TRIP and 1180 complex phase (CP) steels. With paint baking after resistance spot welding, the l-shape tensile test (LTT) and nano-indentation test were conducted on the as-welded and paint baked samples. Paint baking increased the load-carrying capacity of the resistance spot welded samples and improved the fracture appearance from partial interfacial fracture (PIF) to button fracture (BF). Improvement in fracture appearance after LTT is observed on weldments of 780 MPa grade TRIP steels, especially in the low welding current range with paint baking conditions. The higher carbon contents (or carbon equivalent) are attributed to the low weldability of the resistance spot welding of high strength steels. Improvement of the fracture mode and load carrying ability has been achieved with ferrite hardening and carbide formation during the paint baking process. The average nano-indentation hardness profile for each weld zone shows hardening of the base metal and softening of the heat affected zone (HAZ) and the weld metal, which proves that microstructural changes occur during low temperature heat treatment.

Immunomodulatory Response Induced by Ginseng

  • Kumar, Ashok
    • Journal of Ginseng Research
    • /
    • 제27권3호
    • /
    • pp.115-119
    • /
    • 2003
  • There has been continuing interest in the development of synthetic and natural compounds that modify the immune response particularly for the treatment of AIDS and cancer. During the past fifty years, numerous scientific studies have been published on ginseng. Modem human studies have investigated preventive effect of ginseng on several kinds of cancer, its long term immunological effect on HIV patients, its effect on cell mediated immune functions in healthy volunteers. Similarly non clinical studies on animal model system have studied the chemopreventive action of ginseng on cancer and immunological properties of ginseng. The precise mechanism of action of ginseng, however, not clearly understood. Considering its wide-ranging therapeutic effects, this study is being undertaken to elucidate the general mode of action of ginseng, especially to test our hypothesis that its biological action may be mediated by the immune system.

펄스전력용 광점호 싸이리스터의 특성 연구 (A Study on Characteristics of Light Triggered Thyristor for Pulsed Power Application)

  • 이병하;김진성;김영배;차한주
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.762-767
    • /
    • 2010
  • This paper describes characteristic of a light triggered thyristor investigated by experiment to adopt it into a main switch of a pulsed power unit. Triggering principle of the light triggered thyristor are referred with its structure and equivalent circuit. Operational principle and simulation result of a capacitive pulsed power circuit are explained. A variety of triggering conditions of triggering circuit and characteristics on turn-on, turn-off, voltage dividing in series operation, overvoltage protection function of the light triggered thyristor are investigated by experiments. Experimental result of 40 kJ pulsed power unit using the light triggered thyristor is presented.

봉독침자극(蜂毒鍼刺戟)이 생쥐의 면역기능(免疫機能)에 미치는 영향(影響) (Effect of Api-Toxin Therapy on Depression of Immune Response in Mice)

  • 강승범;고형균;김창환
    • 대한한의학회지
    • /
    • 제17권1호
    • /
    • pp.234-246
    • /
    • 1996
  • In order to investigate the effects of api-toxin therapy on depression of immune response, mice were exposed to cold stress $(-20^{\circ}C)$) in 30 minutes twice a day and api-toxin(Bee Venom from Korea and U.S.A) therapy was treated to the Kihae $(CV_6)$ locus of human body every two days with 4 sessions of treatment for 8 days. The mice were sensitized i.v. with $5{\times}10^8$ sheep red blood cells (SRBC) on the 4th day and challenged i.d. with $2{\times}10^9$ SRBC 4 days later. Immune Response for delayed type hypersensitivity (DTH), lympocyte transformation(LTT), hemolysin titer(HL), plaque forming cells (PFC) were measured.

  • PDF

Low Temperature (LT) GaAs 에피층의 성장과 그 특성연구 (The Growth and Its Characteristics of Low Temperature (LT. $250^{\circ}C$) GaAS Epilayer)

  • 김태근;박정호;조훈영;민석기
    • 전자공학회논문지A
    • /
    • 제31A권9호
    • /
    • pp.96-103
    • /
    • 1994
  • The GaAs epilayer was grown at low temperature (LT. 250.deg. C) by molecular beam epitaxy. The properties of the LTT GaAs, before and after Rapid Thermal Annealing(RTA), were analyzed by Reflection of High Energy Electron Diffraction (RHEED), Double Crystal X-ray(DCX), Raman spectroscopy, PL and Photo-Induced Current Transient Spectroscopy (PICTS). The LT GaAs before RTA, was analyzed by RHEED and DCX, with a result of an improved surface morphology under a relatively As-rich(As/Ga ratio :28) condition, and of an increased lattics parameter of 1.1 1.7% in comparison with a GaAs substrate. However DCX and Raman spectroscopy revealed that the expanded lattics parameter and the crystallinity of LT GaAs could be recovered after RTA. On the other hand, PL spectra indicated that LT GaAs after RTA showed low optical sensitivity unlike High Temperature(HT) GaAs, and that its surface morphology and crystallinity were corresponded with those of HT GaAs. Finally PICTS spectra proved the fact that low sensitivity of LT GaAs was due to the deep level defects (Ec-0.85eV) which were strogly formed by raising RTA temperature to 750.deg. C.

  • PDF

임베디드 커널 추적 도구를 이용한 임베디드 시스템 성능 측정 기법 (A Scheme of Embedded System Performance Evaluations Using Embedded Kernel Trace Toolkit)

  • 배지혜;윤남식;박윤용
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제13권7호
    • /
    • pp.462-475
    • /
    • 2007
  • 임베디드 시스템은 정보, 교육, 산업, 서비스 등의 많은 분야에서 인간 중심의 서비스를 제공하고 있으며 이러한 임베디드 시스템의 관리, 제어, 통제 및 테스트를 위한 모니터링 프로그램이 다양하게 개발되고 있다. 모니터링을 하기 위해서는 여러 가지 커널 추적 도구를 사용하는데 본 논문에서는 기존의 커널 추적 도구와 비교하여 임베디드 시스템에 초점을 맞춘 커널 추적 도구인 $ETT^{plus}$를 제시하며, 임베디드 타겟과 호스트와의 추적 데이타 전송 방법을 제시하고자 한다. $ETT^{plus}$는 기존의 추적 도구가 가지고 있는 어려운 커널 패치 문제, 파일 시스템 사용 의존성 문제 등에 대한 해결 방안을 제공하고 있으며 $ETT^{plus}$를 이용하여 시스템 콜 수행 시간이나 네트워크 데이타 전송 시간과 같은 임베디드 시스템의 성능 측정 비교에 대한 설계 및 분석 결과를 제시한다.

Effect of Dietary Vitamin E Supplementation on Serum α-Tocopherol and Immune Status of Crossbred Calves

  • Samanta, A.K.;Dass, R.S.;Rawat, Mayank;Mishra, S.C.;Mehra, U.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제19권4호
    • /
    • pp.500-506
    • /
    • 2006
  • An experiment was conducted with twenty crossbred male calves (7-15 days old) divided into 4 different experimental groups on the basis of body weights to study the effect of vitamin E supplementation on the serum ${\alpha}$-tocopherol concentration and immune response of the calves. All the calves were fed on milk and calf starter up to 13 weeks and afterwards, they were fed on concentrate mixture and oat hay up to 32 weeks of age. In addition, the calves in groups I, II, III and IV were supplemented with 0, 125, 250 and 500 IU feed grade DL-${\alpha}$-tocopheryl acetate, respectively. Blood samples were collected at 0 day and subsequently at 1, 2, 3, 4, 6 and 8 months of age to monitor the serum ${\alpha}$-tocopherol concentration in crossbred calves. After 24 weeks of experimental feeding, 4 animals from each group were intramuscularly inoculated with single dose (3 ml) of Haemorrhagic septiceaemia (Pasteurella multocida P52 strain) oil adjuvant vaccine. The cumulative group mean serum ${\alpha}$-tocopherol concentration (${\mu}g/100ml$) was 88.12, 210.11, 235.21 and 294.02 in-groups I, II, III and IV, respectively and differed significantly (p<0.001) among the four groups. Lymphocyte stimulation indices (LSI) did not differ among the groups significantly. The pooled mean ELISA antibody titer against Pasteurella multocida (P52 strain) was 788.02, 926.85, 1,214.00 and 1,109.51 for group I, II, III and IV, respectively, which indicated higher antibody titer in groups supplemented with vitamin E as compared to the control group. It may be concluded that vitamin E supplementation increased the ${\alpha}$-tocopherol concentration in serum and dietary supplementation of vitamin E at higher level has a humoral immune enhancing effect against killed bacterial antigen.

자동차 차체용 TRIP강판의 저항 점용접부 Partial Interfacial Fracture 특성에 관한 연구 (Characterization of Partial Interfacial Fracture on Resistance Spot-Welded TRIP Steels for Automotive Applications)

  • 최철영;김인배;김양도;박영도
    • 대한금속재료학회지
    • /
    • 제50권2호
    • /
    • pp.136-145
    • /
    • 2012
  • Resistance spot welding of TRIP780 steels was investigated to enhance understanding of weld fracture mode after tensile shear testing (TST) and L-shape tensile testing (LTT). The main failure mode for spot welds of TRIP780 steels was partial interfacial fracture (PIF). Although PIF does not satisfy the minimum button diameter (4${\surd}$t) for acceptable welds, it shows enough load carrying capacity of resistance spot welds for advanced high strength steels. In the analysis of displacement controlled L-shape tensile test results, cracks initiated at the notch of the faying surface and propagated through the interface of weldments, and finally, cracks change path into the sheet thickness direction. Use of the ductility ratio and CE analysis suggested that the occurrence of PIF is closely related to high hardness and brittle welds, which are caused by fast cooling rates and high chemical compositions of TRIP steels. Analysis of the hold time and weld time in a welding schedule demonstrated that careful control of the cooling rate and the size of a weld nugget and the HAZ zone can reduce the occurrence of PIF, which leads to sound welds with button fractures (BFs).