• Title/Summary/Keyword: LPG storage tank

Search Result 38, Processing Time 0.02 seconds

Analytical Study on Strength Safety of LPG Mini Tank with Column for Level Gauge (레벨게이지용 컬럼을 설치한 LPG 미니탱크의 강도안전성에 관한 해석적 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.46-50
    • /
    • 2019
  • In this study, the strength stability of an LPG mini tank with a storage capacity of about 250 kg was analyzed by FEM. According to the results of the FEM analysis, it is preferable that the corner radius of the LPG mini tank having a storage capacity of 250 kg is designed to be 175 to 205 mm. Generally, the larger the corner radius of the end plate of the gas storage tank, the higher the safety of the strength, but the volume or capacity of the tank is reduced. Therefore, it is important to derive the optimum design data. Further, in order to securely design the strength of the gas tank, the thickness of the tank is designed to be thick. However, when the thick steel sheet is used, the material and the transportation costs are increased. The result shows that it is preferable to select the optimum thickness of the steel sheet from 4.5 to 5.5 mm. Using the level gauge type of column on the central axis of the gas tank, the safety strength of the LPG tank can be enhanced as much as twice, compared with the tank of the existing level gauge to measure the liquid level by piercing the side wall of the tank.

A Study on the Optimal Installation Technology of LPG Storage Tank through Taguchi Method (다구찌 기법을 통한 LPG 저장탱크시공방법의 최적화에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Paek, Seung-Cheol;Lee, Jong-Rark
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.98-102
    • /
    • 2010
  • LPG (Liquefied Petroleum Gas) vehicles in metropolitan area are being applied to improve air quality and have been proven effective for the reduction of air pollutant. In addition, the demand of gas as an eco-friendly energy source has being increased. With the LPG filling station is also increasing every year. These gas stations are required to install the securest storage tank because of possibility of causing huge loss of life and property. Therefore, in this paper, underground containment type is proposed as installation of the LPG storage tank using Taguchi method, which is considered to be more safe, economical, efficient, easy checking and simple construction method than any other. If leakage, economics, real estate utilization rate, safety, easy to check, simple construct about above ground, buried underground and underground containment storage tank are analyzed by Taguchi method, real estate utilization rate, economic and safety in turn are improved. Therefore, the underground containment storage tank is a optimal installation technology.

A Study on the Prediction of the Maximum Evaporation Rates from LPG Storage Tanks (소형저장탱크의 가스발생능력에 관한 연구)

  • Lee Kyung-Sik;Yu Kwang-Soo;Jo Young-Do;Park Kyo-Shik
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.1 s.30
    • /
    • pp.7-12
    • /
    • 2006
  • The quantity of gas which can be supplied by LPG storage tank become a standard of selection. In the absence of the maximum evaporation rates from LPG storage tanks by tank capacity, continuation using time, air temperature, it is in a problem for the dissemination of LPG Storage tanks. In this paper, we showed the maximum evaporation rates from LPG storage tanks by tank capacity, air temperature, continuous using time and remaining level.

  • PDF

The Optimal Design of Explosion Prevention for LPG Storage Tank (폭발방지를 고려한 LPG 저장탱크 최적설계)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Son, Seok-Woo;Lim, Jae-Ki
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.949-952
    • /
    • 2010
  • The utilization of LPG(Liquefied Petroleum Gas) is increasing as an environmental-friendly fuel in all countries making green growth new paradigm, and use of gas is spread fast as motor fuels to decrease air pollution. Loss of lives by explosion and fire is happening every year as gas use increases, and gas accident in large scale storage property is causing serious problems socially. To minimize this problem, underground containment type storage tank is being presented as an alternative recently. In this study, to minimize explosion occurrence in underground containment type storage tank, the suitable storage tank is designed to consider explosion prevention that makes exposure surface area minimize in confined contents volume and flame to construct storage tank by the most suitable condition in the underground containment room. As a result of the design of storage tank having the most suitable condition by this research, underground containment space was minimized on diameter 3m, length 4.83m in 20 tons storage tank and its safety was improved as exposure surface area in flame decreased by 89.4%, compared with the existent storage tank.

  • PDF

A Study on the Safety of Small LPG Storage Tanks at External Fires (외부화재시 LPG 소형저장탱크의 안전성에 관한 연구)

  • Yim, Ji-Pyo;Ma, Byung-Chol;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.64-72
    • /
    • 2015
  • The purpose of this study is to study the safety of a small LPG storage tank with a capacity less than 3 ton when it is exposed to an external fire. First, simulation studies were carried out using ASPEN Plus and PHAST to demonstrate that overpressurization in the tank can be relieved by discharging the LPG through an adequately sized safety valve, but the release may lead to the secondary risk of fire and explosion around the tank. Next, the temporal variations of the temperatures of the lading and tank wall were obtained using AFFTAC, which showed that the tank wall adjacent to the vapor space could be overheated in about 11 min to such a point that the weakened strength might cause a rupture of the tank and subsequent BLEVE. The consequences of the BLEVE were estimated using PHAST. Finally, several practical measures for preventing the hazards of overheating were suggested, including an anti-explosion device, sprinkling system, insulation, heat-proof coating, and enhanced safety factor for tank fabrication. The effectiveness of these measures were examined by simulations using AFFTAC and ASPEN Plus.

A Study on the Risk Assessment in LPG Transportation by Tank Lorry (LPG 탱크로리 수송중 위험성 평가에 관한 연구)

  • 이재준;김윤화;윤성렬;엄성인;백종배;고재욱
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.86-92
    • /
    • 1997
  • Demand of LPG and LNG will increase continuously due to high calories, clearness, and convenience for usage. These gases are used widely for power plants, industrial plants, and domestic fuel. But accidents related with gas are increasing in proportion to increment of gas usage. Especially LPG has high ignitability due to weak dispersion to air and accumulation at low place because LPG is heavier than air. There are many hazards during transportation as well as production, storage, and usage of LPG. Commonly, tank lorry is used for inland transportation of LPG. If tank lorry were to raise leakage incidents and then LPG released during transporting, the accidents cause serious effects on the environment as well as human damage of surrounding area. In this study, therefore, hazards which cause LPG of tank lorry to leak during transportation were identified and risk of LPG transportation was assessed quantitatively. Also, the result of this study might be a useful measure for predicting damage and preparing safe transportation strategies of LPG tank lorry.

  • PDF

Development of a Tool for Predicting the Occurrence Time of BLEVE in Small LPG Storage Tanks (LPG소형저장탱크 BLEVE 발생 시점 예측 툴 개발)

  • Chae, Chung Keun;Lee, Jae Hun;Chae, Seung Been;Kim, Yong Gyu;Han, Shin Tak
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.74-83
    • /
    • 2020
  • In Korea, about 110,000 LPG small storage tanks of less than three tons have been installed in restaurants, houses and factories, and are used as LPG supply facilities for cooking, heating and industrial use. In the case of combustible liquefied gas storage tanks, the tank may rupture due to the temperature increase of the tank steel plate (approximately 600℃) even when the safety valve is operating normally, causing large-scale damage in an instant. Therefore, in the event of a fire near the LPG small storage tank, it is necessary to accurately predict the timing of the BLEVE(Boiling Liquid Expanding Vapour Explosion) outbreak in order to secure golden time for lifesaving and safely carry out fire extinguishing activities. In this study, we have first investigated the results of a prior study on the prediction of the occurrence of BLEVE in the horizontal tanks. And we have developed thermodynamic models and simulation program on the prediction of BLEVE that can be applied to vertical tanks used in Korea, have studied the effects of the safety valve's ability to vent, heat flux strength of external fires, size of tanks, and gas remaining in tanks on the time of BLEVE occurrence and have suggested future utilization measures.

A Study on the Quantitative Analysis for Explosion of LPG Storage Tank (LPG 저장탱크의 폭발에 대한 정량적 영향평가에 관한 연구)

  • Leem, Sa Hwan;Huh, Yong Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2013
  • The influence of the over-pressure caused by Explosion in gas station was calculated by using the Hopkinson's scaling law and injury effect by accident to buildings and human bodies was estimated by applying the probit model. As a result, the injury estimation was conducted by using the probit model for leakage 10% of 20ton storage tank. The separate distances from LPG station for building(damage) and human(lung hemorrhage to death) are 260 and 30 meters, respectively.

Impact Range Analysis of Small LPG Storage Tank Explosions at Highway Rest Areas (고속도로 휴게소 소형 LPG 저장탱크 폭발에 따른 영향범위 분석)

  • Seung duk Jeon;Soon Beom Lee;Jai Young Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.319-327
    • /
    • 2023
  • This study analyzes the risks of explosions of small LPG storage tanks installed at highway rest areas. For this purpose, the ranges of the effect of thermal radiation and overpressure caused by the BLEVE(Boiling Liquid Expansion Vapor Explosion)and VCE(Vapor Cloud Explosion) of a 2900-kg small LPG storage tank installed at highway rest areas were quantitatively evaluated by applying the Areal Location of Hazardous Atmospheres program. The ranges of influence of the derived explosion overpressure and thermal radiation were found to have a maximum radii of 336 m and 423 m, respectively. The study determined that those within 269 m could be severely injured by an explosion overpressure of 3.5 psi, and fatalities from thermal radiation of 10 kw/m2 could occur within 192 m of the exploded storage tank. The safety management plan for the LPG storage tank was discussed while considering the auxiliary facilities of highway rest areas and the extent of the damage impact. These research results will help improve safety accident prevention regulations considering the environment and facilities of the rest areas as well as the safety management of small LPG storage tanks installed at highway rest areas.