Loss of a Main Feedwater Pump Test at 100% Power Simulation using Korean Standard Nuclear Plant Analyzer (KSNPA)

  • Jeong, Won-Sang;Kim, Shin-Whan;Sung, Kang-Sik;Seo, Jong-Tae;Lee, Sang-Keun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.296-302
    • /
    • 1996
  • The Loss of a Main Feedwater Pump test at 100% Power for YGN 4 was simulated in order to verify and validate the KSNPA. The comparison of the test data with the KSNPA prediction results showed reasonable agreement in the trends of the major plant parameters. All plant control systems including NSSS and T/G control systems are properly actuated and stabilized the plant conditions to a new steady state conditions in the KSNPA. From the comparison results, the KSNPA showed its capability to simulate the LOMFP event for the Korean Standard Nuclear Power Plant.

  • PDF

The Performance Evaluation of NSSS Control Systems for UCN 4

  • Sohn, Suk-Whun;Song, In-Ho;Sohn, Jong-Joo;Park, Jong-Ho;Seo, Jong-Tae
    • Nuclear Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.339-348
    • /
    • 2001
  • NSSS Control Systems automatically mitigate transient conditions and leads to a stable plant condition without operator actions when a transient occurs during normal power operation. In this paper, the function and performance of NSSS control systems were examined and evaluated by comparing the predicted results with the measured data for the selected events. Loss of a Main Feedwater Pump and Load Rejection to House Load Operation events were selected for the evaluation among the transient tests peformed during the Power Ascension Test (PAT) of UCN unit 4. The overall schematic control actions of NSSS control systems can be evaluated easily through the observation of these two typical events. The selected events were analyzed by the KISPAC computer code[l] which had been used in developing the control logic and determining the control setpoints during the plant design. Additionally, the performance of FWCS during low power operation was evaluated. The result of evaluation showed that the NSSS control systems were designed properly and the performance of the NSSS control systems was excellent and also the computer code had a good prediction capability.

  • PDF