• 제목/요약/키워드: LOAD CELL

검색결과 1,188건 처리시간 0.037초

연료전지 시스템을 이용한 전기철도 급전계통 전압강하 보상 (The Voltage Drop Compensation of Electric Railway Feeding system using a Fuelcell System)

  • 김재문
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.342-348
    • /
    • 2015
  • In this paper, fuel cell power generation system that is being studied in recent railway field was applied to compensate for the voltage drop due to the load as driving electric vehicle. PSIM simulation program is to be used to implement the modeling of the electric railway for AC AT feeder system. For it, It was applied to the product-type single-phase PLL algorithm, step-down converter is controlled as power so as to have the fuelcell generation system. Based on it's result, a reactive power due to the catenary impedance in accordance with the current flowing is compensated as linked with fuelcell generation system which supplied the current to the power supply grid. and then its performance was confirmed that voltage compensation effect obtained at SubStation (SS), SubSectioning Post (SSP), Sectioning Post (SP).

LED를 광송수신 소자로 사용한 수동형 가시광 트랜스폰더 (A Passive Visible Light Transponder Using an LED for an Optical Transceiver)

  • 이성호
    • 센서학회지
    • /
    • 제24권4호
    • /
    • pp.232-238
    • /
    • 2015
  • In this paper, we introduce a passive transponder in which an LED is used for both a light transmitter and a receiver, and a solar cell is used for supplying power to the all devices in the transponder. The LED in the transponder operates as a photodetector in the receiving mode, and acts as a light source in the transmitting mode. The current responsivity of the LED detector was measured to be in the order of $10^{-4}A/W$, and the receiving bandwidth with a load resistance of $10k{\Omega}$ was about 10 to 30 kHz. Using the LED for an optical transceiver in a VLID transponder, the detection range was about 70 cm when the transponder was illuminated by the visible light from a $3{\times}3$ LED array in a reader.

Single Cell Li-ion 전지 충전 IC (A Single Cell Li-ion Battery Charger)

  • 이락현;김준식;박시홍
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.27-28
    • /
    • 2009
  • This paper suggests a autonomous linear Li-ion battery charger which can safely distribute power between an external power source(AC adapter, auto adapter, or USB source), battery, and the system load. Depending on an external power source's capability, the charger selects proper charging-mode automatically. The charger IC designed and fabricated on Dongbu HITEC's $0.35{\mu}m$ BCD process with layers of one poly and three metals.

  • PDF

Droop Method를 이용한 50[W]급 태양전지 가상구현 시스템의 병렬연결 출력특성에 대한 연구 (A Study Of Parallel Characteristics Of 50[W] Virtual Implement of 50[W]Solar Cell modules Using Droop-Method)

  • 이병인;이상용;오방원;정병환;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.692-695
    • /
    • 2003
  • Generally, photovoltaic system is composed with several solar cell modules. For increasing power of photovoltaic systems, serial and parallel connection needed. A Desirable characteristic of a parallel supply system is that individual converters share the load current equally and stably. The current sharing(CS) can be implemented using two approaches. The first one, known as a droop method, relies on the high output impedance of each converter. and The second approach, known as active current-sharing techniques. In this paper, using droop method at parallel connection with it's convenience and simplicity.

  • PDF

Resource Reservation to Support Service Continuity in OFDMA Systems

  • Lee, Jongchan;Lee, Moonho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권12호
    • /
    • pp.4356-4371
    • /
    • 2014
  • When the load in a multi-cell orthogonal frequency division multiple access (OFDMA) system is allowed to excessively increase in face of frequent handover, the cell area becomes smaller than the designed size, and thus continuity of quality of service (QoS) for handover requests cannot be guaranteed. To efficiently support the mobility of a mobile terminal (MT), we should adaptively cope with the resource demand of handover calls. This paper proposes a twofold resource-reservation scheme for OFDMA systems to guarantee continuity of QoS for various mobile multimedia services during MT handover from lightly to heavily loaded cells. Our twofold scheme attempts to guarantee service continuity for handover and to maximize resource allocation efficiency. We performed a simulation to evaluate our scheme in terms of outage probability, handover failure rate, total throughput, and blocking rate.

LGE's Strategy for PDP TV

  • Kim, Jae-Sung;Lee, Sung-Hyun;Ahn, Sung-Yong;Ahn, Young-Joon;Ryu, Jae-Hwa;Yoon, Kwang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.71-74
    • /
    • 2005
  • There have been various efforts to achieve a better PDP TV, which have low power consumption, high image quality and low price. As the results, the power consumption of LG's new 42 inch HD PDP could be lower than 42 inch LCD under the general movie display load condition. And the address discharge time lag of ${\sim}1\;{\mu}s$ for 42 and 50 inch XGA single scan by which the cost can be reduced and image quality can be improved was achieved by using new MgO material and driving waveform. In addition, we have suggested TCA (Triangular Color pixel Arrangement) cell structure for realizing the full HDTV of 60inch diagonal size, which has $1920{\times}1080$ resolution. The luminous efficiency of the suggested TCA structure has been increased about 40% compared with that of the conventional cell structure.

  • PDF

강압쵸퍼에 의한 태양전지의 최대출력점 추적제어 (Maximum Power Tracking Control of Solar Cell by using the Step-down Chopper)

  • 성낙규;이승환;김성남;김용주;한경희;정연택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.351-353
    • /
    • 1994
  • The solar cell should be operated at the maximum power point every instant. Because this maximum power point is fluctuating due to the change in the insolation and temperature. In this paper, we propose a new maximum power' point tracker by using the microprocessor. The proposed step-down chopper system tracks always the maximum power point, regardless of the change in the insolation, temperature and load.

  • PDF

Time Slot Allocation for CDMA/TDD Indoor Wireless Systems

  • Lee Chae Y.;Sung Ki Won
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2002년도 춘계공동학술대회
    • /
    • pp.144-151
    • /
    • 2002
  • Future wireless communication systems are expected to provide a broad range of multimedia services in which the asymmetry of traffic load between uplink and downlink is a significant feature. The rode division multiple access system with tune division duplex mode (CDMA/TDD) is a good solution to cope with the traffic asymmetry problem. However. the TDD system is subject to inter-cell interference compared to frequency division duplex (FDD) system. Since both uplink and downlink share the same frequency in TDD. uplink and downlink may interfere each other especially when neighboring cells require different rates of asymmetry. Thus, time slot allocation for tells is an important issue in TDD. In this paper. we propose a genetic algorithm based time slot allocation scheme which maximizes the residual system capacity. The proposed scheme allows that each cell employ different level of uplink/downlink asymmetry and satisfies the interference requirement.

  • PDF

125kW 용융탄산염 연료전지 시스템 개발 (The Development of 125kW Molten Carbonate Fuel cell System)

  • 김범주
    • 기술사
    • /
    • 제44권1호
    • /
    • pp.48-52
    • /
    • 2011
  • The KEPCO Research Institute has developed Molten Carbonate Fuel Cell(MCFC) since 1993. Recently, an 125-kW MCFC system was operated at Boryeong thermal power plant, Korea from December, 2009 to March, 2010, This system is composed of an 125-kW stack, mechanical balance of plant (MBOP), and Power Conditioning System. The stack has 200 unit cells of which effective area is 10,000 cm2. Especially, MBOP is mainly made up of ejector and catalytic combustor which help this system to be supplied with cathode inlet gas using anode tail gas and fresh air. After the pretreatment of this system was performed for about 20 days, initial load operation was performed at January. 2010. Moreover, this system had been operated for 3,270 hours.

  • PDF

가정용 연료전지 시스템의 열관리 해석 (Thermal Management Study of PEMFC for Residential Power Generation)

  • 유상석;이영덕;안국영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2839-2844
    • /
    • 2008
  • A PEMFC(proton exchange membrane fuel cell) is a good candidate for residential power generation to be cope with the shortage of fossil fuel and green house gas emission. The attractive benefit of the PEMFC is to produce electric power as well as hot water for home usage. Typically, thermal management of vehicular PEMFC is to reject the heat from the PEMFC to the ambient air. Different from that, the thermal management of PEMFC for RPG is to utilize the heat of PEMFC so that the PEMFC can be operated at its optimal efficiency. In this study, dynamic thermal management system is modeled to understand the response of the thermal management system during dynamic operation. The thermal management system of PEMFC for RPGFC is composed of two cooling circuits, one for controling the fuel cell temperature and the other for heating up the water for home usage. Dynamic responses and operating strategies of the PEMFC system are investigated during load changes.

  • PDF