• Title/Summary/Keyword: LOAD CELL

Search Result 1,188, Processing Time 0.03 seconds

A New Cell Selection Scheme with Adaptive Bias for Ultra Dense Heterogeneous Mobile Communication Networks (초밀집 이종 이동 통신망을 위한 적응형 편향치를 활용한 새로운 셀 선택 기법)

  • Jo, Jung-Yeon;Ban, Tae-Won;Jung, Bang Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.63-66
    • /
    • 2015
  • As smart-phones become popular, mobile data traffic has been dramatically increasing and intensive researches on the next-generation mobile communication network is in progress to meet the increasing demand for mobile data traffic. In particular, heterogeneous network (HetNet) is attracting much interest because it can significantly enhance the network capacity by increasing the spatial resue with macro and small cells. In the HetNet, we have several problems such as load imbalance and interference because of the difference in transmit power between macro and small cells and cell range expansion (CRE) can mitigate the problems. In this paper, we propose a new cell selection scheme with adaptive cell range expansion bias (CREB) for ultra dense HetNet and we analyze the performance of the proposed scheme in terms of average cell transmission rate through system-level simulations and compare it with those of other schemes.

  • PDF

Increased Intestinal Epithelial Cell Turnover and Intestinal Motility in Gymnophalloides seoi-Infected C57BL/6 Mice

  • Lee, Sang Hyub;Jung, Bong-Kwang;Park, Jae-Hwan;Shin, Eun-Hee;Chai, Jong-Yil
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.3
    • /
    • pp.273-280
    • /
    • 2014
  • The changing patterns of goblet cell hyperplasia, intestinal epithelial cell turnover, and intestinal motility were studied in ICR and C57BL/6 mice infected with Gymnophalloides seoi (Digenea: Gymnophallidae). Whereas ICR mice retained G. seoi worms until day 7 post-infection (PI), C57BL/6 mice showed a rapid worm expulsion within day 3 PI. Immunosuppression with Depo-Medrol significantly delayed the worm expulsion in C57BL/6 mice. Goblet cell counts were increased in both strains of mice, peaking at day 1 PI in C57BL/6 mice and slowly increasing until day 7 PI in ICR mice. In C57BL/6 mice infected with G. seoi, newly proliferating intestinal epithelial cells were remarkably increased in the crypt, and the increase was the highest at day 1 PI. However, in ICR mice, newly proliferating intestinal epithelial cells increased slowly from day 1 to day 7 PI. Intestinal motility was increased in G. seoi-infected mice, and its chronological pattern was highly correlated with the worm load in both strains of mice. Meanwhile, immunosuppression of C57BL/6 mice abrogated the goblet cell proliferation, reduced the epithelial cell proliferation, and suppressed the intestinal motility. Goblet cell hyperplasia, increased intestinal epithelial cell turnover, and increased intestinal motility should be important mucosal defense mechanisms in G. seoi-infected C57BL/6 mice.

Toxoplasma gondii Induces Apoptosis via Endoplasmic Reticulum Stress-Derived Mitochondrial Pathway in Human Small Intestinal Epithelial Cell-Line

  • Wang, Hao;Li, Chunchao;Ye, Wei;Pan, Zhaobin;Sun, Jinhui;Deng, Mingzhu;Zhan, Weiqiang;Chu, Jiaqi
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.6
    • /
    • pp.573-583
    • /
    • 2021
  • Toxoplasma gondii, an intracellular protozoan parasite that infects one-third of the world's population, has been reported to hijack host cell apoptotic machinery and promote either an anti- or proapoptotic program depending on the parasite virulence and load and the host cell type. However, little is known about the regulation of human FHs 74 small intestinal epithelial cell viability in response to T. gondii infection. Here we show that T. gondii RH strain tachyzoite infection or ESP treatment of FHs 74 Int cells induced apoptosis, mitochondrial dysfunction and ER stress in host cells. Pretreatment with 4-PBA inhibited the expression or activation of key molecules involved in ER stress. In addition, both T. gondii and ESP challenge-induced mitochondrial dysfunction and cell death were dramatically suppressed in 4-PBA pretreated cells. Our study indicates that T. gondii infection induced ER stress in FHs 74 Int cells, which induced mitochondrial dysfunction followed by apoptosis. This may constitute a potential molecular mechanism responsible for the foodborne parasitic disease caused by T. gondii.

The Detection of ICD p24 Antigen Predicts Bad Prognosis in HIV-1 Infected Patients (인면역결핍바이러스 감염자에서 ICD-p24 항원 탐지가 CD4+T 세포수 및 예후에 미치는 영향)

  • Cho, Young-Keol;Lee, Hee-Jung
    • The Journal of Korean Society of Virology
    • /
    • v.26 no.2
    • /
    • pp.259-267
    • /
    • 1996
  • In order to evaluate the effect of viral load on the prognosis of human immunodeficiency virus-1 (HIV-1)-infected individuals, immune complex dissociated (ICD) serum p24 antigen (p24) by acid treatment was retrospectively measured for 50 HIV-infected patients for 60 months. Among them, 27 patients were p24 positive (p24+) above 25pg/ml for $40.4{\pm}12$ months and 23 patients were negative (p24-). Follow-up periods from HIV diagnosis were $63.0{\pm}19$ months (range; 40-112) for the p24+ and $68.4{\pm}19$ months (range; 38-106) for the p24-, respectively (P>0.05)Mean CD4+T cell counts in the p24+ group decreased from $473{\pm}$277/ul (median;373) to $157{\pm}150/ul$ (median; 111) for $60{\pm}16$ months (5.3/month P280/ul (median; 476) to $432{\pm}285/ul$ (median;382) for $63{\pm}19$ months (2.5/month, P<0.01). From CD4+T cell count >200/ul, the patient who progressed to AIDS of <200/ul were 13 of 23 (56%) in the p24+ and 4 of 22 (18%) in p24-, respectively (p<0.01). And the number of death in two groups were 6 (22%) and 1 (4%), respectively (p<0.01). Presumed survival in two groups were about 12 and 24.5 years. These data suggest that viral load itself be very important for the prognosis of HIV-infected patients.

  • PDF

Analysis of Process Parameters on Cell Capacitances of Memory Devices (메모리 소자의 셀 커패시턴스에 미치는 공정 파라미터 해석)

  • Chung, Yeun-Gun;Kang, Seong-Jun;Joung, Yang-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.791-796
    • /
    • 2017
  • In this study, we investigated the influence of the fabrication process of stacked capacitors on the cell capacitance by using Load Lock (L/L) LPCVD system for dielectric thin film of DRAM capacitor. As a result, it was confirmed that the capacitance difference of about 3-4 fF is obtained by reducing the effective thickness of the oxide film by about $6{\AA}$ compared to the conventional non-L/L device. In addition, Cs was found to be about 3-6 fF lower than the calculated value, even though the measurement range of the thickness of the nitride film as an insulating film was in a normal management range. This is because the node poly FI CD is managed at the upper limit of the spec, resulting in a decrease in cell surface area, which indicates a Cs reduction of about 2fF. Therefore, it is necessary to control the thickness of insulating film and CD management within 10% of the spec center value in order to secure stable Cs.

Hard Handover Algorithm for Self Optimization in 3GPP LTE System (3GPP LTE 시스템에서 기지국 구성 자동 설정 동작을 위한 하드 핸드오버 알고리즘)

  • Lee, Doo-Won;Hyun, Kwang-Min;Kim, Dong-Hoi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.3A
    • /
    • pp.217-224
    • /
    • 2010
  • In this paper, we propose a hard handover algorithm for a base station's self-optimization, one of the automatic operational technologies for the 3GPP LTE systems. The proposed algorithm simultaneously considers a mixed target sell selection method for optimal selection and a multiple parameter based active hysteresis method with the received signal strength from adjacent cells and the cell load information of the candidate target cells from information exchanges between eNBs through X2 interface. The active hysteresis method chooses optimal handover hysteresis value considering the costs of the various environmental parameters effect to handover performance. The algorithm works on the optimal target cell and the hysteresis value selections for a base station's automatic operational optimization of the LTE system with the gathered informaton effects to the handover performance. The simulation results show distinguished handover performances in terms of the most important performance indexes of handover, handover failure rate and load balancing.

Preparation and Characterization of Palladium Nanoparticles Supported on Nickel Hexacyanoferrate for Fuel Cell Application

  • Choi, Kwang-Hyun;Shokouhimehr, Mohammadreza;Kang, Yun Sik;Chung, Dong Young;Chung, Young-Hoon;Ahn, Minjeh;Sung, Yung-Eun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1195-1198
    • /
    • 2013
  • Nickel hexacyanoferrate supported palladium nanoparticles (Pd-NiHCF NPs) were synthesized and studied for oxygen reduction reactions in direct methanol fuel cell. The NiHCF support was readily synthesized by a comixing of $Ni(OCOCH_3)_2$ and equimolar $K_3[Fe(CN)_6]$ solution into DI water under rigorous stirring. After the preparation of NiHCF support, Pd NPs were loaded on NiHCF via L-ascorbic acid reduction method at $80^{\circ}C$. Pd-NiHCF NPs were electrochemically active for oxygen reduction reaction in 0.1 M $HClO_4$ solution. X-ray absorption near edge structure analysis was conducted to measure the white line intensity of Pd-NiHCF to verify the OH adsorption. As a comparison, carbon supported Pd NPs exhibited same white line intensity. This study provides a general synthetic approach to easily load Pd NPs on porous coordination polymers such as NiHCF and can provide further light to load Pd based alloy NPs on NiHCF framework.

Rotordynamic Performance Measurements of a Two-Pad Beam-Type Gas Foil Journal Bearing for High Speed Motors (고속 전동기용 2 패드 빔 타입 가스 포일 저널 베어링의 회전체동역학 성능 측정)

  • Jeong, Kwon Jong;Hwang, Sung Ho;Baek, Doo San;Kim, Tae Young;Kim, Tae Ho
    • Tribology and Lubricants
    • /
    • v.38 no.5
    • /
    • pp.205-212
    • /
    • 2022
  • This paper presents experimental measurements of the structural characteristics of a two-pad beam-type gas foil journal bearing and its rotordynamic performance for a high-speed motor-driven turbocompressor. The test bearing had two top foils and two beam foils, each with an arc length of ~180°. Each beam foil was etched to obtain 40 beams with six geometries of different lengths and widths. The insertion of beam foils into the bearing housing produces equivalent beam heights. The structural tests of the bearing with a non-rotating journal revealed a smaller bearing clearance and larger structural stiffness for the load-on-pad configuration than for the load-between-pads configuration. Rotordynamic performance measurements during driving tests up to 100 krpm demonstrated synchronous vibrations and subsynchronous vibrations with large amplitudes. The test was repeated after inserting the shim between the top foil and beam foil to reduce the bearing radial clearance. The reduced bearing clearance resulted in a reduction in the peak amplitude of the synchronous vibrations and an increase in the speed at which the peak amplitude occurred. In addition, the onset speed and amplitude of the subsynchronous vibrations were dramatically increased and diminished, respectively. The rotor coast-down tests at 100 krpm show that the reduction in the bearing clearance extends the time to rotor stop, thus implying an improvement in hydrodynamic pressure generation and a reduction in bearing frictional torque.

Development of 1.2[kW]Class Fuel Cell Power Conversion System (1.2[kW]급 연료전지용 전력변환장치의 개발)

  • Suh, Ki-Young;Kim, Chil-Ryong;Cho, Man-Chul;Kim, Jung-Do;Yoon, Young-Byun;Kim, Hong-Sin;Park, Do-Hyung;Ha, Sung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.117-125
    • /
    • 2007
  • Recently, a fuel cell with low voltage and high current output characteristics is remarkable for new generation system. It needs both a DC-DC step-up converter and DC-AC inverter to be used in fuel cell generation system. Therefor, this paper, consists of an isolated DC-DC converter to boost the fuel cell voltage 380[VDC] and a PWM inverter with LC filter to convent the DC voltage to single-phase 220[VAC]. Expressly, The fuel cell system which it proposes DC-DC the efficient converter used PWM the phase transient control law and it depended to portion resonance ZVS switching, loss peek voltage and electric current of realization under make schedule, switching frequency anger and the switch reduction. And mind benevolence it sprouted 2 in stop circuit and it added and a direct current voltage and the electric current where the ingredient is reduced in load side ripple stable under make whom it will be able to supply. Besides the efficiency of 92[%]is obtained over the wide output voltage regulation ranges and load variations. Also, under make over together the result leads simulation and test, the propriety confirmation.

The Application of a Simplified Pullout Test for High-Strength Concrete (고강도 콘크리트에 대한 간이 인발시험법 적용)

  • Ko, Hune-Bum;Jeon, Doo-Jin;Lee, Min-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.49-55
    • /
    • 2017
  • In the seventies, a number of researchers carried out experiments on pullout tests with prototype equipment, and the pullout test was certified as a reliable nondestructive testing(NDT) method for determining the strength of concrete. To estimate the strength of high-strength concrete, we propose a simplified pullout test that uses as a break-off bolt a standard 10mm bolt with a groove on the shaft, an insert nut, and a pullout instrument that includes a hydraulic oil pump without a load cell. To verify the advantages of the simplified pullout test(low cost, simplicity, and convenience), four wall specimens were tested with two levels of concrete strength, 30 MPa and 50 MPa, using a simplified pullout tester with a load cell. The pullout load and concrete compressive strength were measured every day until day 7, day 14, day 21 and day 28. It was found that the pullout load was very similar to the compressive strength. Therefore, we have verified that a simplified pullout test can be used to evaluate the in-place strength of high-strength concrete in structures. The prediction equation of the groove diameter of the break-off bolt(y) with the concrete strength(x) was derived as y=0.05x+3.79, with a coefficient of determination of 0.88 found through regression analysis.