• Title/Summary/Keyword: LOAD CELL

Search Result 1,188, Processing Time 0.03 seconds

Capacity Enhancement of the Single Cell System through the Dual-hop Relay (단일 셀 기반 이중 도약 중계 시스템의 성능 향상을 위한 중계기 영역 연구)

  • Kim, Jae-Hwan;Kim, Hyoung-Jong;Song, Hyeong-Jun;Gwon, Tae-Hun;O, Eun-Seong;Hong, Dae-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.151-152
    • /
    • 2006
  • Multi-hop system has advantage of low power consumption, improved cell capacity, and enlarged service coverage. Most of previous researches show that multi-hop relaying beyond dual-hop relaying does not improve system performance significantly. This leads most researches are focused on dual-hop relaying system. In this paper, we propose an optimal boundary condition to support maximal data rate for fluctuation of traffic load in single cell dual-hop relay system.

  • PDF

Status Review of Power Electronic Converters for Fuel Cell Applications

  • Emadi, Ali;Williamson, Sheldon S.
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.133-144
    • /
    • 2001
  • Power electronics plays an important role in providing an interface between fuel cells and loads. Furthermore, power electronic converters ensure that the power is reliably and efficiently delivered to the load in the required DC or AC form. In this paper, major types of fuel cells are presented. Basic structures, operating principles, and different applications of fuel cells are described. In addition, current status and future trends in the areas of power electronics for fuel cells are described. In addition, current statue and future trends in the areas of power electronics for fuel cell applications are explained. A review of fuel cell power electronic system topologies and basic requirements are given as well.

  • PDF

Preparation and Characteristics of Pt/GDE Loaded with Pd Promoter for PEMFC (Pd 조촉매가 도입된 PEMFC용 Pt/GDE 제조 및 특성)

  • LEE, HONGKI;LEE, WOOKUM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.3
    • /
    • pp.264-269
    • /
    • 2016
  • A simple dry chemical approach was developed in order to load palladium (Pd) as a promoter on Pt/gas diffusion electrode (GDE) for polymer electrolyte membrane fuel cell (PEMFC). Palladium(II) bis (acetylacetonate), $Pd(acac)_2$ was sublimed, penetrated into Pt/GDE and then reduced to Pd nanoparticles simultaneously without any reducing agent and any solvent in a glass reactor of $N_2$ atmosphere at $180^{\circ}C$ for 3, 5 and 15 min. Pd distribution was analyzed by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS), and I-V curve was estimated by using a unit cell with $5{\times}5cm^2$ active area.

Distributed Resource Partitioning Scheme for Intercell Interference in Multicellular Networks

  • Song, Jae-Su;Lee, Seung-Hwan
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.1
    • /
    • pp.14-19
    • /
    • 2015
  • In multicellular wireless networks, intercell interference limits system performance, especially cell edge user performance. One promising approach to solve this problem is the intercell interference coordination (ICIC) scheme. In this paper, we propose a new ICIC scheme based on a resource partitioning approach to enhance cell edge user performance in a wireless multicellular system. The most important feature of the proposed scheme is that the algorithm is performed at each base station in a distributed manner and therefore minimizes the required information exchange between neighboring base stations. The proposed scheme has benefits in a practical environment where the traffic load distribution is not uniform among base stations and the backhaul capacity between the base stations is limited.

Development of Energy Control Simulation for Fuel Cell Hybrid System (연료전지 하이브리드 전력 시스템에 대한 에너지 제어 시뮬레이션)

  • Han, Soo-Bin;Song, Yu-Jin;Jeong, Bong-Man;Park, Seok-In;Jeong, Hak-Geun;Jang, Woo-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.355-358
    • /
    • 2005
  • This paper describes an simulation method to utilize the hybrid system with fuel cell and battery. The hybrid system has unique advantage to manage energy state between high energy system (fuel cell) and high power system (battery) according to various type of load. For proper design, the hybrid system is modelled and simulated. Especially, battery SOC is used as an important control parameter to decide the energy control.

  • PDF

Analyze of High Efficiency PCS for Fuel Cell (연료전지용 3-Stage PCS의 손실 해석)

  • Ba, Yasgalan;Lee, Yong-Jin;Han, Dong-Hwa;Kim, Young-Sik;Gwon, Wang-Song;Jeong, Beong-Hwang;Shin, Woo-Sok;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.100-102
    • /
    • 2008
  • As Utility interactive fuel cell systems are widely used, it is required for each power conditioning system(PCS) to have higher generating performance and more stable connecting characteristics. This study is focused to minimization of power losses and hence higher efficiency related to the new half bridge type 3-stage utility interactive PCS topology. The loss factor of half-bridge converter becomes only 1.2[%] under the rated load, and hence total efficiency is maintained to be higher as 91[%].

  • PDF

Prediction of Membrane Water Content Characteristics through Dynamic Nonlinear Model (비선형 동특성 모델을 통한 전해막 습증기 함유도 특성 예측)

  • LEE, CHANHEE;KIM, YOUNGHYEON;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.497-505
    • /
    • 2021
  • Water management is essential to improve the performance of proton exchange membrane fuel cells. This study targets to understand the characteristics of water concentration in proton exchange membrane fuel cells at a dynamic load variable environment. The fuel cell model was developed to simulate nonlinear water transport in membrane by the MATLAB/Simulink® (MathWorks, Natick, MA, USA) platform, and it calculates water content in membrane, ionic conductivity, and predicts fuel cell performance through one-dimensional analysis.

Study on Transient Response of a Unit Proton Exchange Membrane Fuel Cell with an Aged Gas Diffusion Layer (내구성능저하된 기체확산층이 고분자전해질 연료전지의 과도응답성능에 미치는 영향 연구)

  • Cho, Junhyun;Ha, Tahun;Park, Jaeman;Oh, Hwanyeong;Min, Kyoungdoug;Jyoung, Jy-Young;Lee, Eunsook
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.76.2-76.2
    • /
    • 2010
  • The gas diffusion layer is the key component of the proton exchange membrane fuel cell because it directly affect to the mass transport mechanism and dynamic behavior of the cell. In this study, the effects of GDL aging on the transient response of the PEM fuel cell is systematically investigated using current step transient response analysis under different stoichiometric ratios and humidity conditions. With GDLs aged by the accelerated stress test, the effects of hydrophobicity and structural changes due to carbon loss in the GDL on the transient response of PEM fuel cells are determined. The degraded GDLs that had uneven hydrophobicity distributions cause local water flooding inside the GDL and induce lower and unstable voltage responses after load changes.

  • PDF

Multilayered phospholipid polymer hydrogels for releasing cell growth factors

  • Choi, Jiyeon;Konno, Tomohiro;Ishihara, Kazuhiko
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.1 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • Polymer multilayered hydrogels were prepared on a titanium alloy (Ti) substrate using a layer-by-layer (LBL) process to load a cell growth factor. Two water-soluble polymers were used to fabricate the multilayered hydrogels, a phospholipid polymer with both N, N-dimethylaminoethyl methacrylate (DMAEMA) units and 4-vinylphenylboronic acid (VPBA) units [poly(MPC-co-DMAEMA-co-VPBA) (PMDV)], and the polysaccharide alginate (ALG). PMDV interacted with ALG through a selective reaction between the VPBA units in PMDV and the hydroxyl groups in ALG and through electrostatic interactions between the DMAEMA units in PMDA and the anionic carboxyl groups in ALG. First, the Ti substrate was covered with photoreactive poly vinyl alcohol, and then the Ti alloy was alternately immersed in the respective polymer solutions to form the PMDV/ALG multilayered hydrogels. In this multilayered hydrogel, vascular endothelial growth factor (VEGF) was introduced in different layers during the LbL process under mild conditions. Release of VEGF from the multilayered hydrogels was dependent on the location; however, release continued for 2 weeks. Endothelial cells adhered to the hydrogel and proliferated, and these corresponded to the VEGF release profile from the hydrogel. We concluded that multilayered hydrogels composed of PMDV and ALG could be loaded with cell growth factors that have high activity and can control cell functions. Therefore, this system provides a cell function controllable substrate based on the controlled release of biologically active proteins.

Power Control Based Call Admission Control Method of the CDMA PCS System

  • 이강원;국광호;최정락
    • Korean Management Science Review
    • /
    • v.16 no.1
    • /
    • pp.39-50
    • /
    • 1999
  • This paper proposes a new call admission control method to enhance the reverse link capacity of a cell with heavy traffic in the CDMA PCS system under the uneven traffic load between cells. Since the capacity of a cell in the CDMA system is restricted by the total interference caused by terminals in the own cell and the adjacent cells, we can enhance the capacity of a cell by reducing the interference from other cells if possible. Our power control method allows that the signal powers received in base stations with heavy traffic be larger than those received in base stations with light traffic in order to make the interference due to other cells in the cells with heavy traffic relatively small. In the previous study, it was assumed that the signal power received by each base station in the CDMA PCS system is same when the call admission control algorithm is implemented. We could show that the reverse link capacity of a cell in the CDMA PCS system can be increased about 20% under our call admission control method.

  • PDF