• Title/Summary/Keyword: LNG Station

Search Result 27, Processing Time 0.024 seconds

Economic Optimization Study for a $125,000m^3$ Class LNG Carrier

  • Lee, Kyu-Yeul;Lee, Dong-Kon;Jung, Ho-Hyun;Lee, Chul-Hee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.21 no.4
    • /
    • pp.1-9
    • /
    • 1984
  • This study is concerned with the economic aspects of $125,000m^3$ class LNG carriers with different propulsion plant such as conventional steam turbine and slow speed diesel engine with reliquefaction plant. The ship's speed and L/B ratio were optimized with criterion of required freight rate(RFR) by using the PROCAL computer program package. In order to investigate the effect of fuel oil price, round trip distance and boil-off rate on the RFR and the optimum speed, sensitivity analysis were also performed.

  • PDF

Flow Characteristics of Cryogenic Butterfly Valve for LNG Carrier (Part 2 : Flow Characteristics under Cryogenic Condition) (LNG선용 버터플라이밸브의 유동특성에 관한 연구 (제2부 : 극저온에서의 밸브 유동특성))

  • Kim, Sang-Wan;Choi, Young-Do;Kim, Bum-Suk;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.2
    • /
    • pp.20-28
    • /
    • 2008
  • Recently, butterfly valves are used as control valves for industrial process. However, there are not so many reports on cryogenic butterfly valves in spite of broad application in LNG storage station and LNG carriers. Present study is focused on the investigation of the detailed hydrodynamic and aerodynamic characteristics of cryogenic butterfly valves to contribute to the operation during the handling on LNG transportation system, and to the practical utilization in design of butterfly valves and actuators. The results show that large recirculation vortices in the region downstream of the valve are founded and the cavitation flows are intensively generated on the surface of valve disc at the relatively small opening angle. The aerodynamic characteristics, lift, drag and torque, acting on the valve disc are calculated. The pressure distribution and the pressure loss coefficient of the cryogenic butterfly valve show almost similar pattern with those of the butterfly valve which is used on the normal temperature.

Model development for site selection considering the characteristics of LNG receiving terminal (LNG 특성을 고려한 저장기지 입지선정 모델 개발)

  • Jeong, Nam Hoon;Liu, An Qi;Hwang, Geon Wook;Jang, Woosik;Han, Seung Heon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.82-91
    • /
    • 2015
  • Recently, due to the increasing concern of environmental factors and low carbon usage, the use of natural gas has been inclining steadily. In order to meet the growing demand of natural gas, government have established strategies to secure the sufficient amount of gas that is mainly used by industries, power generation and residential use by constructing additional receiving terminals for Liquid Natural Gas (LNG). In the process of selecting the optimal site for the terminals, the characteristics of the terminals are not considered where the decision making is done through internal meetings or outsourcing. In respect to site selection, researches are done to derive the factors that are considered for optimal site selection. However, there have not yet been researches in creating a systematic model for analyzing the optimal site selection. To this aim, the paper aims to propose a model for site selection of LNG receiving terminals that considers the characteristics of the terminal construction. Total of 47 factors considered in site selection is derived through interviews with experts and analyzing the previous cases of site selection by various firms. Furthermore, the derived 47 factors are used for the survey for the previous LNG terminals in PT, IC, TY, SC and BR areas where the survey data is analyzed by factor analysis and multiple regression models to depict the optimal site. By applying the model for site selection, practitioners are able to make decisions for site selection in a systematic approach for new candidates of sites.

Hydrogen Generation Technology for Hydrogen Fueling Station (수소스테이션용 고효율 수소제조 기술개발)

  • Oh, Young-Sam;Park, Dal-Lyung;Cho, Young-Ah
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.92-101
    • /
    • 2005
  • 세계적으로 수소에너지를 미래 에너지의 대안으로 여겨지고 있기 때문에 수소에너지 관련기술은 미래 국가 경쟁력을 좌우할 것으로 예상되고 있으며 수소에너지시대의 핵심인 수소스테이션 관련기술을 개발은 국가 연료전지 시장을 비롯한 수소 자동차 산업 전반에 큰 영향을 미칠 것으로 예상되고 있다. 이에 따라 전 세계적으로 수소에너지를 차세대 에너지원으로 개발하기 위하여 전력을 다하고 있으며 수소제조기술개발 및 수소스테이션 실증연구가 진행되고 있다. 본 연구에서는 수소제조장치 관련 국내외 기술개발 현황과 수소스테이션용 고효율 수소제조장치 장치 개발 현황을 소개하고자 한다.

  • PDF

A Study on the Emission Characteristics of LNG-diesel Dual-fuel Engine for Euro 2 Standard (Euro 2 기준 LNG-경유 혼소엔진의 배출가스 특성에 관한 연구)

  • Cho, Gyu-Baek;Kim, Chong-Min;Kim, Dong-Sik;Kim, Hong-Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2011
  • Heavy duty diesel engine has relatively small portion of whole vehicles due to long drive distance and large engine displacement, but largely influences atmosphere environment. City buses changed to CNG (Compressed Natural Gas) bus with Korea-Japan Worldcup. Heavy duty truck and intercity bus, however, were impossible to use CNG because those kinds of vehicles had long drive distance and CNG station was installed mainly at the around of the bus garage of city. Insulation container storing the natural gas as a liquid makes heavy duty truck and intercity bus possible to use the natural gas. Drive using diesel is possible where is hard to recharge the gas. With LNG (Liquefied Natural Gas), the dependence on oil is largely decreased, PM (Particulate Matter) and NOx which is chronic disadvantage of diesel is remarkably reduced and finally $CO_2$, the representative green house gas, is reduced over 10%.

A Study on the Reliability Analysis and Risk Assessment of Liquefied Natural Gas Supply Utilities (천연가스 공급설비에 대한 기기신뢰도 분석 및 위험성 평가)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.8-20
    • /
    • 2003
  • Natural gas has been supplied through underground pipelines and valve stations as a new city gas in Seoul. In contrast to its handiness the natural gas has very substantial hazards due to fires and explosions occurring from careless treatments or malfunctions of the transporting system. The main objectives of this study are to identify major hazards and to perform risk assessments after assessing reliabilities of the composing units in dealing with typical pipeline networks. there-fore two method, fault tree analysis ;1nd event tree analysis, are used here. Random valve stations are selected and considered its situation in location. The value of small leakage, large rupture, and no supply of liquefied natural gas is estimated as that of top event. By this calculation the values of small leakage are 3.29 in I)C valve station, 1.41 in DS valve station, those of large rup-lure are $1.90Times10_{-2}$ in DC valve station, $2.32$\times$10^{-2}$ in DS valve station, and those of no supply of LNG to civil gas company are $2.33$\times$10 ^{-2}$ , $2.89$\times$10^{-2}$ in each valve station. And through minimal cut set we can find the parts that is important and should be more important in overall system. In DC valve station one line must be added between basic event 26,27 because the potential hazard of these parts is the highest value. If it is added the failure rate of no supply of LNG is reduced to one fourth. In DS valve station the failure rate of basic event 4 is 92eye of no supply of LNG. Therefore if the portion of this part is reduced (one line added) the total failure rate can be decreased to one tenth. This analytical study on the risk assessment is very useful to prepare emergency actions or procedures in case of gas accidents around underground pipeline networks and to establish a resolute gas safety management system for loss prevention in Seoul metropolitan area.

Cu/ZnO sorbents for the hydrogen station (수소스테이션을 위한 Cu/ZnO 계 탈황제)

  • Jun, ki-Won;Bae, Jong-Wook;Kang, Suk-Hwan;Yoon, Young-Seek;Kim, Myung-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.344-347
    • /
    • 2006
  • 탄화수소 연료(LNG, LPG)를 개질하여 수소를 제조하는 연료 처리 공정 중, 탈황 기술은 촉매의 활성저하 및 전극의 피독을 방지하기 위한 필수 기술이다. 본 연구에서는 도시가스 및 액화석유 가스용 부취제로 사용되는 유기 황화합물(,DMS, THT, TBM)을 제거하기 위한 탈황제로서 Cu/ZnO계 흡착제를 개발하였다. 공침법을 이용하여 흡착제를 제조하여 각 부취제별로 상온 및 고온에서의 흡착탈황 성능을 조사하였으며 또한, 이의 특성분석을 행하였다. $Cu/ZnO/Al_2O_3$ 탈황제는 메탄으로부터 고온에서 TH, DMS, TBM+THT 등의 황화합물들을 매우 효과적으로 제거할 수 있었다. 특히, TBM+THT의 혼합가스에서 TBM에 대해 선택적인 흡착을 보였다. THT 흡착에서 흡착온도가 $300^{\circ}C$ 이상에서는, 흡착과정 동안 황의 상호작용으로 인해 금속황화물이 생성되었다.

  • PDF

A Study on the Visualization of Ice-formation Phenomena of Bath Water to Decide Maintenance Period of Gas Heater (가스히터 보수주기 결정을 위한 히터내부 열전달 매체액 결빙현상 가시화에 관한 연구)

  • Lee J. H.;Ha J. M.;Sung W. M.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.1-8
    • /
    • 2001
  • This study was carried out for the purpose of determination of maintenance period and investigation of weak point due to freeze when the gas heater of KOGAS valve station Is not operated in winter season. 3-dimensional non-linear numerical simulation was conducted in order to predict the time and location which bath water in heater reaches to ice point. FLUENT V 5.0, commercial code, is used for thermal fluid flow analysis. We thought this was problem of heat conduction solving the energy equation and modeled gas heater by using the real geometry and scale for performing the 3-dimensional simulation. It was analyzed complex heat transfer phenomena considering convection due to air on surface, conduction in insulation material, natural convection of liquid in heater and heat loss through the pipe.

  • PDF

Efficiency Analysis of Compact Type Steam Reformer (컴팩트형 수증기 개질장치 효율분석)

  • Oh, Young-Sam;Song, Taek-Yong;Baek, Young-Soon;Choi, Lee-Sang
    • Journal of Hydrogen and New Energy
    • /
    • v.13 no.4
    • /
    • pp.304-312
    • /
    • 2002
  • In this study, the performance of the $5Nm^3/hr$ compact type steam reformer which was developed for application of fuel cell or hydrogen station was evaluated in terms of gas process efficiency. For these purposes, reforming efficiency and total efficiency with system load change were analyzed. The reforming efficiency was calculated from the total molar flow of hydrogen output over total fuel flow input to the reformer and the burner on the higher heating value(HHV). In the case of the total efficiency, recovered heat at the heat recovery exchanger was considered. From the results, it was known that system performance was stable, because methane conversion showed the a slight decline which is about 2% though increasing system load to full. Reforming efficiency was increased from 20% to 58%, respectively as increasing system load from 10% to 90%. It was found that total efficiency was higher then reforming efficiency because of terms of heat recovered. As a results, it was known that total efficiency was increased form 75% to 83% at the 10% and 90% system load, respectively. From these results, it is concluded that compact steam reformer which is composed of stacking plate-type reactors is suitable to on-site hydrogen generator or to fuel cell application because of quick start within 1 hr and good performance.

Vertical Profiles and Assessment of Trace Metals in Sediment Cores From Outer Sea of Lake Shihwa, Korea (시화호 외측 해역 주상 퇴적물 내 미량금속 수직분포 특성 및 오염도 평가)

  • Ra, Kongtae;Kim, Joung-Keun;Kim, Eun-Soo;Kim, Kyung-Tae;Lee, Jung-Moo;Kim, Eu-Yeol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.2
    • /
    • pp.71-81
    • /
    • 2013
  • Trace metal concentration in sediment cores from the outer sea of Lake Shihwa were determined to study the vertical profiles of metal concentrations and to evaluate the levels of metal contamination. Sediment pollution assessment was carried out using enrichment factor (EF) and geo-accumulation index (Igeo). The mean concentration of metals were 58.8 mg/kg for Cr, 10.3 mg/kg for Co, 22.8 mg/kg for Ni, 18.1 mg/kg for Cu, 74.0 mg/kg for Zn, 6.75 mg/kg for As, 0.14 mg/kg for Cd, 27.4 mg/kg for Pb and 0.026 mg/kg for Hg, respectively. The mean EF values for Cu, Zn, As, Cd and Hg were greater than 1.5 in sediment cores, indicating that these metals in sediments are slightly enriched by anthropogenic activities. The geo-accumulation index (Igeo) suggested unpolluted status for metals of sediments collected from outer see of Lake Shihwa. Igeo values for Cu and Hg nearby LNG station (site C, D, E) ranged from 1 to 2, indicating moderately to unpolluted pollution status for those metals. Even if the higher concentrations of trace metals nearby LNG station were observed, there is significantly positive relationship between Al and trace metals. Thus, the sediment grain size plays an important roles in influencing the distribution of trace metals in sediment cores from the outer sea of Lake Shihwa. Based on the comparison with sediment quality guidelines such as threshold effect level and probable effect level in Korea, the concentration of metals in sediments from outer sea of Lake Shihwa are likely to result in no harmful effects on sediment-dwelling organisms.