• Title/Summary/Keyword: LLD

Search Result 50, Processing Time 0.024 seconds

Tritium( $^3$H) Activity Measurement by the Liquid Scintillation Counting Method

  • Hwang, Sun-Tae;Oh, Pil-Jae;Lee, Min-Kie;Kim, Wi-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.E
    • /
    • pp.299-302
    • /
    • 1994
  • At a nuclear power plant, environmental radioactivity monitoring is routine work for the radiation safety management For the environmental monitoring of tritium($^3$H) activity in water sampled liquid scintillation counting( LSC) method is applied to measure low- energy beta activity from tritium in the samples. The $^3$H activity is measured using the BECKMAN 5801 system at the KRISS( Korea Research Institute of Standards and Science) for evaluating the lower limits of detection( LLD) of $^3$H measurement and the measuring capability of low-level $^3$H activity at four nuclear Power Plant sites. The LSC systems used for low-level $^3$H activity measurements at the nuclear Power Plants are confirmed to satisfy throughout an intercomparison study under the experimental arrangements by the KRISS.

  • PDF

A Study of Optical Characteristics for Maintenance Factors on Roadway Lighting Design (도로조명 설계에서 보수율에 따른 광학적 특성 연구)

  • Hwang, Myung-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2153-2155
    • /
    • 2000
  • The not an organization a branch stream the maintenance factor class on a class and the roadway type for roadway lighting design, the facted an insufficiency maintenance factor to apply our the country conditions. The consideration of maintenance factors is not being fully applied for roadway lighting design in Korea. This paper consider optical characteristics and maintenance factors as well as LID of Luminaires in designing roadway lighting. Consideration of maintenance factors that are neme specified according to LDD(Luminaire Dirt Depreciation), LLD(Lamp Lumen Depreciation), AADT(Average Annual Daily Traffic) based on IESNA regulation. The analyzed optical characteristics are applied for stagger and cross roadway types with maintenance factors in the range of 0.51$\sim$1.00 and equipment factor of 0.9.

  • PDF

An Improved Location Data Management Scheme for GALIS Prototype (GALIS 프로토타입을 위한 위치 데이타 관리 기법)

  • Lee, Ho;Lee, Joon-Woo;Nah, Yun-Mook
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.211-213
    • /
    • 2005
  • 최근의 위치 측위 기술과 무선 통신 기술의 발전에 따라 위치 기반 서비스에 대한 관심이 크게 증가하고 있다. 기존의 단일 노드 기반 시스템으로는 처리하기 힘든 휴대폰 사용자와 같은 대용량의 객체를 처리하기 위해 제시된 클러스터 기반 분산 컴퓨팅 구조로 GALIS 아키텍처가 제안되었다. 본 논문에서는 제시한 프로토타입은 그동안 구현된 기존 GALIS 프로토타입보다 개선된 구조로 SLDS에서 Global $Cell\_ID$를 적용하여 노드의 분할 합병 시 발생할 수 있는 처리 비용을 감소시켰다. 또한 LLDS에서는 필터링을 통해 손실들 수 있는 위치 데이타 정보를 보다 신뢰할 수 있는 데이타로 만들기 위한 기능을 추가하여 질의 시 발생할 수 있는 여러 가지 상황을 대비할 수 있게 되었다.

  • PDF

Freshness Comparison of Lettuce (Lactuca sativa L.) in accordance with Storage and Packaging Method on High-temperature Period (결구상추 고온기 포장 및 저장방법에 따른 신선도 비교)

  • Bark, Doe-Ey;Yoon, Yi-Na;Woo, Ye Jinn;Cheung, Gum Hang;Hwang, Sae Bom;Park, SuHyoung;Woo, Young-June;Shin, Chul;Choi, Dong-soo;Lim, Junhyung;Park, See Eun;Lee, Jung-Soo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.21 no.1
    • /
    • pp.35-40
    • /
    • 2015
  • Effect of packaging and storage methods for enhancing the shelf life and improving the postharvest quality of lettuce (Lactuca sativa L.) was studied during high temperature period. Lettuces were packed using four packaging and storage types: (A) plastic box container (control); (B) plastic box container covered with high density polyethylene (HDPE) film; (C) plastic box container with lettuce wrapped in linear low-density polyethylene (LLD-PE) film; and (D) plastic box container with lettuce with its stem. The quality parameters, such as fresh weight loss, SPAD value, and appearance of lettuce were investigated. The lettuce wrapped with LLD-PE film inside the plastic box container showed the lowest weight loss, highest SPAD value and best appearance compared to those exposed to the other packaging and storage methods during the three-week storage at $2^{\circ}C$. The results indicate that the marketability of lettuce can be optimized if proper packaging and storing is adopted. Prolonging the freshness even on low temperature storage will increase the potential of its sale ability in the domestic market even during summer season.

  • PDF

Real-Time Monitoring and Buffering Strategy of Moving Object Databases on Cluster-based Distributed Computing Architecture (클러스터 기반 분산 컴퓨팅 구조에서의 이동 객체 데이타베이스의 실시간 모니터링과 버퍼링 기법)

  • Kim, Sang-Woo;Jeon, Se-Gil;Park, Seung-Yong;Lee, Chung-Woo;Hwang, Jae-Il;Nah, Yun-Mook
    • Journal of Korea Spatial Information System Society
    • /
    • v.8 no.2 s.17
    • /
    • pp.75-89
    • /
    • 2006
  • LBS (Location-Based Service) systems have become a serious subject for research and development since recent rapid advances in wireless communication technologies and position measurement technologies such as global positioning system. The architecture named the GALIS (Gracefully Aging Location Information System) has been suggested which is a cluster-based distributed computing system architecture to overcome performance losses and to efficiently handle a large volume of data, at least millions. The GALIS consists of SLDS and LLDS. The SLDS manages current location information of moving objects and the LLDS manages past location information of moving objects. In this thesis, we implement a monitoring technique for the GALIS prototype, to allow dynamic load balancing among multiple computing nodes by keeping track of the load of each node in real-time during the location data management and spatio-temporal query processing. We also propose a buffering technique which efficiently manages the query results having overlapped query regions to improve query processing performance of the GALIS. The proposed scheme reduces query processing time by eliminating unnecessary query execution on the overlapped regions with the previous queries.

  • PDF

Pretreatment Process for Performance Improvement of SIES at Kori Unit 2 in Korea

  • Lee, Sang-Jin;Yang, Ho-Yeon;Shin, Sang-Woon;Song, Myung-Jae
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.12-27
    • /
    • 2004
  • Pretreatment process consisted of submerged hollow-fiber microfiltration(HMF) membrane and spiral-wound nanofiltration(SNF) membrane has been developed by NETEC, KHNP for the purpose of improving the impurities of liquid radioactive waste before entering Selective Ion Exchange System(SIES). The lab-scale combined system was installed at Kori NPP #2 nuclear power plant and demonstration tests using actual liquid radioactive waste were carried out to verify the performance of the combined system. The submerged HMF membrane was adopted for removal of suspended solid in liquid radioactive waste and the SNF membrane was used for removal of particulate radioisotope such as, Ag-l10m and oily waste because ion exchange resin can not remove particulate radioisotopes. The liquid waste in Waste Holdup Tank (WHT) was processed with HMF and SNF membrane, and SIES. The initial SS concentration and total activity of actual waste were 38,000ppb and $1.534{\times}10_{-3}{\mu}Ci/cc$, respectively. The SS concentration and total activity of permeate were 30ppb and lower than LLD(Lower Limit of Detection), respectively.

  • PDF

Specimen Thickness and Crack Depth Effects on J Testing and Crack Tip Constraint for Non-standard Specimen (시편두께 및 균열깊이 영향을 고려한 비표준시편의 J 시험법 및 구속효과의 정량화)

  • Kim, Jin-Su;Cho, Soo-Man;Kim, Yun-Jae;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1531-1538
    • /
    • 2003
  • This paper compiles solutions of plastic $\eta$ factors and crack tip stress triaxialites for standard and nonstandard fracture toughness testing specimens, via detailed three-dimensional (3-D) finite element (FE) analyses. Fracture toughness testing specimens include a middle cracked tension (M(T)) specimen, SE(B), single-edge cracked bar in tension (SE(T)) and C(T) specimen. The ligament-to-thickness ratio of the specimen is systematically varied. It is found that the use of the CMOD overall provides more robust experimental J estimation than that of the LLD, for all cases considered in the present work. Moreover, the J estimation based on the load-CMOD record is shown to be insensitive to the specimen thickness, and thus can be used for testing specimen with any thickness. The effects of in-plane and out-of-plane constraint on the crack tip stress triaxiality are also quantified, so that when experimental J value is estimated according to the procedure recommended in this paper, the corresponding crack tip stress triaxiality can be estimated. Moreover, it is found that the out-of-plane constraint effect is related to the in-plane constraint effect.

A Study on the Improvement Plan of Publishing in Library Linked Open Data (국내 도서관 링크드 오픈 데이터 구축과 발행의 개선방안 연구)

  • Lee, Sung-Sook
    • Journal of the Korean Society for information Management
    • /
    • v.37 no.2
    • /
    • pp.145-169
    • /
    • 2020
  • The purpose of this study is to find the cause and solution of the situation where library LOD does not spread after the introduction of library LOD. Research methods include literature research, case studies, and expert interviews. The improvement plan presented in this study is that first, the library needs to avoid the redundancy of the LOD construction target and build the only and specialized data. Second, libraries need to develop LOD services that reflect user needs and implement convenient LOD interfaces. Third, libraries need to establish identification system of data and build a authority file. Fourth, libraries need to recognize the necessity of data opening and linking to librarians and users, and provide opportunities for education and publicity. Fifth, it is necessary to use LOD for integrated search and to establish an integrated platform for search of library LOD. Sixth, libraries need to strengthen cooperation for LOD issuance and utilization, and form a working-level consultative body. Seventh, the government should pursue strong policies with a continuous commitment to LOD promotion and need to continue to provide budget support.

Effects of Gait Training Using Functional Electrical Stimulation on Stroke Patients' Balance and Gait Velocity

  • Kang, Kwon-Young;Choi, Wan-Suk;An, Ho-Jung;Koo, Ja-Pung;Lee, Joon-Hee;Yun, Young-Dae;Lee, Jung-Sook;Jung, Joung-Youl;Lee, Sang-Bin
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.2 no.2
    • /
    • pp.288-293
    • /
    • 2011
  • The purpose of this study is to examine the effects of gait training using functional electrical stimulation on the improvement of hemiplegic patients' functions for balance and gait velocity. The subjects of the experiment were determined to be 10 each hemiplegic patients who had been diagnosed with stroke or brain damage six months or longer earlier assigned to an experimental group and a control group respectively. The subjects were evaluated before the experiment using Tetrax and 10M gait tests, received gait training five times a week for four weeks using functional electrical stimulation and were evaluated after the experiment in the same method as used in the evaluation before the experiment. In order to examine differences between the experimental group that received gait training using functional electrical stimulation and the control group that was treated by functional electrical stimulation and received gait training thereafter, differences between before and after the experiment were analyzed using paired sample t-tests and differences in changes after the experiment between the experimental group and the control group were analyzed using independent sample t-tests in order to compare the two groups with each other. Experimental results showed significant differences in weight bearing, balance and gait velocity between before and after the experiment in the experimental group(p<.05). In the control group, whereas weight bearing and gait velocity did not show any significant difference between before and after the experiment(p>.05), balance showed significant differences(p<.05). Weight bearing, balance and gait velocity change rates showed significant differences between the experimental group and the control group(p<.05). In conclusion, it was indicated that gait training using functional electrical stimulation is effective for enhancing stroke patients' weight bearing rates, balance abilities and gait velocity.

A Study on the Characteristics of Lower Extremity Weight Bearing in Patients with Low Back Pain (요통환자의 기립시 하지체중 지지특성에 관한 연구)

  • Yoon, Hong-Il;Bae, Soo-Chan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.5 no.1
    • /
    • pp.59-74
    • /
    • 1999
  • 66 patients with low back pain were evaluated to determine if any differences of weight bearing were existed between the same side leg that feel pain(pain side leg) and that without pain (non-pain side leg) of lower extremities while weight bearing. 66 patients were divided into 3 groups according to pain pattern such as low back pain only(26), radiating pain only(21) and low back pain with radiating pain (19). Control group were 28 normal persons. The weight bearing was rated by Limloader(Model LLD-2000, Ver 1.2) and analyzed by paired and independent t-test, one-way ANOVA, Dunan's analaysis and Pearson's correlation analysis. The results of this study were as follows : 1. In patient group, significant difference of weight bearing rating between pain side leg and non-pain side leg was found. There was borne significantly less weight bearing rating(14.68%) on the pain side leg(P<.001). 2. In normal group, there was no significant difference between left and right leg(P>.05). But there was significant difference(3.21%) in absolute difference of both leg(p<.001). 3. The difference of 1 and 2 was 11.47% : more difference of weight bearing rating between both legs in patient group than that of the control group(p<.001). 4. There were significant differences of weight bearing rating in those 3 groups : low back pain group(10.30%), radiating pain group (17.90%) and low back pain with radiating pain group (17.10%) (p<.001). 5. There was significant correlation between pain intensity and difference of weight bearing rating(p<.05). The severer pain intensity. the more difference of weight bearing rating was found. 6. There was no significant correlation between the age, height and duration of symptom, etc(p>.05).

  • PDF