• Title/Summary/Keyword: LINE-1

Search Result 16,771, Processing Time 0.039 seconds

Visual Acuity of Fish - 1 . Relationship Between line Width and Distance at Visual Limit of Filefish Stephanolepis Cirrhifer - (어류의 시각에 관한 연구 - 1 . 쥐치의 시인한계에서의 선의 굵기와 거리와의 관계 -)

  • An, Young-Il;Yang, Yong-Rhim
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.3
    • /
    • pp.241-248
    • /
    • 1996
  • The relationship between width of line target and distance at the limit of discrimination was examined by means of the behavioral method, for filefish Stephanolepis cirrhifer from 11 to 15cm body length. Target distance was distance from beginning of partition board to target plate, and was varied from 50cm to 200cm. The target plate was made of white acrylic resin with a vertical black line in the center. The width of line target was varied from 0.2mm to 8.0mm. Fish were trained to respond to a line target and the width of line target reduced until the minimum width required to elicit a response was established. Rate of success was expressed as the percentage of target choices in 90 trials. The line acuity of filefish was found to be 0.58 at a target distance of 50cm. The rate of success decreased slowly as line target width decreased from 8.0mm to 1.5mm, and decreased suddenly for target widths less than about 1.5mm. The width of the line target D(mm) at the limit of discrimination was shown to be an exponential function of the target distance L(cm) as follows : D=exp(9.947$\times$$10^-3$.L+0.146)

  • PDF

Design of the menu on a multi-line display (Multi-line Display를 이용하는 제품의 메뉴 설계방안)

  • 유승무;한성호;곽지영
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.1-14
    • /
    • 1996
  • Menu-driven interfaces are frequently employed for user interfaces on many electronic products. Due to space constraint, a single or multi-line display is popularly used to show menu items unlike the software interfaces. Single or multi-line display present 8 .approx. 21. characters on an LCD screen and the user selects items using a series of button pushes. Multi-line displays are different from the single-line ones in the following aspects. First, they can present multiple line of information at the same time. Second, they can present menu items in a various way compared to single-line ones. However, due to their space constraint multi-line displays have many limitations compared to ordinary displays which usually use 14" screens. Therefore, guidelines are necessary for designing efficent multi-line display menus interfaces. In this study, a human factors experiment was conducted to examine the effects of three design variables which might affect the usability of a multi-line display menus. Factors investigated include menu structure, number of lines on the display, and item presentation method. Usability of the multi-line display menus was measured quantitatively in terms of four different aspects: speed, accuracy, inefficiency and preference. The analysis of variance was used not only to analyze the main effects of the factors and their interactions but also to see the differences between the single-line display menus and multi-line display ones. A set of design guidelines drawn from this study can be applied to the design of the user interfaces of a various types of electronic consumer products.

  • PDF

Gysel 3:1 variable power divider using the dual characteristic impedance transmission line (이중 특성 임피던스 선로를 이용한 Gysel 3:1 가변 전력분배기)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.10
    • /
    • pp.1409-1415
    • /
    • 2021
  • The Gysel divider has the advantage of easily setting the resistor in the circuit. If the line impedance in the Gysel divider is set differently, the input signal can be distributed to the two output ports at various distribution ratios. This paper proposes the Gysel divider that can change the power distribution to 1:3 or 3:1 by changing the line impedance. The impedance change of the line can be implemented by placing a floating copper plate on the bottom of the microstrip-line. When the floating copper plate and the ground plane are connected, the line operates as the microstrip-line, and when the floating copper plate and the ground plane are disconnected, the line operates as the coplanar-line. The proposed Gysel divider was fabricated at the center frequency of 1.5GHz. The fabricated 3:1 Gysel divider has a stable value S11 of below -17dB, S21/S31 of 4.8±0.2dB, S21(to high output port) of -1.39±0.12dB and S31(to low output port) of -6.15±0.08dB over 1.3~1.7GHz.

A Study on One-Piece Dress Pattern According to the Somatotype Alteration of Women in their 20s (20대 여성의 체형변화에 따른 원피스 드레스 원형연구)

  • Park, Ju-Hee;Hong, Jung-Min;Yoon, Jin-Kyung
    • Fashion & Textile Research Journal
    • /
    • v.7 no.4
    • /
    • pp.407-412
    • /
    • 2005
  • This study is to establish the pattern for one piece dress which fits well to the women somatotype with different drop value and is functional and has high body fitness. Selected 2 testers from classified 4 types who were close to the average value and took twice dressing test. After successive correction and revision, patterns of one piece dress for each somatotype were established. M type ; Bust line is established to B/4+1.7 cm. Waist line is W/4+1.5+2.5 cm(dart amount) for front pattern and W/4+0.8+2 cm(dart amount) for back. Hip line is H/4+0.8 cm for front and H/4+0.8 cm for back and the bust dart amount is 2.5 cm. A type ; Bust line is established to B/4+1.7 cm. Waist line is W/4+1.5+2.5 cm (dart amount) for front pattern and W/4+0.8+2 cm(dart amount) for back. Hip line is H/4+1.5 cm for front and H/4+1 cm for back and the bust dart amount is 2.2 cm. X type ; Bust line is established to B/4+1.5 cm for front pattern and B/4+2 cm for back. Waist line is W/4+2+2.5 cm (dart amount) for front and W/4+1+2+1.4 cm(for two darts amount) for back. Hip line is H/4+1 cm for front and H/4+1.3cm for back and the bust dart amount is 2.8 cm. H type; Bust line is established to B/4+1.5 cm for front pattern and B/4+2cm for back. Waist line is W/4+1.7+2.5 cm (dart amount) for front and W/4+0.8+2 cm(dart amount) for back. Hip line is H/4+2 cm for front and H/4+1.5 cm for back and the bust dart amount is 2.8 cm. In order to achieve the objective evaluation on a new pattern in this study, the sensory evaluation for both Imwonja pattern and a new pattern in this study was completed. As a result of sensory evaluation, a new pattern of this study could accomplished a good appearance in reflecting characteristics of each types and could achieved the functional superiority than comparison pattern.

Oxidative Stress Induces Hypomethylation of LINE-1 and Hypermethylation of the RUNX3 Promoter in a Bladder Cancer Cell Line

  • Wongpaiboonwattana, Wikrom;Tosukhowong, Piyaratana;Dissayabutra, Thasinas;Mutirangura, Apiwat;Boonla, Chanchai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3773-3778
    • /
    • 2013
  • Increased oxidative stress and changes in DNA methylation are frequently detected in bladder cancer patients. We previously demonstrated a relationship between increased oxidative stress and hypomethylation of the transposable long-interspersed nuclear element-1 (LINE-1). Promoter hypermethylation of a tumor suppressor gene, runt-related transcription factor 3 (RUNX3), may also be associated with bladder cancer genesis. In this study, we investigated changes of DNA methylation in LINE-1 and RUNX3 promoter in a bladder cancer cell (UM-UC-3) under oxidative stress conditions, stimulated by challenge with $H_2O_2$ for 72 h. Cells were pretreated with an antioxidant, tocopheryl acetate for 1 h to attenuate oxidative stress. Methylation levels of LINE-1 and RUNX3 promoter were measured by combined bisulfite restriction analysis PCR and methylation-specific PCR, respectively. Levels of LINE-1 methylation were significantly decreased in $H_2O_2$-treated cells, and reestablished after pretreated with tocopheryl acetate. Methylation of RUNX3 promoter was significantly increased in cells exposed to $H_2O_2$. In tocopheryl acetate pretreated cells, it was markedly decreased. In conclusion, hypomethylation of LINE-1 and hypermethylation of RUNX3 promoter in bladder cancer cell line was experimentally induced by reactive oxygen species (ROS). The present findings support the hypothesis that oxidative stress promotes urothelial cell carcinogenesis through modulation of DNA methylation. Our data also imply that mechanistic pathways of ROS-induced alteration of DNA methylation in a repetitive DNA element and a gene promoter might differ.

SLAM with Visually Salient Line Features in Indoor Hallway Environments (실내 복도 환경에서 선분 특징점을 이용한 비전 기반의 지도 작성 및 위치 인식)

  • An, Su-Yong;Kang, Jeong-Gwan;Lee, Lae-Kyeong;Oh, Se-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.40-47
    • /
    • 2010
  • This paper presents a simultaneous localization and mapping (SLAM) of an indoor hallway environment using Rao-Blackwellized particle filter (RBPF) along with a line segment as a landmark. Based on the fact that fluent line features can be extracted around the ceiling and side walls of hallway using vision sensor, a horizontal line segment is extracted from an edge image using Hough transform and is also tracked continuously by an optical flow method. A successive observation of a line segment gives initial state of the line in 3D space. For data association, registered feature and observed feature are matched in image space through a degree of overlap, an orientation of line, and a distance between two lines. Experiments show that a compact environmental map can be constructed with small number of horizontal line features in real-time.

Experimental Investigation of Differential Line Inductor for RF Circuits with Differential Structure

  • Park, Chang-kun
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.1
    • /
    • pp.11-15
    • /
    • 2011
  • A Differential line inductor is proposed for a differential power amplifier. The proposed differential line inductor is composed of two conventional line inductors rearranged to make the current direction of the two line inductors identical. The proposed line inductor is simulated with a 2.5-D and a 3-D EM simulator to verify its feasibility with the substrate information in a 0.18-${\mu}m$ RF CMOS process. The inductances of various line inductors implemented with printed circuit boards were measured. The feasibility of the proposed line inductor was successfully demonstrated.

Analysis and Experiment of Micro-strip Line Lumped Elements for SAW Duplexers (탄성표면파 듀플렉서용 마이크로 스트립라인 집중소자 해석 및 실험)

  • 이승희;노용래
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.1
    • /
    • pp.85-92
    • /
    • 2002
  • In this study, we analyzed and experimented micro-strip line inductors and capacitors for a SAW duplexer, an important devise for mobile communication. For SAW duplexers, micro-strip line lumped elements must have small impedance values, below several tens of nH or several tens of pF, and a small area pattern. In this study, we performed theoretical analysis of flat line type, meander line type, and spiral line type inductors and interdigital capacitors on a LiTaO$_3$ Piezo-crystal. We proposed a measurement method to evaluate small values of lumped elements accurately with network analyzer. In experiments, we confirmed validity of the theoretical analysis method through fabrication and characterization of micro-strip line lumped elements. The analysis method in this paper can be applied to SAW duplexers well as other microwave devices.

A Study on the Radiosensitivity and Chemosensitivity of YAC-1 Cell Line in Vitro (시험관내 YAC-1 세포주의 방사선 및 항암제감수성에 관한 연구)

  • Choi Eui-Hwan;Koh Kwang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.43-53
    • /
    • 1997
  • The purpose of this study was to aid in the prediction of tumor cell tolerance to radiotherapy and/or chemotherapy. For this study, cell surviving curves were obtained for mouse lymphoma YAC-1 cell line using semi automated MTT assay. 2, 4,6, 8, 10Gy were irradiated at a dose rate of 210cGy/rnin using /sup 60/Co Irradiator ALDORADO 8. After irradiation, YAC-1 cell lines(3×10⁴cells/ml) were exposed to bleomycin or cisplatin for 1 hour. The viable cells were determined for each radiation dose and/or each concentration of drug at the 4th day. And they were compared to control values. The obtained results were as follows : 1. The surviving curve with gentle slope was obtained after irradiation of 2, 4, 6, 8, 10 Gy on YAC-1 cell line. 2. The cytotoxicity of bleomycin or cisplatin was increased significantly at all concentration of 0.2㎍/ml, 2㎍/ml and 20㎍/ml on YAC-1 cell line (P<0.01). And the cytotoxicity of cisplatin was greater than that of bleomycin at all concentration on YAC-1 cell line (P<0.01). 3. There were no significant differences of surviving fractions among 4Gy, 6Gy and 8Gy after irradiation of each radiation dose with 2㎍/ml of bleomycin compared with irradiation only on YAC-1 cell line. 4. There was significant difference of surviving fraction between 2Gy and 10Gy after irradiation of each radiation dose with 2㎍/ml of cisplatin compared with irradiation only on YAC-1 cell line(P<0.05). 5. There were significant differences of surviving fractions between the groups of irradiation only and the groups of irradiation with 2㎍/ml of bleomycin or cisplatin at all doses of 2, 4, 6, 8 and 10Gy on YAC-1 cell line(P<0.05).

  • PDF

The fabrication of a coaxial line impedance transformer with low transmission loss and wideband operation range (저손실 광대역 동작 특성을 가지는 동축 선로 임피던스 변환기 제작)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2241-2248
    • /
    • 2017
  • The coaxial line impedance transformer that performs impedance conversion using the coupling of two or more coaxial lines of the same length is often used for impedance matching in the low frequency region due to many advantages. This paper measures the phase and magnitude characteristics of each coaxial line in a 4:1 coaxial line impedance transformer using two 100mm coaxial lines. This experiment shows that it is more effective to make the length of the auxiliary coaxial line shorter than the main coaxial line by about 5 mm in order to realize a low loss impedance transformer. In addition, it measures the transmission characteristics by directly connecting a 4:1 impedance transformer and a 1:4 impedance transformer. This experiment shows that it is effective to connect a 1pF capacitor between the ground and the outer conductor input point of the main coaxial line in order to increase the operating frequency range.