• Title/Summary/Keyword: LINAC-Based Radiosurgery

Search Result 36, Processing Time 0.024 seconds

Radiochromic film dosimetry for linac-based stereotactic radiosurgery

  • Han, Seung-Hee;Park, Suk-Won;Oh, Do-Hoon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.302-304
    • /
    • 2002
  • In linac-based stereotactic radiosurgery, assuring the quality of the planning and delivery of external photon beam requires accurate evaluation of beam parameters, usually including output factors, tissue-phantom ratio and off-axis ratios, and measurement of actual dose distributions from simulated treatment. We're going to test the use of calibrated radio chromic film (Gafchromic film; type MD-55, Nuclear associate) using a Lumiscan 75 digitizer to measure absolute dose and relative dose distributions for linac-based radiosurgery unit Relative dose distribution of a human-style spherical acryl phantom were measured using radiochromic film and calculated by treatment planning system. The absolute dose at the sphere center was measured by radiochromic film and micro chamber (Exradin A-14, 0.009cc). What we want to demonstrate in this work, the 'well selected' radiochromic films when external photon beam are used in linac-based stereotactic radiosurgery are very accurate detector for dosimetry.

  • PDF

New Techniques for Optimal Treatment Planning for LINAC-based Stereotactic Radiosurgery (LINAC 뇌정의적 방사선 수술시 새로운 최적 선량분포계획 시스템의 개발)

  • Suh Tae-suk
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.95-100
    • /
    • 1992
  • Since LINAC-based stereotactic radiosurgery uses multiple noncoplanar arcs, three-dimensional dose evaluation and many beam parameters, a lengthy computation time is required to optimize even the simplest case by a trial and error. The basic approach presented in this paper is to show promising methods using an experimental optimization and an analytic optimization The purpose of this paper is not to describe the detailed methods, but introduce briefly, proceeding research done currently or in near future. A more detailed description will be shown in ongoing published papers. Experimental optimization is based on two approaches. One is shaping the target volumes through the use of multiple isocenters determined from dose experience and testing. The other method is conformal therapy using a beam's eye view technique and field shaping. The analytic approach is to adapt computer-aided design optimization in finding optimum irradiation parameters automatically.

  • PDF

Dose Characteristics of Stereotatic Radiosurgery CONE used for ML-6M Linear Accelerator (ML-6M LINAC에 장착한 Radiosurgery Cone의 Beam 특성에 대한 고찰)

  • Moon, Un-Chull;Kim, Hyun-Jin;Kim, Young-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.15-31
    • /
    • 1995
  • The radiosurgery treatment is one time, non surgical approach to the treatment of patients with intracranial disorders whose conditions would be difficult or dangerous to treat with conventional sugical procedures. The LINAC based radiosurgery is based on the combination of multiple isocentric arc irradiation with small fields centered in the stereotactic target. The absorption of the beam in a tissue equivalent medium, such as water, as well as the uniformity, or profile, of the beam must be precisely documented. The beam characteristics and dosimetric measurememts of the 6MV X-ray beam from a ML-6M linear accelerator are examined. The percent depth dose (PDD) and beam profile (including flatness, symmetry and penumbra) is calibrated with the radiosurgery cone in water phantom. The cone is made of lead which size is from $10{\times}10mm{\phi}$ to $30{\times}30mm{\phi}$ All of these dosimetric measurements sufficiently characterized the beam to permit safe clinical use.

  • PDF

Three-Dimensional Dose Distribution for the System of Linear Accelerator-based Stereotactic Radiosurgery (LINAC을 이용한 뇌정위적 방사선 수술에 대한 3 차원 선량분포)

  • Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.121-128
    • /
    • 1991
  • Radiosurgery treatment in the brain requires detailed information on three-dimensional dose distribution. A three-dimensional treatment planning is a prerequisite for treatment plan optimization. It must cover 3-D methods for representing the patient, the dose distributions, and beam settings. Three-dimensional dose models for non-coplanar moving arcs were developed using measured single beam data and efficient 3-D dose algorithms for circular fields. The implementation of three dimensional dose algorithms with stereotactic radiosurgery and the application of the algorithms to several cases are discussed.

  • PDF

Linac Based Radiosurgery for Cerebral Arteriovenous Malformations (선형가속기 방사선 수술을 이용한 뇌동정맥기형의 치료)

  • Lee, Sung Yeal;Son, Eun Ik;Kim, Ok Bae;Choi, Tae Jin;Kim, Dong Won;Yim, Man Bin;Kim, In Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1030-1036
    • /
    • 2000
  • Objective : The aim of this study was to retrospectively analyze the safety and effect of Linac based Photon Knife Radiosugery System(PKRS) for treatment of cerebral arteriovenous malformation. Patients and Methods : The authors analyzed the clinical method and results of ten patients who were followed up more than two years, among the 18 patients who had radiosurgery on arteriovenous malformation from June, 1992, to Dec. 1997, with Linac based Photon knife radiosurgery system(PKRS) which was developed in our hospital. Results : The average age of the patients was 30.4(with the range of 13-49), and the sex was seven males and three females. For the initial clinical symptoms, there were five patients with headache, three with seizure, one with hemiparesis, and one with vomiting. Before the radiosurgery, computed tomography, MRI, and cerebral angiogram were done. For the location of arteriovenous malformation, it was found on six patients of cerebral hemisphere, two of thalamus, one of brainstem, and one of corpus callosum. Regarding the size of nidus, there were seven patients of smaller than 3cm, and three patients of larger than 3cm. Computed tomography, MRI, and cerebral angiogram were done periodically for sixth months, first year, and second year after the radiosurgery of PKRS for the completeness of obliteration. Six cases showed complete obliteration, and four partial obliterations were observed among ten cases, and interestingly, six cases of complete obliteration were observed among seven cases of small AVM of smaller than 3cm(the rate of complete obliteration : 85.7%). All patients tolerated the treatment and no significant complication were seen. Conclusion : In this study, linac based radiosurgery using PKRS onto arteriovenous malformation showed excellent effects, therefore authors believe that it is an ideal method for small sized or deep seated AVM.

  • PDF

Optimization of Dose Distribution for LINAC-based Radiosurgery with Multiple Isocenters (LINAC 뇌정위적 방사선 수술시 Multiple Isocenters를 이용한 최적 선량분포 계획)

  • Suh Tae-Suk;Yoon Sei Chul;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.351-359
    • /
    • 1991
  • The current LINAC technique for radiosurgery utilizes a single isocenter approach with multiple noncoplanar arcs. This approach results in spherical dose distributions in the target. Many arteriovenous malformations and tumors suitable for radiosurgical treatment have non-spherical or irregular shapes. The basic approach presented in this paper is to use two or multiple isocenters with standard arcs to shape irregular target volumes through the use of multiple spherical targets. Selection of reasonable irradiation parameters in the first stage is critical to the success of real-time optimization. A useful guideline for optimum isocenter separation and collimator size is developed to shape the target margin uniformly with an desired isodose surface for an elongated target. The implementation of multiple isocenters with three dimensional dose model and application of multiple isocenters approach to several cases are discussed.

  • PDF

Development of 3-D Radiosurgery Planning System Using IBM Personal Computer (IBM Personal Computer를 이용한 3차원적 뇌정위 방사선 수술계획 시스템의 개발)

  • Suh Tae-Suk;Suh Doug-Young;Park Charn Il;Ha Sung Whan;Kang Wee Saing;Park Sung Hun;Yoon Sei Chul
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.167-174
    • /
    • 1993
  • Recently, stereotactic radiosurgery plan is required with the information of 3-D image and dose distribution. A project has been doing if developing LINAC based stereotactic radiosurgery since April 1991. The purpose of this research is to develop 3-D radiosurgery planning system using personal computer. The procedure of this research is based on two steps. The first step is to develop 3-D localization system, which input the image information of the patient, coordinate transformation, the position and shape of target, and patient contour into computer system using CT image and stereotactic frame. The second step is to develop 3-D dose planning system, which compute dose distribution on image plane, display on high resolution monitor both isodose distribution and patient image simultaneously and develop menu-driven planning system. This prototype of radiosurgery planning system was applied recently for several clinical cases. It was shown that our planning system is fast, accurate and efficient while making it possible to handle various kinds of image modalities such as angiography, CT and MRI. It makes it possible to develop general 3-D planning system using beam's eye view or CT simulation in radiation therapy in future.

  • PDF

Outcomes for Pituitary Adenoma Patients Treated with Linac-Based Stereotactic Radiosurgery and Radiotherapy: a Long Term Experience in Thailand

  • Puataweepong, Putipun;Dhanachai, Mantana;Hansasuta, Ake;Dangprasert, Somjai;Sitathanee, Chomporn;Swangsilpa, Thiti;Vitoonpanich, Patamintita;Yongvithisatid, Pornpan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.13
    • /
    • pp.5279-5284
    • /
    • 2015
  • Background: The study analyzed the long term clinical outcomes of pituitary adenoma cases treated with the first Thailand installation of a dedicated Linac-based stereotactic radiation machine (X-Knife). Materials and Methods: A retrospective review of 115 consecutive pituitary adenoma patients treated with X-Knife at the Faculty of Medicine, Ramathibodi Hospital, Bangkok, Thailand from 1997 to 2003 was performed. Stereotactic radiosurgery (SRS) was selected for 21 patients (18%) including those with small tumors (${\leq}3cm$) located ${\geq}5mm$. from the optic apparatus, whereas the remaining 94 patients (82%) were treated with fractionated stereotactic radiotherapy (FSRT). Results: With a median follow-up time of 62 months (range, 21-179), the six-year progression free survival was 95% (93% for SRS and 95% for FSRT). The overall hormone normalization at 3 and 5 years was 20% and 30%, respectively, with average time required for normalization of approximately 16 months for SRS and 20 months for FSRT. The incidence of new hypopituitarism was 10% in the SRS group and 9% in the FSRT group. Four patients (5%) developed optic neuropathy (1 in the SRS group and 3 in the FSRT group). Conclusions: Linac-based SRS and FSRT achieved similar high local control rates with few complications in pituitary adenoma cases. However, further well designed, randomized comparative studies between SRS versus FSRT particularly focusing on hormone normalization rates are required.