• 제목/요약/키워드: LIGHT

검색결과 31,946건 처리시간 0.049초

광 강도 제어에 따른 LED의 광질에 관한 연구 (A Study on Light Quality of LED for Control of Light Intensity)

  • 박상희;안준철;허정욱;최한고;최성대
    • 한국기계가공학회지
    • /
    • 제11권6호
    • /
    • pp.175-182
    • /
    • 2012
  • Light characteristics of the monochromatic red(R), blue(B), green(G) and white(W) and the mixed LED (B-R LED) were investigated by light control a Spectrometer-MMS1 and an illuminometer. The power consumption of each LED was 1W and R LED has five wavelength bands(600nm, 640nm, 660nm, 680nm, 750nm). The light intensity of each LED was changed in a range 10~100%. As a results, the wavelength and the spectrum distribution of R LED increase with increasing light intensity but the wavelength of B, G, W LED decreases. It was found that illumination of each mononochromatic and B-R LED increases linearly with increasing light intensity. It was confirmed that the illumination intensity of R-B light has greater values than those obtained by monochromatic light at the same conditions.

브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교 (The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods)

  • 신재호;임용규;이동렬
    • 대한치과교정학회지
    • /
    • 제34권4호
    • /
    • pp.333-342
    • /
    • 2004
  • 기존의 가시광선 중합기와 비교해서 plasma are light와 LED) 방식의 중합기를 이용해 브라켓을 치아표면에 접착한 후 탈락시키는 실험을 시행해 각각의 중합방식별로 전단결합강도와 접착파절양상을 비교함으로써 임상에서의 유용성을 평가하고자 하였다. 교정치료를 위해 발거한 상, 하악 소구치 60개를 윈통형의 레진블록에 매몰하여 시편을 제작하였다. 광중합형 접착레진인 Transbond XT를 이용하여 광중합 방식별로 조건(가시광선 중합기는 40초, LED방식의 중합기는 20춘, 그리고 plasma arc light 방식의 중합기는 3초)에 따라 브라켓을 접착한 후 만능물성실험기로 전단결합강도를 측정하고 브라켓 기저면을 광학현미경으로 관찰해 접착파절양상을 관찰하여 다음과 같은 결과를 얻었다. 1. 가시광선 중합방식과 LED 중합방식으로 중합시킨 군간에 전단결합강도의 유의성 있는 차이는 없지만 plasma arc Light방식으로 중합시킨 군은 앞의 두 군에 비해 유의성이 있게 작은 간을 나타내었다(p>0.05). 2. 가시광선 중합방식으로 중합한 군과 LED방식을 이용한 군에서는 파절양상이 거의 유사하게 나타났다. 두 군 모두 잔류접착제가 치아면에만 있는 경우가 제일 적은 비율을 도였으며 브라켓 기저면에 50% 이상의 집착제가 남아 있는 양상이 더 큰 비율을 보였다. 3. Plasma arc light 로 중합시킨 경우에는 접착제가 브라켓 기저면에 50% 이하로 남아있는 양상이 큰 비율로 나타났으며 잔류 접착제 전체가 치아면에 남아 있는 경우는 15%였다. 이상의 실험결과 plasma arc light를 이용한 중합 방식이 가시광선이나 LED 방식을 이용한 중합 방식에 비해 유의성 있게(p>0.05) 낮은 전단결합강도를 보였으나 세 방식 모두 인상적으로 사용하기에 충분한 전단결합강도를 보여 유용하게 사용할 수 있음을 알 수 있었다.

레이저와 프라즈마와의 비선형상오작용에 관한 연구 -분광법에 의한 제 2고주파와 Brillouin 산람광의 검출- (Study on the Nonlinear Interaction of Laser with Plasma -Detection of Second Harmonic Light and Brillouin Scattering Light by Means of Spectroscopic Technique-)

  • Kang, Hyung-Boo
    • 대한전기학회논문지
    • /
    • 제33권5호
    • /
    • pp.173-180
    • /
    • 1984
  • The spectra of scattering light fromlaser-produced plasma near its fundamental and second harmonic wavelength were observed respectively by means of spectroscopic technique. The experimental results and the generation mechanism of nonlinear effects such as the second garmonics and the brillouin scattering were analysed theoretically. The spectra of reflected laser light became wider than that of incident laser light. And the peak of spectrum of reflected light shifted to red-side from that of incident light. The second harmonic light is generated from the nonlinear interaction of the incident laser light and the electron plasma wave excited in resonance region by the oblique incidence of laser light to the plasma. The Brillouin backscattering from laser-produced plasmas of hydrogen and deuterium has shown an isotope effect in the red-side region of the generated second harmonic light. This isotope shift is explained by the parametric instability at the cutoff (resonance) region using frequency-and phase-matching conditions of the waves.

  • PDF

Effects of Light on Disassembly of Chloroplast during Senescence of Detached Leaves in Phaseolus vulgaris

  • Dong-Hee Lee;Jun
    • 한국환경과학회지
    • /
    • 제1권2호
    • /
    • pp.69-80
    • /
    • 1992
  • Effects of light on leaf senescence of Phseolus vulgaris were investigated by measuring the disassembly of chlorophyll-protein complexes in detached leaves which had been kept in the dark or under light. The loss of chlorophyll accompanied by degradation of chlorophyll- protein complexes. PSI (photosystem I) complex containing LHCI (light harvesting complex of PSI) apoproteins was rapidly decreased after the early stage of dark-induced senescence. RC(reaction center)-Cores was slightly increased until 4 d and slowly decreased thereafter. As disassembly of LHCII trimer progressed after the late stage of senescence, there was a steady increase in the relative amount of SC(small complex)-2 containing LHCII monomer. On the other hand, white and red light adaptation caused the structural stability of chlorophyll-protein complexes during dark-induced senescence. Particularly, red light was more effective in the retardation of LHCII breakdown than white light, whereas white light was slightly effect in protecting the disassembly of PSI complex compared to red light. These results suggest, therefore, that light may be a regulatory factor for stability of chlorophyll-protein complexes in the senescent leaves.

  • PDF

The Effect of Different Light Quality on the Change of Membrane PD of the Guard Cell in Tradescantia virginiana L.

  • Lee, Joon-Sang
    • 환경생물
    • /
    • 제22권1호
    • /
    • pp.89-92
    • /
    • 2004
  • The effects of different light quality on the change of membrane potential difference (PD) of the guard cell in the intact leaf have been investigated. The mombrane PD was about -5.5 mV by white light of 600 $\mu$moles $m^{-2}\; s^{-1}$. The mean PD of change caused by red light was about -5.2 mV at the light intensity of 80 $\mu$moles $m^{-2}\; s^{-1}$. Membrane PD of guard cells in response to blue light was saturated at low light intensity. However, red and green light enhanced the change of membrane PD of guard cells with increasing intensity. In green light the biggest change of memrane PD was around -4 mV, whereas, with blue light the change of of memrane PD was around -2 mV. Accordingly, the membrane PD of guard cell showed the different degree of hyper-polarization by each wavelength.

LED Light Coupler Design for a Ultra Thin Light Guide

  • Lee, J.H.;Chang, W.;Choi, D.
    • Journal of the Optical Society of Korea
    • /
    • 제11권3호
    • /
    • pp.113-117
    • /
    • 2007
  • A LED light coupler is proposed for coupling light from a mini side LED of 0.4 mm height to a very thin (${\sim}0.3 mm$) light guide. Due to the ultra thinness of the light guide, conventional light couplings between LEDs and light guides do not provide adequate coupling efficiency. The designed LED coupler is a compound lens of 3.5 mm length, 1.2 mm height, and 3.3 mm width. The courier first collimates the light from the LED and then concentrates the light in a manner similar to a compound parabolic concentrate, (CPC) into the light guide. The exit surface of the coupler is additionally textured to have micro patterns in order to control the radiance profile.

Design and analysis of the lens converting the spot light into the line light

  • 최규만;이해춘
    • 한국정보전자통신기술학회논문지
    • /
    • 제1권2호
    • /
    • pp.21-25
    • /
    • 2008
  • A CCFL which commonly used in the back light units for the LCD, possess very high brightness hence, was widely used as a line light source. However, the use of CCFL, caused for several environmental concerns since it contain highly toxic mercury, gradually replaced into a LED. But the LED is a spot light source, the dark area occurs in the surface of the back light units. In this paper, we proposed the lens that can convert the spot light into the line light and it can remove the dark area in the surface of the back light units. The lens is composed with the light condensation part and the light guiding part. The conditions obtained will be helpful to plan an optimum structure for such preparation.

  • PDF

인공 광원을 이용한 실내 조명 효과에 대한 기초 실험 연구 (Basic Experimental Study on Room Lighting Effects using Artificial Light Source)

  • 김정배
    • 융복합기술연구소 논문집
    • /
    • 제1권1호
    • /
    • pp.29-33
    • /
    • 2011
  • This study is performed to investigate the effect of the artificial light for room lightening. To do that, the experiments were done using the black room with 1m3 and performed to show the effect of the length between the room and light source and light intensities as LUX. The LUX of 18 sites in the room was measured using LUX meter. The length between the room and the light source was chosen as 500mm, 1000mm, and 1500mm and the light intensities was 3 levels. The results were shown the distinct difference between the part directly projected through the light path and non-directly projected. So, the light delivery path have to be modified for next step research. The results were very sensitive for the part directly projected through the light path. This study showed the basic results for room lightening using light source to simulate the solar lightening and was worth in a strict sense as fundamental study.

  • PDF

Research on the Influence of Polarization Aberration on Heterodyne Efficiency in Space Coherent Laser Communication System

  • Zheng, Yang;Piao, Yu
    • Current Optics and Photonics
    • /
    • 제6권1호
    • /
    • pp.23-31
    • /
    • 2022
  • Heterodyne efficiency is an indicator to evaluate the performance of space coherent laser communication systems. It is affected by signal light and local oscillator (LO) light amplitude, phase and polarization state. In this paper, based on the common heterodyne efficiency, a heterodyne efficiency model that can reflect polarization aberration of optical system is proposed. The heterodyne efficiency is analyzed when the signal light and the LO light are linearly polarized or circularly polarized. For a coherent communication optical system, when the incident signal light is right-circularly polarized light and the incident LO light is 45° linear polarized light. Based on the three-dimensional ray tracing theory and the heterodyne efficiency proposed in this paper, the change of polarization states and the distribution of heterodyne efficiency of the signal light and LO light influenced by the optical system's polarization aberration are analyzed. Analysis shows that the heterodyne efficiency model proposed in this paper can be used to evaluate coherent communication systems and reflect the influence of optical system polarization aberration.

청색광이 광중합기용 팁과 보안경에 따라 투과되는 투과율 차이 비교의 융합적 연구 (A Convergence Study on Comparison of the Difference in the Blue-Light Transmittance by Goggles and Dental Curing Light Unit Tips)

  • 이숙정
    • 한국융합학회논문지
    • /
    • 제10권12호
    • /
    • pp.177-181
    • /
    • 2019
  • 본 연구는 광중합기의 청색광을 이용한 치과 치료과정에서 광중합기용 팁들과 보안경의 청색광 차단정도를 알아보기 위해, UV-Vis 스펙트로미터 기기에 광중합기용 팁들과 보안경들을 위치시키고 빛을 투과하여 측정한 결과를 비교 분석하였다. 분석결과, 분석에 사용한 4가지 종류의 광중합기용 팁들 모두 청색광 차단효과가 매우 우수한 것으로 나타났다. 보안경의 경우 붉은색 계열 보안경이 노란색 계열 보안경보다 광중합기용 팁들과 유사한 청색광 투과율을 보여 청색광 차단효과가 더 우수한 것으로 나타났다. 결과적으로 청색광 차단정도가 높은 광중합기용 팁 부착과 보안경 착용이 눈 보호를 위해 필요한 행위임을 추천한다. 이러한 행위는 눈에 대한 지속적인 자극과 피로감을 줄여줄 것이라 사료된다.