• Title/Summary/Keyword: LENS

Search Result 3,811, Processing Time 0.026 seconds

The Developement of Small 360° Oral Scanner Lens Module (소형 360° 구강 스캐너 렌즈 모듈 개발)

  • Kwak, Dong-Hoon;Lee, Sun-Gu;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.858-861
    • /
    • 2018
  • In this paper, we propose the development of a small $360^{\circ}$ oral scanner lens module. The proposed small $360^{\circ}$ oral scanner lens module consists of a small $360^{\circ}$ high resolution(4MegaPixel) lens optical system, a 15mm image sensor unit, and a small $360^{\circ}$ mouth scanner lens external shape. A small $360^{\circ}$ high resolution lens optical system produces a total of nine lenses, the outer diameter of the lens not less than 15mm for use by children through the ages of adulthood. Light drawn by a small $360^{\circ}$ high resolution lens optical system is $90^{\circ}$ flexion so that image images are delivered to image sensors. The 15mm image sensor unit sends the converted value to the ISP(Image Signal Processor) of the embedded board after an image array through the column and the row address of the image sensor. The small $360^{\circ}$ mouth scanner lens outer shape was designed to fix the race to the developed lens. Results from authorized testing agencies to assess the performance of proposed small $360^{\circ}$ oral scanner lens modules, The optical resolving power of $360^{\circ}$ lens was more than 30% at 150 cycles/mm, $360^{\circ}$ lens angle was $360^{\circ}$ in vertical direction, $42^{\circ}{\sim}85^{\circ}$ in vertical direction, and lens distortion rate was 5% or less. It produced the same result as the world's highest level.

Change in Axial Rotation of Toric Soft Contact Lens according to Tear Volume (눈물양에 따른 토릭 소프트콘택트렌즈의 축 회전양 변화)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.445-454
    • /
    • 2015
  • Purpose: The present study was aimed to investigate the effect of tear volume on a change of axial rotation according to wearing time of toric soft contact lens and gaze directions. Method: Toric soft contact lenses with double thin zone design applied on 62 eyes. Then, changes in non invasive tear film break-up time and the rotational direction/amount of lens when changing gaze direction were respectively measured after 15 minutes and 6 hours of lens wear. Results: Lens rotation to temporal direction was more found when changing gaze direction after lens wear. However, its rotation was varied according to wearing time and the subjects' tear volume. Furthermore, the frequency of lens rotation to temporal direction was higher in dry eyes compared with normal eyes at nearly all gaze directions after 15 minutes and 6 hour of lens wear. The rotational amount of lens was generally greater in dry eyes after 15 minutes of lens wear. However, its difference between normal eyes and dry eyes was not great after 6 hours of lens wear. Conclusion: The present study revealed that axial rotation of toric soft contact lens was varied according to the wearer's tear volume and lens rotational patterns at the initial, and extending periods of lens wear were different. The change in rotational pattern of toric soft contact lens from these results means the possibility of visual change after extending lens wear, and the identification of its correlation with tear volume suggests the necessity of considering factors for choosing appropriate toric soft contact lens.

Simulation of Lens Aberration Correction for Polygon Mirror Scanning (PMS) (Polygon Mirror Scanning (OMS)을 위한 렌즈의 구면 수차 보정 시뮬레이션)

  • 신승연
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1999.08a
    • /
    • pp.128-129
    • /
    • 1999
  • Polygon Mirror Scanning(PMS) is composed of LED array, magnifying lens, polygon mirror and motor. It is important to correct the lens aberrations to gain the image we want to show. In this paper, we have simulated the lens aberration correction to reduce the spherical aberration . We have obtained a aspherical lens which is corrected the spherical aberration.

  • PDF

Design and Implementation of an Approximate Surface Lens Array System based on OpenCL (OpenCL 기반 근사곡면 렌즈어레이 시스템의 설계 및 구현)

  • Kim, Do-Hyeong;Song, Min-Ho;Jung, Ji-Sung;Kwon, Ki-Chul;Kim, Nam;Kim, Kyung-Ah;Yoo, Kwan-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.10
    • /
    • pp.1-9
    • /
    • 2014
  • Generally, integral image used for autostereoscopic 3d display is generated for flat lens array, but flat lens array cannot provide a wide range of view for generated integral image because of narrow range of view. To make up for this flat lens array's weak point, curved lens array has been proposed, and due to technical and cost problem, approximate surface lens array composed of several flat lens array is used instead of ideal curved lens array. In this paper, we constructed an approximate surface lens array arranged for $20{\times}8$ square flat lens in 100mm radius sphere, and we could get about twice angle of view compared to flat lens array. Specially, unlike existing researches which manually generate integral image, we propose an OpenCL GPU parallel process algorithm for generating real-time integral image. As a result, we could get 12-20 frame/sec speed about various 3D volume data from $15{\times}15$ approximate surface lens array.

Thermal Deformation Measurement Spherical Glasses Lens Using ESPI (ESPI를 이용한 안경용 렌즈의 열변형 측정)

  • Kim, Koung-Suk;Jang, Ho-Sub;Kim, Hyun-Min;Yang, Seung-Pill
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.137-143
    • /
    • 2008
  • The spherical glasses lenses are typically classified into two groups such as (+) diopter lens and (-) diopter lens by the refractive power index. The thermal deformation of a lens is occurred by external heat source and is changed respected to the diopter of a lens. In this paper, the thermal deformation of spherical glasses lenses were quantitatively measured by using ESPI (electronic speckle pattern interferometry) which has an advantage that the non-contact, non-destructive and precise deformation measurement is available due to the coherency characteristic. The temperature changes were measured by IR camera. It makes experiments over 14 types of the plastic glasses lenses. From the results, it was confirmed that the larger diopter lens showed the less thermal deformation in case of the (+) diopter lens. On the other hand, the thermal deformation of the (-) diopter lens was measured with uniform pattern when the same temperature changes were applied. Also, it was found that the thermnal deformation of the (+) diopter lens is less than that of the (-) diopter lens. Therefore, it is expected that when the thermal deformation is occurred to the various types of the lens, the variation of the focal length caused by the thermal distortion of a lens would be measured quantitatively.

Design of a Rod-Type Aspheric Lens Collimator for Optical Telecommunication (막대 형태의 비구면 렌즈를 이용한 광통신용 시준기의 설계)

  • Kang, Seok-Bong;Kang, Eun-Kyoung;HwangBo, Chang-Kwon;Kang, Sang-Do;Kim, Jong-Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.31-35
    • /
    • 2008
  • A rod-type aspheric lens collimator for the optical telecommunication system which shows high coupling efficiency and experiences small coupling loss for misalignment errors is designed. The working distance, thickness, and diameter of the rod-type aspheric lens are determined to be close to those of the GRIN lens collimator in order to replace the GRIN lens with the rod-type aspheric lens. Since the coupling loss mainly originated from the spherical aberration of the lens, the spherical aberration in the rod-type aspheric lens is reduced drastically, and it turns out that the coupling efficiency of the rod-type aspheric lens collimator is higher than that of the available collimators, such as ball lens, GRIN lens, and C-type lens collimators.

A Study on the Effect of Shrinkage on Lens Deformation in Optical Lens Manufacturing Process Using Thermosetting Resin Material (열경화성 수지 재료를 이용한 광학 렌즈 제조공정에서 렌즈 변형에 대한 수축률이 영향에 관한 연구)

  • Park, Si Hwan
    • Design & Manufacturing
    • /
    • v.16 no.3
    • /
    • pp.9-15
    • /
    • 2022
  • In order to reduce the manufacturing costs of the glass lens, it is necessary to manufacture a lens using a UV curable resin or a thermosetting resin, which is a curable material, in order to replace a glass lens. In the case of forming a lens using a thermosetting material, it is necessary to form several lenses at once using the wafer-level lens manufacturing technologies due to the long curing time of the material. When a lens is manufactured using a curable material, an error in the shape of the lens due to the shrinkage of the material during the curing process is an important cause of defects. The major factors for these shape errors and deformations are the shrinkage and the change of mechanical properties in the process of changing from a liquid material during curing to a solid state after complete curing. Therefore, it is necessary to understand the curing process of the material and to examine the shrinkage rate and change of physical properties according to the degree cure. In addition, it is necessary to proceed with CAE for lens molding using these and to review problems in lens manufacturing in advance. In this study, the viscoelastic properties of the material were measured during the curing process using a rheometer. Using the results, Rheological investigation of cure kinetics was performed. At the same time, The shrinkage of the material was measured and simple mathematical models were created. And using the results, the molding process of a single lens was analyzed using Comsol, a commercial S/W. In addition, the experiment was conducted to compare and verify the CAE results. As a result, it was confirmed that the shrinkage rate of the material had a great influence on the shape precision of the final product.

Research to Minimize Endoscope and Objective-lens Sensitivity Using Multi-configurations (다중 구성을 이용한 내시경 및 대물렌즈 광학계 공차 민감도 최소화 설계 기술)

  • Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.259-265
    • /
    • 2021
  • Recently, lens manufacturing and assembly technology has greatly improved. However, tight requirements of manufacturing and assembly lead to an increase in cost and manufacturing time, and in some cases the performance of an optical system may deteriorate depending on the operating environment's conditions, such as temperature or vibration. In addition, the use of a compensator is an effective method to reduce sensitivity in an ultra-precision optical system, but in the case of a small lens, such as that in an endoscope, it is difficult to use a compensator due to the size limitation of the lens barrel. Therefore, minimizing lens sensitivity is the most important technology in lens design. For this reason, there have been various attempts to reduce the lens sensitivity, and there is a trend to add functions to reduce the sensitivity in the lens design S/W. In this paper, we introduce a design technology that minimizes lens sensitivity. We first design a lens with quite good performance, then analyze the sensitivity of this lens, make a multi-configuration with high-sensitivity element error, and then reoptimize it. We prove with an example that this design technique is very effective.

Measurement of Refractive Power by Reflective image on the Negative Spherical Lens ((-) 구면 렌즈 면의 반사상에 의한 굴절력 측정)

  • Choi, Woon-Sang;Kim, Tae-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.417-421
    • /
    • 2004
  • We can see that two images of reflection are observed on the surface of a ophthalmic lens. These are the image reflected from front surface and back surface of lens, respectively. The reflective image shows to be affect by surface refractive power of front and back surface of lens. Total refractive power of lens is calculated by refractive power of front and back surface of lens. Accordingly, the ratio of image on the lens surface is able to measure refractive power of ophthalmic lens without helping of the lensmeter. The ratio of two reflective image measured on the lens surface is compared with the calculated ratio by the power measurement.

  • PDF

Optics of the light-weight and foldable telescope based on the Fresnel lens

  • Yu, Hyungjoon;Park, Yong-Sun;Chung, Haeun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.57.3-58
    • /
    • 2016
  • We analyze an optical system of a telescope based on Fresnel type objective lens as suggested by Hyde (1999). The Fresnel objective lens can be thin, light-weight and foldable, and therefore it is possible to develop a space telescope with an aperture larger than that of traditional telescopes. Moreover a lens, whatever it is either Fresnel type or conventional, allows much larger fabrication tolerances. We design a medium-sized telescope adopting Fresnel lens as an objective lens for use in space and possibly on the ground. The well-known chromatic aberration of the Fresnel primary lens is corrected by a field lens and another Fresnel lens using Schupmann method. An additional lens is used for forming images. We analyze the chromatic and off-axis aberrations of the proposed system analytically and suggest methods for the minimization of off-axis aberrations and for the operation in wider spectral range. We also conduct ray tracing and optimize the whole optical system with commercial software. Finally we present the design parameters of a telescope with an aperture of 0.5 to 1 meters, enabling diffraction limited operation for a moderate field of view about 10 arc-minutes.

  • PDF