• 제목/요약/키워드: LED sensor

검색결과 490건 처리시간 0.023초

스마트폰 사용자를 위한 발광 스마트 백 개발 (A Study on the Development of Luminous Smart Bag for Smartphone Users)

  • 박진희;김주용
    • 패션비즈니스
    • /
    • 제24권1호
    • /
    • pp.15-28
    • /
    • 2020
  • The purpose of this study was to develop and propose creative smart bags in emotional e-textiles using LEDs that inform smartphone users of motion-induced luminescence and ringing of cell phones. The LED light-emitting operation tasks produced in the study were applied to each of the three design smart bags, setting the five cases of luminance by a call initiated, absent phone, rejecting answering phone, texting, and motion-induced luminescence. In the male laptop bags of LED luminous images using wappen, 10 LEDs could be separated by a total of three pins to display the luminous mode, and all 10 LEDs became a total of five luminous patterns, including all that illuminate and those that illuminate randomly. E-wappen rendered the motif a strong sense of visibility and performed six roles on phone rings and texting. To develop a women's tote bag, we did a laser cut and attached the leather strips and placed 10 triangular LEDs to form a geometric LED e-textile. It provides the possibility of transforming simple design from traditional fashion into a more interesting and various smart designs. An entertainment smart bag using graphic design was constructed by applying a tilt sensor to look like a light in the night sky by shaking and moving the bag. The graphic design and composition of LEDs indicate that LEDs and fashion item are applied in harmony rather than heterogeneous, enabling them to be applied as fashion-oriented wearable smart products.

계단형 양자우물 구조가 적용된 센서 광원 용 발광다이오드 소자 (Light Emitting Diode with Multi-step Quantum Well Structure for Sensing Applications)

  • 박성민;이승주;우자정;김유경;장수환
    • 센서학회지
    • /
    • 제32권6호
    • /
    • pp.441-446
    • /
    • 2023
  • Electrical and optical characteristics of the GaN-based light-emitting diode (LED) with the improved multi-quantum well (MQW) structure have been studied for light source in bio-sensing systems. Novel GaN/In0.1GaN/In0.2GaN/In0.1GaN/GaN and Al0.1GaN/GaN/In0.2GaN/GaN/Al0.1GaN (MQW) structures were suggested, and their radiative recombination rate, light output power, electroluminescence, and external quantum efficiency were compared with those of the conventional GaN/In0.2GaN/GaN MQW structure using device simulation. The LED with the GaN/In0.1GaN/In0.2GaN/In0.1GaN/GaN MQW structure showed an excellent recombination rate of 5.57 × 1028 cm-3·s-1 that was more than one order improvement over that of the conventional LED. In addition, the efficiency droop was relieved by the suggested stepped MQW structure.

EOM-BSO 소자를 이용한 광전압센서에 관한 연구 (A Study on the Fiber-Optic Voltage Sensor Using EMO-BSO)

  • 김요희;이대영
    • 대한전자공학회논문지
    • /
    • 제27권11호
    • /
    • pp.119-125
    • /
    • 1990
  • 전기광학 소자인 비스무스 실리콘 옥사이드($Bi_{12}SiO_{20}$ : 이하 BSO라 칭함)와 편광자(polarizer), 1/4파장판(1/4 waveplate), 검광자(analyzer)와 결합하여 광변조기를 만들었고 이를 전압세선로 이용할 수 있도록 전기광학 측정 시스템을 구성하고 그 특성을 실험하였다. 송수신부인 E/O 변환기 및 O/E 변환기는 LED와 PIN-PD로 구성하여 구동되며 전송로는 코아/클래드경이 $100/140{\mu}m$인 멀티모드 광파이버를 사용하였다. 센서부와 광파이버 사이에는 셀폭 마이크로렌즈로서 결합하였다. 실험에 앞서 맥스웰 방정식과 파동방정식을 이용하여 BSO 단결성 내부에서 일어나는 광파의 전파특성에 관한 행렬식을 구하였고 센서가 갖는 광강도 변조식을 유도하였다. 실험 결과로부터 제작된 BSO 전압 센서는 교류전압 50V~800V(60Hz)에서 ${\pm}2.5{\%}$ 측정오파를 보였다. 인가전압의 증가에 따라 출력의 포화값이 커지는데 이러한 현상은 광강도 변조식에서 센서의 선광성에 기인한다는 것을 확인할 수 있었다. 센서의 온도특성 실험결과 $-20^{\circ}C~60^{\circ}C$에서 변화율은 ${\pm}0.6{\%}$ 이하로 측정되었다. 주파수 특성실험 결과 DC~100KHz까지 양호한 특성을 나타냄을 확인할 수 있었다.

  • PDF

Development, Validation, and Application of a Portable SPR Biosensor for the Direct Detection of Insecticide Residues

  • Yang, Gil-Mo;Cho, Nam-Hong
    • Food Science and Biotechnology
    • /
    • 제17권5호
    • /
    • pp.1038-1046
    • /
    • 2008
  • This study was carried out to develop a small-sized biosensor based on surface plasmon resonance (SPR) for the rapid identification of insecticide residues for food safety. The SPR biosensor module consists of a single 770 nm-light emitting diodes (LED) light source, several optical lenses for transferring light, a hemisphere sensor chip, photo detector, A/D converter, power source, and software for signal processing using a computer. Except for the computer, the size and weight of the sensor module are 150 (L)$\times$70 (W)$\times$120 (H) mm and 828 g, respectively. Validation and application procedures were designed to assess refractive index analysis, affinity properties, sensitivity, linearity, limits of detection, and robustness which includes an analysis of baseline stability and reproducibility of ligand immobilization using carbamate (carbofuran and carbaryl) and organophosphate (cadusafos, ethoprofos, and chlorpyrifos) insecticide residues. With direct binding analysis, insecticide residues were detected at less than the minimum 0.01 ppm and analyzed in less than 100 sec with a good linear relationship. Based on these results, we find that the binding interaction with active target groups in enzymes using the miniaturized SPR biosensor could detect low concentrations which satisfy the maximum residue limits for pesticide tolerance in Korea, Japan, and the USA.

Software Design of Packet Analyzer based on Byte-Filtered Packet Inspection Mechanism for UW-ASN

  • Muminov, Sardorbek;Yun, Nam-Yeol;Park, Soo-Hyun
    • 한국멀티미디어학회논문지
    • /
    • 제14권12호
    • /
    • pp.1572-1582
    • /
    • 2011
  • The rapid growth of UnderWater Acoustic Sensor Networks (UW-ASNs) has led researchers to enhance underwater MAC protocols against limitations existing in underwater environment. We propose the customized robust real-time packet inspection mechanism with addressing the problem of the search for the data packet loss and network performance quality analysis in UW-ASNs, and describe our experiences using this approach. The goal of this work is to provide a framework to assess the network real-time performance quality. We propose a customized and adaptive mechanism to detect, monitor and analyze the data packets according to the MAC protocol standards in UW-ASNs. The packet analyzing method and software we propose is easy to implement, maintain, update and enhance. We take input stream as real data packets from sniffer node in capture mode and perform fully analysis. We were interested in developing software and hardware designed tool with the same capabilities which almost all terrestrial network packet sniffers have. Experimental results confirm that the best way to achieve maximum performance requires the most adaptive algorithm. In this paper, we present and offer the proposed packet analyzer, which can be effectively used for implementing underwater MAC protocols.

Development of IoT based Real-Time Complex Sensor Board for Managing Air Quality in Buildings

  • Park, Taejoon;Cha, Jaesang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권4호
    • /
    • pp.75-82
    • /
    • 2018
  • Efforts to reduce damages from micro dust and harmful gases in life have been led by national or local governments, and information on air quality has been provided along with real-time weather forecast through TV and internet. It is not enough to provide information on the individual indoor space consumed. So in this paper, we propose a IoT-based Real-Time Air Quality Sensing Board Corresponding Fine Particle for Air Quality Management in Buildings. Proposed board is easy to install and can be placed in the right place. In the proposed board, the air quality (level of pollution level) in the indoor space (inside the building) is easy and it is possible to recognize the changed indoor air pollution situation and provide countermeasures. According to the advantages of proposed system, it is possible to provide useful information by linking information about the overall indoor space where at least one representative point is located. In this paper, we compare the performance of the proposed board with the existing air quality measurement equipment.

A Study on Realization of Visible Light Communication System for Power Line Communication Using 8-bit Microcontroller

  • Yun, Ji-Hun;Hong, Geun-Bin;Kim, Yong-Kab
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권5호
    • /
    • pp.238-241
    • /
    • 2010
  • The purpose of this study is to solve the problems of radio frequency bandwidth frequency depletion, confusion possibilities, and security that are in current wireless communications systems, and to confirm the possibility of applying those solutions for the next generation network. To solve the problems of the current wireless communications system, a visible light communications system for power line communication (PLC) via 8-bit microcontroller is created and the capacity is analyzed. The exclusive PLC chip APLC-485MA, an 8-bit ATmega16 microcontroller, high brightness 5pi light emitting diodes (LEDs), and the LLS08-A1 visible light-receiving sensor were used for the transmitter and receiver. The performance was analyzed using a designed program and an oscilloscope. The voltage change was measured as a function of distance from 10-50 cm. Blue LEDs showed the best performance among the measured LED types, with 0.47 V of voltage loss, but for a distance over 50 cm, precise data was not easy to obtain due to the weak light. To overcome these types of problems, specific values such as the changing conditions and efficiency value relevant to the light emitting parts and the visible light-receiving sensor should be calculated, and continuous study and improvements should also be realized for better communication conditions.

Multi-point detection of hydrogen using the hetero-core structured optical fiber hydrogen tip sensors and Pseudorandom Noise code correlation reflectometry

  • Hosoki, Ai;Nishiyama, Michiko;Igawa, Hirotaka;Seki, Atsushi;Watanabe, Kazuhiro
    • 동력기계공학회지
    • /
    • 제19권3호
    • /
    • pp.11-15
    • /
    • 2015
  • In this paper, the multi-point hydrogen detection system based on the combination of the hetero-core optical fiber SPR hydrogen tip sensor and interrogator by pseudorandom noise (PN) code correlation reflectometry has been developed. In a light intensity-based experiment with an LED operating at 850 nm, it has been presented that a transmitted loss change of 0.32dB was induced with a response time of 25 s for 4% $H_2$ in $N_2$ in the case of the 25-nm Au, 60-nm $Ta_2O_5$, and 5-nm Pd multi-layers film. The proposed sensor characteristic shows excellent reproducibility in terms of loss level and time response for the in- and out- $H_2$ action. In addition, in the experiment for multi-point hydrogen detection, all sensors show the real-time response for 4% hydrogen adding with reproducible working. As a result, the real-time multi-point hydrogen detection could be realized by means of the combination of interrogating system and hetero-core optical fiber SPR hydrogen tip sensors.

Fabrication and Characterization of Porous Non-Woven Carbon Based Highly Sensitive Gas Sensors Derived by Magnesium Oxide

  • Kim, Yesol;Cho, Seho;Lee, Sungho;Lee, Young-Seak
    • Carbon letters
    • /
    • 제13권4호
    • /
    • pp.254-259
    • /
    • 2012
  • Nanoporous non-woven carbon fibers for a gas sensor were prepared from a pitch/polyacrylonitrile (PAN) mixed solution through an electrospinning process and their gas-sensing properties were investigated. In order to create nanoscale pores, magnesium oxide (MgO) powders were added as a pore-forming agent during the mixing of these carbon precursors. The prepared nanoporous carbon fibers derived from the MgO pore-forming agent were characterized by scanning electron microscopy (SEM), $N_2$-adsorption isotherms, and a gas-sensing analysis. The SEM images showed that the MgO powders affected the viscosity of the pitch/PAN solution, which led to the production of beaded fibers. The specific surface area of carbon fibers increased from 2.0 to $763.2m^2/g$ when using this method. The template method therefore improved the porous structure, which allows for more efficient gas adsorption. The sensing ability and the response time for the NO gas adsorption were improved by the increased surface area and micropore fraction. In conclusion, the carbon fibers with high micropore fractions created through the use of MgO as a pore-forming agent exhibited improved NO gas sensitivity.

냉각탑 수질관리를 위한 자동화 시스템 개발 (Water Quality Control System Development for Cooling Towers)

  • 이기건;송무준;이영재;성상경;강태삼
    • 제어로봇시스템학회논문지
    • /
    • 제14권1호
    • /
    • pp.36-41
    • /
    • 2008
  • Cooling tower is an important equipment of the cooling systems for large buildings like factory and department store. Water used for cooling in cooling tower is reused continuously. If the water is polluted, corrosion and scale can happen at equipments and pipes. In order to prevent this problem, it is necessary to control the water quality using chemicals. To control the water quality, an automatic control system is designed, fabricated, and experimented. The control system is based on an imbedded microcontroller. Relays are used for power driving, an LCD and LED for display, and RS485 for remote data acquisition. Monitoring program is also developed for easy man-machine interface and extraction of data stored in the imbedded processor and EEPROM. The control system calculates amounts of chemicals necessary using sensor data and injects the chemicals into the cooling tower on proper time. The developed water quality control system is expected to reduce cost of maintenance and extend the lifetime of the cooling systems with low cost.