• Title/Summary/Keyword: LED Cooling

Search Result 142, Processing Time 0.026 seconds

Development of a Low-cost Automatic Water Quality Diagnosis System for Cooling Towers (저가형 냉각탑 자동 수질 진단 시스템 개발)

  • Kim, Jung Hwan;Park, Han-Bin;Kang, Taesam;Park, Jungkeun
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.58-65
    • /
    • 2014
  • We developed a low-cost automatic diagnosis system for water quality in cooling towers to measure the concentrations of key ingredients such as $Ca^{2+}$, $Cl^-$, $PO{_4}^{3-}$, and $Fe^{2+}$. $Ca^{2+}$, and $Cl^-$ are the main factors that cause the generation of scale, corrosion, and sludge in water pipes. $PO{_4}^{3-}$ prevents corrosion, sludge and scale by inhibiting the ions (i.e., $Ca^{2+}$, $Cl^-$) from sticking to the pipes. $Fe^{2+}$ is an indicator of pipe corrosion. The proposed system consists of a microprocessor, a specimen container and heater, a precision pump, relays and valves, LED optical sources, and photo detectors. It automatically collects water samples and carries out pretreatment for determining the concentration of each chemical, and then estimates the concentration of each ion using low-cost LED optical sources and detectors. Experimental results showed that the accuracy of the proposed system is sufficiently high for water quality diagnosis and management of cooling towers, demonstrating the possibility of the proposed system's wide usage in real environments.

A Study on Thermal Performance of an Impinging Cooling Module for High Power LEDs (고출력 LED에 적용한 분사냉각모듈의 열성능에 관한 연구)

  • Lee, Dong Myung;Park, Sang Hee;Kim, Dongjoo;Kim, Kyoungjin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.1
    • /
    • pp.13-19
    • /
    • 2012
  • Thermal performance of an impinging cooling module for 150 W class high power LEDs have been investigated numerically and experimentally. Parametric studies were performed to compare the effect of several design parameters such as nozzle number, nozzle spacing, coolant flow rate, and impinging distance. The experiments were also carried out in order to validate the numerical results and the comparison between the experimental and numerical results showed good agreement. It is found that the overall thermal resistance of impinging cooling module strongly depends on the nozzle number, nozzle spacing, flow rate, and impinging distance. This results showed the optimized operating condition when number of nozzles is 25, nozzles spacing is 4mm, flow rate is 2.70 lpm, distance between nozzles and impinging surface is 2 mm.

A Study on the Numerical Analysis of Heat Sink for Radiant Heat of Automotive LED Head Lamp (자동차 LED Head Lamp의 방열을 위한 Heat Sink의 수치해석적 연구)

  • Choi, Byung-Hui;Kim, Chang-Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4398-4404
    • /
    • 2012
  • This thesis was conducted a numerical analysis on the radiant heat performance according to factors of design of heat sink for cooling of the automotive LED head lamp. The heat sinks were designed with 5 different types to fit the limited internal space by formula based on an existing product (Type 1). Designed heat sinks of five types were analyzed by ANSYS CFD V12.1, and the analysis results were compared with the existing type. The results of simulation were analyzed temperature distribution and average temperature, air flow characteristic, heat flux etc. This thesis was researched on the correlation of the cooling performance according to the heat sink structure and the fin shape. Through numerical analysis, could be confirmed heat sink Type 2 as the best results.

Water Quality Control System Development for Cooling Towers (냉각탑 수질관리를 위한 자동화 시스템 개발)

  • Lee, Ki-Keon;Song, Moo-Jun;Lee, Young-Jae;Sung, Sang-Kyung;Kang, Tae-Sam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.1
    • /
    • pp.36-41
    • /
    • 2008
  • Cooling tower is an important equipment of the cooling systems for large buildings like factory and department store. Water used for cooling in cooling tower is reused continuously. If the water is polluted, corrosion and scale can happen at equipments and pipes. In order to prevent this problem, it is necessary to control the water quality using chemicals. To control the water quality, an automatic control system is designed, fabricated, and experimented. The control system is based on an imbedded microcontroller. Relays are used for power driving, an LCD and LED for display, and RS485 for remote data acquisition. Monitoring program is also developed for easy man-machine interface and extraction of data stored in the imbedded processor and EEPROM. The control system calculates amounts of chemicals necessary using sensor data and injects the chemicals into the cooling tower on proper time. The developed water quality control system is expected to reduce cost of maintenance and extend the lifetime of the cooling systems with low cost.

Analysis of the experimental cooling performance of a high-power light-emitting diode package with a modified crevice-type vapor chamber heat pipe

  • Kim, Jong-Soo;Bae, Jae-Young;Kim, Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.8
    • /
    • pp.801-806
    • /
    • 2015
  • The experimental analysis of a crevice-type vapor chamber heat pipe (CVCHP) is investigated. The heat source of the CVCHP is a high-power light-emitting diode (LED). The CVCHP, which exhibits a bubble pumping effect, is used for heat dissipation in a high-heat-flux system. The working fluid is R-141b, and its charging ratio was set at 60 vol.% of the vapor chamber in a heat pipe. The total thermal conductivity of the falling-liquid-film-type model, which was a modified model, was 24% larger than that of the conventional model in the LED package. Flow visualization results indicated that bubbles grew larger as they combined. These combined bubbles pushed the working fluid to the top, partially wetting the heat-transfer area. The thermal resistance between the vapor chamber and tube in the modified design decreased by approximately 32%. The overall results demonstrated the better heat dissipation upon cooling of the high-power LED package.

A Study on the radiant Heat Characteristic According to Type and Array of LED Lighting Heatsink (LED 조명등 히트싱크 형상과 배열에 따른 방열특성에 관한 연구)

  • Jang, Hyun;Suh, Jeong Se;Yi, Chung Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.3
    • /
    • pp.54-60
    • /
    • 2013
  • Numerical analysis of the radiant heat characteristic around heatsink according to arrangement and shape of fin on 60W-LED lamp is conducted in this study. In the case of top blow blowing from upper side on LED lamp, there is just little difference in cooling characteristics according to the height of fin. On the other hand, the fin arranged side by side has the advantage of heat transfer enhancement by comparing with zig-zag type because it leads to more loss of flow. In case of making fin round to increase the amount of heat transfer, designing arrangement with the minimized loss of flow has the advantage of characteristic.

A Numerical Analysis in Piezoelectric Fan Systems (압전세라믹 냉각팬에 대한 수치해석적 연구)

  • Park, Ji-Ho;Kim, Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.994-1000
    • /
    • 2011
  • In this study, the piezoelectric fan cooling system is investigated. In order to find the proper geometry and configuration, the numerical model for the flow field and heat transfer investigation is used. A simplified nonlinear deformation model is employed for transient solutions of a piezoelectric fan with the dynamic mesh and user defined function capability. The results show that the cooling is most effective when the length of a piezoelectric fan is 5 cm and the cooling plate is 3 cm. The results can be used to develop a new design method of heat sink for piezoelectric fans.

Development of 1.2kW LED Light with Water-Air Circulation (수공냉 대류방식을 이용한 1.2kW급 LED 조명등 개발)

  • Yoon, Byung-Woo;Song, Jong-Kwan;Park, Jang-Sik;Kwon, Hong-Bae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.5
    • /
    • pp.615-622
    • /
    • 2015
  • As the development of high efficiency and high flux density LEDs, the trend of illumination lamp industry transfers from conventional-lamps to the LED-lamps. For energy efficiencies, LED lamps are superior to the conventional lamps, but they have heat problems. Especially, the heat problems are severe for the high luminance lamps. They degrade the soldering point of the metal PCB, and shorten the life cycle of LEDs. So, the solution of the heat sinking is very important to develop high luminance LED lamps. This study suggested a new method to solve the heat problems for high luminance LED lamps, and developed a LED lamp which has 1200W power. In this study, a water jacket is installed to the LED lamp, and the cooing water is circulated by a water pump.

The Cooling System for Head up Display (Head up Display용 냉각시스템)

  • Ji, Youg-Seok;Kim, Young-Seop;An, Byeong-Man;Lim, Sang-Min
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • Head up display’s cooling system is auto-diagnosed resulting from the external environment. The quantity of heat depending on this Head up display’s cooling system layout determines the speed of FAN for system cooling. In other words, a system’s heat quantity is planned through the air density depending on altitude, the amount of wind in air depending on FAN control condition, and the algorithm that is proportional to delta temperature. To detect the altitude, we use the criteria of delta T, which is determined by the subtracted value of LED junction temperature, and atmospheric temperature that is recorded on the Head up display system. Depending on the classification of delta T value, the altitude section is determined. While we can use GPS as the tool to detect the altitude, we should predict the change of the air density as the altitude alters, and should not just measure the altitude. And the value of delta T is used as the criterion of detecting the altitude for increasing the cooling efficiency of the car’s inner Head up display system with reflecting the speed of the FAN dependent upon the air density. In our theory, altitude is depending on the value of delta T and stabilizing or maintaining the system’s temperature by changing FAN’s rpm depending on determined value of altitude.