이온풍 공랭 방식 적용을 위한 방송용 LED 조명장치의 냉각 특성 해석 (Analysis of Cooling Characteristics of Broadcasting LED Light with Ion Wind Generator)

  • 박철우;이승준;김대중
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.693-698
    • /
    • 2012
  • In the present work, numerical analyses of broadcasting LED light with ion wind generator have been carried out for enhancement of cooling performance. Ion wind generator is produced and experimented before analysis. With the use of result of experiments, broadcasting LED light model is computed. Ion wind velocity into LED light is varied with 0~3 m/s. Based on the numerical results, the area of duct-type ion wind generator was designed to reduce the volume flow rate of ion wind. The modified inlet geometry shows sufficient cooling capability. And, through modified ion wind generator, the volume flow rate of ion wind has been largely reduced.

LED 모듈 표준 표시사항의 경제적인 평가를 위한 단일 핀 방열 블록의 냉각성능 예측 (Predicted Cooling Performance of Single Finned Heat Dissipating Block for Economic Assessment of LED Module Markings in Standards)

  • 허영준;송명호
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.81-91
    • /
    • 2015
  • LED has received intensive research attention due to its long life, high efficacy, fast response and wide colour availability, and has secured extensive application areas. However, LED chips within the modules convert only fraction of electric energy into light, and majority of supplied energy needs to be dissipated as heat, which challenges in the performance and life of the LED modules. IEC 62717 specifies the performance requirements for LED modules together with the test methods and conditions. The present study examined the influence of different design parameters on performance temperature through series of experiments and numerical simulations. The economic means to change the module performance temperature during the measurement of mandatory markings were suggested based on predicted cooling performances.

동도금 EP방열판에 의한 소형LED조명등 방열 (Heat Radiation of LED Light using eu Plating Engineering Plastic Heat Sink)

  • 조영태
    • 한국생산제조학회지
    • /
    • 제20권1호
    • /
    • pp.81-85
    • /
    • 2011
  • Recently, the electronic parts are to be thinner plate, smaller size, light weight material and CPU, HDD and DRAM in all the parts have been produced on the basis of the high speed and greater capacity. Also, conventional goods have replaced a LED (Light-Emitting Diode) in lighting products so; such industry devices need to have cooling. To maximize all the performance on the heat-radiated products, the area of heat-radiated parts is required to be cooled for keeping the life time extension and performance of product up. Existing cooling systems are using radiant heat plate of aluminum, brass by extrusion molding, heat pipe or hydro-cooling system for cooling. There is a limitation for bringing the light weight of product, cost reduction, molding of the cooling system. So it is proposed that an alternative way was made for bringing to the cooling system. EP (Engineering Plastic) of low-cost ABS (Acrylonitrile butadiene styrene Resin) and PC (Polycarbonate) was coated with brass and the coating made the radiated heat go up. The performance of radiant heat plate is the similar to the existing part. We have studied experimentally on the radiated heat plate for the light-weight, molding improvement and low-cost. From now on, we are going to develop the way to replace the exiting plate with exterior surface of product as a cooling system.

Comparative study on the effect of cooling & heating loads by lighting energy of various light sources in an office building

  • Hong, Won Pyo
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.94-105
    • /
    • 2016
  • The objective of the work was to evaluate the impact of lighting energy to cooling and heating consumption in medium scale office building, when currently installed fluorescent lights were replaced with various LED lighting fixtures. This evaluation comes from an integrated approach combining the proper indoor lighting environment and the thermal aspects of cooling & heating consumption in office building. These simulations were performed by coupling an appropriate luminaire analysis for energy consumption and a dynamic thermal simulation software (TRNSYS). To analyze comparative study of effects on the heating, cooling loads, and energy consumption of an LED lamp application, 2 types of LED lamp with low light power watt(LPW) 24W and high LPW 7.5W and a fluorescent lights(FL) with 37W are used respectively. Integrated building energy consumption decreased up to 3.2% when fluorescent lamps were replaced with LEDs. Thus, the high LPW of LED(7.5W) replaced with the same number of FL shows an effective energy saving and cost- effective luminary.

경화 및 냉각을 거친 LED 패키징 실리콘의 잔류응력에 대한 수치해석적 고찰 (A numerical study on the residual stress in LED encapsulment silicone after curing and cooling)

  • 송민재;김권희;강정진;김흥규
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.425-428
    • /
    • 2009
  • Silicone is recently used for LED chip encapsulment due to its good thermal stability and optical transmittance. To mold a solid-state silicone encapsulment, curing by mixing at elevated temperatures followed by cooling is necessary. As the silicone molding process is involved in healing and subsequent cooling, the thermal residual stress, which causes mechanical warpage or optical birefringence in the final silicone encapsulment, may be induced if there are non-uniformities in cured silicone material properties or encapsulment shape design. The prediction of residual stress is necessary to design a high-quality silicone molding process. Therefore, in the present paper, a numerical parametric study was attempted to evaluate the heating and cooling effects on the thermal residual stress induced in the cured silicone.

  • PDF

식물생장용 LED 램프의 적정 수냉조건 및 열교환량 분석 (Analysis of Optimum Water Cooling Conditions and Heat Exchange of LED Lamps for Plant Growth)

  • 박종호;이재수;김동억;김용현
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.334-341
    • /
    • 2011
  • This study was conducted to compare the characteristics of heat dissipated from LED lamps with water cooling method and natural cooling method in a closed-type plant production system (CPPS) and to determine the optimum water temperature and flow rate for LED lamps with water cooling method. The experiments were performed in CPPS maintained at temperature of $24^{\circ}C$ and humidity of 70%. As compared to the LED lamps operated at water temperature of $22.5{\pm}1.2^{\circ}C$ and flow rate of $1,521{\pm}3.3\;mL{\cdot}min^{-1}$, air temperature under LED lamps with natural cooling was approximately increased by $1^{\circ}C$ and photosynthetic photon flux was decreased by $10{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. PPF illuminated from LED lamps was affected by forward voltage varied by the surface temperature of LED lamps. Forward voltage of LED lamps was decreased with increasing surface temperature and then PPF was proportionately decreased. Five levels ($14^{\circ}C,\;17^{\circ}C,\;20^{\circ}C,\;23^{\circ}C,\;26^{\circ}C$) of water temperature and three levels ($500\;mL{\cdot}min^{-1}$, $1,000\;mL{\cdot}min^{-1}$, $1,500\;mL{\cdot}min^{-1}$) of flow rate were provided to analyze the change of surface temperature and heat exchange of LED lamps. Heat exchange was increased with decreasing water temperature and increasing flow rate. At flow rate of $1,000-1,500\;mL{\cdot}min^{-1}$ and water temperature of 22.0-$22.6^{\circ}C$, surface temperature of LED lamps can be approached to $24^{\circ}C$ that was almost same as air temperature in CPPS. The calorific value generated from LED lamps used in the study was estimated to be $103.0\;kJ{\cdot}h^{-1}$.

KNU 식물공장의 냉난방 에너지 부하 해석에 관한 연구 (A Study on the Heating and Cooling Energy Load Analysis of the KNU Plant Factory)

  • 이찬규;김우태
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1419-1426
    • /
    • 2012
  • KNU 식물공장 모델의 냉난방 에너지 부하를 DesignBuilder를 이용하여 해석하였다. 실내설정온도, LED 보광주기, LED 보광량, 유리외피의 구조에 따른 에너지 소모량을 분석하였다. LED 보광이 없는 식물공장의 실내설정온도를 상추의 적정 생육온도인 $20^{\circ}C$를 중심으로 $15^{\circ}C$, $25^{\circ}C$로 변화시키면서 일정온도로 유지하는데 필요한 연간 냉난방부하를 분석하였다. $15^{\circ}C$일 때 냉방부하, $25^{\circ}C$일 때 난방부하가 가장 크게 나타났다. 상추 재배에 필요한 LED 보광 적용 시 난방부하는 감소하지만 냉방부하가 약 6배 증가한다. 또한 LED 보광 시 주간보다는 야간보광이 냉난방부하 감소에 유리한 결과를 주었다. 식물공장 외피가 냉난방부하에 미치는 영향을 비교하기 위하여 다섯 가지 종류의 외피를 적용하여 계산하였다. 이중창호의 열관류율이 작을수록 식물공장의 난방부하는 감소하고 냉방부하는 증가하였다. 재배할 작물의 적정생장온도 설정, LED 및 재배설비의 내부발열량에 따른 적절한 외피선택, 다양한 패시브 및 액티브 에너지 절감기술의 적용으로 냉방부하를 감소시키는 것이 식물공장 운영에 중요한 요소로 판단된다.

담금 냉각되는 LED 조명엔진의 열특성에 대한 연구 (Study on the Thermal Behavior of Immersion Cooled LED Lighting Engines)

  • 김경준
    • 동력기계공학회지
    • /
    • 제18권3호
    • /
    • pp.87-92
    • /
    • 2014
  • This study is aimed at investigating the thermal behavior of immersion-cooled high power LED lighting engines. 3D CFD models have been generated for the numerical analysis. Five cases in terms of the configuration of LED chips have been explored for various passive cooling conditions of the lighting engine, i.e., the natural air convection with a lens, the natural air convection without a lens, the deionized water-immersion cooling condition with a lens. The numerical study reveals that the deionized water-immersion cooled lighting engine has nearly twice better thermal performance than the natural air convection cooled lighting engine containing a lens. The investigation has also demonstrated that the four chips configuration has the better thermal performance than the single chip configuration.

고출력 백색 LED 램프의 구동조건에 따른 온도 및 광 특성 평가 (Evaluation of the Device Temperature and Optical Characteristics in High Power White LED Lamp by Driving Condition)

  • 윤장희;염정덕
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.33-38
    • /
    • 2011
  • In this paper, the effect of pulse current and generated heat on characteristics of the LED is measured and evaluated. For experiments, the LED driving circuit and digital logic which determines period and duty ratio of lighting are designed. At rated current, the temperature and optical characteristics of the LED with change in duty ratio and period are compared, and those of the LED with change in duty ratio and existence of cooling fan are also compared at constant average current. As a result, frequency does not affect device temperature and optical characteristic of the LED but duty ratio does. Also, the cooling fan is less effective on those of the LED at rated current.

RF통신을 이용한 LED 조명의 온도제어 (Temperature Control for LED Lamps Using RF Communication)

  • 최형식;신희영;오지윤;이상섭
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.759-765
    • /
    • 2012
  • In this paper, a temperature control for LED (light emitting diode) lamp using a cooling fan is studied. An efficient temperature control scheme for the LED lamp using the fan wind at the lowest sound noise is studied. For the study, after measurement of the minimum sound noise of the fan and related temperature of the LED lamp through tests, experiments on temperature control of the LED lamp using the fan with various size of heat sinks was performed. To reduce the fan sound noise, a method of reducing the operation time with optimal size of the heat sink was studied. Also, a control of LED lamps using RF communication was studied.