• Title/Summary/Keyword: LED 램프

Search Result 193, Processing Time 0.025 seconds

Development of Smart Garden Control System Using Probabilistic Filter Algorithm Based on SLAM (SLAM기반 확률적 필터 알고리즘을 이용한 스마트 식물 제어 시스템 개발)

  • Lee, Yang-Weon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.3
    • /
    • pp.465-470
    • /
    • 2017
  • This paper designs and implements a smart garden system using probabilistic filter algorithm using SLAM that can be used in apartment or veranda. To do this, we used Arduino and environtal sensors, which are open hardware controllers, and designed to control and observe automatic water supply, lighting, and growth monitoring with three wireless systems (Bluetooth, Ethernet, WiFi). This system has been developed to make it possible to use it in an indoor space such as an apartment, rather than a large-scale cultivation system such as a conventional plant factory which has already been widely used. The developed system collects environmental data by using soil sensor, illuminance sensor, humidity sensor and temperature sensor as well as control through smartphone app, analyzes the collected data, and controls water pump, LED lamp, air ventilation fan and so on. As a wireless remote control method, we implemented Bluetooth, Ethernet and WiFi. Finally, it is designed for users to enable remote control and monitoring when the user is not in the house.

Chlorophyll Fluorescence, Chlorophyll Content, Graft-taking, and Growth of Grafted Cucumber Seedlings Affected by Photosynthetic Photon Flux of LED Lamps (LED 램프의 광합성유효광양자속이 오이접목묘의 엽록소형광, 엽록소함량, 활착 및 생장에 미치는 영향)

  • Kim, Hyeong Gon;Lee, Jae Su;Kim, Yong Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.231-238
    • /
    • 2018
  • Chlorophyll fluorescence, chlorophyll content, graft-taking and growth of grafted cucumber seedlings as affected by photosynthetic photon flux (PPF) of LED lamps were analyzed in this study. Four PPF levels, namely 25, 50, 100, $150{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ were provided to investigate the effect of light intensity on the chlorophyll fluorescence, chlorophyll content, graft-taking and growth of grafted cucumber seedlings. Air temperature, relative humidity, and photoperiod for graft-taking were maintained at $25^{\circ}C$, 90%, $16h{\cdot}d^{-1}$, respectively. Maximum quantum yield (Fv/Fm) of rootstock as affected by PPF was found to be 0.84-0.85 and there was no significant change in Fv/Fm. Even though Fv/Fm of scion measured at 2 days after grafting was lowered to 0.81-0.82, after then it gradually increased with increasing PPF. At 4 days after grafting, the chlorophyll content extracted from scion increased with increasing PPF. Graft-taking ratio of grafted cucumber seedlings was 90-95% as PPF was ranged from $25{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ to $100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. However, the graft-taking ratio of grafted seedlings healed under PPF of $150{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ was decreased to 80%. Maximum PPF measured required for smooth joining of rootstock and scion was assumed to be $100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. At healing stage of grafted cucumber seedlings, Fv/Fm of scion decreased and at least two days after grafting were required for rooting of grafted seedlings. Chlorophyll fluorescence response of rootstock and scion was linked to light irradiation. Therefore, it was concluded that physical environment including light and humidity during healing process of grafted seedlings should be controlled more precisely to facilitate root formation and to prevent scion from lowering Fv/Fm. Further studies are required to investigate the effects of root development and joining of vascular bundles of grafted seedlings on the chlorophyll content of scion.

Development of Portable Ground Control System for Operation of Unmanned Aerial Vehicle (무인항공기 운용을 위한 이동형 지상제어 시스템 개발)

  • Lee, Jang-Ho;Ryu, Hyeok;Kim, Jae-Eun;Ahn, Iee-Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.10
    • /
    • pp.127-133
    • /
    • 2004
  • This paper described development of the portable ground control system(PGCS) for unmanned aerial vehicle. In the design of GCS, it upload mission planning that aircraft has to perform and has to receive position, attitude, state, navigation information all about the aircraft. Aircraft states and trajectory are displayed using this system on line. The PGCS is composed of commercial notebook computer, RF modem for communication between aircraft and PGCS, input/output board, remote control receiver, switches and lamps. Performance of this system is verified by flight test of small unmanned aerial vehicle.

Nonthermal Sterilization of Pathogenic Escherichia coli by Intense Pulsed Light Using a Batch System (회분식 광펄스 처리에 의한 병원성 대장균의 비가열 살균)

  • Kim, Ae-Jin;Shin, Jung-Kue
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.81-86
    • /
    • 2015
  • Intense pulsed light (IPL), a nonthermal technology, has attracted increasing interest as a food processing technology. However, its efficacy in inactivating microorganisms has not been evaluated thoroughly. In this study, we investigated the influence of IPL treatment on the inactivation of Escherichia coli O157:H7 depending on light intensity, treatment time, and pulse number. Increased light intensity from 500 V to 1,000 V, raised the inactivation rate at room temperature. At 1000 V, the cell numbers were reduced by 7.1 log cycles within 120 s. In addition, increased pulse number or decreased distance between the light source and sample surface also led to an increase in the inactivation rate. IPL exposure caused a significant increase in the absorption at 260 nm of the suspending agent used in our experiments. This indicates that IPL-treated cells were damaged, consequently releasing intracellular materials. The growth of IPL-irradiated cells were delayed by about 5 h. The degree of damage to the cells after IPL treatment was confimed by transmission electron microscopy.

Multiple Visible Light Receiver Using A Flexible Solar Cell and Cds Cells (플렉시블 솔라셀과 Cds셀을 이용한 다중 가시광 수신기)

  • Lee, Seong-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.432-439
    • /
    • 2018
  • In this paper, an omnidirectional visible light detector was developed by making the detecting surface of a flexible solar cell in a cylindrical form, which has a uniform receiving pattern in the horizontal plane. This solar cell detector receives simultaneously multiple signal lights incident from different directions and provides electrical power to the ASK demodulator in the receiver. In experiments, time division transmission method was used to receive three signal lights incident from different directions to the solar cell detector. Each signal light was ASK modulated using a carrier of 40 kHz, and the synchronizing pulses required for time division transmission were generated by detecting the 120 Hz AC signal included in the indoor illumination lamp with Cds cells. This receiving structure is useful in constructing an $N{\times}1$ optical link in visible light communication.

Thermal Transfer Pixel Patterning by Using an Infrared Lamp Source for Organic LED Display (유기 발광 소자 디스플레이를 위한 적외선 램프 소스를 활용한 열 전사 픽셀 패터닝)

  • Bae, Hyeong Woo;Jang, Youngchan;An, Myungchan;Park, Gyeongtae;Lee, Donggu
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • This study proposes a pixel-patterning method for organic light-emitting diodes (OLEDs) based on thermal transfer. An infrared lamp was introduced as a heat source, and glass type donor element, which absorbs infrared and generates heat and then transfers the organic layer to the substrate, was designed to selectively sublimate the organic material. A 200 nm-thick layer of molybdenum (Mo) was used as the lightto-heat conversion (LTHC) layer, and a 300 nm-thick layer of patterned silicon dioxide (SiO2), featuring a low heat-transfer coefficient, was formed on top of the LTHC layer to selectively block heat transfer. To prevent the thermal oxidation and diffusion of the LTHC material, a 100 nm-thick layer of silicon nitride (SiNx) was coated on the material. The fabricated donor glass exhibited appropriate temperature-increment property until 249 ℃, which is enough to evaporate the organic materials. The alpha-step thickness profiler and X-ray reflection (XRR) analysis revealed that the thickness of the transferred film decreased with increase in film density. In the patterning test, we achieved a 100 ㎛-long line and dot pattern with a high transfer accuracy and a mean deviation of ± 4.49 ㎛. By using the thermal-transfer process, we also fabricated a red phosphorescent device to confirm that the emissive layer was transferred well without the separation of the host and the dopant owing to a difference in their evaporation temperatures. Consequently, its efficiency suffered a minor decline owing to the oxidation of the material caused by the poor vacuum pressure of the process chamber; however, it exhibited an identical color property.

A Study on Power Conversions of the Power Supply for Fire Safety Use (소방용 전원장치의 전력변환에 관한 연구)

  • Kwon, Seong-Pil;Lee, Jang-Won;Yook, Gil-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.462-465
    • /
    • 2011
  • 최근 우리나라에서는 대형 화재사고가 빈번히 발생함에 따라 그로 인한 재산 및 인명피해가 날로 증가하고 있는 실정이다. 따라서 건축물 내에서 화재가 발생할 경우 인명피해를 최소화하기 위하여 피난유도설비의 설치를 의무화하고 있다. 지금까지 일반적으로 가장 널리 사용되고 있는 피난유도설비로는 유도등이 있으며, 최근 들어 피난유도선의 설치도 다중이용업소를 중심으로 점차 확대되어가고 있는 추세이다. 피난유도설비는 평상시 이용되는 교류 상용전원에 의해서뿐만 아니라 비상시 이용되는 직류 비상전원에 의해서도 정상적으로 작동되어야 하기 때문에, 피난유도설비의 전원장치는 주어진 전원으로부터 주어지는 교류 또는 직류를 발광부에 맞게 일정한 전압과 주파수로 변환시켜주어야 한다. 실제로 LED(발광다이오드) 유도등은 상용전원으로부터 220V의 교류를 받아서 전원장치에서 정류변환을 통해 얻어지는 낮은 전압 24V의 직류를 이용하며, 대부분의 유도등 백라이트로 사용되고 있는 CCFL(냉음극형광램프)에는 상용전원으로부터 220V, 60Hz 교류를 인가받아 전원장치에서 정류 역변환을 통해 만들어진 100kHz의 고주파 교류가 공급된다. 더욱이 유도선의 전원장치에서는 상용전원 220V, 60Hz의 교류를 인가받아 정류 역변환 및 교류변환 과정을 차례로 거쳐 최종적으로 100V, 400Hz의 교류로 전환하여 TFEL(박막전계발광) 소자로 전송하게 된다. 한편, 상용전원이 차단된 상태에서도 전원장치는 마찬가지로 비상전원으로부터 24V의 직류를 공급받아 인버터를 통해 역변환 하여 100kHz의 고주파 교류를 만들어 주거나 추가적인 교류변환을 거쳐 100V, 400Hz의 교류로 변환시켜 내보낸다. 본 연구에서는 상대적으로 복잡한 전력변환 회로들을 포함하고 있는 유도선의 전원장치를 개선하여, 전원장치의 연결가능길이를 기존의 60m에서 최대 100m까지 연장시킴으로써, 터널이나 지하도와 같은 곳에서 특히 경쟁력을 갖게 될 것으로 기대된다.

  • PDF

무 수은 면광원에서의 가스 조성 변화에 따른 전기 광학 특성에 관한 연구

  • O, Byeong-Ju;Jeong, Jae-Cheol;Seo, In-U;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.431-431
    • /
    • 2010
  • 본 논문은 기존의 수은 형광 램프와 LED를 대체할 수 있는 무 수은 면광원의 방전 가스 조성 변화(He, Ne, Ar, Xe)에 따른 전기 광학 특성에 관한 연구이다.[1]~[4] 무 수은 면광원의 기본 구조는 그림 1과 같이 방전 공간 내에 유전체에 의해 방전 공간과 분리된 한 쌍의 평행한 전극으로 이루어져 있다. 그리고 방전 공간 내면에는 일정한 두께와 형상을 가지는 형광체가 도포되어 있고 주 전극의 반대 평판유리 외벽에 보조전극을 형성하였다. 방전을 발생시키기 위한 기본적인 구동 방법은 5~25kHz의 주파수와 $0.7{\sim}1.5{\mu}s$의 폭을 가지는 사각 펄스를 사용한다.[4] 그림 2는 Ne-Xe 가스를 기본으로 하여 He 첨가에 따른 전기 광학 특성을 보여준다. He 첨가량이 증가할수록 동작 전압이 높아지면서 방전 개시와 동시에 수축 방전으로 전이되는 형태를 보이며, 효율 또한 감소함을 보였다. 이것은 무 수은 면광원에서는 높은 He의 이차전자 방출 계수보다 He의 높은 이온화 에너지가 더 크게 작용하기 때문이라 생각된다. 그림 3은 Ne-Xe 가스를 기본으로 하여 Ar 첨가에 따른 특성을 보여준다. He과는 다르게 Ar 첨가량이 증가할수록 동작 전압 마진이 넓어진다. 그러나 동작 전압이 상승하고, 효율 역시 감소하는 단점이 있다. 이것은 Ar은 Ne에 비해 이온화 에너지가 낮지만 Ar-Xe 조합은 Penning 효과를 얻을 수 있는 혼합 가스가 아니며, Ar의 2차전자 방출 계수 역시 Ne에 비해 낮기 때문에 결과적으로 방전 전압은 상승하고 효율이 감소하는 결과를 보여준다. 그러므로 무 수은 면광원에서 낮은 구동 전압과 높은 휘도 효율을 얻기 위해서는 Ne-Xe 가스조건이 가장 적합한 가스 조건이다. 효율 개선을 위해서는 Ne-Xe 가스 조건에서 압력을 높이거나 높은 Xe 함량의 가스 조성비를 사용하여 자외선 발광원인 Xe 가스량을 높이는 방법이 가장 유리하다. 그림 4는 Ne-Xe 가스 조건에서 Xe 가스량을 높이면 효율이 증가하는 경향성을 보여준다. 가스 최적화 연구와 더불어 형광체 최적화 연구[5]를 통해서 Ne-Xe25% 100Torr 가스 조건에서 그림 5와 같은 19,000nit의 높은 휘도와 75lm/W의 고 효율 특성을 얻을 수 있었다.

  • PDF

An Experimental Study on Geotextile Effects as Reinforcement and Vertical Drain Materials (보강재(補强材) 및 배수촉진재(排水促進材)로서 Geotextile 의 효과(効果)에 관한 실험적(實驗的) 연구(硏究))

  • Kim, Soo Il;Yoo, Ji Hyeung;Cho, Sam Deok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.4
    • /
    • pp.39-47
    • /
    • 1982
  • Geotextile effects as reinforcement and vertical drain materials are studied through the laboratory model embankments on weak clays. The experiments are carried out in four stages; no woven fabrics between clay-crushed stone boundary, fabrics between boundary with no initial pretensioning of fabrics, and fabrics between boundary with two different initial pretensionings of fabrics. In all stages, vertical drains utilizing non-woven fabrics are installed in the clay layer in square pattern to accelarate the consolidation. The experimental model has plane dimensions of $32cm{\times}330cm$. The height for the clay container is 60 cm. The 47 cm height of crushed stone embankment is constructed over the 50 cm deep clay layer. The time dependent pore pressures are measured utilizing the 8 piezometers installed symmetrically on both sides of the wall at different heights. The time dependent deformations are measured utilizing the LED indicating lamp matrix inserted in the crushed stone embankment and the dialgauges put on top of the clay layer where the crushed stones are not laid. The measurements are carried out for 10 days which is equivalent to the time required for the primary consolidation. Through the experimental study, an analytical procedure is developed to predict the time dependent embankment settlement even if the top of the clay layer is reinforced with woven fabrics. This can be done through measuring the maximum pore pressures developed in the clay layer and comparing with the theoretical maximum pore pressures when no reinforcing fabrics are employed.

  • PDF

THE TEMPERATURE RISING IN PULP CHAMBER DURING COMPOSITE RESIN POLYMERIZATION (광중합 기전에 따른 복합레진 중합 시 치수강 내 온도변화)

  • Hwang, Dong-Hwan;Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.431-438
    • /
    • 2003
  • This study investigates pulp chamber temperature rise during composite resin polymerization by plasma arc(Group III : Flipo 3 sec, Group IV : Flipo 5 sec) and LED curing units(Group V : Lux-O-Max, 40 sec) as well as conventional halogen lamp curing units(Group I : VIP mode3, 20 sec, Group II : VIP mode6, 20 sec). The results are as follows : 1. All of the investigated pulp chamber temperature rises are lower than the boundary temperature could result in irreversible damage to the pulpal tissue ($5.5^{\circ}C$). 2. In the group II, it is found the significantly higher pulp chamber temperature rise than any other groups(p<0.05). 3. In the group of composite resin light-cured with VIP, it is found the significantly higher pulp chamber temperature rise in the group II than group I(p<0.05). 4. In the group of composite resin light-cured with Flipo, it is found the significantly higher pulp chamber temperature rise in the group IV than group III (p<0.05). 5. In the case of comparing VIP and Flipo, group II is significantly higher pulp chamber temperature rise than group III, IV(p<0.05), and group IV is significantly higher pulp chamber temperature rise than group I(p<0.05), and it does not significantly differ between group I and III. 6. In the group of composite resin light-cured with Lux-O-Max, it is found the significantly lower pulp chamber temperature rise than any other groups (p<0.05).

  • PDF