• Title/Summary/Keyword: LC-based sensors

Search Result 8, Processing Time 0.023 seconds

High-Contrast Imaging of Biomolecular Interactions Using Liquid Crystals Supported on Roller Printed Protein Surfaces

  • Park, Min-Kyung;Jang, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.10
    • /
    • pp.3269-3273
    • /
    • 2012
  • In this study, we report a new method for the high contrast imaging of biomolecular interactions at roller printed protein surfaces using thermotropic liquid crystals (LCs). Avidin was roller printed and covalently immobilized onto the obliquely deposited gold surface that was decorated with carboxylic acid-terminated self-assembled monolayers (SAMs). The optical response of LCs on the roller printed film of avidin contrasted sharply with that on the obliquely deposited gold surface. The binding of biotin-peroxidase to the roller printed avidin was then investigated on the obliquely deposited gold substrate. LCs exhibited a non-uniform and random orientation on the roller printed area decorated with the complex of avidin and biotin-peroxidase, while LCs displayed a uniform and planar orientation on the area without roller printed proteins. The orientational transition of LCs from uniform to non-uniform state was triggered by the erasion of nanometer-scale topographies on the roller printed surface after the binding of biotin-peroxidase to the surface-immobilized avidin. The specific binding events of protein-receptor interactions were also confirmed by atomic force microscopy and ellipsometry. These results demonstrate that the roller printing of proteins on obliquely deposited gold substrates could provide a high contrast signal for imaging biomolecular interactions using LC-based sensors.

Imaging the Enzymatic Reaction of Urease Using Liquid Crystal-Based pH Sensor

  • Hu, Qiong-Zheng;Jang, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4377-4381
    • /
    • 2011
  • In this study, real-time and label-free methods for monitoring the enzymatic reaction of urease, which releases ammonia through the hydrolysis of urea in an aqueous solution, were developed using a liquid crystal (LC)-based pH sensor. Nematic liquid crystal 4-cyano-4'-pentylbiphenyl (5CB), doped with 4'-pentyl-biphenyl-4-carboxylic acid (PBA), exhibited a shift in optical appearance from bright to dark when it was in contact with ammonia generated from the enzymatic reaction between urease and urea. This optical change was attributed to the anchoring transitions of LCs caused by hydrophobic interactions between the tails of deprotonted PBA ($PBA^-$) molecules and the LCs at the aqueous/LC interface. This novel technique holds great promise for the sensitive detection of urease along with its substrates and inhibitors.

Real-time Blood Pressure Monitoring in Porcine Tibial Artery Using LC Resonant Pressure Sensor (LC 공진형 압력 센서를 이용한 돼지 경골 동맥의 실시간 혈압 측정)

  • Choi, Won-Seok;Kim, Jin-Tae;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.445-450
    • /
    • 2012
  • We have developed an implantable wireless sensor for real time pressure monitoring of blood circulation system. MEMS (micro-electro-mechanical system) technology was adopted as a sensor development method. The sensor is composed of photolithographically patterned inductors and a distributed capacitor in gap between the inductors. A resulting LC resonant system produces its resonant frequency in range of 269 to 284 MHz at 740 mmHg. To read the resonant frequency changed by blood pressure variation, we developed a custom readout system based on a network analyzer functionality. The bench-top testing of the pressure sensors showed good mechanical and electrical functionality. A sensor was implanted into tibial artery of farm pig, and interrogated wirelessly with accurate readings of blood pressure. After 45 days, the sensor's electrical response and histopathology were studied with good frequency reading and biocompatibility.

LCD Embedded Hybrid Touch Screen Panel Based on a-Si:H TFT

  • You, Bong-Hyun;Lee, Byoung-Jun;Lee, Jae-Hoon;Koh, Jai-Hyun;Takahashi, Seiki;Shin, Sung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.964-967
    • /
    • 2009
  • A new hybrid-type touch screen panel (TSP) has been developed based on a-Si:H TFT which can detect the change of both $C_{LC}$ and photo-current. This TSP can detect the difference of $C_{LC}$ between touch and no-touch states in unfavorable conditions such as dark ambient light and shadows. The hybrid TSP sensor consists of a detection area which includes one TFT for photo sensing and two TFTs for amplification. Compared to a single internal capacitive TSP or an optical sensing TSP, this new proposed hybrid-type TSP enables larger sensing margin due to embedding of both optical and capacitive sensors.

  • PDF

Real-time Multi-device Control System Implementation for Natural User Interactive Platform

  • Kim, Myoung-Jin;Hwang, Tae-min;Chae, Sung-Hun;Kim, Min-Joon;Moon, Yeon-Kug;Kim, SeungJun
    • Journal of Internet Computing and Services
    • /
    • v.23 no.1
    • /
    • pp.19-29
    • /
    • 2022
  • Natural user interface (NUI) is used for the natural motion interface without using a specific device or tool like a mouse, keyboards, and pens. Recently, as non-contact sensor-based interaction technologies for recognizing human motion, gestures, voice, and gaze have been actively studied, an environment has been prepared that can provide more diverse contents based on various interaction methods compared to existing methods. However, as the number of sensors device is rapidly increasing, the system using a lot of sensors can suffer from a lack of computational resources. To address this problem, we proposed a real-time multi-device control system for natural interactive platform. In the proposed system, we classified two types of devices as the HC devices such as high-end commercial sensor and the LC devices such astraditional monitoring sensor with low-cost. we adopt each device manager to control efficiently. we demonstrate a proposed system works properly with user behavior such as gestures, motions, gazes, and voices.

Synthesis of Novel Fluorescent Dye Based on Fluorescein

  • Hwang, Ji-Yong;Son, Young-A
    • Textile Coloration and Finishing
    • /
    • v.26 no.3
    • /
    • pp.272-276
    • /
    • 2014
  • The functional materials have been developed as a promising research topic toward the end uses for organic materials and applications. In this study, fluorescein based dye was synthesized by three step reaction. We have designed and synthesized the colorimetric dye through the reactions of fluorescein and methoxy group and ethylene diamine and squaric acid. The structure of the non-fluorescent spirolactam was elucidated by $^1H$-NMR, LC-Mass and FT-IR analyzes. Further studies are in progress to understand the effects of various substituent during the recognition process and to develop fluorescein based sensors for cations or anions.

One-Cycle Control Strategy with Active Damping for AC-DC Matrix Converter

  • Liu, Xiao;Zhang, Qingfan;Hou, Dianli
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.778-787
    • /
    • 2014
  • This study presents an input filter resonance mitigation method for an AC-DC matrix converter. This method combines the advantages of the one-cycle control strategy and the active damping technique. Unnecessary sensors are removed, and system cost is reduced by employing the grid-side input currents as feedback to damp out LC resonance. A model that includes the proposed method and the input filter is established with consideration of the delay caused by the actual controller. A zero-pole map is employed to analyze model stability and to investigate virtual resistor parameter design principles. Based on a double closed-loop control scheme, the one-cycle control strategy does not require any complex modulation index control. Thus, this strategy can be more easily implemented than traditional space vector-based methods. Experimental results demonstrate the veracity of theoretical analysis and the feasibility of the proposed approach.

Development of Pressure Sensor on Polymer Substrate for Real-time Pulse and Blood Pressure Measurements (실시간 맥박 및 혈압 측정을 위한 폴리머 기판 압력센서 개발)

  • Kim, Jin-Tae;Kim, Sung Il;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.669-676
    • /
    • 2013
  • In this study, we introduce a polymer(polyimide) based pressure sensor to measure real-time heart beat and blood pressure. The sensor have been designed with consideration of skin compatibility of material, cost effectiveness, manufacturability and wireless detection. The designed sensor was composed of inductor coils and an air-gap capacitor which generate self-resonant frequency when electrical source is applied on the system. The sensor was obtained with metalization, etching, photolithography, polymer adhesive bonding and laser cutting. The fabricated sensor was shaped in circular type with 10mm diameter and 0.45 mm thickness to fit radial artery. Resonant frequencies of the fabricated sensors were in the range of 91~96 MHz on 760 mmHg pressurized environment. Also the sensor has good linearity without any pressure-frequency hysteresis. Sensitivity of the sensor was 145.5 kHz/mmHg and accuracy was less than 2 mmHg. Real-time heart beat measurement was executed with a developed hand-held measurement system. Possibility of real-time blood pressure measurement was showed with simulated artery system. After installation of the sensor on skin above radial artery, simple real blood pressure measurement was performed with 64 mmHg blood pressure variation.