• Title/Summary/Keyword: LC-MS/MS method

Search Result 605, Processing Time 0.027 seconds

Improved HPLC-UV method for determination of five synthetic dyes in Typha orientalis

  • Ko, Kyung Yuk;Choi, Eun Young;Jeong, Se Hee;Paek, Ock jin;Lee, Chan;Heo, Huijin;Oh, She-Wook;Lee, Chulhyun;Kang, Juhye;Cho, Sooyeul
    • Analytical Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.160-171
    • /
    • 2021
  • Synthetic azo dyes are used extensively in herbal medicines to render the medicines more visually attractive to consumers. This study developed and validated a rapid high-performance liquid chromatography (HPLC) method to determine whether synthetic colorants such as Tartrazine, Auramine O, Metanil yellow, Sunset yellow, and Orange II are used extensively in Typha orientalis. To increase the recovery of the synthetic dyes, this method employed containing 50 mM ammonium acetate in 70 % methanol at first extraction and 100 mM HCl in 70 % methanol at second extraction. Five synthetic pigments in Typha orientalis were separated by gradient elution with a mobile phase consisting of acetonitrile and 50 mM ammonium acetate in distilled water at ultra-violet (UV) detection 428 nm or 500 nm. Additionally, this study established the liquid chromatography tandem mass spectrometry (LC-MS/MS) method to confirm positive samples suspected by HPLC results. The HPLC-UV method had good linearity, indicating r2> 0.999. The recoveries of the samples spiked with three different concentration ranged from 73.8~91.5 %, and relative standard deviation values indicated 0.2~5.2 %. The established LC-MS/MS could successfully identify the synthetic pigments in herbal medicine samples. The study demonstrates that Typha orientalis adulterated by yellowish synthetic dyes can be successfully distinguished when using the HPLC-UV method.

Validation of Analytical Method for Male Sex Hormone Monitoring in Urine due to the Chemical Castration (성충동약물치료 시행에 따른 소변 중 남성호르몬의 분석법 확립)

  • Jeong, Sujin;Baeck, Seungkyung;Park, Sunhye;Son, Kkonnip;Park, Yonghoon;Lee, Sangki
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.330-336
    • /
    • 2013
  • "The Act on Medication Treatment of Sexual Impulse of Sex Offenders" known as chemical castration has been effective since July 2011 in Korea. According to the law, monitoring of male sex hormone in urine is enforced to request National Forensic Service more than once a month after injection of medicine designed to reduce sex impulse. We established a rapid and sensitive method for the monitoring of testosterone (T) and epitestosterone (E) in human urine by liquid chromatography with tandem mass spectrometry (LC-MS/MS). Three mL of urine was pretreated by solid-phase extraction for purification and performed enzymatic hydrolysis. The pretreated samples were extracted twice with 2 ml of ethyl acetate and n-hexane (2 : 3). The separation was applied on Thermo Hypersil GOLD C18 column ($1.9{\mu}m$, $100{\times}2.1mm$). A gradient elution of methanol and water of 0.1% formic acid were used as mobile phase and the retention time was less than 10 min. LC-MS/MS system coupled with an electrospray ionization source was performed in multiple reaction monitoring mode. The transitions of the analytes executed as following: m/z $289{\rightarrow}97$, 109 for T and E, m/z $292{\rightarrow}109$ for $T-d_3$ and $E-d_3$ as internal standards. The validation results of the method were satisfactory. The limits of detection were 0.05 ng/ml and the limits of quantification were 0.1 ng/ml. This method was successfully applied to real human urine sample. The developed method will be useful for monitoring T/E ratio in urine of sex offenders.

Development of Highly Sensitive Analytical Method for Evaluation of Evening Primrose Oil's Enhancing Effect in Prostaglandin E1(OP 1206) Biosynthesis

  • Lee, Sung-Hoon
    • Journal of People, Plants, and Environment
    • /
    • v.21 no.6
    • /
    • pp.485-492
    • /
    • 2018
  • This study aimed to develop and validate highly sensitive determination method of a prostaglandin ($PGE_1$, OP 1206) in human plasma by LC-MS/MS using column switching. Plasma stored at $-30^{\circ}C$ and treated with methanol effectively inhibited interferences synthesized post-sampling. Samples were added with internal standard and were separated by reversed-phase HPLC with a cycle time of 30min. The method was selective for OP 1206 and the regression models, based on internal standard, were linear across the concentration range 0.5-50 pg/mL with the limit of quantification of 0.5 pg/mL (limit of quantitation, LOQ) for OP 1206. The calibration curve of OP 1206 standards spiked in five individual plasma samples was linear ($r^2=0.9999$). Accuracy and precision at the concentrations of 0.5, 1.5, 5.0 and 40 pg/mL, and at the lower LOQ of 0.5 pg/mL were excellent at 20%. OP120 < 6 was stable in plasma samples for at least 24 hours at room temperature, 24 hours frozen at $-70^{\circ}C$, 24 hours in an auto sampler at $6^{\circ}C$, and for two freeze/unfreezing cycles. The validated determination method successfully quantified the concentrations of OP 1206 in plasma samples from simulated administrating a single $5{\mu}g$ OP 1206 formulation. Thus, this novel LC-MS/MS technique for drug separation, detection and quantitation is expected to become the standard highly-sensitive detection method in bioanalysis and to be applied to many low dose pharmaceutical products.

Determination of Residual Erythromycin Antibiotic in Fishery Products by Liquid Chromatography-electrospray Ionization Mass Spectrometry (LC-MS/MS를 이용한 어류 및 갑각류의 잔류 Erythromycin 항생제 분석)

  • Jo, Mi-Ra;Mok, Jong-Soo;Lee, Doo-Seog;Kim, Min-Jung;Kim, Poong-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.1
    • /
    • pp.15-19
    • /
    • 2009
  • A simple and sensitive method for erythromycin quantification by liquid chromatography electrospray mass spectrometry (LC-MS/MS) in fishery products was developed. Samples were extracted by liquid-liquid extraction using 70% acetonitrile. Lipids were removed by acetonitrile saturated hexane. LC separation was performed on a Shiseido UG C-18 column ($150\;mm{\times}2.0\;mm$ internal diameter.) with a gradient system of 0.2% acetic acid-acetonitrile containing 0.2% acetic acid as a mobile phase at flow rate of 0.2 mL/min. The mass spectrometer was operated in selected reaction monitoring with positive electro-spray interface. Transitions were monitored a m/z $734{\to}577$ and $734{\to}158$, with m/z $734{\to}577$ chosen for quantification. Recovery of erythromycin from fish and shrimp fortified at the 10 ng/mL, 50 ng/mL and 100 ng/mL were 91.6-109.4%, 84.4-111.2% and 98.8-109.6% with high precision, respectively. Limits of quantification and limits of detection of erythromycin in both fish and shrimp were 10.0 ng/mL and 1.0 ng/mL, respectively. This analysis method for erythromycin has been proposed for registration in the Korean Official Methods of Food Analysis and has been utilized for fishery products analysis by the Korea Food and Drug Adminstration and the National Fisheries Products Quality Inspection Service.

An analytical method of heterocyclic amines by LC/MS (LC/MS를 이용한 heterocyclic amines의 분석법)

  • Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.115-123
    • /
    • 2007
  • The heterocyclic amines (HAs) are a family of mutagenic/carcinogenic chemicals formed from the cooking of muscle meats such as beef, meat, fowl, and fish. A major draw back in the analysis of HAs from foods is their very low level of concentration (ng/g) and a number of matrix interferences in samples. Solid-phase extraction (SPE) is one of the procedures widely used for the extraction and purification of HAs in food samples. In this study, several SPE procedures of HAs determination were performed. Recoveries of the HAs were obtained from comparing a matrix such as a standard methanolic solution and pre-cooked meat extracts. Recovery values were ranging between 25.3 and 93.0 % at a concentration of 25.0 ng/g. HAs were determined with high sensitivity by micro-HPLC (${\mu}$-HPLC) analysis with electrospray ionization mass spectrometry (ESI-MS). Another developed method, which is freezing filtration method, shows better extraction recoveries and good precisions. The established method will be applicable to monitoring of heterocyclic amines from the cooked meat.

Establishment of a library of fragments for the rapid and reliable determination of anabolic steroids by liquid chromatography-quadrupole time of flight-mass spectrometry

  • Do, Jung-Ah;Noh, Eunyoung;Yoon, Soon-Byung;Choi, Hojune;Baek, Sun-Young;Park, Sung-Kwan;Lee, Sang-Gyeong
    • Analytical Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.10-19
    • /
    • 2017
  • Anabolic steroids have similar structures to testosterone, both of which promote the growth of muscle mass and increase strength. However, the side effects of anabolic steroid use may lead to heart attacks or strokes. Additionally, the excessive use of steroids inhibits the production of the sex hormones in the body via a negative feedback loop, which results in testicular atrophy in males and amenorrhea in females. Currently, the method of choice used to test for the presence of anabolic steroids is GC-MS. However, GC-MS methods require chemical derivatization of the steroid sample to ensure compatibility with the analytical method; therefore, analysis of many different samples is difficult and time consuming. Unlike GC-MS, the liquid chromatography-quadrupole-time of flight mass spectrometry (LC-Q-TOF-MS) method is suitable for many samples. Twenty-two different anabolic steroids were analyzed by LC-Q-TOF-MS with various collision energies (CE). Accurate mass spectral data were obtained using a Q-TOF-MS equipped with an electro-spray ionization source and operated in the positive MS/MS mode for several classes of steroids that are often the targets of testing. Based on the collected data, fragmentation pathways were carefully elucidated. The high selectivity and sensitivity of the LC-Q-TOF-MS instrument combined with these fragmentation pathways offers a new approach for the rapid and accurate screening of anabolic steroids. The obtained data from the 22 different anabolic steroids will be shared with the scientific community in order to establish a library to aid in the screening of illegal anabolic steroids.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Analysis of Ginsenosides by Thermospray LC/MS (열분무 LC/MS에 의한 인삼사포닌의 분석)

  • Park, Man-Ki;Park, Jeong-Hill;Hwang, Gwi-Seo;Lee, Mi-Young;Park, In-Jeong
    • Journal of Ginseng Research
    • /
    • v.19 no.2
    • /
    • pp.134-137
    • /
    • 1995
  • Ginseng saponins were analyzed by thermospray (TSP) LCMS method using ODS column and with acetonitrile/ammonium acetate solution. Optimal condition for TSP Lchfs was found as follows: capillary temperature: 33$0^{\circ}C$ repelled voltage: 200 V, and concentration of ammonium acetate: 0. 05 M. Panaxadiol and panaxatriol type saponins showed characteristic fragment ions. The calibration curve of ginseng saponin showed good linearity with a correlation coefficient of 0.99. Detection limits using selected ion monitoring (SIM) technique were improved by 10~200 times compared to conventional HPLCnnr detection method.

  • PDF

Keratanase II Digestion Accompanied with a Liquid Chromatography/Tandem Mass Spectrometry for Urinary Keratan Sulfate Quantitative Analysis

  • Chuang, Chih-Kuang;Lin, Hsiang-Yu;Wang, Tuen-Jen;Huang, Sung-Fa;Lin, Shuan-Pei
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.3 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: Mucopolysaccharidosis IV (MPS IV) is a disease characterized by deficient activity of N-acetylgalactosamine-6-sulfatase (GALNS) causing excessive lysosomal storage of keratan sulfate (KS). The identification of the relevant disaccharide units of KS after keratanase II digestion followed by liquid chromatography/tandem mass spectrometry detection (LC-MS/MS) is validated and applicable for the preliminary diagnosis of MPS IV. Methods: A total of 67 urine samples were collected and analyzed from 11 MPS IV patients comprising 10 MPS IVA and one MPS IVB patients, and 56 normal controls. Urinary glycosaminoglycan was first precipitated by the Alcian blue method followed by a digestion of keratanase II. The protonated species of the digested disaccharide products were detected by using multiple reaction monitoring experiment. Results: One particular disaccharide of KS was selected. The transition mass-to-charge (m/z) of the parent ion and its daughter ion after collision was $462.0{\rightarrow}97.0$, whereas the chondrosine used as an internal standard in this assay was m/z $353.9{\rightarrow}73.0$. The results corresponded well with the two-dimensional electrophoresis method. The quantities of urinary KS were significantly raised in confirmed MPS IV patients when comparing with those of normal controls ($170.2{\pm}81.1$ vs. $4.06{\pm}1.92{\mu}g/mL$). Conclusion: The LC-MS/MS method for MPS IVA determination is specific, sensitive, validated, and applicable for urinary KS quantification. This method can be used not only as a first-line biochemistry examination of MPS IVA, but also as an outcome survey after enzyme replacement therapy.