• Title/Summary/Keyword: LC-ESI MS

Search Result 214, Processing Time 0.036 seconds

Determination of Acetyl-L-carnitine in human plasma by LC-ESI/MS/MS

  • Jang, Moon-Sun;Park, Chang-Hun;Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Ye-Rie;Lee, Hee-Joo
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.217.3-217.3
    • /
    • 2003
  • Acetyl-L-carnitine, a physiological component of the L-carnitine family, has been proposed for treating Alzheimer's disease in pharmacological doses. Acetyl-L-carnitine and d3-acetylcarnitine (internal standard) were analyzed by electrospray ionization / tandem mass spectrometry (ESI/MS/MS) after derivatization to their butylesters through treatment with butanolic hydrogen chloride. Acetyl-L-carnitine produced a protonated precursor ion at m/z 260 and a corresponding product ion of m/z 85. Analytes were separated on a Capcell Pak C18 (2.0${\times}$150mm, 5 mm). (omitted)

  • PDF

Estimation of Impurities from Commercially Available Glycyrrhizin Standards by the HPLC/ESI-MS (HPLC/ESI-MS에 의한 글리시리진 표준품의 불순물 추정)

  • Myung, Seung-Woon;Min, Hye-Ki;Kim, Myungsoo;Kim, Young Lim;Park, Seong-Soo;Cho, Jung Hee;Lee, Jong-Chul;Cho, Hyun-Woo;Kim, Taek-Jae
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.504-510
    • /
    • 2000
  • The impurity profiles from the raw materials of glycyrrhizin were performed by the high performance liquid chromatography (HPLC)/electrospray ionization (ESI)- mass spectrometry (MS). For the HPLC experiment, a $C_{18}$($3.9{\times}300mm$, $10{\mu}m$) column was used and the mobile phase was acetic acid/$H_2O$ (1:10):acetonitrile=3:2 with a flow rate of 0.8 ml/min. The effluent was splitted into the ratio of 50:1 and went into the ESI-MS. Three to six impurities were found and informed of the identification of the structure of the impurities by ESI-MS. And the structures of impurities were suggested to a hydroxy-glycyrrhizin which is added with hydroxy group (-OH) in the glycyrrhetic acid moiety and a reduced-glycyrrhizin which the position of 12 of the glycyrrhetic acid moiety is reduced. The purities of the standard materials were about 90%.

  • PDF

Simultaneous analysis of residual glucocorticoids in egg by LC/MS/MS (LC/MS/MS를 이용한 계란 중 잔류 글루코코티코이드의 동시분석)

  • Jang, Mi-Ae;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.326-335
    • /
    • 2009
  • A specific analytical method able to identify and quantify traces of six glucocorticoids residues in eggs were developed. The extraction and clean-up parameters for simultaneous analysis were evaluated and HPLC and spectrometric conditions were also established. For determination of glucocorticoids, 5 g of egg was transferred into a test tube, adjusted pH 5.2 with acetate buffer and was $\beta$-glucuronidase/arylsulfatase from Helix pomatia added. The mixture was centrifuged and supernatant was extracted twice with 20 mL n-hexane. The extraction was performed with HLB cartridge using methanol, followed by clean-up with silica cartridge using methanol/ethyl acetate (4/6, v/v). The analytes were determined by HPLC/ESI-MS/MS operating in the negative ion mode. Validation studies with fortified egg samples for established method were performed. The result of method validation gave good efficiency, linearity, accuracy and precision. The correlation coefficients ($r^2$) of the calibration curves appeared to be higher than 0.99 in egg, indicating excellent linearity. LOD was ranged 0.09 to $0.17{\mu}g/kg$, and recoveries for most compounds were in the range of 55.7-69.8%. This method can be used to determine ${\mu}g/kg$ levels of glucocorticoids in eggs.

Determination of superdrol and its metabolites in human urine by LC/TOF-MS and GC/TOF-MS (LC/TOF-MS와 GC/TOF-MS를 이용한 인체 내 요시료 중 Superdrol과 그 대사체의 분석)

  • Choi, Hae-Min;Yum, Tae-Woo;Paeng, Gi-Jeong;Kim, Yun-Je
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.183-192
    • /
    • 2011
  • This study was done for the determination and excretion profile of superdrol and its metabolites in human urine using both liquid chromatography with electrospray ionization mass spectrometry and gas chromatography with mass spectrometry after trimethylsilylation. Superdrol and its two metabolites were detected in human urine after administration of superdrol to healthy volunteers. The intra-day recovery ranged 89.7-113.2%, accuracy ranged 91.8-113.8% and reproducibility ranged 0.2-6.8% and inter-day recovery ranged 89.3-104.1%, accuracy ranged 95.2-103.0%, reproducibility ranged 0.7-7.8%. We found that superdrol M1 was a hydration at C-3 and superdrol M2 was a hydroxylation at D-ring. Superdrol and two metabolites were excreted as their glucuronided fractions. The glucuro-/sulfa-conjugated ratio of superdrol, superdrol M1 and superdrol M2 were 0.02, 0.02, 0.01, respectively. The excretion studies showed that superdrol and two metabolites were reached 4.3 h after oral administration and superdrol and superdrol M1 were detected until 48 h in human urine.

Studies on mycotoxins using LC-MS/MS for the forage produced in Incheon

  • Ra, Do Kyung;Choi, Jae Yeon;Lee, Ju Ho;Nam, Ji Hyun;Lee, Jeoung Gu;Lee, Sung Mo
    • Korean Journal of Veterinary Service
    • /
    • v.42 no.3
    • /
    • pp.127-133
    • /
    • 2019
  • The purpose of this study was to investigate the contamination level of representative mycotoxins that have adverse effects on livestock by using LC-MS/MS method and to utilize the results as basic data for the establishment of quality control system for feed, and to provide information on production and storage. A total of nine mycotoxins, including aflatoxin $B_1$, aflatoxin $B_2$, aflatoxin $G_1$, aflatoxin $G_2$, ochratoxin A, fumonisin $B_1$, fumonisin $B_2$, deoxynivalenol (DON), zearalenone (ZEN) were simultaneously analyzed in LC-MS/MS under ESI positive mode. Fumonisin $B_1$ and fumonisin $B_2$ were detected from 3 cases of 75 forage produced in Incheon area, the detection rate was 4.0%. The detection concentration was 0.01~0.02 mg/kg, which was lower than the domestic recommended limit. Fumonisins were detected in a slightly different manner from the results of mycotoxin studies reported in Korea, which is attributed to the high temperature and dry summer weather of the year. The result of LC-MS/MS method performance of 9 mycotoxins, the recovery of DON was quite low as $41.53{\pm}3.91%$ that is not suitable for simultaneous analysis. This is probably due to that the extract solution used in this study was not suitable for the extraction of DON, along with the characteristics of a very dry forage. For the study of mycotoxins in Incheon area forage for the first time, further investigation is needed for the safe supply of livestock products.

A New Analytical Method for Erythromycin in Fish by Liquid Chromatography/Tandem Mass Spectrometry

  • Park, Mi-Jung;Park, Mi-Seon;Lee, Tae-Seek;Shin, Il-Shik
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.508-513
    • /
    • 2008
  • Erythromycin has been used to treat Streptococosis, Edwardsiel1osis, Vibriosis, Bacterial enteritis in the cultured fish. In this study, a rapid and effective erythromycin analysis method with new sample treatment protocol and liquid chromatography/tandem mass spectrometry (LC/MS/MS) system for fish products was developed. For the erythromycin extraction from fish muscle, the solvent mixture composed of 0.2% meta-phosphoric acid and methanol (6:4) showed good recovery rate, and the optimum extraction solvent volume was 20 mL. Erythromycin detection using LC/MS/MS were carried out under electro spray ionization (ESI) positive condition and erythromycin mass value 576.2 and 157.9. And the detection limit of the established method was 0.005 mg/kg in fish products. The recovery rate of the developed method applied to the fish species were as following, olive flounder, $87.6{\pm}5.0%$; black rockfish, $87.2{\pm}6.4%$; eel, $85.2{\pm}4.8%$; and rainbow trout, $86.0{\pm}6.2%$. In the established method in this study, the correlation of coefficient values ($R^2$) of erythromycin calibration curve (n=11) was 0.9998.

Simultaneous Determination and Occurrences of Pharmaceuticals by Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) in Environmental Aqueous Samples

  • Koo, So-Hyun;Jo, Cheon-Ho;Shin, Sun-Kyoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1192-1198
    • /
    • 2010
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in the aquatic environment. Many pharmaceuticals are not completely removed during wastewater treatment, leading to their presence in wastewater treatment effluents, rivers, lakes, and ground water. Here, we developed analytical methods for monitoring ten pharmaceuticals from surface water by LC/ESI-MS/MS. For sample clean-up and extraction, MCX (mixed cation exchange) and HLB (hydrophilic-lipophilic balance) solid-phase extraction (SPE) cartridges were used. The limits of detection (LOD) in distilled water and the blank surface water were in the range of 0.006 - 0.65 and 1.66 - 45.05 pg/mL, respectively. The limits of quantitation (LOQ) for the distilled water and the blank surface water were in the range of 0.02 - 2.17 and 5.52 - 150.15 pg/mL, respectively. The absolute recoveries for fortified water samples were between 62.1% and 125.4%. Intra-day precision and accuracy for the blank surface water were 2.9% - 24.1% (R.S.D.) and -16.3% - 16.3% (bias), respectively. In surface wastewater near rivers, chlortetracycline and acetylsalicylic acid were detected frequently in the range of 0.017 - 5.404 and 0.029 - 0.269 ng/mL, respectively. Surface water near rivers had higher levels than surface water of domestic treatment plants.

Development and validation of a selective and sensitive LC-MS/MS method for determination of misoprostol acid in human plasma: Application to bioequivalence study

  • Park, Yong Sun;Kim, Keun Nam;Kim, Ye Na;Kim, Jung Hwan;Kim, Jin Young;Sim, Soo Ji;Lee, Heon Soo
    • Analytical Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.17-25
    • /
    • 2015
  • A rapid, sensitive and specific method was developed and validated using electrospray ionization (ESI) tandem mass spectrometry (LC-MS/MS) for determination of misoprostol acid in human plasma. Misoprostol $acid-d_5$ was used as in internal standard (IS). The analyte and IS were extracted by simple one step solid phase extraction (SPE). Linearity in plasma was obtained over the concentration range 10~3000 pg/mL and lower limit of quantification (LLOQ) was identifiable and reproducible at 10 pg/mL. The intra- and inter-day precision values were below 9% and the accuracy was ranged from 93.81% to 102.02% at all four quality control samples. The method was has been successfully applied for routine assay to support pharmacokinetic study of misoprostol acid in human plasma after an oral administration of 0.4 mg misoprostol.

Rapid Determination of L-carnitine in Infant and Toddler Formulas by Liquid Chromatography Tandem Mass Spectrometry

  • Ahn, Jang-Hyuk;Kwak, Byung-Man;Park, Jung-Min;Kim, Na-Kyeoung;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.34 no.6
    • /
    • pp.749-756
    • /
    • 2014
  • A rapid and simple analytical method for L-carnitine was developed for infant and toddler formulas by liquid chromatography tandem mass spectrometry (LC-MS/MS). A 0.3 g of infant formula and toddler formula sample was mixed in a 50 mL conical tube with 9 mL water and 1 mL 0.1 M hydrochloric acid (HCl) to chemical extraction. Then, chloroform was used for removing a lipid fraction. After centrifuged, L-carnitine was separated and quantified using LC-MS/MS with electrospray ionization (ESI) mode. The precursor ion for L-carnitine was m/z 162, and product ions were m/z 103 (quantitative) and m/z 85 (qualitative), respectively. The results for spiked recovery test were in the range of 93.18-95.64% and the result for certified reference material (SRM 1849a) was within the range of the certificated values. This method could be implemented in many laboratories that require time and labor saving.

Detection, Identification and Characterization of In vitro GSH Metabolites Formed by 1-and 2-Bromopropane

  • Moon, Yoon-Soo;Kim, Eun-Kyung;Basnet, Arjun;Zhao, Long-Xuan;Kim, Dae-Ok;Kim, Nam-Hee;Chae, Whi-Gun;Jeong, Tae-Cheon;Lee, Eung-Seok
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.174.3-175
    • /
    • 2003
  • 1-and 2-Bromopropane were reported as the causative agents for reproductive toxicity and immunotoxicity. The glutathione (GSH) metabolites resulting from in vitro treatment of 1- and 2-bromopropane were detected, identified and characterized. For the facile identification, expected GSH metabolites rormed by 1- and 2-bromopropane were chemically synthesized as reference materials (positive controls) and characterized by $^1H$-NMR, $^13C$-NMR, HPLC and LC/MS/MS. The treatment of GSH and S-9 fraction with 1- or 2-bromopropane at a physiological condition (pH 7.4, $37^\times$) for 1hr produced GSH metabolites, which were identified by UV, HPLC and ESI LC/MS/MS analyses. (omitted)

  • PDF