• Title/Summary/Keyword: LAMP

Search Result 2,683, Processing Time 0.032 seconds

Development of The LED FDL for Replacing Fluorescent Lamp (형광램프대체용 LED FDL 개발)

  • Yang, Byong-Moon;Jang, Woojin;Cha, Jae-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.9-14
    • /
    • 2015
  • Due to the declining LED price and environment-friendly energy policies, CO2 emission reduction and energy-saving, the LED lighting industry is accelerating rapidly. In particular, the needs for LED lamp, replacing the existing fluorescent lamp without exchange luminaire or driver circuits, are also rapidly increasing. Therefore, replacement for T8 fluorescent lamp, LED T8 lamp was developed and standardized. However, except LED T8 lamps, other lamps' regulations or standards were not enacted. Also, the stability of fluorescent lamp substitutable LED lamp is low due to the difference in electrical characteristics and mismatch between the existing fluorescent lamp ballast and LED lamp. Therefore, many are struggling while developing fluorescent lamp substitutable LED lamp. In this paper describes the properties of existing fluorescent lamp ballasts and the considerations while developing fluorescent lamp substitutable LED lamp : demonstrating its validity by experiments the developed fluorescent lamp substitutable LED lamp prototype.

COMPARISON OF THE DECREE OF CONVERSION IN LIGHT-CURED COMPOSITE RESIN CURED BY HALOGEN AND PLASMA XENON ARC LAMP CURING UNIT (Halogen lamp 광조사기와 Plasma xenon arc lamp 광조사기에 의한 광중합 복합레진의 중합률 비교)

  • Lee, Young-Jun;Jeong, Byung-Cho;Choi, Nam-Ki;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.328-336
    • /
    • 2002
  • Recently, new light curing unit utilizing the plasma xenon arc lamp is introduced. This curing unit is operated at relatively high intensity, so shortening the curing time significantly. The aim of this experiment was to estimate curing capability of plasma xenon arc lamp curing unit compared to traditional halogen lamp curing unit. Degree of conversion was evaluated by Raman spectroscopy after irradiation of specimens with halogen lamp curing unit(Optilux 150, Demetron, USA) for 20s, 40s, 60s and plasma xenon arc lamp curing unit(flipo, Lokki, France) for 2s, 3s, 6s. The results showed that strong light intensity of plasma xenon arc lamp curing unit did not compensate for short exposure time completely. So, Multi-layered curing within 2mm thickness and additional exposure time is recommanded when light-cured composite resin is polymerized with plasma xenon arc lamp curing unit.

  • PDF

Aging-Time Dependence of Color Rendering Index of a LED Lamp for Lighting (조명용 LED 램프의 사용 시간에 따른 연색지수 특성변화)

  • Son, Minwoo;Lee, Duck Hee;Seo, Jung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.1-6
    • /
    • 2014
  • We measured color rendering index(CRI) of a LED lamp for lighting for aging-time. We chose bulb type white LED lamp six samples and halogen lamp one sample and applied 220V, 60Hz to all the samples for 1,000hours at ordinary temperature. The CRI was measured every 20hours and the CRI change of the LED lamp was compared with the halogen lamp's CRI change. As time goes, efficiency of the halogen lamp decreased and the CRI maintained uniformly. The other hand, efficiency of the LED lamp decreased but the CRI increased. The CRI of the LED lamp has been stabilized since 600hours. The CRI change of the LED lamp was analyzed with a spectrum, color coordinate and color temperature.

The Analysis on the Electric Potential Distribution of Dry and Submerged Condition by Electric Leakage in Street Lamp (가로등설비 누전시 건조상태와 침수상태에 대한 전위분포 분석)

  • Hon, Sung-Ho;Park, Sang-Tea;Kim, Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.44-50
    • /
    • 2008
  • This paper presents study on the electric potential distribution when have a short in street lamp. In order to measure electric potential testing ground is built in. A experiment is conducted to simulate dry and submerged situation of street lamp. The street lamp is leaked by artificial means. And electric potential is measured in grounded street lamp and street lamp alone. The results show that touch voltage of grounded street lamp is possible more high than street lamp alone. And the electric shock hazard is high because high electric potential is distributed near submerged street lamp. Also if street lamp is submerged ground is not useful to decrease electric shock hazard.

A study on the accommodation of common LED to shipboard (육상용 LED 램프의 선박 적응력에 관한 연구)

  • Jeong, Ji-Hyun;Park, Hwan-Chul;Kim, Yong-Joo;Seo, Sang-Do;Han, Seung-Jae;Kim, Min-Sok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.503-508
    • /
    • 2010
  • Common LED (Light Emitting Diode) lamp has many advantages to compare with fluorescent lamp, long life and no pollution matter like the mercury. The LED lamp is a good light source especially for shipboard lighting because of its compact structure which prevents explosion and shock. Also, low maintenance cost is expected due to its longer life time in comparison with conventional lamps. The LED lamp, however, need some estimates that change of voltage and frequency, vibration, moisture on board to definite accommodation of the LED lamp to shipboard. The purpose of this study is to compare physical properties of a fluorescent lamp with one of the common LED lamp so as to analyze accommodation of common LED lamp on board. This study was carried out in two stages. First, temperature, humidity of illumination, voltage, electric current, frequency and electric power were measured by using experimental equipments. Second, a comparative analysis of consumption electric power, annual oil charge, annual CO2 emission and lamp life time, etc of the fluorescent lamp and common LED one was made. As a result of the study, the consumption electric power of fluorescent lamp was 50% higher than one of the common LED lamp. As a result of measuring life time, it was found that life time of common LED lamp was more about 3.5 fold than one of the fluorescent lamp. Considering these results, it's thought that common LED lamp is verified that energy saving is possible and using is possible as substitute for fluorescent lamp on board.

Comparison of the Effects of Luminous Lamp, and Nonluminous Lamp Radiation on Experimental Pain Threshold Sensitivity (발광·무광 적외선등 조사가 실험적 통증역치에 미치는 효과 비교)

  • Lim, In-Hyuk;Lee, Jeong-Weon;Cho, Su-Won
    • Physical Therapy Korea
    • /
    • v.9 no.3
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study was to compare the experimental pain threshold when used in luminous lamp radiation and nonluminous lamp radiation with healthy person. Thirty normal subjects were randomly assigned two groups: a luminous lamp radiation group, and a nonluminous lamp radiation group. The infrared lamps were applied on L3 for thirty minutes. Each group was measured for experimental pain threshold and local temperature before, 15 and 30 minute radiation. For statistical differences in change of the experimental pain threshold and local temperature due to differences in lamp ray was compared using the independent t-test. And, General linear model for profile plots test was used. The results were as: 1. Local temperature was significantly increased in the nonluminous lamp group (p<.01). 2. Experimental pain thershold was significantly increased in the luminous lamp group (p<.05),(p<.01). This study indicate that luminous lamp radiation was more effects of increase experimental pain thershold than nonluminous lamp radiation. Further study is needed to compare the effects of after period radiation.

  • PDF

New Modeling Method for an Electrodeless Fluorescent Lamp Using the Relation of Lamp Output Power and the Modeling Coefficients of the Lamp (무전극램프의 출력전력 변화에 따른 새로운 모델링 기법)

  • Lim, Byoung-Noh;Jang, Mog-Soon;Sin, Dong-Seok;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1626-1631
    • /
    • 2007
  • This paper presents a new modeling method using lamp output power and the modeling coefficients of the lamp. The proposed method utilizes the lamp modeling coefficients such as equivalent impedance Z(p), coupling coefficient of the transformer k(p), turns ratio of the transformer n(p), and plasma resistance Rp(p) as a function of lamp output power. The equivalent impedance Z(p) was developed from the equivalent resistance Req(p) and equivalent inductance Leq(p) of the lamp. Simulation and experimental results of the proposed model are presented in order to validate the proposed method. The modeling method can use to design an impedance matching circuit for a Class-D inverter.

The Experimental Study on the Electric Potential Distribution by Electric Leakage in Street Lamp (가로등설비 누전시 전위분포에 대한 실험연구)

  • Park, Sang-Tae;Lee, Bok-Young;Hong, Sung-Ho;Choi, Chung-Suk;Gil, Hyung-Jun;Han, Woon-Ki
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.222-227
    • /
    • 2005
  • This paper presents study on the electric potential distribution when have a short in skeet lamp. In order to measure electric potential testing ground is built in. A experiment is conducted to simulate dry and submerged situation of street lamp. The street lamp is leaked by artificial means. And electric potential is measured in grounded street lamp and street lamp alone. The results show that touch voltage of grounded street lamp is possible to more high than street lamp alone. And the electric shock hazard is high because high electric potential is distributed near submerged street lamp. Also if street lamp is submerged ground is not useful to decrease electric shock hazard.

  • PDF

A STUDY ON LAMP BANK DESIGN OF SOLAR SIMULATOR (솔라시뮬레이터의 램프뱅크 설계에 관한 연구)

  • Baek, S.H.
    • Journal of computational fluids engineering
    • /
    • v.17 no.3
    • /
    • pp.45-52
    • /
    • 2012
  • This paper is a study on the design of the solar lamp bank which is a very important part of the solar simulator with the commercial metal halide lamps and infrared lamps. Lamp Bank is designed by the lamp bank design program based on point light source theory. The reliability of the program for lamp bank design is verified through irradiance variation experiments of a kind of lamp according to horizontal distance. Solar lamp bank facilitates heat distribution and satisfies the irradiance in the three wave length which test guidelines require. The shape of the ceiling board next to the lamp bank to promote the lamp cooling efficiency and to reduce temperature deviation and air velocity deviation in the chamber is so creative. The ceiling board of partial closed type is the best among several types.

Illuminating Characteristics of an Incandescent Lamp (전조용 백열등의 조도 특성)

  • 김태한;이경진;이정택
    • Journal of Biosystems Engineering
    • /
    • v.25 no.1
    • /
    • pp.25-32
    • /
    • 2000
  • Motivated by the need for developing the more efficient lighting system for light culture in the greenhouses, this paper aims to predict the illumination of incandescent lamp according to various levels of lighting and various kinds of the lamp. The results obtained in this experiment are summarized as follows. 1. The general equation to predict the illumination according to the kind of incandescent lamp and the installation height was suggested as {{{{y= { a + bx+ cx^2} over { 1+dx+ex^2~ + fx^3} [lx]}}}} , where , a, b, c , d, e and of were arbitrary constants. 2. Maximum illumination of hat-covered lamp of 60 W was 1.2 -1.5 times as many as uncovered lamp. 3. Maximum illumination of yellow color painted lamp of 100 W was 1.3 times as many as unpainted lamp.

  • PDF