Huh, Jin Won;Lee, Jung Yeon;Hong, Sang-Bum;Oh, Yeon Mok;Shim, Tae Sun;Lim, Chae-Man;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Koh, Younsuck
Tuberculosis and Respiratory Diseases
/
v.58
no.2
/
pp.160-166
/
2005
Background : Although home oxygen therapy in hypoxemic patients with chronic lung disease has been increasing over the decade in Korea, the present state has not been known well. This study was done to know the situation of home oxygen therapy in a Korean university hospital. Methods : Between January 1, 2000 and August 31, 2003, 86 patients prescribed home oxygen therapy by the pulmonary physicians of Asan Medical Center were investigated using their medical record and questionnaire. Results : Patients (52 men, mean age of 61 years) with home oxygen therapy were increasing by every year. Underlying diseases were COPD (n=29), tuberculous destroyed lung (n=18), bronchiectasis (n=15), ILD (n=12), and others. Baseline $FEV_1/FVC$, FVC, and $FEV_1$ of patients were $58.4{\pm}25.2%$, $54.5{\pm}17.1%$ of predicted, and $41.7{\pm}20.6%$ of pred. Mean oxygen flow was 1.5 L/min and mean duration per day was 14.5 hours. During therapy, mean $PaO_2$ values have increased from 51.2 to 77.7 mm Hg and $PaCO_2$ values have increased from 47.5 to 49.6 mm Hg. Only 16.5% of the subjects were monitored by visiting nurses or pulse oximeter. Three year survival rate was 56.6% and hypercapnic patients showed better prognosis. Conclusion : The patients with home oxygen therapy were increasing yearly and a part of them were monitored. The hypercapnea respiratory failure patients would have better prognosis.
Escherichia coli O157:H7 causes hemolytic uremic syndrome and hemorrhagic colitis in humans. The objectives of this study were to produce monoclonal antibody(MAb) against E. coli O157:H7 and to develop an enzyme linked immunosorbent assay(ELISA) for the rapid detection of E. coli O157:H7 in agri-stockbreeding. The characterization of MAb produced from hybridoma cell (HKEC 4G8-5) was validated by ELISA and Western blot. The produced MAb was specific to E. coli O157:H7 and showed weak cross-reaction to Staphylococcus aureus. The detection limit of ELISA based on 4G8-5 MAb was $10^5\;cell/mL$. Although the ELISA could not detect E. coli O157:H7 in the meat and sprout samples inoculated with $1{\times}10^1\;cell$/10 g without enrichment, the same samples after enrichment for 6 hr were confirmed to be positive by ELISA. These results indicated that the ELISA combined with short enrichment (6 hr) is useful tool for rapid screening of E. coli O157:H7 in various samples.
Kim Do-kyun;Lee Kyo Jgon;Joo Hyun Chul;Li Gyjong;Ahn Jiyoung;shim Yungee;Yoo Kyung Jong
Journal of Chest Surgery
/
v.38
no.8
s.253
/
pp.551-556
/
2005
Background: Complete arterial off-pump coronary artery bypass grafting (OPCAB) by sequential anastomoses with one or two arterial grafts provides favorable outcomes. However, problems of insufficient graft length, hypopefusion, kinking of graft, and unfavorable course of graft may be encountered. To solve these problems, we have used different technique with multiple arterial Y composite graft to allow end-to-side rather than sequential anastomoses and evaluated the results of this method. Material and Method: Between February 2003 and October 2004, If patients underwent total arterial OPCAB using multiple arterial V composite grafts with left internal mammary artery (LIMA), radial artery (RA), and right internal mammary artery (RIMA). We divided RA into multiple segments by number of distal target site after measuring of individual proper length and constructed arterial composite graft. One of segments was sutured end-to-side to LIMA and other segment was sutured end-to-side to the previously constructed radial graft. Postoperative graft patency was evaluated in 6f patients by multi-slice computed tomegraphy. Result: An average of $2.5\pm0.6$ arteries and $3.7pm0.7$ distal anastomoses per patient were done. There was no perioperative myocardial infarction, clinical hypoperfusion syndromes, and operative mortality. Postoperative mean CK-MB level was $17.4pm29.7\;IU/L.$Overall graft patency was $99.1\%\;(214/216)(LIMA:\;100\%,\;RA:\;98.4\%,\;RIMA:\;100\%).$ Conclusion: This technique allows total arterial OPCAB without technical problems and provides excellent early clinical results and graft patency. We believe that this technique is more convenient in the obtuse marginal area compared to sequential technique, and helpful in patients who require complex arterial grafting.
Lee, Ju Young;Shim, Jeong Ok;Yang, Hye Ran;Chang, Ju Young;Shin, Choong Ho;Ko, Jae Sung;Seo, Jeong Kee;Kim, Woo Sun;Kang, Gyeong Hoon;Song, Jeong Han;Kim, Jong Won
Clinical and Experimental Pediatrics
/
v.51
no.6
/
pp.650-654
/
2008
Glycogen storage disease (GSD) and mucopolysaccharidosis (MPS) are both independently inherited disorders. GSD is a member of a group of genetic disorders involving enzymes responsible for the synthesis and degradation of glycogen. GSD leads to abnormal tissue concentrations of glycogen, primarily in the liver, muscle, or both. MPS is a member of a group of inherited lysosomal storage diseases, which result from a deficiency in specific enzymatic activities and the accumulation of partially degraded acid mucopolysaccharides. A case of a 16-month-old boy who presented with hepatomegaly is reported. The liver was four finger-breadth-palpable. A laboratory study showed slightly increased serum AST and ALT levels. The liver biopsy showed microscopic features compatible with GSD. The liver glycogen content was 9.3% which was increased in comparison with the reference limit, but the glucose-6-phosphatase activity was within the normal limit. These findings suggested GSD other than type I. Bony abnormalities on skeletal radiographs, including an anterior beak and hook-shaped vertebrae, were seen. The mucopolysaccharide concentration in the urine was increased and the plasma iduronate sulfatase activity was low, which fulfilled the diagnosis criteria for Hunter syndrome (MPS type II). To the best of the authors' knowledge, this is the first case of GSD and Hunter syndrome being identified at the same time.
Growth of Campanula punctata 'Rubriflora' plantlets, as affected by three levels of photosynthetic photon flux (PPF), 70, 110, and $220{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, two levels of $CO_2$ concentration, 500 and $1,500{\mu}mol{\cdot}m^{-1}$, and two levels of number of air exchanges per hour (NAEH), 0.1 and $2.8 h^{-l}$, was studied. Explants were obtained from photomixotrophically-micropropagated plantlets. Four explants were planted in each $3.7{\times}10^{-4}m^3$ polycarbonate box containing MS basal medium and no added sucrose. Explants were cultured under cool-white fluorescent lamps for $16h{\cdot}d^{-1},\;at\;25\pm1^{\circ}C$ temperature, and $70\~80\%$ relative humidity In treatments of $2.8h^{-1}$ NAEH, a 10mm round hole made on the vessel cap was sealed with a microporous filter. For higher $CO_2$ concentrations in the culture room, $CO_2$ gas was provided from a tank of liquefied $CO_2$. Fresh and dry weights, length of the longest root, and number of leaves significantly increased with increasing PPF and especially $CO_2$ concentration. Length of the longest root, number of leaves, fresh and dry weights, and chlorophyll concentration were enhanced with increased NAEH. However, leaf area was the smallest in the $220{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}\;PPF\;2.8h^{-1}$ NAEH and especially, $1,500{\mu}mol{\cdot}mol^{-1}\;CO_2$ concentration treatment. Treatment effect became more produced with time. Overall, treatment with $220{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}\;PPF\;and\;1,500{\mu}mol{\cdot}mol^{-1}\;CO_2$ gave the most vigorous growth.
This study was conducted to evaluate the bactericidal activity of weakly alkalic electrolyzed water (WEW) against Salmonella Typhimurium and Staphylococcus aureus on perilla leaves. The influences of organic matter, inform of bovine serum, and the ratio of WEW to perilla leaves on bactericidal activity of WEW were also examined. Treatment of these organisms with 25, 50, 75, and 100 ppm WEW was performed for 1 min, 3 min and 5 min, respectively. Higher bactericidal activity was observed after a treatment with 100 ppm WEW compared to a treatment with 25 ppm WEW by 0.7 $log_{10}CFU/g$. The bactericidal activity of WEW also decreased with increasing bovine serum concentration. At the ratio of 10:1 (WEW: perilla leave), levels of Salmonella Typhimurium and Staphylococcus aureus were only reduced by 0.57 and 0.79 $log_{10}CFU/g$, respectively. It is suggested that the removal of organic debris prior to application of sanitizers and treatment above the ratio of 25:1 (WEW: perilla leave) is needed in order to improve WEW activity.
In this study, an electronics industrial wastewater activated sludge model (e-ASM) to be used as a Water Digital Twin was calibrated based on real high-tech electronics industrial wastewater treatment measurements from lab-scale and pilot-scale reactors, and examined for its treatment performance, effluent quality prediction, and optimal process selection. For specialized modeling of a high-tech electronics industrial wastewater treatment system, the kinetic parameters of the e-ASM were identified by a sensitivity analysis and calibrated by the multiple response surface method (MRS). The calibrated e-ASM showed a high compatibility of more than 90% with the experimental data from the lab-scale and pilot-scale processes. Four electronics industrial wastewater treatment processes-MLE, A2/O, 4-stage MLE-MBR, and Bardenpo-MBR-were implemented with the proposed Water Digital Twin to compare their removal efficiencies according to various electronics industrial wastewater characteristics. Bardenpo-MBR stably removed more than 90% of the chemical oxygen demand (COD) and showed the highest nitrogen removal efficiency. Furthermore, a high concentration of 1,800 mg L-1 T MAH influent could be 98% removed when the HRT of the Bardenpho-MBR process was more than 3 days. Hence, it is expected that the e-ASM in this study can be used as a Water Digital Twin platform with high compatibility in a variety of situations, including plant optimization, Water AI, and the selection of best available technology (BAT) for a sustainable high-tech electronics industry.
Nitrogen balance in the regional scale which was calculated the difference between nitrogen input and output was estimated to assess the impact of rice cultivation on water environment. Nitrogen balances in Gyeonggi province, where nitrogen concentration in irrigation water was high and in Chungnam province, where nitrogen absorbtion by rice was high, were -5.4 and -8.3 kg $-8.3kg\;ha^{-1}\;yr^{-1}$, respectively. Nitrogen balances of paddy field in Gangwon province, where nitrogen output was small and irrigation water was clean, and in Gyeongnam province, where organic matter content of soil was high and rice yield was low, were 4.9 and $14.0kg\;ha^{-1}\;yr^{-1}$, respectively. Average nitrogen balance and total nitrogen absorption of paddy field in Korea were estimated to $-0.3kg\;ha^{-1}\;yr^{-1}$ and $-3,315Mg\;yr^{-1}$, respectively. When the nitrogen concentration in irrigation water was increased by $1mg \;L^{-1}$, nitrogen balance of rice paddy changed by $-2.91kg\;ha^{-1}\;yr^{-1}$. Also, when nitrogen fertilizer applied was decreased from 110 to $90kg\;ha^{-1}$ and the same harvest was maintained, the nitrogen absorption by rice paddy from irrigation water was estimated to increase by 10,600 Mg per year in Korea. However, in cases, the harvest was reduced to either 90% or 85%, nitrogen balances were changed from -11.7 to -2.3 and $2.4kg\;ha^{-1}$, respectively. These results suggest that the reduction of nitrogen fertilizer use may not always lead to a negative nitrogen balance and sustainable agriculture can achieve by not cutting down the use of fertilizer only but by reduction of fertilizer application concurrently by maintenance of harvest and by utilization of environmental characteristics such as nutrient contents in irrigation water and soils.
This study was carried out to investigate the deposition aspect of acid precipitation in rural area of Chonbuk province by analysis of the chemical components in the precipitation at National Honam Agricultural Experiment Station, RDA in the suburbs of Iri from Jan. to Dec. in 1992. The results are summarized as follows: 1. The frequency of acid precipitation was 82.5% in 1992 and the month of the lowest frequency of 17% was June. 2. The pH range of the most precipitation amount was pH $4.5{\sim}5.0$ of 54.0% and the amount and ratio of the precipitation below pH 4.0 were 9.6 mm and 1.1%, respectively. 3. The seasonal acidity of precipitation was Summer(4.78)>Fall(4.59)>Spring(4.52)>Winter(4.16). 4. The components showed significant correlation with pH value were $SO_4^{2-}$ and $NO_3$ and the equivalence ratio between two components was 2.85 : 1. 5. The order of the major ion concentration in the precipitation was $SO_4^{2-}$>$NH_4^+$>$Cl^-$>$Ca^{2+}$>$NO_3^-$>$Na^+$>$H^+$>$K^+$>$Mg^{2+}$ and the equivalence ratio of total anion to cation was 1.20. 6. Deposition amount of nitrogen ($NO_3-N$ + $NH_4-N$) and potassium ($K_2O$) were 1.19 and 0.53 kg/l0a/year, respectively.
Park, Sang-Gon;Choi, Young-Dong;Lee, Chae-Won;Jeong, Myeong-Jin;Kim, Jeong-Sook;Chung, Duck-Hwa;Shim, Won-Bo
Journal of Food Hygiene and Safety
/
v.30
no.1
/
pp.28-34
/
2015
This study is to investigate microbiological hazards which can be used as fundamental data to adequately control leeks hazards and develop leeks GAP model for those who want to get GAP system. The microbiological investigations on cultivation environments (soil and water), crops (leeks), personal hygiene (workers' hands, clothes and gloves) and working tools (boxes) have been conducted for one year, so the period was classified under non-cultivation, cultivation, and post harvest. Total bacteria was detected from soil (4.0~6.7 log CFU/g), leeks (4.6~5.1 log CFU/g), hands (ND~3.3 log CFU/hand) and gloves ($ND{\sim}5.4\;log\;CFU/cm^2$) while nothing was detected from the other samples. The coliform contamination of leeks (4.8~5.0 log CFU/g) was more high than that of soil (3.9~4.2 log CFU/g). In case of foodborne pathogens, only B. cereus was detected at the level of 0.5~4.6 log CFU/g (or hand, $100cm^2$). Fungi was observed at the level of 2.1~3.8 log CFU/g (or hand, $100cm^2$) excepting water and some working tools. These results demonstrate that the contamination of leeks is comparatively higher than that of soil sample. The reason may be the cross-contamination by biological hazards presenting on soil. Therefore, it is necessary to properly control soil and fertilizer for safety against biological hazards.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.