• Title/Summary/Keyword: L1 transfer

Search Result 1,094, Processing Time 0.036 seconds

Effects of Prandtl Numbers on Heat Transfer of Backward-Facing Step Laminar Flow with a Pulsating Inlet (입구유동 가진이 있는 층류 후향계단 유동에서 열전달에 대한 프란틀수 효과해석)

  • Kim, Won-Hyun;Park, Tae-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.9
    • /
    • pp.923-930
    • /
    • 2012
  • The wall heat transfer of backward-facing step laminar flows with different Prandtl numbers and a pulsating inlet is investigated by unsteady simulations. The inlet is perturbed by the variation of frequency and amplitude. Temperature-dependent transport properties are adopted. Various characteristics of the wall heat transfer are explained by the variation of the thermal boundary layer. For Pr < 1, the wall heat transfer of temperature-dependent properties is decreased compared to that of constant properties, whereas it increases for Pr < 1. In addition, the wall heat transfer increases depending on the pulsating amplitude. However, the results of frequency variation for St < 0.2 show that the heat transfer is strongly enhanced at a specific frequency. In particular, the increase in the wall heat transfer is strongly related to the root mean square of the fluctuations of the reattachment length.

Effects of Hydrocarbon Additions on Gas-liquid Mass Transfer Coefficients in Biphasic Bioreactors

  • Silva, Teresa Lopes da;Calado, Vitor;Silva, Nadia;Mendes, Rui L.;Alves, Sebastiao S.;Vasconcelos, Jorge M.T.;Reis, Alberto
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.3
    • /
    • pp.245-250
    • /
    • 2006
  • The effects of aliphatic hydrocarbons (n-hexadecane and n-dodecane) on the volumetric oxygen mass transfer coefficient $(k_L\;a)$ were studied in flat alveolar airlift reactor and continuous stirred tank reactors (CSTRs). In the flat alveolar airlift reactor, high aeration rates (>2vvm) were required in order to obtain efficient organic-aqueous phase dispersion and reliable $k_La$ measurements. Addition of 1% (v/v) n-hexadecane or n-dodecane increased the $k_La$ 1.55- and 1.33-fold, respectively, compared to the control (superficial velocity: $25.8{\times}10^{-3}m/s$, sparger orifice diameter: 0.5 mm). Analysis of the gas-liquid interfacial area a and the liquid film mass transfer coefficient $k_L$ suggests that the observed $k_La$ increase was a function of the media's liquid film mass transfer. Addition of 1% (v/v) n-hexadecane or n-dodecane to analogous setups using CSTRs led to a $k_La$ increase by a factor of 1.68 and 1.36, respectively (superficial velocity: $2.1{\times}10^{-3}m/s$, stirring rate: 250 rpm). These results propose that low-concentration addition of oxygen-vectors to aerobic microbial cultures has additional benefit relative to incubation in purely aqueous media.

COMPUTATIONAL ANALYSIS OF AN ELECTRO-THERMAL ICE PROTECTION SYSTEM IN ATMOSPHERIC ICING CONDITIONS (대기 결빙 조건에서의 전기열 방식 결빙보호 시스템에 관한 전산해석)

  • Raj, L.P.;Myong, R.S.
    • Journal of computational fluids engineering
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • Atmospheric icing may have significant effects not only on safety of aircraft in air, but also on performance of wind turbine and power networks on ground. Thus, ice protection measure should be developed to protect these systems from icing hazards. A very efficient method is the electro-thermal de-icing based on a process by which ice accretion is melted and blown away through aerodynamic forces. In this computational study, a state-of-the-art icing code, FENSAP-ICE, was used for the analysis of electro thermal de-icing system. Computational results including detailed conjugate heat transfer analysis were then validated with experimental data. Further, the computational model was applied to the DU21 airfoil section of NREL 5MW wind turbine with calculated heater parameters.

Korean Learners' Development of English Passive Constructions

  • Park, Hye-Sook
    • English Language & Literature Teaching
    • /
    • v.15 no.4
    • /
    • pp.199-216
    • /
    • 2009
  • This study investigates how Korean speakers develop their interlanguage of English passive constructions with a reference to the learners' grammar proficiency levels. Sixty two college students of different levels of English participated in this study. They were asked to complete a sentence-completion task. Their production was classified into accurate passives, malformed passives, pseudo-passives, unaccusatives, and actives according to the use of transitive, ergative and unergative verbs. They then were further analyzed depending on the subjects' levels of grammar by three main factors: L1 transfer, the English voice system, and universal cognitive factors. The results showed that the subjects of the lower group produced more pseudo-passives, malformed passives, and overpassivization than those of the higher group, and even subjects of higher group still made passives for ergative verbs. It was also shown that L1 and universal factors had more influence on the lower group than on the higher group. Based on the analyses of the subjects' responses, the development of the English passive system by Korean learners is shown and some implications are suggested for effective teaching of English.

  • PDF

Convective Heat Transfer in a Channel with Isothermal Rectangular Beams (등온사각빔이 부착된 채널에서의 대류열전달)

  • Ree, J.S.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.63-72
    • /
    • 1995
  • Convective heat transfer in a two-dimensional horizontal and vertical channel with isothermal rectangular beams attached to one adiabatic wall is investigated from the numerical solution of Navier-Stokes and energy equations. The solutions have been obtained for dimensionless beam spacings, S/L=1~4, aspect ratios of beam, H/B=0.25~4, Reynolds numbers, Re=50~1000 and Grashof numbers, $Gr=0{\sim}5{\times}10^4$. The total mean Nusselt number, Nu_T for horizontal and vertical channels shows same value at Gr=0. As Gr increases, Nu_T for horizontal channel increases, but Nu_T for vertical channel shows similar value at S/L=2, H/B=0.25, Re=100. The total mean Nusselt number for horizontal channel is higher than that for vertical channel. As H/B increases, $Nu_T$ for both channel decrease at $Gr=10^4$, Re=100.

  • PDF

Natural Convection in a Rectangular Enclosure with Heat Sources at the Bottom (밑면에 열원이 존재하는 밀폐공간에서의 자연대류)

  • Kwon, Y.I.;Kim, S.J.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.3
    • /
    • pp.197-205
    • /
    • 1991
  • A numerical study has been performed to investigate two dimensional natural convection heat transfer in a rectangular enclosure with heat sources of constant temperature at the bottom. Calculations were made for various dimensionless heat source lengths, W/L=0.1-0.5, and positions of heat sources at $Gr=2.57{\times}10^6$, Pr=0.71 and Ks/Kf=28.98. For various positions of heat sources, the maximum local Nusselt numbers generally show X=0.81-0.85 at the bottom and X=0.23 at the top. For various dimensionless heat source lengths, the maximum local Nusselt numbers at the bottom show W/L=0.4 for one heat source, W/L=0.2 for two heat sources with fixed centers, W/L=0.5 for two heat sources with moved centers. Finally the maximum heat transfer at the bottom exhibits in condition of W/L=0.4 for two heat sources with moved centers.

  • PDF

A simplified design approach for modelling shear force demand on tower walls supported on a transfer structure in regions of lower seismicity

  • Yacoubian, Mehair;Lam, Nelson;Lumantarna, Elisa;Wilson, John L.
    • Earthquakes and Structures
    • /
    • v.15 no.1
    • /
    • pp.97-111
    • /
    • 2018
  • Buildings featuring a transfer structure can be commonly found in metropolitan cities situated in regions of lower seismicity. A transfer structure can be in the form of a rigid plate or an array of deep girders positioned at the podium level of the building to support the tower structure of the building. The anomalous increase in the shear force demand on the tower walls above the podium is a major cause for concern. Design guidance on how to quantify these adverse effects is not available. In this paper a simplified method for quantifying the increase in the shear force demand on the tower walls is presented. In view of the very limited ductile nature of this type of construction the analysis presented herein is based on linear elastic behaviour.

Studies on Embryo Transfer in Cattle (소의 수정란이식에 관한 연구)

  • 김일화;손동수;전대규;조현주;류일선;윤상보;최창렬;이광원;김준식
    • Journal of Embryo Transfer
    • /
    • v.5 no.2
    • /
    • pp.38-44
    • /
    • 1990
  • This study was carried out to produce superior dairy cattle by embryo transfer. Seven dairy cows were superovulated with divided injection of FSH 4Omg for 5 days started on day 9 to 14 of the estrus cycle and injection of PGF$_2$$\alpha$ 45mg on day 4 of FSH injection. Donor cows were flushed to collect embryos on day 7 or 8 of the estrus cycle. Fresh embryos collected were transferred to synchronized dairy recipients or frozen using glycerol 3 step method to he equilibrated. And 35 embryos which were frozen using glycerol 6 step method were imported from U.S.A. After glycerol dilution of frozen embryos was done by reverse density during freezing. frozen-thawed embryos were transferred to synchronized dairy or beef recipients. The results obtained were as follows; 1. Total of 24 embryos were collected from 7 donor cows flushed and transferable embryos were 18 (75.0%). 2. Among 24 embryos. morula, early blastocyst, blastocyst, expanded blastocyst and unfertilized ova were 3 (12.5%), 1 (4.2%), 10 (41.6%), 4 (16.7%) and 6 (25.0%), respectively. 3. Heat inducing rate after 1st and 2nd injections of PGF$_2$$\alpha$ in Holstein and beef cattle was 83.3% and 71.4% and 62.5% and 69.2%, respectively. 4. Among 56 recipients, 23 head were pregnant (41.1%). The pregnancy rate of fresh embryos was 50.0% (1/2 heads) and the pregnancy rate of frozen embryos which were frozen using glycerol 3 step and using glycerol 6 step imported from U.S.A. was 52.6%(l0/19 heads) and 34.3%(12/35 heads), respectively. 5. The pregnancy rate of blastocyst (60.0%) was higher than that of morula (39.0%), early blastocyst (25.0%) and expanded blastocyst (0%). 6. The pregnancy rate of grade I embryos (52.2%) was higher than that of grade 2 (34.6%) and grade 3 (28.6%). 7. The pregnancy rate according to synchrony of recipient with donor was higher in simultaneous recipient (55.0%) and +l2hrs' (53.8%) than -24hrs' (23.5%), -l2hrs' (20.0%) and +24hrs' (0%).

  • PDF

Studies on the Charge-transfer Complex including Aflatoxin $B_1$ -Part I. Charge-transfer Complex with Benzene- (Aflatoxin $B_1$ Charge-transfer Complex에 관(關)한 연구(硏究) -제1보(第一報) Benzene과의 Charge-transfer Complex-)

  • Noh, Ick-Sam;Lee, Kang-Heup
    • Applied Biological Chemistry
    • /
    • v.17 no.2
    • /
    • pp.143-148
    • /
    • 1974
  • The interaction of the carcinogenic mycotoxin, Aflatoxin $B_1$, with the electron-donating molecule, benzene, was studied spectrophotometrically. The formation of charge-transfer complex between Aflatoxin $B_1$ and benzene in the presence of zinc chloride was observed and the apparent equilibrium constant of this charge-transfer complex was found to be 0.198 (liter $mole^{-1}$). It is assumed that, as the result of this study, some charge-transfer complexes could be formed between the weak electron-accepting Aflatoxin $B_1$ and strong electron-donating molecules, and the spectral changes occurred in the binding of Aflatoxin $B_1$ with proteins or DNA is attributed to the existence of charge-transfer type interaction.

  • PDF