• Title/Summary/Keyword: L-series

검색결과 1,439건 처리시간 0.031초

11-kV Series-Connected H-Bridge Multilevel Converter for Direct Grid Connection of Renewable Energy Systems

  • Islam, Md. Rabiul;Guo, Youguang;Zhu, Jian Guo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.70-78
    • /
    • 2012
  • Due to the variable nature of renewable energy resources and power demand by consumers, it is difficult to operate a power system installed with only one type of renewable energy resource. Grid-based renewable generation may be the only solution to overcome this problem. The conventional approach based on a low-voltage converter with power frequency transformer is commonly employed for grid connection of offshore renewable energy systems. Because of the heavy weight and large size of the transformer, the system can be expensive and complex in terms of installation and maintenance. In this paper, an 11-kV series connected H-bridge (SCHB) multilevel voltage source converter (VSC) is proposed to achieve a compact and light direct grid connection of renewable energy systems. This paper presents the design, simulation and analysis of a five level (5L)-SCHB and an eleven level (11L)-SCHB VSC for 11-kV grid-based renewable energy systems. The performance, cost, modulation scheme and harmonic spectra of the converter are analyzed.

타동용 4 분제 2상쵸퍼방식의 특성 (A Study of Two Phase Chopper System with Four Separate Groups of DC Motors in Powering)

  • 정연택;한경희;김용주;이영일;오봉환
    • 대한전기학회논문지
    • /
    • 제36권3호
    • /
    • pp.171-178
    • /
    • 1987
  • A study of two phase chopper system with four separate groups of DC motors in powering. A novel two phase chopper system with four separate groups of DC motors which applies the principles of two phase chopper with two separate groups of DC motors is dealt with this article. The main circuit consists of eight sets of chopping parts, four diodes and four separate groups of DC motors. Four groups of DC motors are driven through the series and parallel connections to each other in accordance with the operating conditions of the choppers. Although the proposed chopper circuit requires more circuit elements than the conventional two phase chopper system with combined output or two phase chopper system with two separate groups of DC motors, it has the following advantages` (1). It is possible to drive twice as much motors as conventional system does, using esisting receiving-and equipments and motors. (2). It is possible to control load voltage continuously from 0 to source voltage by changing time-ratio from 0 to 1. (3). Load current division becomes equalized. Therefore it is possible to drive not only series motors but also shunt and separately exited motors. (4). When smoothing reactor L is small, harmonic components of the proposed circuit is not so large. Therefore, the value of L can be determined from viewpoints of allowable value of ripple-ratio and current unbalance factor.

농업용수 활용을 위한 비피압지하수관정 수온의 시계열 변동특성 (Time Series Change Characteristics of Unconfined Groundwater Wells Temperatures for Agricultural Water Use)

  • 박승기;정남수
    • 농촌계획
    • /
    • 제22권1호
    • /
    • pp.13-23
    • /
    • 2016
  • There is a need to analyze unconfined groundwater behavior since the demand of groundwater use has been increasing. While unconfined groundwater temperature is tend to be affected by air temperature, it is hard to find an empirical study in South Korea. In this research, we try to determine the relationship between daily average air temperature and daily average groundwater temperature by time-sequential analysis of groundwater monitoring wells in Galshin basin in Yesan-Gun, Chungcheongnam-Do. In addition, models to estimate groundwater temperature from air temperature were developed. In this research 101-day moving average method with measured air temperature is used to estimate groundwater temperature. To verify the developed model, estimated values of average groundwater temperature with 101 moving average are compared to the measured data from September 10 2007 to September 9 2008. And, Nash-Stucliff Efficiency and Coefficient of Determination were 0.970 and 0.976, therefore it was concluded that the model allowing groundwater temperature estimation from air temperature is with reasonable applicability.

낙동강 유역의 유역 유출량 산정에 따른 지역별 가뭄 빈도분석 (Regional Drought Frequency Analysis with Estimated Monthly Runoff Series in the Nakdong River Basin)

  • 김성원
    • 한국농공학회지
    • /
    • 제41권5호
    • /
    • pp.53-67
    • /
    • 1999
  • In this study, regional frequency analysis is used to determine each subbasin drought frequency with watershed runoff which is calculated with Tank Model in Nakdong river basin. L-Monments methd which is almost unbiased and nearly normal distribution is applied to estimate paramers of drought frequency analysis of monthly runoff time series. The duration of '76-77 was the most severe drought year than othe rwater years in this study. To decide drought frequency of each subbasin from the main basin, it is calculated by interpolaing runoff from the frequency-druoght runoff relationship. and the linear regression analysis is accomplished between drought frequency of main basin and that of each subbasin. With the results of linear regression analysis, the drought runoff of each subbasin is calculated corresponing to drought frequency 10,20 and 30 years of Nakdong river basin considering safety standards for the design of impounding facilities. As the results of this study, the proposed methodology and procedure of this study can be applied to water budget analysis considering safety standards for the design of impounding facilities in the large-scale river basin. For this purpose, above all, it is recommanded that expansion of reliable observed runoff data is necessary instead of calculated runoff by rainfall-runoff conceptual model.

  • PDF

12V, 1000A 절연형 양방향 공진형 DC-DC 컨버터 개발 (Development of 12V, 1000A Isolated Bidirectional Resonant DC-DC Converter)

  • 박준성;최세완
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.57-63
    • /
    • 2014
  • In this paper a bidirectional DC-DC converter is proposed for renewable energy systems, eco-friendly vehicles, energy storage systems, uninterruptible power supply(UPS) systems and battery test equipments. The two-stage bidirectional converter employing a fixed-frequency series loaded resonant converter is designed to be capable of operating under zero-current-switching turn on and turn off regardless of voltage and load variation, and hence its magnetic components and EMI filters can be optimized. And efficiencies and volumes of the two-stage bidirectional converters are compared according to configuration of isolated and non-isolated parts and a two-stage topology suitable for low voltage and high current applications is proposed. A 12kW(12V, 1000A) prototype of the proposed converter has been built and tested to verify the validity of the proposed operation.

Complex Vector Modeling and Series Decoupling Current Control Strategy of High-Power L/LCL Type Grid-Connected Converter Under Low Switching Frequency

  • Wang, Yingjie;Jiao, Lanyi;Yang, Bo;Wang, Wenchao;Liu, Haiyuan
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1879-1888
    • /
    • 2018
  • With power level of grid-connected converters rising, the switching frequency of the switching devices is commonly greatly reduced to improve its power capacity. However, this results in serious couplings of the dq current components, which leads to degradation of the static and dynamic performances of grid-connected converters and fluctuations of the reactive power in dynamic processes. In this paper, complex vector models under low switching frequency are established for an L/LCL grid-connected converter, and the relationship between the switching frequency and the coupling degree is analyzed. In addition, a series decoupling current control strategy is put forward. It is shown that the proposed control strategy can eliminate the couplings, improve the performances and have good robustness to parameter variations through static and dynamic characteristics analyses and a sensitivity analysis. Experimental and simulation results also verify the correctness of the theoretical analyses and the superiority of the proposed control strategy.

Existence theorems of an operator-valued feynman integral as an $L(L_1,C_0)$ theory

  • Ahn, Jae-Moon;Chang, Kun-Soo;Kim, Jeong-Gyoo;Ko, Jung-Won;Ryu, Kun-Sik
    • 대한수학회보
    • /
    • 제34권2호
    • /
    • pp.317-334
    • /
    • 1997
  • The existence of an operator-valued function space integral as an operator on $L_p(R) (1 \leq p \leq 2)$ was established for certain functionals which involved the Labesgue measure [1,2,6,7]. Johnson and Lapidus showed the existence of the integral as an operator on $L_2(R)$ for certain functionals which involved any Borel measures [5]. J. S. Chang and Johnson proved the existence of the integral as an operator from L_1(R)$ to $C_0(R)$ for certain functionals involving some Borel measures [3]. K. S. Chang and K. S. Ryu showed the existence of the integral as an operator from $L_p(R) to L_p'(R)$ for certain functionals involving some Borel measures [4].

  • PDF

Induction of somatic embryogenesis from immature zygotic embryos and young apical leaves in cork oak (Quercus suber L.)

  • El Ansari, Zineb Nejjar;El Bouzdoudi, Brahim;Errabii, Tomader;Saidi, Rabah;El Kbiach, Mohammed L'bachir
    • Journal of Plant Biotechnology
    • /
    • 제48권1호
    • /
    • pp.44-53
    • /
    • 2021
  • The present work aims to study the induction of somatic embryogenesis in cork oak (Quercus suber L.) from immature zygotic embryos and young apical leaves obtained from 2-month-old seedlings through acorn germination on sterilized peat. The immature zygotic embryos were grown for 1 month on the mineral solution of MS in the presence of 4.52 µM 2,4-D and 30 g/L sucrose. They were then transferred to the same mineral solution with no added growth regulators. In the third subculture, yellow somatic embryos, characterized by two voluminous cotyledons, were differentiated from the radicle of the immature zygotic embryos. The induction of somatic embryogenesis in young leaves required a series of transfers on different culture media containing 30 g/L sucrose and 100 mg/L myo-inositol. Secondary or recurrent somatic embryogenesis occurred within the immature somatic embryo radicles after 1 month of culture on growth regulator-free medium containing WPM macronutrients, MS micronutrients, and vitamins.

InSAR Signature 시계열 분석을 통한 토지피복분류 (The Application of InSAR Signature Time Series for Landcover Classification)

  • 윤혜원;최윤수;윤하수;고종식;조성길
    • Spatial Information Research
    • /
    • 제22권1호
    • /
    • pp.27-33
    • /
    • 2014
  • SAR 영상은 관측시간과 기상현상 등의 외부 환경 영향을 받지 않고 수시로 데이터 취득이 가능하며 광학영상보다 광범위한 관측 영역을 포함하기 때문에 레이더간섭기법 (InSAR)을 이용한 토지피복분류 기법은 큰 이점을 갖는다. 본 연구에서는 L밴드 ALOS PALSAR의 후방산란계수와 긴밀도를 이용한 새로운 토지피복분류 기법을 개발하고 최근 화산 폭발 가능성으로 인해 주목받고 있는 백두산 지역에 시험 적용하였다. 새로운 토지피복분류 체계는 ALOS PALSAR의 HH, HV편광 모드의 영상을 InSAR 시계열 상에서 패킷의 형태로 재구성하고 주성분 분석을 도입하여 분류의 신뢰도 향상을 시도하였다. 또한 MODIS 등 광학 영상 기반 분류와 상호 검증하여 정확도를 확인하였다.

도파기와 기생 패치를 이용한 직렬-급전 다이폴 쌍 안테나의 이득 향상 (Gain Enhancement of Series-fed Dipole Pair Antenna Using Director and Parasitic Patches)

  • 여준호;이종익
    • 한국정보통신학회논문지
    • /
    • 제21권10호
    • /
    • pp.1855-1861
    • /
    • 2017
  • 본 논문에서는 한 개의 도파기, 두 개의 기생 패치를 이용하여 이중 직렬-급전 다이폴 쌍 안테나(series-fed dipole pair antenna; SDPA)의 이득을 향상시키는 방법에 관하여 연구하였다. 변형된 밸런을 이용하여 대역폭을 늘리고, 한 개의 도파기와 두 개의 기생 패치를 추가하여 중간 및 고주파수 대역에서 이득을 높였다. 도파기와 기생 패치 사이의 거리에 따른 안테나의 특성 변화를 분석하여 1.55-2.98 GHz 대역에서 7 dBi 이상의 이득을 갖는 SDPA를 설계하였다. 성능 검증을 위해 제안된 SDPA를 $90mm(L){\times}135mm(W)$의 크기로 FR4 기판 위에 제작하였다. 제작된 안테나는 전압 정재파비(voltage standing wave ratio; VSWR)가 2 이하인 대역이 1.56-3.10 GHz으로 나왔다. 또한 1.54-3.00 GHz 대역에서 이득이 7 dBi 이상을 유지하는 것을 확인하였다.