• Title/Summary/Keyword: L(0,2) Mode

Search Result 521, Processing Time 0.028 seconds

Factors influencing arterial $CO_2$ tension in cats during high frequency oscillation ventilation (고빈도 진동 환기가 동맥혈의 호흡성 가스에 미치는 영향)

  • Do, Jun-Young;Lee, Jae-Yick;Lee, Kwan-Ho;Kim, Yeung-Jo;Chung, Jae-Chun;Lee, Hyun-Woo;Lee, Suck-Kang
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.47-55
    • /
    • 1989
  • High frequency ventilation (HFV) is a new ventilatory technique that uses very small tidal volume(less than the anatomic dead space) and high frequency, and classified 4 distinct types according to frequency and mode of gas delivery. The mechanism of gas transport of high frequency oscillation ventilation(HFOV) is somewhat different to other types of HFV. To evaluate the determinants of $PaCO_2$ in HFOV, a study was done with a HFOV on 9 cats, and the results are : 1) $PaCO_2$ was not correlated with frequency at the constant stroke volume(6 voltage) and bias flow (6L/minutes). 2) $PaCO_2$ was correlated with stroke volume but not with bias flow under the constant frequency(15Hz/min) and bias flow(3 to 6L/min). From above results, the main determinant of $PaCO_2$ on artificial ventilation with HFOV was stroke volume, but further study between flow, the site of delivery to the airway and humidification of bias flow and $CO_2$ elimination is required in future research.

  • PDF

The Effects of Inspiratory Pause on Airway Pressure and Gas Exchange under Same I:E ratio in Volume-controlled Ventilation (Volume-Controlled Mode의 기계환기시 동일환 I:E Ratio하에서 Inspiratory Pause가 기도압 몇 가스교환에 미치는 영향)

  • Choi, Won-Jun;Jung, Sung-Han;Lee, Jeong-A;Choe, Kang-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1022-1030
    • /
    • 1998
  • Background : In volume-controlled ventilation, the use of inspiratory pause increases the inspiratory time and thus increases mean airway pressure and improves ventilation. But under the same I : E ratio, the effects of inspiratory pause on mean airway pressure and gas exchange are not certain. Moreover, the effects may be different according to the resistance of respiratory system. So we studied the effects of inspiratory pause on airway pressure and gas exchange under the same I : E ratio in volume-controlled ventilation. Methods: Airway pressure and arterial blood gases were evaluated in 12 patients under volume-controlled mechanical ventilation with and without inspiratory pause time 5%. The I : E ratio of 1 : 3, $FiO_2$, tidal volume, respiratory rate, and PEEP were kept constant. Results: $PaCO_2$ with inspiratory pause was lower than without inspiratory pause ($38.6{\pm}7.4$ mmHg vs. $41.0{\pm}7.7$ mmHg. p<0.01). P(A-a)$O_2$ was not different between ventilation with and without inspiratory pause $185.3{\pm}86.5$ mmHg vs. $184.9{\pm}84.9$ mmHg, p=0.766). Mean airway pressure with inspiratory pause was higher than without inspiratory pause ($9.7{\pm}4.0\;cmH_2O$ vs. $8.8{\pm}4.0\;cmH_2O$, p<0.01). The resistance of respiratory system inversely correlated with the pressure difference between plateau pressure with pause and peak inspiratory pressure without pause (r=-0.777, p<0.l), but positively correlated with the pressure difference between peak inspiratory pressure with pause and peak inspiratory pressure without pause (r=0.811, p<0.01). Thus the amount of increase in mean airway pressure with pause positively correlated with the resistance of respiratory system (r=0.681, p<0.05). However, the change of mean airway pressure did not correlated with the change of $PaCO_2$. Conclusion: In volume-controlled ventilation under the same I : E ratio of 1 : 3, inspiratory pause time of 5% increases mean airway pressure and improves ventilation. Although the higher resistance of respiratory system, the more increased mean airway pressure, the increase in mean airway pressure did not correlated with the change in $PaCO_2$.

  • PDF

Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image (PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가)

  • Park, Sun-Myung;Lee, Hyuk;Hong, Gun-Chul;Chung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.41-46
    • /
    • 2011
  • Purpose: The result of exam using an imaging device is very closely related with the image quality. Moreover, this image quality can be changed according to the condition of image acquisition and evaluation method. In this study, we evaluated the image quality according to the difference of pre-set method in PET/CT image. Materials & Methods: PET/CT Discovery STe16 (GE Healthcare, Milwaukee, USA), Chest PET phantom (Experiment 1) and 94 NEMA phantom (Experiment 2) were used. Phantom were filled with $^{18}F$-FDG maintaining hot sphere and background ratio to 4:1. In the case of experiment 1, we set the radio activity concentration on 3.5, 6.0, 8.6 kBq/mL. In the case of experiment 2, we set the radio activity concentration on 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL. All experiments were performed with the time-set method for 2 minutes 30 seconds per frame and the count-set method with one hundred million counts in 3D mode after CT transmission scan. For the evaluation of the image quality, we compared each results by using the NECR and SNR. Results: In the experiment 1, both the NECR and SNR were increased as radioactivity concentration getting increased. The NECR was shown as 53.7, 66.9, 91.4. and SNR was shown as 7.9, 10.0, 11.7. Both the NECR and SNR were increased in time-set method. But the count-set method's pattern was not similar with the time-set method. The NECR was shown as 53.8, 69.1, 97.8, and SNR was shown as 14.1, 14.7 14.4. The SNR was not increased in count-set method. In experiment 2, results of both the NECR and SNR were shown as 45.1, 70.6, 95.3, 115.6, 134.6, 162.2 and 7.1, 8.8, 10.6, 11.5, 12.7, 14.0. These results were shown similar patten with the experiment 1. Moreover, when the count-set method was applied, the NECR was shown as 42.1, 67.3, 92.1, 112.2, 130.7, 158.7, and SNR was shown as 15.2, 15.9, 15.6, 15.4, 15.5, 14.9. The NECR was increased but SNR was not shown same pattern. Conclusion: Increment of administered radioactivity improves the quality of image unconcerned with the pre-set method. However, NECR was not influenced by increment of total acquisition counts through simple increasing scan duration without increment of administered activity. In case of count-set method, the SNR was shown similar value despite of increment of radioactivity. So, the administered activity is more important than the scan duration. And we have to consider that evaluation of image quality using only SNR may not be appropriate.

  • PDF

Hydrophillic Interaction Chromatography-tandem Mass Spectrometry Method for Identification and Quantitation of 5-MeO-DIPT and its Metabolites in Rat Urine

  • Kim, Yoon;Kim, Un-Yong;In, Moon-Kyo;Lee, Jae-Ick;Kwon, Oh-Seung;Yoo, Hye-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.1158-1164
    • /
    • 2011
  • 5-Methoxy-N,N-diisopropyltryptamine (5-MeO-DIPT), a psychoactive tryptamine derivative, is a hallucinogenic drug of abuse. In this study, 5-OH-DIPT and its metabolites were identified and the quantitative method was developed and validated by using hydrophilic interaction chromatography-tandem mass spectrometry (HILICMS/MS). Chromatographic separation was achieved on an Atlantis HILIC silica column ($5{\mu}m$, $100{\times}2.1\;mm$). The metabolites of 5-MeO-DIPT in rat urine were characterized via Q1 scanning and product ion scanning. As a consequence, 5-MeO-IPT, 5-OH-DIPT, 6-OH-5-MeO-DIPT and their glucuronide conjugates were detected and identified as the metabolites of 5-MeO-DIPT. Subsequently, a quantitative method for 5-MeO-DIPT and its major metabolites, 5-MeO-IPT and 5-OH-DIPT, was developed in multiple reactions monitoring (MRM) mode. The calibration curves for all analytes evidenced good linearity over the concentration range of 1-1000 ng/mL with linear correlation co-efficients ($r^2$) in excess of 0.99. The intra- and inter-day accuracy and precision were 92.2-110.2% and 1.5-9.9%, respectively.

Analysis of Slot Coupled Stacked Microstrip Antennas (슬롯결합 적층 마이크로스트립 안테나 특성 해석)

  • 문호원;이정욱;윤영중;박한규
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.1
    • /
    • pp.37-47
    • /
    • 1995
  • In this paper, the slot coupled stacked microstrip antenna, which has wide bandwidth characteristics because of the double tuning effects from the interactions between two patches and feeding slot and improves distortions of radiation patterns due to spurious radiation from feeder, is analyzed. For the analy- sis Green function in the spectrum domain and Galerkin method is applied with an accurate analysis mode for slot coupled feeding structure using the scattering analysis method. The basis functions are 3 EB modes for patches and 5 PWS modes for feeder. The slot coupled stacked microstrip antennas are designed and fabricated with the center frequency of 11.5 Ghz and 12.0 GHz. The experimental results show the wide bandwidth characteristics of 1.9 ~ 2.2 GHz and agree well with the simulation results which have 15~20% bandwidth.

  • PDF

Gold-Silver mineals and the chemical environments of some gold-silver deposits, Republic of Korea(I) -Cheongju gold-silver mine- (한국(韓國) 일부(一部) 금(金)·은(銀) 광상(鑛床)에서 산출(産出)되는 금(金)·은(銀) 광물(鑛物)과 광상(鑛床)의 생성조건(生成條件)(I) -청주(淸州) 금(金)·은(銀) 광산(鑛山)-)

  • Lee, Hyun Koo;Choi, Jin Woo
    • Economic and Environmental Geology
    • /
    • v.21 no.3
    • /
    • pp.287-307
    • /
    • 1988
  • The Cheongju gold-silver mine is located at approximately $36^{\circ}28^{\prime}$north latitude and $127^{\circ}31^{\prime}$ east longitude in the Cheongju City of the Chung cheong bug Do, South Korea. Gold-Silver bearing hydrothermal quartz veins, occur in Cheongju Granit of Jurassic age. K-Ar isotope data for sericite in quartz vein indicate that the Au-Ag mineralization took place in early Cretaceous ($97.5{\pm}2.18$ MA. Park, et ai, 1986). Three stage of mineralization recognized anre, from early to later, (I) Sulide stage: pyrite, arsenopyrite, pyrrhotite (Hpo), sphalerite, chalcopyrite, electrum and quartz (II) Electrum stage: pyrite, sphalerite, galena, chalcopyrite, electrum and quartz. (III) Silver mineral stage: pyrite, marcasite, pyrrhotite (Mpo), sphalerite, galena, electrum, native silver argentite, fluorite, calcite and quartz. In this paper, mode of occurrences and chemical compositions of electum and native silver have been investigated by means of microscope and EPMA. Electron probe microanalysis shows that an individual grain of electrum is almost homogeneous in composition. Silver content of electrum ranges from 44.7-67.1 atom.%. Gold content of native silver ranges below 0.2 atom. %. Vicker's hardness number (VHN) of electrum and native silver ranges $78.2-81.8kg/mm^{2}$ respectively. The filling temperature of fluid inclusions in quartz ranges from $130-280^{\circ}C$. On the basis of arsenpyrite geothemometer, the equilibrium temperature and sulfur fugacity of the pyrite-arsenopyrite-pyrrhotite(Hpo) assemblage is assumed to be in ange from $300-310^{\circ}C$ and $10^{-10}$ to $10^{-11}$ atm. The estimated ore reserviors on Cheongju mine area are calculated to 8000 T/M, averaing 8.6g/t Au, 27.8 g/t Ag, 1.25% Pb, l.65% Zn.

  • PDF

A Study on Effect of Flex Additions for Selecting the Process Parameters in GMA Welding processes (GMA 용접공정에서 공정변수 선정을 위한 플럭스 첨가에 관한 연구)

  • Kim, In-Ju;Kim, Jun-Ki
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.17-22
    • /
    • 2011
  • As the quality of a weld joint is strongly influenced by process parameters the welding process, an intelligent algorithms that can predict the bead geometry and shape to accomplish the desired mechanical properties of the weldment should be developed. In this study, prepared by ${\Phi}1.6mm$ GMA welding of metal wire nose Advice jowelui 350A 600A grade level inverter welder and DAIHEN SCR's were carried out using welding. Welding conditions were 5.5m/min wire feed rate the welding current is rapidly transmit approximately 260A, welding voltage was about 30V. CTWD a 22mm, shielding gas was Ar 20L/min and the welding speed was a 240mm/min. Using data collected during welding equipment welding current and welding voltage waveform was analyzed by measuring the volume of the transition mode. Addition of $CaCO_3$ as a loss of the spread of the weld bead dilution rate decreased, suggesting that, GMA in the overlay welding bead shape control, dilution control and may be used as a welding flux is considered. Stabilizing effect of the arc by the Ca-containing $CaF_2$, $CaCO_3$, $CaMg(CO_3)_2$, respectively, welding flux 0.1wt.% added GMA welding and weld overlay were evaluated with dilution, $CaF_2$, and $CaMg(CO_3)_2$ added to the dilution of Seemed to increase.

Mode of Action of Water Soluble β-Glucan from Oat (Avena sativa) on Calorie Restriction Effect In-Vitro and In-Vivo Animal Models (In-Vitro, In-Vivo 동물모델에서 귀리 유래 수용성 베타-글루칸의 칼로리 제한 효과 작용기전 규명)

  • Kang, Hanna;Kim, Se-Chan;Kang, Yong Soo;Kwon, Young-In
    • The Korean Journal of Food And Nutrition
    • /
    • v.30 no.6
    • /
    • pp.1222-1228
    • /
    • 2017
  • In the current study, we investigated the inhibitory activity of water soluble ${\beta}-glucan$ from oat (Avena sativa) against various digestive enzymes such as ${\alpha}-glucosidase$, sucrase, maltase and glucoamylase. Inhibition of these enzymes involved in the absorption of disaccharide can significantly decrease the post-prandial increase of blood glucose level after a mixed carbohydrate diet. The ${\beta}-glucan$ had the highest documented rate of small intestinal sucrase inhibitory activity (2.83 mg/mL, $IC_{50}$) relevant for potentially managing post-prandial hyperglycemia. Furthermore, we evaluated the effects of ${\beta}-glucan$ on the level of post-prandial blood glucose in animal model. The post-prandial blood glucose levels were tested two hours after sucrose/starch administration, with and without ${\beta}-glucan$ (100, and 500 mg/kg-body weight). The maximum blood glucose levels (Cmax) of ${\beta}-glucan$ administration group were decreased by about 23% (from $219.06{\pm}27.82$ to $190.44{\pm}13.18$, p<0.05) and 10% (from $182.44{\pm}13.77$ to $165.64{\pm}10.59$, p<0.01) in starch and sucrose loading test, respectively, when compared to control in pharmacodynamics study. The ${\beta}-Glucan$ administration significantly lowered the mean, maximum, and minimum level of post-prandial blood glucose at 30 min after meal. In view of the foregoing, it is felt that our findings suggest that ${\beta}-glucan$ from oat serves to reduce post-prandial blood glucose rise secondary to slower absorption of glucose in the small intestine, via carbohydrate hydrolyzing enzymes inhibition.

High mobility indium free amorphous oxide based thin film transistors

  • Fortunato, E.;Pereira, L.;Barquinha, P.;Do Rego, A. Botelho;Goncalves, G.;Vila, A.;Morante, J.;Martins, R.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1199-1202
    • /
    • 2008
  • High mobility bottom gate thin film transistors (TFTs) with an amorphous gallium tin zinc oxide (a-GSZO) channel layer have been produced by rf magnetron cosputtering using a gallium zinc oxide (GZO) and tin (Sn) targets. The effect of the post annealing temperatures ($200^{\circ}C$, $250^{\circ}C$ and $300^{\circ}C$) was evaluated and compared with two series of TFTs produced at room temperature and $150^{\circ}C$ during the channel deposition. From the results it was observed that the effect of pos annealing is crucial for both series of TFTs either for stability as well as for improving the electrical characteristics. The a-GSZO TFTs operate in the enhancement mode (n-type), present a high saturation mobility of $24.6\;cm^2/Vs$, a subthreshold gate swing voltage of 0.38 V/decade, a turn-on voltage of -0.5 V, a threshold voltage of 4.6 V and an $I_{ON}/I_{OFF}$ ratio of $8{\times}10^7$, satisfying all the requirements to be used in active-matrix backplane.

  • PDF

Statistics of two-point correlation and network topology for Ly α emitters at z ≈ 2.67

  • Sungryong Hong;Arjun Dey;Kyoung-Soo Lee;Alvaro A Orsi;Karl Gebhardt;Mark Vogelsberger;Lars Hernquist;Rui Xue;Intae Jung;Steven L Finklestein;Sarah Tuttle;Michael Boylan-Kolchin
    • Monthly Notices of the Royal Astronomical Society
    • /
    • v.483 no.3
    • /
    • pp.3950-3970
    • /
    • 2019
  • We investigate the spatial distribution of Ly α-emitting galaxies (LAEs) at z ≈ 2.67, selected from the NOAO Deep Wide-Field Survey, using two-point statistics and topological diagnostics adopted from network science. We measure the clustering length, r0 ≈ 4 h-1 Mpc, and the bias, bLAE = 2.2+0.2-0.1. Fitting the clustering with halo occupation distribution (HOD) models results in two disparate possibilities: (1) where the fraction of central galaxies is <1 per cent in haloes of mass >1012 M and (2) where the fraction is ≈20 per cent. We refer to these two scenarios as the 'Dusty Core Scenario' for Model#1, since most of the central galaxies in massive haloes are dead in Ly α emission, and the 'Pristine Core Scenario' for Model#2, since the central galaxies are bright in Ly α emission. Traditional two-point statistics cannot distinguish between these disparate models given the current data sets. To overcome this degeneracy, we generate mock catalogues for each HOD model using a high-resolution N-body simulation and adopt a network statistics approach, which provides excellent topological diagnostics for galaxy point distributions. We find three topological anomalies from the spatial distribution of observed LAEs, which are not reproduced by the HOD mocks. We find that Model#2 matches better all network statistics than Model#1, suggesting that the central galaxies in >1012 h-1 M haloes at z ≈ 2.67 need to be less dusty to be bright as LAEs, potentially implying some replenishing channels of pristine gas such as the cold mode accretion.