• Title/Summary/Keyword: Korean winter temperature

Search Result 1,908, Processing Time 0.029 seconds

A Study on the Change of Wind Speed in South Korea: In Case of January and August (한국에서 풍속 변화에 관한 연구 -1월과 8월을 대상으로-)

  • Lee, Seung-Ho
    • Journal of the Korean Geographical Society
    • /
    • v.47 no.3
    • /
    • pp.347-358
    • /
    • 2012
  • This study aimed to investigate the change of wind speed during winter and summer seasons for 50 years(1961-2010). It were analyzed the mean wind speed, maximum wind speed, windy days and storm days on January and August of 13 weather stations in South Korea. The mean wind speed was decreased in the coastal region(Busan, Jeju, Ulsan, Pohang) in winter and summer seasons. Also it was similar to windy day. The relationship between wind speed and mean temperature has negative correlation in winter season. The relationship is low in summer season. The number of windy day and storm day has negative relation with monthly mean temperature.

  • PDF

A Study on Performance of Solar Thermal System for Domestic Hot Water According to the Weather Conditions and Feedwater Temperatures at Different Locations in Korea (지역별 기상조건과 급수온도에 따른 태양열 온수공급 시스템 성능에 관한 연구)

  • Sohn, Jin Gug
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.41-54
    • /
    • 2019
  • The purpose of this study is to analyze the performance of solar thermal system according to regional weather conditions and feedwater temperature. The performance analysis of the system was carried out for the annual and winter periods in terms of solar fraction, collector efficiency and it's optimal degree. The system is simulated using TRNSYS program for 6 cities, Seoul, Incheon, Gangneung, Mokpo, Gwangju, and Ulsan. Simulation results prove that the solar fraction of the system varies greatly from region to region, depending on weather conditions and feedwater temperatures. Monthly average solar fraction for winter season from November to February, a time when heat energy is most required, indicated that the highest is 73.6% in Gangnueng and the lowest is 56.9% in Seoul. This is about 30% relative difference between the two cities. On the other hand, the collector efficiency of the system for all six cities was analyzed in the range between 40% and 42%, indicating small difference compare to the solar fraction. The annual average solar fraction is rated the highest at 40 collector degree, while monthly average solar fraction during winter season is rated at 60 degree.

Indoor Environmental Efficiency Indoor Garden in Apartment House during Winter (아파트 실내정원의 겨울철 실내온열환경 조절효과)

  • Kim, Jeong-Min;Choi, Yoon-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.05a
    • /
    • pp.212-216
    • /
    • 2005
  • The purpose of this study is to make clear the indoor thermal environmental efficiency of indoor garden in apartment during winter. The questionnaire survey was carried out during the l0th${\sim}$20th of February 2004, respondents consisted of 215 residents living in a subject apartment estate. The field measurements of indoor thermal elements were carried out at A house with indoor garden and at B house without indoor garden. The measurements in two-subject houses were taken on simultaneously the 11th of February. As Results, the residents living in apartments with indoor garden show positive response on air moisture and satisfaction. The daily ranges of indoor temperature and globe temperature in the A house were narrower than the B house. The average relative humidity in the A house was higher and constant than the B house. Therefore, it was seemed that indoor environment during winter in the house with indoor garden maintained more constant or comfortable than the house without indoor garden by earning effect and humidity control effect of plants.

  • PDF

Characteristics of Nutrients Distribution in Summer and Winter in the South Sea (여름과 겨울철 남해의 영양염 분포 특성)

  • Lee, Tong-Sup
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.4
    • /
    • pp.371-382
    • /
    • 1999
  • This paper presents the results of recent nutrients measurement and analysis in relation to other environmental parameters such as temperature, salinity, AOU and pH in the South Sea, Korea. In summer, temperature showed stronger correlation with nutrients than salinity and also did the parameters related to biological activities such as pH and AOU. Implications of above results exemplify that primary producers in the vicinity of salt front actively consumed nutrients so that nutrients-salinity correlation is strongly modified in the salt front. Nutrient in winter showed significant correlation only with temperature. Nutrient distribution seems governed by the location of thermal front between vertically mixed cold water in northern area and warm waters flowing north. Due to weak biological activity in winter pH-nutrients correlation, which was strongest in summer ($R^2$ >0.6) dropped sharply in winter ($R^2$ <0.5). Depth integrated nitrate+nitrite, phosphate and silicate values are 321 $mmol{\cdot}m^{-2}$, 23 $mmol{\cdot}m^{-2}$, 637 $mmol{\cdot}m^{-2}$ in summer and 261 $mmol{\cdot}m^{-2}$, 31 $mmol{\cdot}m^{-2}$, 742 $mmol{\cdot}m^{-2}$ in winter, respectively. NIP values in summer exhibit phosphorus deficiency, however, winter situation is reversed for nitrogen. Nitrogen input via precipitation and riverine discharge in wet season seems potentially critical for maintaining the South Sea ecosystem.

  • PDF

Evaluation of Floor Heating Performance and Design Criteria for Operating an Outdoor Swimming Pool During Winter : A Case Study (동절기 옥외 수영장 시설의 운영을 위한 바닥난방 성능평가 및 설계기준에 관한 사례연구)

  • Cho, Jinkyun;Woo, Kyunghun;Kim, Jin-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.289-296
    • /
    • 2017
  • This study aimed to analyze the deck floor heating system of an outdoor swimming pool in terms of the thermal capacity/output and the surface temperature distribution based on the outdoor temperature, to design for anti-freezing during winter. Through the transient heat transfer simulation with PHYSIBEL and theoretical equations, the surface temperature distribution of the floor heating system at two outdoor conditions in Jeju, were calculated and evaluated. The results indicate that the specific thermal output required for maintaining $4^{\circ}C$ surface temperature at the design outdoor temperature of $0.1^{\circ}C$, was about $90W/m^2$. This performance analysis can be applied for future design criteria, including optimizations of system capacity and size.

TEMPORAL AND SPA TIAL VARIATION OF NIGHTTIME FISHING GROUND DERIVED FROM SATELLITE IMAGERY

  • Kim Sang-Woo;Jeong Hee-Dong;Suh Young-Sang;Go Woo Jin;Jang Lee-Hyun
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.437-440
    • /
    • 2005
  • We examined the relationship between the 50m temperature estimated by remote sensing sea surface temperature (SST) and fishing ground (squid fishing ground) detected by nighttime visible channel defense meteorological satellite program (DMSP) I operational linescan system (OLS) images in the East/Japan Sea during 1993-2000. The results are as follows: The numbers of nighttime fishing boat were distributed the highest in October, and the lowest in April during this study. A nighttime fishing grounds have concentrated in the East Korea Warm Current region, coastal regions of Honshu Island, and Polar front region. Fishing grounds have distributed $11-18^{\circ}C$ of estimated 50m temperature from the satellite data. Relationship between estimated 50m temperature and the distributed fisheries boats showed that the north boundaries of fishing grounds have distributed the temperature of below $12^{\circ}C$ from 1996 to 2000 and that of $13-15^{\circ}C$ during 1993-1995 and 1997-1999. Stable fishing grounds appeared near the Korea/Tsushima Strait from January to March. The center of fishing grounds in spring (April-Jun) have moved to the northward than that in winter, and variations appeared largely in winter. In summer (July-September), center of fishing grounds have formed near the Uleung Island in the south east coast of Korea, and in autumn maximum fishing ground appeared in October, the fishing ground southward from November.

  • PDF

Characteristics of Seasonal Mean Diurnal Temperature Range and Their Causes over South Korea (우리나라에서 계절별 일교차의 분포 특성과 그 원인)

  • Suh, Myoung-Seok;Hong, Seong-Kun;Kang, Jeon-Ho
    • Atmosphere
    • /
    • v.19 no.2
    • /
    • pp.155-168
    • /
    • 2009
  • Characteristics of seasonal mean diurnal temperature range (DTR) and their causes over South Korea are investigated using the 60 stations data of Korea Meteorological Administration from 1976 to 2005. In general, the seasonal mean DTR is greatest during spring (in inland area) and least during summer (urban and coastal area). The spatial and seasonal variations of DTR are closely linked with the land surface conditions (especially vegetation activity and soil moisture) and atmospheric conditions (cloud amount, precipitation, local circulation). The seasonal mean DTR shows a decreasing trend at the major urban areas and at the north-eastern part of South Korea. Whereas, it shows an increasing trend at the central area of the southern part. Decreasing and increasing trends of DTR are more significant during summer and fall, and during spring and winter. The decrease (increase) of DTR is mainly caused by the stronger increase of daily minimum (maximum) temperature than daily maximum (minimum) temperature. The negative effects of precipitation and cloud amount on the DTR are greater during spring and at the inland area than during winter and at the coastal area. And the effect of daytime precipitation on the DTR is greater than that of nighttime precipitation.

A Study on Inversion at Leeward Side of High-rise Building in Winter (동절기 고층건물 풍하면의 기온역전에 관한 연구)

  • Zheng, Hai-Yan;Jin, Wen-Cheng;Oh, Sung-Nam;Lee, Kyoo-Seock
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.6
    • /
    • pp.583-590
    • /
    • 2010
  • To determine nocturnal inversion characteristics at the leeward side of high-rise building, air temperature data were observed at 10 minute interval from February 22, 2010 to April 15, 2010. The observed data were compared, analyzed and examined to illustrate air temperature differences between the roof (XAR) and surface (XAG) of X apartment. The wind speed, wind direction and precipitation data were also observed at XAR and YJL (Yangjae Stream) sites at the same time. After the analysis, the maximum nocturnal inversion was observed by $4.0^{\circ}C$ at 3:40, 3:50, 4:10 on February 24th 2010, at that time the weather condition was clear and weak wind. Air temperature inversions at the leeward side of high-rise building were observed on whole day in wintertime and air temperature inversion intensity was also higher than other nearby area (SMG).

ON THE GENERATION OF TEMPERATURE INVERSIONS IN THE UPPER LAYER OF THE OCEAN (해양 표층 수온 역전의 원인)

  • Kang, Yong Q.
    • 한국해양학회지
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 1983
  • Oceanic temperature inversions, with unstable stratifications, are frequently founed in the surface layer of a few tens meters in the Japan Sea and the Yellow Sea in Winter. Mechanisms responsible for the generation of temperature inversions include the followings: (1) The nat heat loss at the sea suface requires an upward transport of heat from the interior of the ocean y convection, and this convection leads to the temperature inversions. (2) The downward propagation of the annual variation of the sea surface timperature, with an exponential decrease of amplitude and a linear change of phase with depth, generates the surface inversion layer in winter. (3) The cold water cdvection by Ekman drift, of which magnitude decreases exponentially with depth, generates temperature inversions for the three possible mechanisms mentioned above.

  • PDF

Railway Switching Point Heating System Using the Photovoltaic-Wind Power Hybrid (태양광-풍력 하이브리드를 이용한 철도 선로전환기 융설 장치 구현)

  • Kim, Dae-Nyeon;Park, Han-Eol;Kim, Deok-Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.136.1-136.1
    • /
    • 2011
  • This paper proposes the method to implement the railroad switching point heating system using the hybrid of the photovoltaic and wind power. The goal of the implementation of the railroad switching point heating system is to prevent freezing of the snow in the winter. The heating system of railway used to supply electricity through photovoltaic and wind power to prevent freezing. Hot wires of the railroad switching point heating system are used about 2kW of electric energy at the day. The electric energy of 2kW used the length of the hot wires about 3m. As the ON and/or OFF mode considering the tracks temperature and the ambient temperature, so the way the use of power-saving effect. In addition, the system can be used the railroad switching point heating system in winter and railway signal and street lights around the track in summer. In experiment, we acquired the power data according to time at the day of photovoltaic and wind power. We confirmed the temperature rise using the heating cable for 3m of $85^{\circ}C$, 30W/m. The temperature rise of the heating cable changes the temperature of $5^{\circ}C$ after 10 minutes and $11^{\circ}C$ after 10 minutes. We have confirmed the possibility of the railroad switching point heating system using the hybrid of the photovoltaic and wind power.

  • PDF