• Title/Summary/Keyword: Korean veterans

Search Result 506, Processing Time 0.026 seconds

Implant placement in severely atrophic mandible using alveolar ridge splitting procedure and small block bone graft: A case report of 4-year follow-up (심하게 위축된 하악 구치부에 치조제 분할술과 블록형 골이식술을 이용한 임플란트 식립: 4년 관찰 증례보고)

  • Kim, Na-Hong;Bang, Joo-Hyuk;Lee, Dong-Woon
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.64-73
    • /
    • 2019
  • Various techniques have been developed, and the development of piezo electric devices have made it possible to widen the alveolar ridge even if the residual bone is dense or if there is a lack of cancellous bone between the cortical bones. In the operation of the mandibular posterior area, the flap is easily accessible to the ramus bone, from which high quality autogenous bone can be obtained, compared to other parts. A small autologous bone block can be used with particulated bone graft material using one screw for bone regeneration instead of a large autologous bone with two screws. The tapered implant design can minimize buccal bone fracture, even in severely atrophic mandibular areas. We report a case of 4 years following implant placement with ridge splitting and small autogenous bone graft in severly atrophic mandible. This report demonstrates a case of functional and aesthetic restoration in a patient through a collaboration.

The Effect of Hand Reflexology on Pain, Skin Temperature and Nursing Practice (입원 환자에서 손 반사요법의 통증, 피부체온 및 간호실무 효과)

  • Ha, Hyae-Chung;Lee, Young-Soon;Kim, Dong-Soo;Lee, Myung-Sook;Oh, Sei-Young
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.12 no.2
    • /
    • pp.178-186
    • /
    • 2006
  • Purpose: This study is aimed to examine the effectiveness on pain, feeling and nursing practice of hand reflexology applied to in-patient in the clinical setting. Method: The pre/post test methods using VAS for pain and feeling, physiologic measuring, and questionnaire of nursing care were conducted. Subjects were selected 45 in-patients from a surgical ward in hospitals during Nov.-Dec. 2005. 5 minute hand reflexology therapy was applied to both hands of participant by two research assistants at the same time. Data were analyzed based on SAS program using frequency, $x^2$-test, paired t-test, ANOVA and Pearson's correlation coefficients. Result: 1. After receiving hand reflexology therapy, the subjects showed significant pain relief(t=-4.94, p=.0001), improvement in feeling(t=19.44, p=0001) and an increase in skin temperature(t=3.54, p=.001). 2. The applied skills that the participants preferred were press-rotate(80.0%), press-walk(35.56%) and press-rolling(31.11%). The effectiveness of nursing practice scored $3.99{\pm}1.97$ out of 5. Nurse-Patient Relationship and effective response of nursing intervention ranked the highest 4.31. Conclusion: Hand reflexology was considered as an effective nursing intervention in the clinical settings, but in order to evaluate re-verifies and reliances for this effects, it is necessary that comparative studies should be conducted.

  • PDF

The retrospective study of survival rate of implants with maxillary sinus floor elevation (상악동 거상술을 동반한 임플란트 식립 후 생존율에 대한 후향적 연구)

  • Yu, Jeoung-A;Lee, Sang-Min;Yoo, Mi-Kyung;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Park, Pil-Kyoo;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.293-301
    • /
    • 2009
  • Purpose: The purpose of this study is to show the total survival rate of implants with maxillary sinus floor elevation and the effects that reach the survival rate by classifying types of graft materials, implant surface, operation method, bone height. Methods: In a total of 131 patients, 251 implants with sinus floor elevation were installed simultaneously or after regular healing. Various bone grafts (autograft, xonograft, allograft, alloplast) and implant surface (MTX-HA implant, chemical etching implant, Titanium oxide surface implant, resorbable blasting media implant, resorbable blast texturing implant, HA-coated implant) were used. All implants were investigated clinically and radiographically, being with 1 to 5 years follow-up period after installation. Results: The survival rate of 251 implants with maxillary sinus floor elevation was 94%. The types of implant, surface, graft material, bone height have no statistically signi-ficant differencies. Conclusions: It can be suggested that maxillary sinus floor elevation may have predictable result with various bone graft materials and implant surface.

Theoretical axial wall angulation for rotational resistance form in an experimental-fixed partial denture

  • Bowley, John Francis;Kaye, Elizabeth Krall;Garcia, Raul Isidro
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.278-286
    • /
    • 2017
  • PURPOSE. The aim of this study was to determine the influence of long base lengths of a fixed partial denture (FPD) to rotational resistance with variation of vertical wall angulation. MATERIALS AND METHODS. Trigonometric calculations were done to determine the maximum wall angle needed to resist rotational displacement of an experimental-FPD model in 2-dimensional plane. The maximum wall angle calculation determines the greatest taper that resists rotation. Two different axes of rotation were used to test this model with five vertical abutment heights of 3-, 3.5-, 4-, 4.5-, and 5-mm. The two rotational axes were located on the mesial-side of the anterior abutment and the distal-side of the posterior abutment. Rotation of the FPD around the anterior axis was counter-clockwise, Posterior-Anterior (P-A) and clockwise, Anterior-Posterior (A-P) around the distal axis in the sagittal plane. RESULTS. Low levels of vertical wall taper, ${\leq}10-degrees$, were needed to resist rotational displacement in all wall height categories; 2-to-6-degrees is generally considered ideal, with 7-to-10-degrees as favorable to the long axis of the abutment. Rotation around both axes demonstrated that two axial walls of the FPD resisted rotational displacement in each direction. In addition, uneven abutment height combinations required the lowest wall angulations to achieve resistance in this study. CONCLUSION. The vertical height and angulation of FPD abutments, two rotational axes, and the long base lengths all play a role in FPD resistance form.

The effects of a single-dose subacromial injection of a nonsteroidal anti-inflammatory drug in geriatric patients with subacromial impingement syndrome: a randomized double-blind study

  • Kim, Youngbea B;Lee, Woo-Seung;Won, Jun-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.1
    • /
    • pp.4-8
    • /
    • 2021
  • Background: As nonsteroidal anti-inflammatory drugs (NSAIDs) and steroids have similar effects, steroids can be avoided to reduce adverse effects. This study aimed to compare the differences in symptom improvement after subacromial injection of steroids or NSAIDs. Methods: Sixty patients with rotator cuff syndrome for at least 3 months were enrolled and divided into steroid and NSAID groups. The steroid group received a mixture of 1 mL of triamcinolone acetonide (40 mg/mL) and 1 mL of lidocaine hydrochloride 2%, while the NSAID group received a mixture of 1 mL of Ketorolac Tromethamine (30 mg/mL) and 1 mL of lidocaine hydrochloride 2%. The patients were assessed before and at 3, 6, and 12 weeks after the procedure. Shoulder scores from visual analog scale (VAS), American Shoulder and Elbow Surgeons (ASES), and University of California Los Angeles (UCLA) were used for evaluation. Results: Both groups showed improvements in the clinical outcomes. Overall VAS, ASES, and UCLA scores improved from 6.9, 32.7, and 16.0 before the procedure to 2.0, 1.2, and 1.1; 81.5, 87.6, and 88.5; and 29.7, 31.8, and 32.0 at weeks 3, 6, and 12 weeks after the procedure, respectively. Twenty-six patients (86.7%) in the steroid group and 28 (93.3%) in the NSAID group reported satisfactory treatment outcomes. There were no significant differences in the outcomes between the two groups (p=0.671). Conclusions: Subacromial injection of NSAIDs for rotator cuff tendinitis with shoulder pain had equivalent outcomes with those of steroid injection at the 12-week follow-up.

Regenerative procedure using rotary titanium brush for surface decontamination of peri-implantitis: 3 cases with a 2-year follow-up (회전형 타이타늄 브러쉬를 이용한 임플란트 주위염 재생술식: 2년 추적결과 증례 보고)

  • Baek, Min-Woo;Yu, Jeoung-A;Choi, Seong-Ho;Lee, Dong-Woon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.259-267
    • /
    • 2021
  • Peri-implantitis, in which inflammation caused by plaque and biofilm on the implant surface spreads to the hard tissue, can be treated by decontamination of the implant surface and reconstruction of the lost hard tissue through surgical methods. We have described the management of 3 peri-implantitis cases by decontamination of the implant surface using a round titanium brush and regenerative therapy. All cases showed clinical improvements, and no further radiographic bone loss was observed during a 2-year follow-up. This treatment method can be effective for clinical improvement and bone regeneration. However, a longer follow-up period is necessary to support these outcomes.

Development of a Beam Source Modeling Approach to Calculate Head Scatter Factors for a 6 MV Unflattened Photon Beam

  • Park, So-Yeon;Choi, Noorie;Jang, Na Young
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.137-144
    • /
    • 2021
  • Purpose: This study aimed to investigate the accuracy of head scatter factor (Sc) by applying a developed multi-leaf collimator (MLC) scatter source model for an unflattened photon beam. Methods: Sets of Sc values were measured for various jaw-defined square and rectangular fields and MLC-defined square fields for developing dual-source model (DSM) and MLC scatter model. A 6 MV unflattened photon beam has been used. Measurements were performed using a 0.125 cm3 cylindrical ionization chamber and a mini phantom. Then, the parameters of both models have been optimized, and Sc has been calculated. The DSM and MLC scatter models have been verified by comparing the calculated values to the three Sc set measurement values of the jaw-defined field and the two Sc set measurement values of MLC-defined fields used in the existing modeling, respectively. Results: For jaw-defined fields, the calculated Sc using the DSM was consistent with the measured Sc value. This demonstrates that the DSM was properly optimized and modeled for the measured values. For the MLC-defined fields, the accuracy between the calculated and measured Sc values with the addition of the MLC scatter source appeared to be high, but the only use of the DSM resulted in a significantly bigger differences. Conclusions: Both the DSM and MLC models could also be applied to an unflattened beam. When considering scattered radiation from the MLC by adding an MLC scatter source model, it showed a higher degree of agreement with the actual measured Sc value than when using only DSM in the same way as in previous studies.

Effects of coffee intake on airway hypersensitivity and immunomodulation: an in vivo murine study

  • Ying-Chi Wong;Wen-Cheng Hsu ;Tzee-Chung Wu ;Ching-Feng Huang
    • Nutrition Research and Practice
    • /
    • v.17 no.4
    • /
    • pp.631-640
    • /
    • 2023
  • BACKGROUND/OBJECTIVES: Coffee is a complex chemical mixture, with caffeine being the most well-known bioactive substance. The immunomodulatory and anti-inflammatory properties of coffee and caffeine impact health in various aspects, including the respiratory system. The objective is to investigate the effects of coffee and caffeine on airway hyperresponsiveness and allergic reactions, as well as to analyze and compare associated cytokine profiles. MATERIALS/METHODS: BALB/c mice were intraperitoneally sensitized with ovalbumin (OVA) and given OVA inhalation to induce airway hypersensitivity. Two weeks after sensitization, they were intragastrically gavaged with coffee or caffeine, both containing 0.3125 mg caffeine, daily for 4 weeks. Control mice were fed with double-distilled water. Serum OVA-specific antibody levels were measured beforehand and 5 weeks after the first gavage. Airway hyperresponsiveness was detected by whole body plethysmography after gavage. Cytokine levels of bronchoalveolar lavage and cultured splenocytes were analyzed. RESULTS: Coffee effectively suppressed T helper 2-mediated specific antibody response. Airway responsiveness was reduced in mice treated with either coffee or caffeine. Compared to the control, coffee significantly reduced OVA-specific immunoglobulin (Ig) G, IgG1 and IgE antibody responses (P < 0.05). Caffeine also attenuated specific IgG and IgG1 levels, though IgE level was unaffected. Coffee significantly reduced interleukin (IL)-4 and increased IL-10 concentration in spleen cells and bronchoalveolar lavage fluid (P < 0.05). CONCLUSIONS: Coffee effectively attenuated airway hyperresponsiveness and systemic allergic responses induced by OVA food allergen in mice. As a complex composition of bioactive substances, coffee displayed enhanced immunomodulatory and anti-inflammatory effects than caffeine.

Comorbid Conditions in Persons Exposed to Ionizing Radiation and Veterans of the Soviet-Afghan War: A Cohort Study in Kazakhstan

  • Saule Sarkulova;Roza Tatayeva;Dinara Urazalina;Ekaterina Ossadchaya;Venera Rakhmetova
    • Journal of Preventive Medicine and Public Health
    • /
    • v.57 no.1
    • /
    • pp.55-64
    • /
    • 2024
  • Objectives: This study investigated the prevalence and characteristics of comorbid conditions in patients exposed to ionizing radiation and those who were involved in the Soviet-Afghan war. Methods: This study analyzed the frequency and spectrum of morbidity and comorbidity in patients over a long-term period (30-35 years) following exposure to ionizing radiation at the Semipalatinsk nuclear test site or the Chornobyl nuclear power plant, and among participants of the Soviet-Afghan war. A cohort study, both prospective and retrospective, was conducted on 675 patients who underwent comprehensive examinations. Results: Numerical data were analyzed using the Statistica 6 program. The results are presented as the mean±standard deviation, median, and interquartile range (25-75th percentiles). The statistical significance of between-group differences was assessed using the Student t-test and Pearson chi-square test. A p-value of less than 0.05 was considered statistically significant. We found a high prevalence of cardiovascular diseases, including hypertension (55.0%) and cardiac ischemia (32.9%); these rates exceeded the average for this age group in the general population. Conclusions: The cumulative impact of causal occupational, environmental, and ultra-high stress factors in the combat zone in participants of the Soviet-Afghan war, along with common conventional factors, contributed to the formation of a specific comorbidity structure. This necessitates a rational approach to identifying early predictors of cardiovascular events and central nervous system disorders, as well as pathognomonic clinical symptoms in this patient cohort. It also underscores the importance of selecting suitable methods and strategies for implementing treatment and prevention measures.

The Differences between Fixation Devices for Proximal Chevron Osteotomy in Hallux Valgus Surgery (무지 외반증의 근위 갈매기형 절골술 후 고정 방법에 따른 결과 차이)

  • Kim, Taik-Seon;Kang, Kyu-Bok;Kang, Jong-Woo;Kim, Hak-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.26-30
    • /
    • 2008
  • Purpose: The authors evaluated the differences between K-wires and Bold screw for fixing the proximal metatarsal chevron osteotomy of moderate and severe hallux valgus. Materials and Methods: There were 59 patients (81 feet) who were moderate and severe degree hallux valgus according to the classification of Mann. They all got the proximal chevron osteotomy when correcting the deformity. All patients were followed up at least 6 months. We divided the patients into 2 groups, K-wires fixed group as A, Bold screw fixed group as B. Group A were 42 patients (63 feet) and Group B were 18 patients (19 feet). Among the Group B, 2 feet who were failed to fix the oetotomy site with Bold screw, were fixed with K-wires during operation. We measured the AOFAS score preoperatively, postoperatively and at final follow-up, VAS score at 2 weeks after the operation. Also preoperative, postoperative and follow-up hallux valgus angle (HVA) and intermetatarsal angle (IMA) were measured for each patients. Results: Mean follow up period was 1.34 year (range: 6 months-6.16 years). Mean VAS score of group A was $3.21{\pm}1.7$ and group B $1.76{\pm}1.0$. Preoperative mean AOFAS score of group A was $45.61{\pm}8.3$, group B $44.41{\pm}8.9$, the final mean score of group A was $88.87{\pm}8.3$ and group B $92.47{\pm}4.4$. Preoperative mean HVA was $30.82{\pm}6.6$ degrees in group A and $32.88{\pm}14.5$ degrees in group B, the final mean angle of group A was $14.89{\pm}8.3$ degrees and group B $17{\pm}4.4$ degrees. The preoperative mean IMA of group A was $13.69{\pm}3.6 $degrees and group B $12.35{\pm}5.2$, the final mean angle of group A was $9.26{\pm}3.6$ degrees and group B $12.35{\pm}5.8$ degrees. Conclusion: There were no statistical differences in radiologic and clinical results (p>0.05) but, group B exceeded group A in VAS score (p=0.0007) and had no statistical significance in terms of reduction angle loss (p=0.06). Early returning to normal life activity may be possible for patients using Bold screws.

  • PDF