• Title/Summary/Keyword: Korean official test methods

Search Result 51, Processing Time 0.032 seconds

Examination of the Chemical Tests for Herbal Medicines Listed in the Official Drug Compendia(Pharmacopoeia and Natural Drug Standards) of Korea (한(韓) 중(中) 일(日)의 공정서(公定書)(약전(藥典) 및 규격집(規格集))에 수재(收載)된 전통천연약물(傳統天然藥物)의 품질(品質)에 관한 조사(調査)(II) -대한약전(大韓藥典) 및 대한약전외(大韓藥典外) 한약(韓藥)(생약)(生藥) 규격집(規格集)의 확인시험법(確認試驗法)에 대한 검토(檢討)-)

  • Park, Sang-Hi;Youm, Jeong-Rok;Chang, Il-Moo
    • Korean Journal of Pharmacognosy
    • /
    • v.22 no.2
    • /
    • pp.124-127
    • /
    • 1991
  • In the preceding paper, it was reported that total 63 traditional Korean herbal medicines listed in the Korean Pharmacopoeia and Korean Natural Drug Standards were found to be different plants in terms of systematic botany when those were compared with other two countries' drug compendia, Chinese Pharmacopoeia, Japanese Pharmacopoeia and Japanese Natural Drug Standards. Among 63 traditional Korean herbal drugs, 28 items were subject to the chemical identification test by using official methods that are described in the Korean Pharmacopoeia and the Korean Natural Drug Standards. In addition, 5 items were also tested by using the official methods described in Chinese and Japanese drug compendia, since there are no official chemical tests available in the Korean drug compendia. It was found that most of chemical tests appeared to be suitable. It was noted that the chemical test for Atractylodis Rhizoma(蒼朮) was incorrect and unapplicable. Those chemical tests for Clematidis Radix(威靈仙), Rubi Fructus(覆盆子) and Viticis Fructus(蔓荊子) are desirable to be revised for more accurate identification.

  • PDF

Term Structure Estimation Using Official Rate

  • Rhee, Joon Hee;Kim, Yoon Tae
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.3
    • /
    • pp.655-663
    • /
    • 2003
  • The fundamental tenn structure model is based on the modelling of the short rate. It is well-known that the short rate depends on the interest rate policy of monetary authorities, especially on the official rate. Babbs and Webber(1994) modelled the tenn structure of interest rates using the official rate. They assume that the official rate follows a jump process. This reflects that the official rate infrequently changes. In this paper, we test this official tenn structure model and compare the jump-diffusion model with the pure diffusion model.

A Study on the pH Characteristic of Recycle Aggregate According to Test Methods and Elapsed Time (측정방법 및 시간경과에 따른 순환골재의 pH 특성에 관한 연구)

  • Song, Tae-Hyeob;Lee, Jong-Chan;Lee, Sae-Hyun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.61-68
    • /
    • 2011
  • The pH of recycled aggregate is over 12 because of high alkalinity of cement. This high alkalinity give circumstance harmful effect. The high alkalinity of recycled aggregate can appear variously according to aggregate properties, elution time of alkalinity, aggregate size, and so on. This study analyzed recycled aggregate properties according to wet and dry type manufacture process; different test methods: waste official test, soil contamination official test, BS EN 1744-3 standard; elution time and different size to test effects of various condition. These test results can contribute to solving environmental problems by recycled aggregate. In the test results, pH of recycled aggregate was as higher as smaller particle size and as time elapsed. There was no difference between dry and wet type recycled aggregate except for difference according to elapsed time. Waste official test method got the highest pH value between pH test methods. So unified pH test method need to test recycled aggregate pH.

  • PDF

Certification and Quality Control of the Official Test Facilities of Dioxins in Korea (국내 다이옥신 측정분석기관 지정 및 정도관리)

  • Jang, Seong-Ki;Kim, Tae-Seung;Lee, Won-Seok;Chung, Young-Hee;Choi, Doug-Il
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.675-682
    • /
    • 2000
  • The concentration of dioxins from flue gases of municipal waste incineration facilities with capacities over 50 tons/day are regulated by the guideline: $0.1ng-TEQ/Nm^3$ for new facilities, and $0.5ng-TEQ/Nm^3$ for existing facilities and it will be strengthened to $0.1ng-TEQ/Nm^3$ until 2003 year. Dioxins from these incineration facilities have to be measured more than 2 times annually by the Official Test Facilities of Dioxins. Seven institutions have been certified so far as the Official Test Facilities of Dioxins. These facilities have to be evaluated by the quality control program provided by National Institute of Environmental Research every year. We reported the results of quality control test performed in 1999. Four institutions certified in 1998 sampled flue gases at stack of M incineration facilitiy and analyzed dioxins by Official Methods of Air Pollution. The isokinetic coefficients, the parameter for evaluation of sampling ability were excellent for all four institutions. They were 100.9%, 102.4%, 102.1% and 99.2%, respectively. The criteria required are as follows; resolution over 10,000, mass calibration within ${\pm}5ppm$, ion abundance ratio within 15%, and the recovery of 50-120%. As results, those institutions also met these parameters of Official Method of Air Pollution.

  • PDF

Temporal Variation of Indoor Air Quality in Daycare Centers (어린이집에서 이산화탄소와 미세먼지의 장기간 시간적인 변이를 활용한 실내환경수준 평가)

  • Kim, Yoonjee;Lee, Sewon;Ban, Hyunkyung;Cha, Sangmin;Kim, Geunbae;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.4
    • /
    • pp.267-272
    • /
    • 2017
  • Objectives: The purposes of the study were to analyze the temporal variation of carbon dioxide ($CO_2$) and particulate matter (PM) in daycare centers and evaluate the appropriateness of the official test method of one-time measurement. Methods: Indoor air quality in 46 daycare centers in the Seoul Metropolitan Area was measured as specified in the official test method of Indoor Air Quality Management law. In addition, indoor air quality in the 46 daycare centers was measured over 37 days using a real-time monitor (AirGuard K). Results: The daily means of $CO_2$ and PM in the 46 daycare centers were $1042.74{\pm}134.45ppm$ and $67.60{\pm}18.25{\mu}g/m^3$, respectively. Indoor air quality in the daycare centers showed significant temporal fluctuation. Measurements for single days were significantly different from the 37-day average exposure. Relative error of short term exposure decreased with an increase in the number of sampling days. The noncompliance rate for $CO_2$ using the official testing method was 2.17%, and none exceeded the $PM_{10}$ standard of $100{\mu}g/m^3$. With monitoring over 37 days, the daily noncompliance rate for $CO_2$ was 50.4% and the daily noncompliance rate for PM was 13.8%. Conclusions: When the official test method evaluates the indoor air at daycare centers one day per year, the results may not represent actual indoor air quality over a longer period of time. Real-time monitoring devices could be an alternative for managing indoor air quality.

Improving Detection Method of Pseudomonas aeruginosa, an Important Index Organism of Bottled Water Quality (먹는샘물의 녹농균 분포 및 검사방법 개선에 관한 연구)

  • 정현미;김동빈
    • Korean Journal of Microbiology
    • /
    • v.36 no.3
    • /
    • pp.242-248
    • /
    • 2000
  • Since the official allowance of bottled water at Korean domestic market in 1995, Pseudomo~zas aemginosu has been detected from 2.3% and 1.2% of source and products of bottled water sa~nple tested, respectively. according to the nation-wide dala froin May 1995 to December 1996. Therefore, P aeivginosa was the second most important parameter, next to colifoi~ns, anlong the bacieriological parameters regulated for bonled water. The official standard method initially adopted the Japanese officlal method and Standard Methods of the US, w~hich is using aspai-agiii-acetamid mnedia(A-A method). how eve^; the method showed low specificity regardless of the high sensitivity. The $42^{\circ}C$ growth test was the best biochemical featu1-e differentiating the P uelarginosu 6-om P aei-uginosa-like species such as P puririir and P Jhoi.escens amo1zg the other characierisiics such as fluorescence pigment_ pyocyanin, casein hy&olysis, etc. Thel-efore, addition of the $42^{\circ}C$ growth Lest in advance ofthe biochemical identification test, when sainple is positive by A-A method, should strengthen the spec~IiclQ w~tli ~ninin~um addition of testing load.

  • PDF

Analytical method of the polychlorinated biphenyls in soil using GC/ECD and GC/MS (GC/ECD 및 GC/MS을 이용한 토양 중 PCBs 분석방법 고찰)

  • Kim, Tae-Seung;Shin, Sun-Kyoung;Yoon, Jeong-Ki;Kim, Jong-Ha;Kim, Hyoung Seop;Lee, Jeong Ah
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.91-108
    • /
    • 2007
  • This study was investigated both the Korean official soil test method and the international various methods for PCBs in soil sample. The analytical guideline of PCBs in contaminated soil were proposed based on the official soil test methods by discussing the extraction, column cleanup, instrumental conditions, quantification methods of peak matching and individual isomers. The total 28 soil samples were selected by consideration of PCBs-contamination, land use etc., and then analyzed using gas chromatography/electron capture detection (GC/ECD) and gas chromatography/mass spectrometry(GC/MS). In this study, the PCBs were not detected as peak matching method using GC/ECD, but PCBs detected $0.002{\sim}0.487{\mu}g/kg$ using GC/MS in background concentrations.

Study on the unification between KS I ISO standard and official test method enacted by Korean Ministry of Environment - drinking water and indoor air quality - (환경오염공정시험기준과 KS ISO규격의 일원화에 관한 연구 - 먹는 물 및 실내공기질 -)

  • Lee, Jeong-Il;Lee, Ju-Hee;Lee, Jeong-Hee;Lee, Jun-Hee;Lee, Won-Seok;Kim, Ji-In;Kim, Bo-Kyung;Choi, Sung-Hun
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.102-113
    • /
    • 2012
  • Our study researched on unification of KS I ISO standard harmonized with ISO and Official Test Method enacted by Korean Ministry of Environment-drinking water and indoor air quality. We reviewed KS methods related to drinking water and indoor air quality for about 23,000 KS methods. KS methods related environmental field are classified as KS I, total 635 methods and 583 KS I methods were harmonized with ISO. For Environmental Standard methods for drinking water, 100 methods were reviewed according to 232 KS methods related to ISO/ TC 147 "Water Quality". Environmental Standard methods for indoor air quality were reviewed according to 95 KS standard methods related to ISO/TC 146 "Air Quality". By reviews and comparison tests for unifiable ES for drinking water and indoor air quality with KS methods harmonized with ISO, it was evaluated that for 100 ES methods for drinking water, 23 ES methods were unification complete, 29 ES methods were unification possible, 12 ES methods were unification impossible, no corresponding methods were found in KS I ISO for 36 ES methods and for 17 ES methods for indoor air quality,1 ES methods were unification complete, 3 ES methods were unification possible, 3 ES methods were impossible, no corresponding methods were found in KS I ISO for 10 ES methods.

A Research on Development of Eco-friendly Polyurethane Waterproofing Membrane Coating of Exposed Type (재활용 소재를 활용한 친환경 노출형 폴리우레탄 도막방수재 개발에 관한 연구)

  • Kim, Dong-Bum;Heo, Neung-Hoe;Oh, Je-Gon;Go, Gun-Woong;Go, Jang-Ryeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.161-162
    • /
    • 2014
  • The subject of this study, Eco-friendly Polyurethane Waterproofing Membrane Coating of Exposed Type is manufactured by replacing environmental hazardous substance such as Toluene, Dioctyl Phthalate with Dimethyl Carbonate, waste-soybean oil. As part of existing filler is also replaced with waste-rubber chip and waste-soybean oil. As a result of environment friendly tests, in test of detection of VOCs case was contented with the Ministry of Environment standards at 5% below. Testing methods for heavy metal extracted was contented with standards for official wastes test method. So it is judged that environment friendly is secured.

  • PDF