• Title/Summary/Keyword: Korean dual system

Search Result 1,904, Processing Time 0.037 seconds

Structure of Dual Polarized System for Wireless Communication (무선 통신을 위한 이중 편파 시스템 구조)

  • Kim, Jaekil;Gwak, Gye Seok;Ahn, Jae Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.8
    • /
    • pp.746-755
    • /
    • 2014
  • In this paper, we propose the structure of a dual polarized system for a wireless communication. The proposed dual polarized antenna is formed by one vertical antenna and two horizontal antennas that are orthogonal to each other. Vertical and horizontal polarized antennas transmit different signals, but two orthogonal horizontal polarized antennas transmit the same data signals. So, the signals of the proposed dual polarized system construct two dual-polarization planes. And, only one dual-polarization plane with a large signal power is selected at the side of a receiver. The simulation results show that the proposed dual polarized system could obtain a higher capacity compared to an ordinary $2{\times}2$ MIMO (Multi-input Multi-output) system.

Study on Dual-Lenses Actuator for HD-DVD System (차세대 DVD 시스템용 Actuator 연구)

  • Kim, Seok-Jung;Lee, Yong-Hoon;Ahn, Young-Man;Chung, Chong-Sam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.777-781
    • /
    • 2002
  • Recently, an optical disc system has been proposed using blue laser diode, high NA objective lens and groove only disc structure. A new method is needed to readout CD and DVD in this blue system. In order to readout CD and DVD in HD-DVD system, we adopted dual-lenses actuator in consideration of optical utilization efficiency, optical performance and insurance of sufficient W.D (working distance). This dual-lenses actuator has two objectives in radial direction, one is for CD/DVD and the other is for HD-DVD. We had to solve the induced problems of DC tilt increase, $2^{nd}$ resonance deterioration and AC sensitivity drop caused by disposing two lenses in an actuator. Especially, to solve AC sensitivity drop, we introduced two 2-pole magnets and separated focus and track magnetic circuits. Consequently we presented that dual-lenses actuator has been possessed good performance. And we measured eye patterns of CD, DVD and HD-DVD by using HD-DVD optical pick-up with dual-lenses actuator.

  • PDF

Calculation of Optimum Parameters on Dual Adsorption Isotherm System (등온이원흡착시스템에 있어서 최적 계수 산정)

  • 김홍성;최해욱
    • Textile Coloration and Finishing
    • /
    • v.11 no.5
    • /
    • pp.38-43
    • /
    • 1999
  • A calculation method of optimum parameters on dual adsorption isotherm system was examined. The optimum parameters were obtained by non-linear regression analysis based upon a limited solute concentration of dual adsorption isotherm. The results were analyzed with adducing experimental data of formerly reported treaties. The percentage mean deviation of dual adsorption equation calculated with optimum parameters was less than about 5% of experimental data, which was far less than results obtained with parameters of the adduced treatises.

  • PDF

Implementation of Dual Servoing Using a Linear Motor and a Piezoelectric Actuator (리니어모터 및 압전구동기를 이용한 이중서보의 구현)

  • Ahn, Hyun-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.249-252
    • /
    • 2002
  • For a precise position control with the resolution of a micrometer, a dual servo system is constructed using a linear motor and a piezoelectric actuator. The switching mode dual servo algorithm is implemented on a DSP board in which A/D and D/A converters are also mounted. It is shown by the experimental results that the precise position control is performed within a few micrometer of position error by using the dual servo system.

  • PDF

Investigation of Winding Connections for Fault-Tolerant of MW Class Offshore Wind Generator with Dual 3-Phase System and Modular (이중 3상 시스템과 모듈러를 갖는 MW급 해상용 풍력발전기의 무정지 기능을 위한 권선 체결방식에 관한 연구)

  • Seo, Jang Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1108-1114
    • /
    • 2013
  • This paper presents a new winding topology for MW class offshore wind generator having modular and dual 3-phase. Based on proposed simplified relationship between magnetic flux and phase current in the air gap, several new windings for modular and dual 3-phase are made. In case of one inverter operation or faulty operation, the proposed model can have balanced 3-phase induced voltage whereas the conventional generator with modular winding has unbalanced induced voltage, which can be important issue in offshore generator. The model was applied into 6MW prototype machine with dual 3-phase. Using finite element analysis, induced voltage, inductance were investigated. The results show that the proposed modular winding can be applicable to dual inverter system with electrically balanced voltage.

Analysis of Fatigue Safety for Anti-Loose Nuts System with Dual Nuts (이중너트가 적용된 풀림방지너트 시스템의 피로안전성 분석)

  • Choi, Jung-Youl;Kim, Jun-Hyung;Chung, Jee-Seung;Ka, Sang-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.22-27
    • /
    • 2017
  • In this study, the authors aim to evaluate a structural and fatigue safety of a new type anti-loose nut system with dual nuts composed of main nut and outer nut to enhance the long-term workability and durability so as to improve the performance of conventional anti-loose nut system. Also, a three-dimensional finite-element method analysis was performed to consider the actual geometry and material property of anti-loose nut system with dual nuts and the effect of static and dynamic loads and loading directions. The analytical results showed that the overall static and dynamic stress of the components of the anti-loose nut system with dual nuts were found to be less than that of the fatigue limit of Goodman-smith diagram and allowable stress of each materials, therefore the anti-loose nut system with dual nuts was sufficient to ensure a structural and fatigue safety.

Dual-plane Stereoscopic PIV Measurement on the Lobed Jet Mixing Flow

  • SAGA Tetsuo;KOBAYASHI Toshio
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.108-122
    • /
    • 2001
  • In a continuing effect to study the mixmg enhancement by large-scale streamwise vortices in lobed mixing flows, an advanced PIV system named as dual-plane stereoscopic PIV system was used in the present study to conduct simultaneous vorticity (all three components) measurement of an air jet exhausted from a lobed nozzle. Unlike 'classical' 2-D PIV system or conventional 'single-plane' stereoscopic PIV system, the dual-plane stereoscopic PIV system used in the present study can obtain the flow velocity (all three components) fields at two spatially separated planes simultaneously. Therefore, it can provide the distributions of all the three components of vorticity vectors instantaneously and simultaneously. The evolution and interaction characteristics of the large-scale streamwise vortices and azimuthal Kelvin-Helmholtz vortices in the lobed jet mixing flow were revealed instantaneously and quantitatively from the measurement results of the dual-plane stereoscopic PIV system. The characteristics of the mixing process in the lobed jet mixing flow were analyzed based on the simultaneous measurement results of the steamwise vorticity and azimuthal Kelvin-Helmholtz vorticity distributions.

  • PDF

Prediction of Wheel Wear when Surface Grinding by Dual Detection Methods (평면연삭시 복합검출방법에 의한 숫돌마멸 예측)

  • 왕덕현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.172-177
    • /
    • 1998
  • An experimental study on the prediction of grinding wheel wear by dual detection methods was conducted by the laser displacement and acoustic emission(AE) system. The laser displacement sensor was located above the head of the grinding wheel and the AE sensor was set under the workpiece, where the wheel were condition can be detected. It was found that the dual detection methods by laser displacement system and AE system made it possible to predict the wheel wear. From the experiments, the root mean square(RMS) values both methods was found to be proportional to the grinding wheel wear.

  • PDF

Restoration of Chest X-ray Image Using Dual Projection Filter (이중 프로젝션 필터를 이용한 흉부 X-선 영상의 복원)

  • 이태수;민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.25-32
    • /
    • 1992
  • A new restoration method of chest X -ray image (dual project filter) was proposed to improve SNR(signal to noise ratio) characteristics. In this method, a priori Information of system and anatomical structure and statistics of projected object are used in the design of filter. Dual projection filter varies its parameters, adapting to the local regions of chest(lung region, mediasternum, subdiaphragm) and the structure of chest (bone, tissue, blood vessel, bronchia). The performance of Dual Projection Filter was 0.1-0.2dB better than Dual Sensor Wiener Filter, which was used for initial estimate of Dual Porjection Filter.

  • PDF

Heating Performance of Heat Pump System Using Dual Heat Source and Its Operation Characteristics (이중 열원 히트펌프 시스템의 난방 성능과 운전 특성)

  • Lim, Hyojae;Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.2
    • /
    • pp.30-41
    • /
    • 2021
  • This paper presents the heating performance analysis results of a heat pump system using a dual heat source. In this paper, a dual heat source refers to the ground-coupled heat exchanger using both a surface water heat exchanger (SWHE) and a vertical ground heat exchanger (VGHE). In order to evaluate the system performance, we installed a monitoring system to measure the temperature and power consumption of a heat pump and then collected operation data with 4 different load burdened ratios of the dual heat source heat exchanger. During the whole measurement period, the average heating capacity of a water-to-water heat pump unit was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the dual heat source heat exchanger used 6.7 kW of power. Therefore the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the entire system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the dual heat source heat exchanger.